Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹31.9 LAccepted-AOC HOUSE NO 102 LANE NO 4 C ANAND NAGAR BOHRI JAMMU 180002 J K | JAMMU | JAMMU AND KASHMIR | 180002 | L1 | Accepted-AOC Being L1 bidder | |
| 2 | L2₹36.9 L+₹4.9 L (15.4%)Rejected-Finance 403 GH MANSADEVI COMPLEX PANCHKULA 134109 HARYANA | PANCHKULA | HARYANA | 134109 | L2 | Rejected-Finance Other than L1 bidder | |
| 3 | L3₹38.9 L+₹6.9 L (21.7%)Rejected-Finance H NO 1395 SECTOR 21 PANCHKULA 134112 HARYANA | PANCHKULA | HARYANA | 134112 | L3 | Rejected-Finance Other than L1 bidder |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
20 Apr 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Cdr, HQ 138 WE
HQ 138 Works Engineers PIN-914138 C/O 56 APO
REPAIR / MAINT OF HT DISTRIBUTION SYSTEM AND OTHER CONNECTED WORKS UNDER AOR OF AGE EM-II OF GE 865 EWS AT LEH
2024_MES_647704_1
138WE/L-02/2024-25
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GE 865 EWS
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE 865 EWS
₹80,000
Yes
10 Jul 2024
23 Mar 2024
27 Apr 2024
23 Mar 2024
20 Apr 2024
6 Apr 2024
Amount
Excavation in trenches, in any type of soil not exceeding 1.5m wide or 10 Sqm on plan and not exceeding 1.5m in depth for foundation, Pole, shafts, cesspits, manholes, pier holes, Laying of UG cables etc and getting out in any type of soil complete all as specified and directed.
All as per item No 1 above but additional 1.5 mtr or part thereof in depth beyond the first 1.5m complete. all as specified and directed.
Returning, filling in excavated approved soil, including spreading, levelling, watering and well ramming in layers not exceeding 25cm each complete. all as specified and directed.
Removing excavated soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point complete. all as specified and directed.
Material and labour for clean and dry sand (unwashed) in trenches and cable ducts including spreading and levelling for cushioning of underground cables all as specified and directed. Note : Punned thickness of 18 cm will be measured and paid.
Supplying and laying un-reinforced precast concrete cable cover, class HV, Type 1, flat, size 300mmx l80mm x 40mm complete all as specified & as directed.
Dismantling steel poles/struts, any size complete all as specified & as directed.
Supply, erecting and fixing in true vertical position Steel tubular swaged poles(11.0 metres long) complete with cast iron base plate, finial taper plug,bolts,nuts & screws as specified type 410 SP-55 , complete all as specified. Note : - Earth work & PCC work will be measured & paid seprately under relavent item.
Material & labour for PCC 1:4:8, type D2 ( using 40 mm graded stone aggregate) as in base for foundation of the pole, all as specified and directed.
Material & labour for Providing PCC 1:3:6, type C2 (using 40 mm graded stone aggregate) as in mass filling all as specified and directed.
Material & labour for providing PCC 1:2:4 type B1 (Using 20 mm graded stone aggregate) for plinth coping all as specified and directed.
Supply & Laying in trenches/through pipes / ducts or on poles XLPE insulated,screened, PVC bedded, galvanised steel strip armoured , electric power cables(heavy duty) with aluminium conductor, 11 KV,grade 95 sqmm 3 core (E) confirming to IS-7098. including taking down old one, all as specified and directed.
M&L for alternative arrangement by hiring, transportation of transformer of capacity upto 100 KVA in place of unserviceable copper /aluminium wound from transformer of capacity upto 100 KVA, opening top cover, and carrying out the following work complete all as specified and directed :- (a) Dismantling of all attachment viz breather assembly, conservator, oil temperature gauge, HT/LT bushing minor repairs etc. as required and directed and keeping aside for reuse. (b) Taking out the core with winding assembly. (c) Removing of complete winding from core and dismantling the core, cleaning of core laminate sheet and keeping aside for reuse (d) Cleaning of complete transformer tank oil fins, removing of sludge, and making the inside surface of tank dry by blowing of hot air as directed and specified. (e) Painting of outside surfaces of transformer complete by means of spray machine as directed. (f) Rewinding of HT/LT leg coil complete using super enamel copper wire /strip of appropriate gauge, size and turn as per existing with double paper coated insulation including all requisite insulating materials like packing sleeves, separator, tapes etc. heating, varnishing the core and winding assembly after framing up top and bottom steel structure of transformer all as specified and directed. (g) Replacement of all insulating materials other than incorporated for rewinding of HT/LT coils as per existing.
(h) Fixing only HT procelain bushing with studs, nuts, washers 3 Nos. and LT procelain bushing with studs, nuts, and washers 4 Nos. and connection with primary and secondary windings and reconnecting with the main terminals as required and directed. (j) Replacement of all unserviceable gasket from top cover, HT/LT bushing with new one by using rubberised gasket sheet 4.0mm/6.0mm thick duly pasted with suitable adhesive . (k) Replacement of unserviceable bolts with new one and fixing of existing serviceable bolts, nuts, washers of different sizes and tightening properly. Note :- (i) The contractor shall give written warranty of one year from the certified date of completion for the repaired transformer. (ii) HT/LT leg coils and transformer oil required for top up shall be measured and paid separately under relevant items of this Schedule here-in-after as supply only.
All as per Srl item No. 13 above but of capacity 200 to 400 KVA. all as specified and directed.
All as per Srl item No. 13 above but of capacity upto 630 KVA to 1000 KVA. all as specified and directed.
M&L for rewiding of HT/LT coils of transformer of capacity 25 KVA to 400 KVA with super enamelled copper winding wire of appropriate gauge and proper number of turns alongwith insulating material eg leatheroid, paper insulation, cotton tapes, Empire tapes, wooden block packings, PVC sleeves, soldering and varnishing with insulating varnish , heating/drying etc complete all as specified and directed by Engr-in-Charge.
Supply and fixing of HV bushing with brass metal connecting rod, nut, bolt and washer suitable for transformer 100 KVA to 1000 KVA, 12 KV as per IS, replacement of worn out stud complete all as specified and directed.
Supply and fixing of LV Bushing of transformer with Brass metal connecting rod, nut bolt and washer, suitable for 100 KVA to 1000 KVA capacity of tranaformer 1100 Volt as per IS complete all as specified and directed.
Supply and fixing in replacement of Silica gel breather assembly complete with silica gel crystal for the capcity of transformer 100 KVA to 1000 KVA all as specified and directed.
Supply and fixing in replacement of Tinned copper flexible wire 60 to 200 Amps for HT fuse complete. all as specified and directed.
Material and labour for Cable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm 3 core with working voltage 11000 volts complete all as specified and direced by Engr - in- Charge.
Material and labour for Cable joining kit for 11 KV (Earthed) grade cable for straight through heat shrink type joint complete with joining material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 sqmm 3 core with working voltage 11000 volts complete all as specified and direced by Engr - in- Charge.
Supply and fixing in replacement jointing kit for 11 KV (Earthed) grade cable for indoor termination heat shrink type joint kit complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm . all as specified and directed.
Supply and fixing in replacement jointing kit for 11 KV (Earthed) grade cable for outdoor end termination heat shrink type joint kit complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm . all as specified and directed.
Restringing of HT overhead line conductor comprising of any size ACSR conductor after opening from insulators, including restringing same and winding on insulator with proper size of binding wire upto permissible sag including cutting, trimming and vending of branches along HT line and removing of creepers from poles / conductors complete all as directed.
Disconnecting and taking out worn out jumpers / connectors of HT over head line / DO fuse unit in substations of any size or any length after removing binding wire / connector and replacement with the new ACSR weasel conductor jumpers including PVC sleeve in colour coding R/Y/B of same size and length approx 1.5mtr including new binding wire/ connectors suitable for AB switch/DO fuse unit, including provision of conducting jelly all as specified & directed by Engr-In-charge.
Repairing and servicing (Oiling and greasing) of Gang Operated Switch 11 KV vertical/Horizontal mounted and replacing defective parts including replacement of unserviceable spare parts as required for smooth functioning of AB switch, testing for its proper operation, all as directed at site.
Dismantling UNSV air break gang operated switch and Supply, installation connecting electrically & commissioning switch air break, gang operated, tripple pole mounted on Polymer insulators 15 Nos and steel frame with operating mechanism with 20 mm dia GI Pipe (Medium Grade) Rod worked from ground level, drop out fuse, for current rating upto 200 amps and working voltage 11000 volts all as required at site or directed by Engr-in-charge.
Supply & fixing in replacement lightning arrestor suitable for 11 KV grade, thyrite type, complete with all fitting transmission class for outdoor discharge capacity 65 KA complete. all as specified and directed.
Dismantling insulators any type, any size complete all as specified and directed.
Supply and fix in replacement disc type insulator, porcelain, vitreous, white brown or green, 150mm high, and 150mm dia ball and socket type single disc assembly for tension with tension clamps for conductors, working pressure 11000 volts grade complete all as specified and directed.
Supply and fixing in replacement 11 KV HT Pin type polymor insulator including one galvanised mild steel spindle, two galvanised iron washers and one galvanised iron nut, suitable for working pressure 11000 Volts grade complete all as specified and directed.
Dismantling of ACSR conductor any size complete all as specified and directed.
Material and labour for ACSR conductor of required size for O/H lines, on HT poles, including stringing and binding wire, complete all as specified & directed.
Fixing only of ACSR conductor of any size obtained from item No. 33 here-in-above with required sag, including jumparing. all as specified and directed.
Dismantling and taking out damaged / rusted cross arms, of MS channel or angle section etc complete and setting aside for reuse within 50 mtrs. all as specified and directed.
S& fix for cross arms, bracings, supports, clamps and back plates fabricated from structural steel section including nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape or size as directed including two coats of synthetic enamel paint over a coat of red oxide primer, complete all as specified and directed.
Dismantling and taking out damaged / rusted GI earth wire / cradle guard complete. all as specified and directed.
Supply and fixing / stringing, galvanized steel wire 4mm dia for earth conductor, on HT poles including binding wire etc complete all as specified and directed.
Material and labour for danger notice plate for HT of size 25 cm x 20 cm x 1.6 mm thick mild steel sheet, vitreous enamelled white with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps, bolts and nuts complete all as specified.
Material and labour for painting of 11 m steel tubular pole and cross arms, clamp of any length and shape for HT overhead line with two coat of aluminium paint including preparation of the existing surface including marking pole numbers in a 15 cm dia yellow circle & marking three bands width 30 cm by enamel paint, from bottom of pole to 1.5 Mtr height, complete all as specified and directed.
All as per Srl item No. 41 above but 2 pole structure steel tubular HT poles. all as specified and directed.
All as per Srl item No. 41 above but 4 pole structure steel tubular HT poles. all as specified and directed.
Earthing complete with galvanized steel earth plate electrode 60cm x 60cmx 6 mm thick buried directly in ground (earth pit not less than 2.25 meter deep below ground level) with top edge of the earth plate not less than 1.5 meter below normal ground level connected to galvanized iron strip 32 x 6mm as earthing lead by means of bolt and nut, check nuts and washer of galvanized iron or steel all as shown in electrical plate No 5 of MES Schedule part I with and including excavation & earth work in any type of soil, providing charcoal dust and common salt upto 15 cm above top edge of earth plate, construction of PCC pit in cement concrete 1:3:6 type C-1 with 40 mm thick RCC 1:2:4 type B-1 reinforced with 8 mm dia MS deformed bars @ 100mm center to center both ways watering arrangement with funnel and wire mesh and watering pipe of 20mm dia GI light grade and 40mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and directed.
M&L for Earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to pole or any other indicated situation for loop earthing etc, as required galvanised iron strip 32 x6mm, complete all as specified and directed.
Material and labour for servicing /testing and calibration of breaker/control panel including CT, PT and relays in control panel of VCB of capacity 630/800 Amps and rating 11 KV complete as details mentioned as under:- (a) Details of servicing of breaker :- (i) Adjustment of mechanism if required. (ii) Clean the circuit breaker to remove dust and dirt. The envelope of the vacuum interrupter and insulating materials shall be wiped with a clean cloth. (iii) Apply a small amount of oil to rotary sections, sliding surfaces, pins, coupling section, etc.use grease for the operating shaft and bearings, and machine oil for other parts. (iv) Check for rust and wear. (v) Check Spring Tension and pitting of the Cluster Contacts. (vi) Visual check for rust and deformation. (vii) Check for loosened bolts and nuts, broken spring washers and snap pins etc. (viii) Check for loosened connections, rust, damaged lead wires. (ix) Check whether the contacts are damaged by arcing. (x) Checking of control circuit & tighten the connections if any. (xi) Check close & trip coil. (xii) Checking of Jaw Contacts Conditions and repair/adjust. (xiii) Replace the jaw contacts,If required. (xiv) Improvement of resistance of epoxy insulator and epoxy body by applying post heated varnish. (xv) Replacement of Dashpot/shock absorbers . (xvi) Replacement of carbon brush of spring charging motor
(b) The following test shall be carried out:- (i) Primary Injection Test of CT / PT (ii) Closing & Opening Timing Test for all three poles. (iii) IR Test with megger in open and closed condition. (iv) Contact resistance test for all three poles (v) Closing coil resistance (vi) Tripping coil resistance. (c) Testing of following relays of control panel with Secondary Injection Kit ,checking and programming of relay :- (i) Over current and earth fault relay Note :- The Servicing / testing and calibration shall be done by authorised service Engineer of manufacturer.
S&F in repairs Shunt trip coil for 11 KV HT VCB of C&S make complete all as specified and directed.
S&F in repairs closing coil for 11 KV HT VCB of C&S make complete all as specified and directed.
S&F in repairs spring charging motor for 11 KV HT VCB of C&S make complete all as specified and directed.
S&F in repairs Limit switch of type LSMS11, AC 15, 3A/400 V for11 KV HT VCB of C&S make complete all as specified and directed.
S&F in repairs Breaker control switch 10A, spring return to neutral 3 position & label trip-neutral-close for 11 KV HT VCB of C&S make complete all as specified and directed.
S&F in repairs IDMT non directional O/C & E/F relay aux.-110V DC (IRI-PRO-3I-EI-5-5) complete all as directed.
S&F in repairs HT HRC fuse of 10 to 63 Amp as per sample. Make: L&T/ Bussmann complete all as specified and directed.
S&F in repairs CT's 200-100/5-5A dual core, resin cast ,core 1:- metering-15VA CL-1, core2:- protection-15VA CL-5P10, STC-18. 4kA for 3s complete all as specified and directed.
S&F in repairs Digital ammeter 11 KV HT VCB size 144x144mm complete all as specified and directed.
S&F in repairs Digital voltmeter for 11 KV HT VCB Size - 144x144mm complete all as specified and directed.
S&F in repairs LED type indication lamp red, yellow, blue color 63.5v ac, dia - 22.5mm complete all as specified and directed.
S&F in repairs LED type indication lamp red, green, blue, white color 110v ac, dia - 22.5mm complete all as specified and directed.
S&F in repairs Space heater 80W 230V AC for 11kV HT electric VCB complete all as specified and directed.
Taking out defective multifuctional protection relay from 11 KV VCB Panels and supply and fix of REF 615 digital multi functional protecton relay with consits overcurrent, dir earth fault, combined protection, In sync for close, Frequency protection, beaker failure, Disturd rec triggered, CB conditon moniterring and supervsion of all data. all as specified and directed. Make : ABB or Schneider or CG or equivalent.
Material and labour for painting of Transformers outer body of capacity 100 to 400 KVA including cleaning / preparing the old painted surface before spray paint of existing colour of transformer all as specified and directed.
Description as per item No 61 above but of capacity 500 to 1000 KVA Transformers of any type . all as specified and directed.
Dehydration of HV / EHV grade transformer oil minimum three cycles to achieve dielectric strength not less than 50 KV for 1 minute with 2.5mm Gap as per IS - 335 - 1983 for EHV grade including topping up with new transformer oil all as directed. Note :- (i) Centrifuging Machine with all T&P & testing machine of oil, required for dehydration shall be arranged by contractor. (ii) Oil required for topping up the transformer will be measured & paid separately.
Supply and fill up transformer oil as in topping up/ refilling of transformer having dielectric strength not less than 55 KV at 2.5 mm gap conforming to IS incl testing complete. all as specified and directed.
Disconnecting and removing LT Cables and other connections and Strip opening of Servo stabilizers of 75 to 750 KVA, 433 volts indoor/outdoor type of any make after unsecrewing nuts/bolts screws and connected accessories such as breather,temperature gauge for replacement of defective LT coils,replacement of drain valve, paper insulation strip, electronic cards of each phase (RYB) etc and other defective parts i.e. servo motor, Out /In terminals. (payment of defective replaced parts shall be measured and paid seperately. Re-assembling after replacing the defective coils parts and replacing the top gasket sheet and other insulating, packing materials and testing complete all as specified and directed. Note :- The reassembling element covers the assembling of parts not to be changed where as for the rest it shall be the part of the item being replaced.
M & L for replacement of servo synchronous motor of existing model and capacity including. testing and commissioning after repair complete all as specified and directed.
M & L for replacement of Variable Auto Transformer suitable for 75 to 750 KVA servo Voltage Stabulizer working pressure of copper winding with suitable guage of wire of existing model and capacity including. testing and commissioning after repair complete all as specified and directed.
Supply only rubber hand gloves (ISI Marked) suitable for working with 11 KV HT lines complete all as specified and directed.
Opening up of Packaged Substation 500 KVA FBX E/12-21/C+C+T2 FBX Gas insulated switchboard 2 xswitch disconnector 630 A 1 x circuit-breaker 630 A 12 Kv 630 A 21 kA rms 3 s IEC 62271-1 Manual O -3 min - CO: circuit breaker and complete servicing of panel including following parts Earthing Switch Load Break Switch Line Isolating Switch Motorized Control Mechanism Male Female Fixed & Moving Contacts CT 30/1 A 10 PS 2.5 VA PT 11KV/ 110 V maintenance operations of the VDS boxes The check list is to be as per O&M manual of Schneider Infrastructure ltd and also covers following and a record maintained Verification of the presence and condition of accessories (levers, etc.) Visual inspection of the exterior (cleanliness, and ensure absence of oxidation, etc. If oxidation persists use silica gel crystal) Cleaning of external elements, with a clean, dry cloth Verification of the positioning of the status indicators (open and closed) Verification of the functioning of the mechanical control mechanism by making several maneuvers Visual surveillance of the general appearance of connections Note: Material for incorporation will be measured and paid separately as per other items of work Note: Work to be carried by OEM or it’s authorized representative or Dealer having service workshop
Material & Labour Earthing Switch 12 Kv 630 A 21kA rms 3 phase all as specified and directed.
Material & Labour load break switch 12 Kv 630 A 21 kA rms 3 phase all as specified and directed.
Material & Labour line isolating Switch 12 Kv 630 A 21 kA rms 3 phase all as specified and directed.
M&L for Replacement of a voltage indicator unit : Type VPIS all as specified and directed
M&L for Replacement of the three fuses amperage 30 A at 11 KV HRC type all as specified and directed Make L&T/ C&S/Crompton
S&F of manometer for altitudes higher than 1000 m reading up to 5000 m all as specified and directed
Material & labour for Filling of SF6 gas 3.35 Kg at 0.02 MPa sealed Pressure system in the FBX Switch as per instructions AMTNOT131-02/ AMTNOT132-02 under IEC -62271-200 Each job includes gas quantity of 3.35 Kg or more as required upto the mark at site all as specified and directed
Servicing Transformer side T2 function of the FBX Gas insulated switchboard The 11KV/433V 500 KVA transformer outgoing feeder using MCCB Disconnection of HT/LT sides, removal of earthing connections and servicing of Bus bar sleeves by providing Fire Retardant HT paint on the sleeve of specified thickness to achieve 12 KV dielectric strength Paint shall be from Denson/Mseal/ Raychem/Kumar Rethimbling of all outgoing & incoming cable using aluminum thimbles & crimping tool The servicing to be carried out by Schneider Infrastructure only. Parts required to make the panel & transformers serviceable will be measured & paid separately all as specified and directed.
M&L Front Connection Kit for ACB Drawout type complete all as specified and directed
M&L Top &bottom mounting ACB 1200 Amp complete all as specified and directed
M&L ACB 1200/1250 AMP microprocessor based front operated manual with E/F & O/C protection and CT PT Drawout type complete all as specified and directed
S&F of MCCB microprocessor based 3 pole 36 KA 400 A complete all as specified and directed
S&F of MCCB microprocessor based 3 pole 36 KA 200 A complete all as specified and directed
S&F of MCCB microprocessor based 3 pole 36 KA 100 A complete all as specified and directed
EESSI
R B TRADERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .