Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹48.7 LAccepted-AOC | L-1 | Accepted-AOC l-1 |
Tender Value
Refer Docs
EMD Value
₹98,732
Closing Date
28 Sept 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE WSSD NO 3 JALANDHAR
EE WSSD NO 3 JALANDHAR
GOVERNMENT COLLEGE SHAHAKOT
2020_WSS_53456_1
GOVT. COLLEGE SHAHKOT RECALLED
Open Tender
Civil Works
Item Rate
365 days
IN GOVT. COLLEGE SHAHAKOT
Please refer Tender documents.
2 documents required · 2 mandatory
₹100
TIA
₹98,732
4 Dec 2020
16 Sept 2020
29 Sept 2020
16 Sept 2020
28 Sept 2020
16 Sept 2020
90 days
Amount
Boring with casing pipe for tubewell in all soils except ordinary hard rocks requiring blasting including removing the casing pipe after the tube well is lowered & tested, equipment as requried such as hand boring machine and its accessory, transportation to site and vice versa etc. complete in all respect. Boring with 250mm id Housing Pipe Upto 150 m depth BGL.
Supplying, lowering of MS Pipe as per IS:4270-2001 including MS sockets having dimensions as per IS code duly welded with MS electrode to have extra strength to lower the pipe into tubewell bore. 200mm nominal diameter (weight 41.6 kg per metre) 8.0 mm thickness
Supply and lowering of stainless steel cage type wire wound screen as per IS:8110-2000or latest with SS socket to connect strainer to strainer Duly welded with suitable grade S.S welding electrode to lower the strainer into tubewell bore.
200mm internal diameter (slot size 0.15/0.20mm) 6.30 mm thickness
Supplying, fixing and lowering of stainless steel socket as per ISI 8110-2000 or latest ISI marked duly welded with suitable grade SS welding electode to lower the straineer in to tubewell bore complete in all respect.
Supply & fixing of bail plug of M.S pipe complete with inverted U-hook attached to the bottom plug Complete in all respects. 200mm internal diameter (weight 41.6 kg per metre) 8.0 mm thickness
Supplying and fixing mild steel centering guides made out of 32mm x 6mm thick M.S. bar complete in all respects.
Supplying and fixing well cap having threads to fix on housing pipe complete in all respect 200mm id.
Supplying and fixing mild steel clamps of 150mm x 12mm made out of MS Flat (1.52 mtr long suitable to fit the housing pipe including the cost of Nut or bolt of suitable size complete in all respects (2 nos for Recharge well)
supplying, lowering and fixing of special MS sockets to connect S.S. containter to MS pipe duly welded with suitable grade welding electrode complete in all respects. 250mm i/d
Supplying at site wooden box of suitable size with lid and locking arrangement for preserving strata sample received from the bore
Development and stabilizing of the Tubewell with Air Compressor required capacity as directed by the Engineer-in-charge including the cost of tools and appliances and consumable to the satisfaction of Engineer-in-charge.
With air compressor of size 300 cfm 250 PSI
Development and stabilizing of the Tubewell with Air Compressor and submersible pumping set of required capacity as directed by the Engineer-in-charge including the cost of tools and appliances and consumable to the satisfaction of Engineer-in-charge.
Collection of Water Sample from Different Strata and testing of sample from approval laboratory (phyiscal and chemical analysis)
Providing & installing,testing & commisioning of 1 no electrically driven Submersible Pump set capable of delivering 360 LPM against a head of 51 mtr along with electric panel board consisting of electrical appliances such as automatic Star Delta Push Button or oil imeersed starter, Main Switch, VM, AMpere Meter, ELCB, Shunt capacitor. Single phase, preventer, Indicating lamps, Kit-Kat etc. including G.I column Pipe of IS 1239-2004 medium class size 50mm and Length 46 mtr. (in 3mtr lengths each with flanges,screwed and welded on both sides) rubber gaskets, nuts and bolts submersible cable of 100 mtr Length and 2.50mm2 size as per IS694-1990 reaffirmed 2000. Including cost of Electronic over current relay complete in all respects
BHP (Motor with Pump) Discharge 360LPM; Head 51mtr
Panel Board
Cable (Size/Cost) 2.50mm2=100mtr.
Column Pipe (G.I)( Size/Length) (50mm i/d)
Providing & fixing 100mm dia delivery main (from T/W to duck foot Bend) including cost of D.I D/F pipes & specials, DI SV,Non Returned Valves Double Air Valves, G.I Pipes and Specials, G.M Peet Valve and Pressure Gaguge etc. Complete
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. 110mm o/d pipe of 10 Kgf. / sqcm
Providing & fixing C.I/D.I Flanged end, stem of SS (AIS 1410) and Bronze (gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing, testing & cost of Nut, Bolt & insertion sheet, all carriage complete (with the approval of Engineer - in – charge) class PN-1 as per ISI (Class PN-1 as per ISI ) 100mm i/d Sluice Valve flanged
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Including Carriage Size 0.9 m. x 0.9 m.
Excavation by mechanical means(JCB or Hydraulic excavator) in trenches for pipe lines with straight or open cutting in streets or open area including trimming and dressing sides levelling of beds of trenches to correct grade, cutting joint holes, refilling consolidation, watering, including the cost of dewatering of rain water, diversion for traffic, night signals. providing & fixing caution boards, crossing over trenches for access to the houses, watching, fencing, etc. and removal of surplus soil out side/inside the town involving lead upto 15 meter complete in all respect. Earth work upto 1.5 m. Depth for All classes of soil except rocky
Providing & G.I barbed wire (3 ply) fencing around the Head works site in 3 rows complete in all respects.
Providing and Fixing precast pre-stressed cement concrete fencing pole M-40 by 4 Nos. parallel high tensile entwined wire (ISI marked wire 4 mm dia fencing pole size at bottom 4" x 4", size top 3" x 4",Lenght 6ft, hooks 6 No. including cost of excavation, sand filling and erection complete in all respects.
Providing & fixing D-Hooks as per DWSS as per standard drawing
Construction of Brick masonry corner pillars as per W/S & Sanitation Deptt: Standard design including Cost of material such as Bricks, sand, Cement, Bajri, etc. complete respects as per W/S & Sanitation Deptt. Standard design and drawing.(Including Carriage)
Providing and fixing in position steel gate complete with masonary pillars as per W/S & sanitation Deptt. Standard design and drawing.size 1.22 mtr x 1.37 mtr (Including Carriage)
Construction of Cement Concrete Footpath with BM Toe wall on both side, earth filling inside as per standard drawing as per DWSS std. Including Carriage
Construction of Pump chamber size 3.05 m x3.70 m with gravel pit but including electric wiring as per DWSS standard design and analysis complete in all respects. Including provision of Sanitary Latrine in pump chamber for foundation and plinth of WC rooms including flooring, PVC pipes, Junction Box, 1 No. Leach Pit, Super Structure WC room etc. including carriage
Providing Installing testing and commissioning and one no. electronically actuated, diaphragm operated, metering system, chemical dosing chlorinator, suitable for delivering 0.5 to 6 leter of bleaching powder solution /sodium hypo solution per hrs under maximum deliver pressure upto 7kg/cm2 and suction left not less than 1.5 meter.
Constructing one No. of 25 KL (25000 litres) Capacity with sill level not less than 15.50m height upto FSL 18.00 mtr from formation level complete with external RCC stair case with landing slabs at each staging RCC roof, ventilator single main hole cover lightening conductor etc. complete as described in schedule No.3. Providing and fixing C.I. D/F expansion joints or latest bell mouth and D/F puddle collars as per DWSS design on basis of enclosed drawing. Duck foot bends, Conforming to ISI - 13382 and C.I. D/F sluice Valve duly ISI marked (IS-14846-2000 or latest) one each with inlet, outlet and scour pipes, including providing and installing inlet, outlet scour pipe and overflow C.I. double flanged pressure pipes horizontally as per IS 7181/1986 and latest duly ISI marked from bottom dome to duck foot bend and further up to 2.75 mtr as per detail specification. TMT steel & painting of all complete shall be included in cost & P/F aluminium leader inside the OHSR complete in all respect as per specifications. (The specifications & drawing are based on safe bearing capacity of soil of is less than 8.75 tone per sqm. In case the safe bearing capacity of soil is less than 8.75 tone per Sqm. The contractor shall submit his own design for foundation portion based on actual safe bearing capacity as per DWSS specifications. The difference in quantities from the standard drawing based on 8.75 tone per sqm safe bearing capacity will be paid as per CSR+ Prevailing Ceiling Preminum including providing and fixing automatic Electronic Water Level control Device and Construction of Plinth protection around OHSR with masonry toe wall with 40 mm thick CC 1:2:4 on top over 100 mm thick CC 1:8:16 & inside earth filling, including overflow scower haudi complete in all respects.
Providing, Fixing, laying, jointing, cutting & testing of uPVC Pipes & Specials (6 kg./cm2) including cost of excavation complete in all respects as per DWSS standard analysis. Excavation with Manually
110mm o/d pipe of 6 Kgf. / sqcm
90mm o/d pipe of 6 Kgf. / sqcm
Providing & fixing C.I. D/F. Flanged end, stem of SS (AIS 1410) and Bronze(gunmetal) working parts Sluice Valves ISI marked 14846-2000, including jointing , testing & cost of Nut ,Bolt & insertion sheet, all carriage complete (with the approval of Engineer in-charge). Class PN-1 as per ISI
80mm i/d Sluice Valves flanged
Construction of masonary Sluice Valve Chamber excluding Sluice valve cover as per standard design & drawings of public health department. Including Carriage Size 0.6m. x 0.6m.
EXTERNAL IN THE GROUND : Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes as per IS 15778 (ISI marked with the prior approval of Engineer-in-Charge), having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings. This includes jointing of pipes & fittings with one step CPVC solvent cement, & testing of joints excluding cost of excavation complete as per direction of Engineer-in-Charge.
25mm o/d (Stacking for Lawn hydrant)
Providing, fixing and jointing ISI Marked Gun-Metal peet valves (Heavy Pattern) as per IS 778 with hand wheels, on G.I. Pipe lines laid in the ground or inside buildings including all carriages complete. 25mm i/d Gun Metal peet valve heavy pattern.
Painting G.I. Pipes and Specials with synthetic enamel Paint in all shades as per I.S.I. specification on existing or new work, two coats paints including cleaning rubbing surface, etc.
40mm & 50mm i/d G.I. Pipe
25mm &32mm i/d G.I. Pipe
Providing and filling sand grading as per specifications or fine grade around the various sizes of CPVC pipes in external work. For 50mm CPVC Pipe
Providing, laying in trenches to correct gradient and alignment and jointing of UPVC pipe having ISI specifications IS:15328-2003 class SN-8 and laying the same in trenches to correct alignment and gradinets, cutting and jointing, testing for water tightness and making good the leakages and defect including cost of specials complete in all respects. For Sewer Line IC to IC 4 mtr each
160 mm i/d pipes
200mm i/d pipe
Excavation in trenches with straight or open cutting in streets lanes or in open area with 3D / JCB or excavator including manually dressing bed, triming side slopes for sewers manholes to full depths as shown in drawings, including shoring, dressing to correct sections and dewatering providing for diversion for traffic, protection of existing services i.e. telephone cables ,electric lines, water supply lines and gas lines etc. night signals, profiles, pegs, sight rails, boning rods, fixing and maintenance of caution boards, fencing, refilling trenches, watering, ramming and restoration of surface to original level and removal of surplus spoils from the site of works upto 15 metre complete in all respects. For depths not exceeding 3.0 metre B.G.L. For all classes of soil except rocky For Sewer Line 200 mm, 160mm, Manhole 90cm x 150 cm & 75cm x 120cm For Rain water Line 250mm & 160mm o/d PVC pipe, Houdi 0.90m x 0.90m
Constructing brick masonry manhole in cement mortar 1:5 ( 1 cement : 5 coarse sand ) R.C.C. top slab 20cm thick using M-20 mix by using mixer and vibrator, TMT Fe500 @ 63.464 kg/per cum, foundation concrete 1:4:8 mix (1 cement: 4 coarse sand : 8 graded stone aggregate 40mm nominal size) inside plastering 12mm thick with cement mortar 1:3 (1 cement: 3 coarse sand) finished with floating coat of neat cement and making 40mm thick benching in cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) finished with a floating coat of neat cement, Orange coloured PVC steps including RCC cover with frame complete as per standard design complete in all respects. Inside size 75x120 cm with depth 120 cm between bottom of top slab and invert ( with MH cover & frame Heavy duty) (6 No.)and Inside size 90x150 cm with depth 120 cm between bottom of top slab and invert ( with MH cover & frame Heavy duty) (14 No.)and 2 Nos Recharge well 3 mtr diameter&19 Nos houdies size 0.90 x 0.90 mtr for rain water harvesting (including Carriage) (Quantity as per below):
Cement concrete 1:4:8(1 cement:4 coarse sand:8 graded stone ballast 40 mm gauge using concrete mix volumatric type (Including Carriage)
Cement concrete 1:8:16 with 40mm gauge stone aggregate using concrete mixer volumetric type (Including Carriage)
First class Burnt Brick work in foundation and plinth laid in cement mortar 1:5 (Including Carriage)
Ist class burnt brick work laid in cement sand mortor (1:4) in foundation and plinth (Including Carriage)
Extra labour for 1st class burnt brick masonary in well steining of square, rectangular or polygonal wells or Circular work
Cement concrete 1:2:4 with Stone Balast or shingle for benching (Including Carriage)
Floating coat of 1.5mm thick neat cement laid in one operation to the toping (Including Carriage)
12.5 mm thick cement plaster 1:3 (Including Carriage) with Cement Rendering on plaster 1mm thick.
12.5 mm thick cement plaster 1:2 (Including Carriage)
Reinforced cement concrete M-20 mechanically batch mixed using batch type concrete mixer as per IS:1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth (Including Carriage)
Reinforced Cement Concrete M-15 mechanically batch mixed using batch type concrete mixer as per IS 1791 and vibrated by needle vibrator but excluding steel reinforcement centring and shuttering in foundation and plinth (Including Carriage)
Extra for Fixing Inlet/ Outlet Pipe
Cold Twisted deformed (Ribbed/Tor Steel Bar) Bars Fe500 grade as per IS 1786-2008 for RCC works where not included in the complete rate of RCC including bending and placing in position complete (Including Carriage)
Providing orange colour safety footrest of minimum 6MM tnICK plastic encapsulated as per IS:10910 on 12mm dia steel bar confirming to IS: 1786 having minimun cross section as 23mm x 25mm and over all minimum length 263mm and width as 165mm with minimum 112mm space between protruted legs having 2mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specification and having manufacturers permanent identification mark to be visible even after fixing, including fixing in manholes with 230x150x75cm cement concrete block 1:2:4 (1 cement: 2 sand: 4 stone aggragate) complete as per design.
Providing & fixing 560 mm, 500 mm and 450 mm internal diametre circular or 450 mm x 600 mm clear inside opening rectangular RCC manhole cover and frame ISI marked as per IS:12592-2002 including carriage from the stores of the Engineer-in-charge to site of work, loading, unloading Including stacking and setting the same to correct lines over manholes including cement concrete copping (M:20) around the frame etc. Dia of steel for lifting hook is 16mm. (for EHD and HD). 560mm i/d RCC Manhole cover with frame Medium duty
Boring with casing pipe for tube well in all soils excepth ordinary hard rocks requiring blasting including removing the casing pipe after the tubewell is lowered & tested equipment as required such as hand boring machine and its accessory, transportation to site and vice versa etc, complete in all respect Boring with 200mm i/d Housing pipe
Supplying, assembling, lowering and fixing in vertical position in bore well, un-plasticized PVC medium well casing (CM) pipe of required dia, conforming to IS:12818-2010, including required hire and labour charges, fittings & accessories etc. all complete for all depths, as per direction of Engineer-in-charge. 150mm nominal diameter
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS:12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 150mm nominal size dia
Supplying & Fixing of M.S pipe bail plug suitable for 150mm dia uPVC casing pipe having thickness of socket as 12mm length 100mm & base plate of 8mm thick complete in all respect.
Supplying at quarry site of gravel of 1/16" to 1/8" sizes including pouring and packing in the annular space between the pipes assembly and the bore.The gravel should be free from dust,dirt, or the vegetable manner as per IS 4097/1967 with latest amendments(to be paid as per actual length of pipe)
Supplying & Fixing of well cap having thread to fix on housing pipe complete in all respect. 150mm internal diameter
Excavation in soil (any type) using Hydraulic Excavator CK 90. Excavation with hydraulic excavator of 0.9 cum bucket capacity including cutting trimming bottom and side slopes, in accordance with requirement of lines , grades and cross sections,including all lift and combined lead upto 60mtr.
Providing and placing in Horizontal layers filtering media screened washed and cleaned Bottom layer:- broken stone screened, cleaned and washed and graded form 50 mm to 75 mm
Providing and placing in Horizontal layers filtering media screened washed and cleaned Fourth layer:- Bajri (Course) screened, cleaned and washed and graded form 20 mm to 25 mm
Providing and placing in Horizontal layers filtering media screened washed and cleaned Third layer:- Bajri screened, cleaned and washed and graded form 6 mm to 20 mm
Providing and placing in Horizontal layers filtering media screened washed and cleaned Second layer:- Course Sand screened, cleaned and washed and graded form 3 mm to 6 mm
Centring and shuttering for flat surface such as Suspended floors, Roofs, Landing, Chhajjas, Shelves etc.
Providing, Laying , fixing & jointing of P.V.C. Pipes as per ISI-4985 (ISI marked with the prior approval of Engineer-in-Charge) along the Trenches and laying the same in Trenches to correct alignment and gradients, cutting, jointing and testing complete as per specifications. For Rain water Line 250, 200, 150mm o/d PVC pipe
160mm o/d PVC pipe of 4 Kgf. / sqcm
200mm o/d PVC pipe of 4 Kgf. / sqcm
250mm o/d PVC pipe of 4 Kgf. / sqcm
For connection of Road gully and sewer @ 110mm o/d 10mtr. Each per road gully (L.S.) 110mm o/d pipe of 4 Kgf. / sqcm
For connection of Road gully and sewer @ 160mm o/d 10mtr. Each per road gully (L.S.) 160mm o/d pipe of 4 Kgf. / sqcm
Constructing brick masonry road gully chambers as per standard drawings (as per sizes given below) including dressing of beds and sides of chambers to exact profiles, 15cm thick lime concrete 16:24:100 in foundation, first class brick work laid in cement sand mortar 1:5, 40mm thick cement concrete 1:2:4 topping inside the chamber with a floating coat of 1.5mm thick neat cement laid in one operation to the topping, the entire inner surface of the chamber rendered with neat cement not less than 12.50mm in thickness of 1:2 cement sand plaster and finished with a floating coat of neat cement 1mm thick left absolutely smooth polished and correct to template including cost of precasted RCC road gully grating and frame including paint with coal tar complete and to the requirement of the Engineer-In-Charge. Single Road Gully chamber Size 610mm x 457mm x 800mm No. of Road Gully @ 15mtr. C/c Distance
Providing and fixing of FIRE EXTINGUISHER CO2 type as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 4.5kg capacity
Providing and fixing of FIRE EXTINGUISHER ABC powder type (Stored pressure) as per IS:15683 complete with all accessories as per manufactures sepcification. ISI Mark Complete in all respect. 6kg Capacity
Cement concrete Slab 1:2:4 with stone balast or shingle using concrete mixture volumetric type (Including Carriage)
Earth work in excavation in foundations, trenches etc. in all kinds of soil where pick jumper work is not involved and not exceeding 2.0 meters depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 Cm. Layers with compactions including disposal of all surplus soil as directed within a lead of 30.00 mtrs.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .