Special Repairs to Roof Leakage and water supply arrangements in Health Sub Center Building at Rajenthiraasolagan in Cuddalore Distict.
2026_PWD_698052_1
TN3-5/2026-2027/Dt 25.08.2026
Open Tender
Civil Works - Buildings
Lump-sum
90 days
Rajenthiraasolagan
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹3,000
26 Aug 2026
26 Aug 2026
9 Sept 2026
26 Aug 2026
8 Sept 2026
26 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Clean removal of Cement plaster from walls etc., complete complying with standard specifications. | 324.18 | Sq.m | - | - |
| 2 | Earth work Open excavation by Mechanical Means for Open Earthwork in all soils and sub-soils and to full depth as may be directed except in rock requiring blasting inclusive of shoring shuttering, bailing out water wherever necessary and depositing the surplus earth within the compound in places shown by the departmental officers with an initial lead of 100 mts and clearing and levelling including dressing of sides and raming of bottoms etc., complete complying with standard specification and as directed by the departmental officers. Upto 2.40m Depth Data worked out for 64 m3 per day/8 hrs. | 2.65 | Cu.m | - | - |
| 3 | Supplying and filling in foundation, basement, etc with filling crushed stone sand in layers of not more than 15 cm thick well watered, rammed and consolidated etc. complete complying with standard specification and as directed by the departmental officers. | 0.52 | Cu.m | - | - |
| 4 | Cement Concrete 1:5:10 (One Cement, Five crushed stone sand and Ten hard broken stone jelly) using 40 mm gauge hard broken granite stone jelly for foundation including dewatering wherever necessary and laid in layers of not more than 15 cm thick well rammed, consolidated and including curing etc. complete complying with standard specification and as directed by the departmental officers -Mixing by mechanical means | 0.52 | Cu.m | - | - |
| 5Manufacturing, supplying and fixing Precast Reinforced Cement Concrete slabs of following thickness in RCC 1:2:4 (one cement, two crushed stone sand and four aggregates), using following HBGS jelly excluding cost of reinforcement steel in position but including cost of moulding charges, casting of slab, finishing, curing and fixing in position in all floors etc., complete complying with standard specification and as directed by the departmental officers. | |||||
| 5.01 | For 75mm thick | 8.84 | Sq.m | - | - |
| 6 | Providing and Applying of Solar reflective Paint, acrylic polymer based elastometric water proofing coating having Solar Reflective Index more than 90 % as per ASTM E 903, specific Gravity of 1.30+/-0.10. For Existing Surface: The Surface Preparation including Jet wash , the Cracks are filled wherever required below 3mm of crack and application of three coats of paint to form 1mm thickness | 71.24 | Sq.m | - | - |
| 7Supplying and fixing in position best quality PVC soil / waste pipes of various dia having 6 kg / sq.cm. pressure BIS mark and providing leak proof joints using PVC adhesives including fixing to the wall with special PVC / MS clamp, teak wood plugs, brass screws, etc., and making connection to all sanitary fittings, dismantling masonry / RCC works wherever found necessary and making the good dismantled portion to the original condition, including testing for any leakages, etc., complete complying with standard specifications. (The PVC pipes should be got approved by the Executive Engineer before use on works). The rate for earth work excavation will be measured and paid separately in the cases where the pipe lines are proposed to laid below ground level | |||||
| 7.01 | 110mm dia PVC soil / waste pipe | 10 | Rm | - | - |
| 8Supplying, laying and jointing UPVC pipes of Class 6 (having working pressure of 12.50kg/sq.cm) conforming to IS 4985- 2000 of approved quality and best variety conforming to BIS of the following dia including cutting and fixing UPVC specials using UPVC adhesives (but excluding cost of such specials) in accordance with IS 7634-3 (2003) and fixing into wall with teak wood plugs, PVC clamps and screws making holes on the wall (or) drilling holes in the roof and making good the dismantled portion to original condition with necessary brick work / cement concrete and plastering neatly wherever necessary with necessary scaffolding charges upto 4 metre height above ground level, etc., complete complying with standard specifications. The PVC pipes shall be got approved by Executive Engineer before use on works - External water supply above ground level / Above ground level. | |||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.21 MB
Tenderconditions5.pdf
Tender Documents • 1.14 MB
BOQ_839126.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].