Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹11.7 LAccepted-AOC NEAR PARDEEP MEDICAL HALL DEEP NAGAR JALANDHAR CANTT JALANDHAR PUNJAB 144005 | JALANDHAR | PUNJAB | 144005 | L1 | Accepted-AOC Lowest bidder | |
| 2 | L2₹13.8 L+₹1.7 L (14.1%)Rejected-Finance 158 PADRI BAZAR TINKONIYA NO 1 PARVATIPURAM GORAKHPUR GORAKHPUR UTTAR PRADESH 273014 | GORAKHPUR | UTTAR PRADESH | 273014 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹16.5 L+₹4.4 L (35.9%)Rejected-Finance | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹17.3 L+₹5.2 L (42.5%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹18.7 L+₹6.5 L (53.8%)Rejected-Finance INDEX NO E 29 CWE JRC 352 3 GURU NANAK PURA EAST JALANDHAR CITY PIN 144001 | JALANDHAR CITY | JALANDHAR | PUNJAB | 144001 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
12 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (EAST) JALANDHAR CANTT
GE (EAST) JALANDHAR CANTT
REPAIR MAINT OF EXTERNAL ELECTRIC SERVICES AND ALLIED WORKS IN MAP ACCN OF JALANDHAR CANTT UNDER GE (EAST) JALANDHAR CANTT
2022_MES_507354_1
GE/JULL/ET-70/2021-22
Open Tender
Civil Works
Item Rate
273 days
Jalandhar Cantt
AS PER TENDER DOCUMENTS
8 documents required · 8 mandatory
₹500
Garrison Engineer (East) Jalandhar Cantt
₹40,000
Yes
7 May 2022
12 Feb 2022
19 Mar 2022
12 Feb 2022
12 Mar 2022
28 Feb 2022
60 days
Amount
Taking down old unserviceable LT underground cable of any cross sectional area, any type, any make by opening connections and joints including pipes, bricks etc of any description laid in trenches or fixed with walls/ poles, segregated serviceable bricks/ cable cover, cables etc and keep in safe custody for reuse, complete all as specified and directed. Note : Earthwork will be measured and paid under appropriate items
Supplying, Laying, jointing and testing LT underground XLPE insulated, armoured, heavy duty electric cable PVC sheathed with stranded aluminium conductor, 1100 volts grade of size 16 Sqmm 2 core, laid in trenches, in floor, in duct, through pipes or along the pole including taking up existing defective cable complete all as specified and directed. Note: Excavation & earthwork, sand cushioning, brick protection cover, GI protection pipe and clamps shall be measured and paid for separately
All as per item No. 2.00 but of size 35 Sqmm 3½ core.
All as per item No. 2.00 but of size 120 Sqmm 3½ core.
Laying only in trenches/ clamped with wall/ on floor/ In ducts / through pipes for replacement of LT cable XLPE insulated, PVC sheathed galvanized steel strip or wire armoured, electric power cables, 1100 volts grade with stranded aluminium conductor of size 35 sqmm 3.5 core complete all as specified and directed Notes : (a) Earthworks, sand cushioning, etc will be measured and paid under appropriate items. (b) The quoted rate includes the cost of collecting the cables from MES store yard or other site as directed by JE/ Engineer-in-Charge and shifting to work site where required
All as per item No. 5.00 but of size 95 sqmm 3.5 core.
All as per item No. 5.00 but of size 150 sqmm 3.5 core.
Laying only cable cover/ brick, laid breadth wise along the length of cable laid in trenches complete all as specified and directed. Note : Serviceable cable cover/ bricks obtained from Item No. 01 here-in-before.
Supply and fixing 100mm bore galvanised pipe light grade fixed along poles/ to walls/ laid under floor complete with and including fittings and clamps as required complete all as specified and directed.
All as per item No. 9.00 above but 80mm bore pipe
All as per item No. 9.00 above but 50mm bore pipe
Excavation in trenches in soft/ loose soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for laying of cables, erecting poles, stay assembly etc. and getting out complete all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm thick each layer complete all as specified and directed..
Removal of surplus spoil to a distance n. exc. 50 mtr and depositing where directed at a level n.exc. 1.5 mtr above the starting point complete all as specified and directed
Material and labour for sand cushioning with 8cm thick layer of sand before laying of cable and 15cm thick after laying of cable in trenches complete all as specified and directed
Supply & laying old size sub class 'B' bricks laid flat in trenches over the cable with the length of brick perpendicular to the direction of cable length complete all as specified and directed
Supply and fixing in replacement CVCC type, BIS marked electronic driver duly enclosed potted LED driver having protection against over voltage, short circuit and open circuit, voltage band 100 volts to 270 volts, suitable for LED street light of capacity 45W complete all as specified and directed.
All as per item No. 17.00 above but 60W
Material and labour for replacement of bakelite terminal block suitable for 35 Sqmm 3.5 Core aluminium cable complete all as specified and directed.
All as per item No. 19.00 above but 50 Sqmm 3.5 Core
Cutting and cleaning of grass upto 5m x 5m area by using suitable chemical or manually all around near 4 pole / 2 pole structure area complete all as specified and directed
Supply and fixing in replacement cable jointing kit suitable for XLPE armoured aluminium cable of size 95 Sqmm 3 Core 11 KV grade cable for indoor type termination cold shrinkable joint complete with jointing material and accessories complete all as specified and directed
All as per srl item No 22.00 but suitable for 185 Sqmm 3 Core cable.
All as per srl item No 22.00 but suitable for 300 Sqmm 3 Core cable.
Supply and fixing in replacement cable jointing kit suitable for XLPE armoured aluminium cable of size 95 Sqmm 3 Core 11 KV grade cable for outdoor type termination cold shrinkable joint complete with jointing material and accessories complete all as specified and directed
All as per srl item No 25.00 but suitable for 185 Sqmm 3 Core cable.
All as per srl item No 25.00 but suitable for 300 Sqmm 3 Core cable.
Material & Labour for locating fault of LT underground cables of size 6 sqmm to 50 sqmm 2 core/3.5 core laid in trenches by locating fault visually or by excavating the faulty portion of cable (upto 10 mtr of length) taking out to protection bricks or cover, sand and faulty cable and making of joint or repair to existing joint including all jointing material such as LT joint, ferrol and relaying after repair including refilling of sand and relaying of brick protection cover complete all as specified and directed.
Material & Labour for locating fault of LT underground cables of size 70 sqmm to 185 sqmm 3.5 core laid in trenches by locating fault visually with fault locator machine or by excavating the faulty portion of cable (upto 10 mtr of length) taking out to protection bricks or cover, sand and faulty cable and making of joint or repair to existing joint including all jointing material such as LT joint, ferrol and relaying after repair including refilling of sand and relaying of brick protection cover complete all as specified and directed. Notes for Srl No. 28.00 & 29.00 :- (a) LT joint will be measured and paid Separately. (b) The contractor will have to arrange the fault locating machine, if contractor fails to diagnose/locate the fault within 4 Hrs of fault intimation A penalty of Rs 300 per Hour will be imposed/ levied, if contractor fail to restore the supply due to non availability of fault locator machine and labour. (c) The quoted rate includes cost of arranging, shifting of fault locator machine at site.
Supply and fixing cable jointing kit suitable for XLPE armoured aluminium cable of size 35 to 70 sqmm 3½ core 1.1 KV grade cable for straight through type termination heat shrinkable joint complete with jointing material and accessories complete all as specified and directed.
Supply and fixing cable jointing kit suitable for XLPE armoured aluminium cable of size 95 to 185 sqmm 3½ core 1.1 KV grade cable for straight through type termination heat shrinkable joint complete with jointing material and accessories complete all as specified and directed.
Labour only for cutting/ pruning of tree branches 1.5 mtr all around the street light poles and street lights fittings including removing the branches to a distance upto 100m to the entire satisfaction of Engineer-in-Charge
Earthing complete for feeder pillar / LT Panels with galvanised steel earth plate electrode 60cmx60cmx6mm thick buried directly in ground vertically at a depth not less than 2.25 metres below normal ground level with top edge of the plate at a depth not less than 1.5 metres below normal ground level, connected with and including GI strip 32mm x 6mm in and including GI pipe 50mm bore light grade as protection pipe (from top of earth plate up to the test point) by means of GI bolts, nuts, check nuts and washers of GI and thimbles, earth plate surrounded by packed layers of charcoal dust and common salt 15cm thick, all around including top and bottom and watering pipe 20mm bore of GI pipe medium grade with funnel and wire mesh, PCC chamber of size 300x300x300mm(top of chamber minimum 15 cm above the normal ground level (1:3:6) using 20mm graded stone aggregate and RCC cover (1:2:4) type B-I using 20mm graded crushed stone aggregate of 25mm thick with 1 no MS handles of 12mm dia including necessary excavation/ earth work in any type of soil/rock and as shown in Electrical plate No. 3 of SSR Part-I (2009) testing on completion complete all as specified. Note : If result is not satisfactory then contractor will do 2nd earthing on his own cost
Material and labour for scraping old paint from LT panels/ feeder pillars off size with emery paper, preparing old surface for painting, applying two coats of synthetic enamel paint in steel grey/ blue from top of PCC coping and marking number/ name of panel and feeders in alphabets not less than 150mm in size complete all as specified & directed. Note : Colour and number/ name of panel shall be decided by Engineer-in-Charge
Material and labour for applying two coats of synthetic enamel paint in silver from top of PCC coping/ brick work to chain link fencing (structure of any size) inside and outside around transformers/ LT panels/ feeder pillars off size and angle iron/ cross arms of fencing including white washing the brick work of fencing complete all as specified and directed
Material and labour preparation of old painted surface of steel tubular poles straight/ swan neck and applying two coats of synthetic enamel paint in alternate black & white strips of 30cm each upto 1.5 mtr height from top of PCC coping and numbering of poles in alphabets of size not less than 150mm height, including two coats of aluminium paint to remaining part of poles above strips including painting of street light brackets, clamps and numbering the pole complete all as specified and directed
Material and labour for replacement of heavy duty cylindrical type power factor correction MPP capacitors of capacity 5 KVAR complete all as specified
All as per srl item No 37.00 here-in-before but of capacity 7.50 KVAR
All as per srl item No 37.00 here-in-before but of capacity 12.50 KVAR
All as per srl item No 37.00 here-in-before but of capacity 20 KVAR
Material and labour in replacement TPN MCB, 240 Volts, 50 Hz, having rupturing capacity 10 KA, of rating 32 Amps complete all as specified and directed.
Material and labour in replacement TP MCB, 240 Volts, 50 Hz, having rupturing capacity 10 KA, of rating 63 Amps complete all as specified and directed.
Supply and fixing in replacement 4 pole contactors (heavy duty) with inbuilt auxiliary contacts AC 415 volts ratings 32 Amps complete all as specified.
Supply and fixing in replacement 4 pole contactors (heavy duty) with inbuilt auxiliary contacts AC 415 volts ratings 40 Amps complete all as specified.
Supply and fixing in replacement microprocessor based automatic power factor control relay unit suitable for eight stages capacitor bank complete all as specified and directed.
Material and labour for replacing MCCB 630 Amps, 3 pole, with thermal magnetic release, 415 volts, 50 HZ, 36 KA complete all as specified and directed.
Material and labour for replacing MCCB 400 Amps, 3 pole, with thermal magnetic release, 415 volts, 50 HZ, 36 KA complete all as specified and directed.
Supply and fixing in replacement MCCB 250 Amps, 3 pole with thermal magnetic release, 415 volts, 50Hz, 25KA complete all as specified.
Material and labour for replacing indicator with neon lamps for colour Red/Yellow/Blue complete all as specified
Supply and fixing in replacement CT suitable for 415 volts, 50 HZ LT supply of ratio 100/5 A complete all as specified
Supply and fixing in replacement CT suitable for 415 volts, 50 HZ LT supply of ratio 200/5 A complete all as specified
Supply and fixing in replacement CT suitable for 415 volts, 50 HZ LT supply of ratio 400/5 A complete all as specified
Material and labour for replacement of copper cable for connection in LT panels of size 16 sqmm single core duly crimped with copper thimbles complete all as specified and directed (Cost of copper thimbles and crimping included in the quoted rate).
Material and labour for replacement of copper cable for connection in LT panels of size 6 sqmm single core duly crimped with copper thimbles complete all as specified and directed. (Cost of copper thimbles and crimping included in the quoted rate).
Material and labour for replacement of copper cable for connection in LT panels of size 2.5 sqmm single core duly crimped with copper thimbles complete all as specified and directed. (Cost of copper thimbles and crimping included in the quoted rate).
Boring hole under the road/ pavement/ hard standing with the help of trenchless technology 150mm bore HDPE pipe including provision of HDPE pipe at a depth not less than one metre below ground level complete all as specified & directed. Note: HDPE pipe 150mm shall be included and paid in quoted rate.
Supply and fixing LED street light luminaire 45 watt in epoxy powder coated pressure die-cast aluminium with potted isolated driver and high power LED and individual lances operating range 90-340 Volts fixture should with stand 320V upto 48 Hrs auto cut off > 320V and restart 440 V sustain upto 8 Hrs external SPD-10 KV and 4 KV inbuilt in driver. Brand name should be embossed on fixture to ensure Indian brand only complete all as specified and directed
Material and labour for replacement of digital time switch suitable for mounting on DIN rail astronomical type programmable every 1 min, current capacity 16A, with 2 change over complete all as specified and directed.
Material and labour in replacement sheet metal enclosures/ polycarbonate housing with astronomical digit time switch, contractor 32 Amp 3 Pole, MCB TPN 63 Amp, control wiring, fuse, Din rail with suitable size clamp complete all as specified and directed
Material and labour in repair dismantling the all cables of any size from any type LT panel, taking out the cable loop stretching out the cable, carrying out end termination with new lugs, proper thimbling/ crimping, connecting back to the panel board of any size any type and as directed by Engineer-in-Charge Note : The rate quoted includes necessary excavation to take out the loop and laying the cable , putting proper cable protection bricks using the old retrieved bricks and refill the area properly and spreading any surplus soil. The end jointing kit replaced shall be measured and paid under relevant items of Sch. Work carried on one single panel shall be measured as one unit
Supply and fixing in replacement aluminium thimbles suitable for 120 Sqmm underground cable, crimping and connecting with MCCB complete all as specified and directed
All as per srl item No. 61.00 but for 185 Sqmm
All as per srl item No. 61.00 but for 35 Sqmm
Material and labour for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 20x15cm size complete all as specified and directed
Material and labour for danger notice plate of 1.6mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with M.S. clamps, bolts and nuts of approved size, for LT, 25x20cm size complete all as specified and directed
S & F SPD (Surge Protection Device) suitable for LED street light fitting 45 watt/70 watt to avoid surge protection voltage upto 10 KV complete all as specified and directed
CHOUDHARY AND SONS
AGGARWAL ENGINEERING CO
Bains Enterprises
Northern cable fault locatoers
KULDEEP SINGH
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .