Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | single₹5.2 LAccepted-Finance | single | Accepted-Finance Single tender found in order and accepted |
Tender Value
₹4.7 L
Closing Date
11 Nov 2024, 6:00 pmClosed
Executive Engineer (Civil)
O/o The Executive Engineer (Civil) 2nd Floor,BSNL Telephone Bhawan, Sri Vijaya Puram-744101.
External,Internal painting and other allied civil works to the TE building at CarNicobar HQ
2024_BSNL_213306_1
36 NIT CD PB AN 2024 25
Open Tender
Civil Works
Item Rate
60 days
Carnicobar HQ
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
Account Officer (Cash) BSNL
Exempted
14 Nov 2024
2 Nov 2024
13 Nov 2024
2 Nov 2024
11 Nov 2024
2 Nov 2024
2 Nov 2024 - 11 Nov 2024
Amount
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length ( hold fast lugs or dash fastener shall be paid for separately).
Kiln seasoned and chemically treated hollock wood.
Providing and fixing glazed shutters for doors, windows and clerestory windows using 4 mm thick float glass panes, including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws.
Kiln seasoned and chemically treated hollock wood
30 mm thick
Providing and fixing aluminium tower bolts ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing aluminium handles ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete :
Providing and fixing bright finished brass hard drawn hooks and eyes :
Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50mm (base metal of minimum 0.45mm thickness with total coating thickness of 0.05mm) with Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete:
Barge board (Upto 300 mm)
Distempering with 1st quality acrylic distemper, having VOC (Volatile Organic Compound ) content less than 50 grams/ litre, of approved brand and manufacture, including applying additional coats wherever required, to achieve even shade and colour.
Old work (Two coats )
Finishing walls with Acrylic Smooth exterior paint of required shade :
Old work (Two or more coat applied @ 1.67 ltr/ 10 sqm) on existing cement paint surface).
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :
One or more coats on old work.
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work.
Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
Applying priming coats with primer of approved brand and manufacture, having low VOC (Volatile Organic Compound ) content.
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre.
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq. meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground , all complete as per directions of Engineer-In-Charge.
With cement mortar 1:4 (1 cement : 4 fine sand).
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion,
(i)Single socketed pipes.
75 mm diameter
110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :5382 leaving 10 mm gap for thermal expansion.
75 mm bend
110 mm bend
Bend 87.5° with door
Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Flexible pipe
32 mm dia
Providing and fixing Stainless Steel grating 0.60mm thick grating for floor traps complete as directed.
100mm dia Circular
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour.
15 mm nominal bore with 45 cm length.
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hardwood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
Cleaning of terrace/loft water storage tank (inside surface area) upto 2000 litre capacity at all heights with coconut brushes, duster etc., removal of silt, rubbish from the tank and cleaning the tank with fresh water disinfecting with bleaching powder @ 0.5gm per litre capacity of tank, disposing of malba, all complete as per direction of Engineer-in-Charge. (If during cleaning any GI fittings or ball cock is damaged that is to be repaired by contractor at his own cost and nothing extra will be paid on this account)
Repairs to windows shutter (Area upto3 sqm) including taking out and refixing the same and replacement of hinges with screws wherever required etc complete
Taking out existing wooden door shutter, repair by cutting, painting etc. and refixing of repaired door shutters to existing door frames, including replacement of hinges with screws, etc. as required, all complete as per the direction of the Engineer-in-charge.
Cleaning of drainage manholes and sewer lines by removing the deposited and other rubbish from the manholes and cleaning the sewer lines by rodding and flushing with water as directed by the Engineer -in- charge. (Rate per One manhole and sewer line to next manhole)
Cleaning of floor / wall tiles in bath rooms, WCs and wash area etc using detergent, acid etc., complete as directed.
For toilets of area upto 3.00 Sqm
Weeding out tree growth embedding from complete bulding/pipe lines at different locations and at varying height from Ground level to 7mtr from ground,plucking, pulling out roots embedded deep inside the building, pouring acid to prevent further gowth of plants,including finishing,scaffolding, etc, all complete as per the directions of Engineer-in-charge. Tree grith up to 30cms and height up to 3.00 Mtrs.
Cleaning of nahni traps/floor traps at all levels for removal of blockages including removing the silt, slush, waste etc ensuring smooth flow etc and applying white cement in tile joints of bath/WC including water proofing compounds (Like forsroc) etc wherever required to arrest leakages etc.
stage.html
html • 0.03 MB
tech_eval.pdf
fin_eval.pdf
finance_235134.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .