Tender Value
₹2.2 Cr
EMD Value
₹4.4 L
Closing Date
30 Sept 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TENDER
20 conditions · 9 needing a document upload
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. [As per GCC April 2022 Advance Correction Slip No. 1]
Tenderer should submit their bank account no., name of the bank and bank specific code no. in separate sheet, Current valid GST registration no. and PAN CARD.
Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' shall be exempted from payment of Bid Security detailed above. 2. Labour Cooperative Societies shall submit only 50% of above Bid Security detailed above.
The tenderer are advised to submit the Bid Security with the tender for the due performance with the stipulation to keep the offer open till such date as specified in the tender, under the conditions of tender. The Bid Security shall be deposited either in cash through e payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure-VIA and shall be valid for a period of 90days beyond the bid validity period.
It is necessary for tenderer that the following details may be entered into SFMS while issuing bank guarantee for tenderer in Favour of railways: IFSC CODE SBIN000RAIL IFSC TYPE BRANCH BANK NAME STATE BANK OF INDIA BRANCH NAME RAIL CITY NAME NAVI MUMBAI ADDRESS SECTOR- 11, CBD BELAPUR, NAVI MUMBAI DISTRICT NAVI MUMBAI STATE MAHARASHTRA BG ENABLED Y E S This IFSC code is only valid for BG issuance and verification in favour of railways.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, super structure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii)One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfilment of technical eligibility criteria for different components.
Similar nature of work : Supply, installation, testing and commissioning of any LT/HT Electrical work
In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract, with prior approval of Chief Engineer in writing. Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate.
Tenderer must have to submit valid Electrical Contractor license as per Indian Electricity Rules for the respective category of works issued by Government Electrical License Board on or before closing date of tender. Copy of whichshould be submitted along with the tender offer, otherwise tender will be summarily rejected. Tenderer should also submit letter of confirmation of employment of electrical supervisor along with current and valid electrical supervisor license of the engaged supervisor for the respective category of works, otherwise tenderer offer would summarily rejected.
30 conditions · 7 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
i)The Tenderer is hereby advised to study the tender document in www.ireps.gov.in portal carefully and may also ascertain the nature quantum of work and working condition before submission of his offer. (ii) The submission of the tender will be deemed to imply that this memorandum and all documents enclosed have been studied and understood and that the Tenderer is aware of the full scope of the work to be done.
In case, submission of Bid Security in the form of Bank Guarantee, following shall be ensured: i. A scanned copy of the Bank Guarantee shall be uploaded on e-Procurement Portal (IREPS) while applying to the tender. ii. The original Bank Guarantee should be delivered in person to SSE/Tender in the office of Dy.CEE/PS/MLG/HQ, Maligaon within 5 working days before closing date for submission of bids. iii. Non submission of scanned copy of Bank Guarantee with the bid on e-tendering portal (IREPS) and/or non submission of original Bank Guarantee within the specified period shall lead to summary rejection of bid. iv. The Tender Security shall remain valid for a period of 90 days beyond the validity period for the Tender. v. The details of the BG, physically submitted should match with the details available in the scanned copy and the data entered during bid submission time, failing which the bid will be rejected vi. The Bank Guarantee shall be placed in an envelope, which shall be sealed. The envelope shall clearly bear the identification "Bid for the ***** Project" and shall clearly indicate the name and address of the Bidder. In addition, the Bid Due Date should be indicated on the right hand top corner of the envelope. vii. The envelope shall be addressed to the officer and address as mentioned in the tender document. viii. If the envelope is not sealed and marked as instructed above, the Authority assumes no responsibility for the misplacement or premature opening of the contents of the Bid submitted and consequent losses, if any, suffered by the Bidder.
The tenderers shall submit a copy of certificate stating that all their statements/documents submitted along with bid are true and factual. Standard format of certificate to be submitted by the bidder is enclosed as Annexure-V. In addition to Annexure- V, in case of other than Company/ Proprietory firm, AnnexureV(A) shall also be submitted by each member of a Partnership Firm/ Joint Venture (JV)/ Hindu Undivided Family (HUF)/ Limited Liability Partnership (LLP) etc as the case may be. Non submission of above certificate(s) by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested/digitally signed by which they/he is qualifying the Qualifying Criteria mentioned in the Tender Document.
The Tenderer(s) shall keep the offer open for a minimum period of 60 days from the date of closing of the Tender. It is understood that the tender documents have been issued to the Tenderer(s) and the Tenderer(s), is / are permitted to tender in consideration of the stipulation on his / their part that after submitting his / their tender subject to the period being extended further, if required by mutual agreement from time to time, he will not resile from his offer or modify the terms and conditions thereof in a manner not acceptable to ___________Railway. Should the tenderer fail to observe or comply with the foregoing stipulation, the amount deposited or Bank guarantee bond submitted as Bid Security for the due performance of the above stipulation, shall be forfeited to the Railway.
Compliance with the GST Act, 2017 under Clause No.6 of GCC- 2022 (Care In Submission of Tenders :)(a) (i)Before submitting a tender, the tenderer will be deemed to have satisfied himself by actual inspection of the site and locality of the works, that all conditions liable to be encountered during the execution of the works are taken into account and that the rates he enters in the tender forms are adequate and all-inclusive to accord with the provisions in Clause-37 of the Standard General Conditions of Contract for the completion of works to the entire satisfaction of the Engineer. (a)(ii)Tenderers will examine the various provisions of The Central Goods and Services Tax Act, 2017(CGST)/ Integrated Goods and Services Tax Act, 2017(IGST)/ Union Territory Goods and Services Tax Act, 2017(UTGST)/ respective state's State Goods and Services Tax Act (SGST) also, as notified by Central/State Govt.& as amended from time to time and applicable taxes before bidding. Tenderers will ensure that full benefit of Input Tax Credit (ITC) likely to be availed by them is duly considered while quoting rates. (a)(iii) The successful tenderer who is liable to be registered under CGST/IGST/UTGST/SGST Act shall submit GSTIN along with other details required under CGST/IGST/UTGST/SGST Act to railway immediately after the award of contract, without which no payment shall be released to the Contractor. The Contractor shall be responsible for deposition of applicable GST to the concerned authority. (a)(iv)In case the successful tenderer is not liable to be registered under CGST/IGST/UTGST/ SGST Act, the railway shall deduct the applicable GST from his/their bills under reverse charge mechanism (RCM) and deposit the same to the concerned authority. (b)When work is tendered for by a firm or company, the tender shall be signed by the individual legally authorized to enter into commitments on their behalf. (c)The Railway will not be bound by any power of attorney granted by the tenderer or by changes in the composition of the firm made subsequent to the execution of the contract. It may, however, recognize such power of attorney and changes after obtaining proper legal advice, the cost of which will be chargeable to the Contractor.
Documents to be Submitted Along with Tender (i)The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc. The tenderer(s) shall enclose the attested copies of the constitution of their concern, and copy of PAN Card along with their tender. Tender Documents in such cases are to be signed by such persons as may be legally competent to sign them on behalf of the firm, company, association, trust or society, as the case may be. Documents that shall be submitted in case of (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) will be as mentioned in the tender document.
Security Deposit: The Security Deposit shall be 5% of the contract value. The Bid Security submitted by the Contractor with his tender will be retained/encashed by the Railways as part of security for the due and faithful fulfillment of the contract by the Contractor. Provided further that, if Contractor submits the Cash or Term Deposit Receipt issued from a Scheduled commercial bank of India or irrevocable Bank Guarantee Bond from a Scheduled commercial bank of India, either towards the Full Security Depositor the Part Security Deposit equal to or more than Bid Security, the Railway shall return the Bid Security, to the Contractor. Balance of Security Deposit may be deposited by the Contractor in cash or Term Deposit Receipt issued from Scheduled commercial bank of India or irrevocable Bank Guarantee bond issued from Scheduled commercial bank of India, or may be recovered at the rate of 6% of the bill amount till the full Security Deposit is recovered. Provided also that in case of defaulting Contractor, the Railway may retain any amount due for payment to the Contractor on the pending "on account bills" so that the amounts so retained (including amount guaranteed through Performance Guarantee) may not exceed 10% of the total value of the contract. The Irrevocable Bank Guarantee submitted towards Security deposit shall be initially valid up to the stipulated date of Maintenance period plus 60 days and shall be extended from time to time, depending upon extension of contract granted in terms of Clause 17A and 17B of the Standard General Conditions of Contract. Note: Security Deposit deposited in cash by the Contractor or recovered from the running bills of a Contractor or submitted by contractor as Term Deposit Receipt(s) can be refunded/returned to the contractor, in lieu of irrevocable Bank Guarantee bond issued from scheduled commercial bank of India, to be submitted by him, for an amount equal to or more than the already available Security Deposit, provided however that, in a contract of value less than Rs. 50 Crore, such refund/ return of the already available Security Deposit is permitted up to two times and in a contract of value equal to or more than Rs. 50 Crore, such refund / return of the already available Security Deposit is permitted up to three times.
Refund of Security Deposit: Security Deposit mentioned in sub clause (1) above shall be returned to the Contractor along with or after, the following: (a)Final Payment of the Contract as per clause 51.(1) and (b) Execution of Final Supplementary Agreement or Certification by Engineer that Railway has No Claim on Contractor and (c) Maintenance Certificate issued, on expiry of the maintenance period as per clause 50.(1), in case applicable. 16. (2) (ii) Forfeiture of Security Deposit: Whenever the contract is rescinded as a whole under clause 62 (1) of these conditions, the Security Deposit already with railways under the contract shall be forfeited. However, in case the contract is rescinded in part or parts under clause 62 (1) of these conditions, the Security Deposit shall not be forfeited. 16.(3) No interest shall be payable upon the Bid Security and Security Deposit or amounts payable to the Contractor under the Contract, but Government Securities deposited in terms of Sub Clause 16.(4) (b) of this clause will be payable with interest accrued thereon.
Performance Guarantee The procedure for obtaining Performance Guarantee is outlined below: (a) The successful bidder shall have to submit a Performance Guarantee (PG) within 21 (Twenty one) days from the date of issue of Letter of Acceptance (LOA). Extension of time for submission of PG beyond 21 (Twenty one) days and upto 60 days from the date of issue of LOA may be given by the Authority who is competent to sign the contract agreement. However, a penal interest of 12% per annum shall be charged for the delay beyond 21(Twenty one) days, i.e. from 22ndday after the date of issue of LOA. Further, if the 60thday happens to be a declared holiday in the concerned office of the Railway, submission of PG can be accepted on the next working day. In all other cases, if the Contractor fails to submit the requisite PG even after 60 days from the date of issue of LOA, the contract is liable to be terminated. In case contract is terminated railway shall be entitled to forfeit Bid Security and other dues payable to the contractor against that particular contract, subject to maximum of PG amount. In case a tenderer has not submitted Bid Security on the strength of their registration as a Startup recognized by Department of Industrial Policy and Promotion (DIPP) under Ministry of Commerce and Industry, DIPP shall be informed to this effect. The failed Contractor shall be debarred from participating in re-tender for that work. (b) The successful bidder shall submit the Performance Guarantee (PG) in any of the following forms, amounting to 5% of the original contract value:- (i) A deposit of Cash; (ii) Irrevocable Bank Guarantee.
(iii) Government Securities including State Loan Bonds at 5% below the market value; (iv) Pay Orders and Demand Drafts tendered by any Scheduled Commercial Bank of India; (v) Guarantee Bonds executed or Deposits Receipts tendered by any Scheduled Commercial Bank of India; (vi) Deposit in the Post Office Saving Bank; (vii) Deposit in the National Savings Certificates; (viii) Twelve years National Defence Certificates; (ix) Ten years Defence Deposits; (x) National Defence Bonds and (xi) Unit Trust Certificates at 5% below market value or at the face value whichever is less. Also, FDR in favour of FA&CAO (free from any encumbrance) may be accepted. (c) The Performance Guarantee shall be submitted by the successful bidder after the Letter of Acceptance (LOA) has been issued, but before signing of the contract agreement. This P.G. shall be initially valid upto the stipulated date of completion plus 60 days beyond that. In case, the time for completion of work gets extended, the Contractor shall get the validity of P.G. extended to cover such extended time for completion of work plus 60 days. (d) The value of PG to be submitted by the Contractor is based on original contract value and shall not change due to subsequent variation(s) in the original contract value. (e) The Performance Guarantee (PG) shall be released after physical completion of the work based on 'Completion Certificate' issued by the competent authority stating that the Contractor has completed the work in all respects satisfactorily. (f) Whenever the contract is rescinded, the Performance Guarantee already submitted for the contract shall be encashed. (g) The Engineer shall not make a claim under the Performance Guarantee except for amounts to which the President of India is entitled under the contract (not withstanding and/or without prejudice to any other provisions in the contract agreement) in the event of: (i) Failure by the Contractor to extend the validity of the Performance Guarantee as described herein above, in which event the Engineer may claim the full amount of the Performance Guarantee. (ii) Failure by the Contractor to pay President of India any amount due, either as agreed by the Contractor or determined under any of the Clauses/Conditions of the Agreement, within 30 days of the service of notice to this effect by Engineer. (iii) The Contract being determined or rescinded under clause 62 of these conditions.
Force Majeure Clause: If at any time, during the continuance of this contract, the performance in whole or in part by either party of any obligation under this contract shall be prevented or delayed by reason of any war, hostility, acts of public enemy, civil commotion, sabotage, serious loss or damage by fire, explosions, epidemics/pandemics, strikes, lockouts or acts of God (hereinafter, referred to events) provided, notice of the happening of any such event is given by either party to the other within 30 days from the date of occurrence thereof, neither party shall by reason of such event, be entitled to terminate this contract nor shall either party have any claim for damages against the other in respect of such non-performance or delay in performance, and works under the contract shall be resumed as soon as practicable after such event has come to an end or ceased to exist, and the decision of the Engineer as to whether the works have been so resumed or 50 shall be final and conclusive, PROVIDED FURTHER that if the performance in whole or in part of any obligation under this contract is prevented or delayed by reason of any such event for a period exceeding 120 days, either party may at its option terminate the contract by giving notice to the other party.
New tax structure is applicable as per GST Act, implemented w.e.f 01.07.2017
For more details the instruction to tenderers and all other details available in the documents attached with tender may be referred to.
A)Electrical work in connection with Construction of 10 units Type-II DS Quarters at Goshala Colony under the jurisdiction of SSE/W/NMB in replacement of Qtr Nos. 93(C+D), 94(A+B+C+D) & 95(A+B+C+D) Type-I of Goshala Colony. B)Electrical work in connection with Construction of 10 units Type-II DS Quarters at Goshala Colony under the jurisdiction of SSE/W/NMB in replacement of Qtr Nos. 98(C+D), 99(A+B+C+D) &100(A+B+C+D) Type-I of Goshala Colony. C)Electrical work in connection with Construction of 10 units Type-II DS Quarters at Goshala Colony under the jurisdiction of SSE/W/NMB in replacement of Qtr Nos. 91(A+B+C+D), 92(A+B+C+D) & 93(A+B) Type-I of Goshala Colony. D)Electrical work in connection with Construction of 10 units Type-II DS Quarters at Goshala Colony under the jurisdiction of SSE/W/NMB in replacement of Qtr Nos. 96(A+B+C+D), 97(A+B+C+D) &98(A+B) Type-I of Goshala Colony. E) At MLG : Electrical work in connection with Construction of 12 units Type-II DS Quarters at Central Gotanagar Colony under the jurisdiction of SSE/W/HQ in replacement of Qtrnos. 113(A+B+C+D) , 115(A+B+C+D) & 116(A+B+C+D) Type-I of Central Gotanagar Colony. F)At MLG : Electrical work in connection with Construction of 10 units Type- II DS Quarters at Central Gotanagar Colony under the jurisdiction of SSE/W/HQ in replacement of Qtr nos 117(A+B+C+D+E+F+G+H) & 119(C+D) Type-I of Central Gotanagar Colony. G) Electrical work in connection with Construction of 10 units Type-II DS Quarters at Central Gotanagar Colony under the jurisdiction of SSE/W/HQ in replacement of Qtr nos 114(A+B+C+D+E+F+G+H) & 119(A+B) Type-I of Central Gotanagar Colony.
DYCEE-PS-MLG-HQ-10-26-27~NFR
DYCEE-PS-MLG-HQ-10-26-27
Open
Works - General
180 Days
Kamrup, Assam
₹0
₹4.4 L
9 Sept 2026
9 Sept 2026
16 Sept 2026
251 items across 7 schedules · ₹2,18,46,516 total
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| 1 | Supply, Wiring of concealed light point by PVC insulated unsheathed and multi- stranded FRLS Copper Cable 1.5 sq.mm S/C confirming to IS - 694 through suitable size (19 mm) of PVC Concealed rigid Conduit pipe of wall thickness 2mm including 10AX One- way modular switch on 1/2 M concealed unbreakable GI modular box, 2 M cover plate etc. with all accessories and ceiling rose /holder.etc. as required. | Numbers | 80.00 | 386 | 30,880 |
| 2 | Supply ,Wiring of concealed ceiling fan point by PVC insulated unsheathed and multi stranded FRLS Copper Cable 1.5 sq.mm S/C confirming to IS - 694 through suitable size (19 mm) of PVC Concealed rigid Conduit pipe of wall thickness 2mm and ceiling rose, wire as required and 10 AX one-way modular switch, 4 step energy saving electronic BLDC fan compatible regulator on 1/2 M concealed unbreakable GI modular box, 2 M cover plate etc. with 1sq. mm unsheathed copper cable as earth continuity wire with all accessories and ceiling rose etc. as required. | Numbers | 30.00 | 785 | 23,550 |
| 3 | Supply; Wiring of concealed exhaust/wall bracket fan point by PVC insulated unsheathed and multi stranded FRLS Copper Cable 1.5sq.mm S/C confirming to IS - 694/1990 through suitable size (19 mm) of PVC Concealed rigid Conduit pipe of wall thickness 2mm including ceiling rose and 10 AX one way modular switch in 1/2 M concealed unbreakable GI modular box, 2 M cover plate etc. with 1sq. mm unsheathed copper cable as earth continuity wire. | Numbers | 30.00 | 419 | 12,570 |
| 4 | Supply, wiring of concealed 6 Amps plug socket point with 2.5 sq mm S/C PVC insulated unsheathed and multi-stranded FRLS Copper Cable through suitable size (19mm) of PVC casing capping of suitable size with 10AX one-way modular switch and 6Amp 5 pin shuttered socket on 3 M concealed unbreakable GI modular box, 3 M cover plate etc. with 1 sq. mm unsheathed copper cable as earth continuity wire. | Numbers | 50.00 | 508 | 25,400 |
| 5 | Supply, wiring of concealed 16 Amps plug socket point with 4 sq mm S/C PVC insulated unsheathed and multi-stranded FRLS Copper Cable through suitable size (19mm) of PVC Concealed rigid Conduit pipe of wall thickness 2mm of suitable size with 16AX One-way modular switch on 3 M concealed unbreakable GI modular box, 3M cover plate etc. with 1 sq. mm unsheathed copper cable as earth continuity wire. | Numbers | 80.00 | 644 | 51,520 |
| 6 | Supply & Wiring of Call Bell point concealed including call bell by PVC insulated unsheathed and multi-stranded FRLS Copper Cable 1.5sq.mm S/C confirming to IS - 694/1990 through suitable size (19mm) PVC rigid Conduit pipe of wall thickness 2mm of suitable size with 10 A Mega one-way bell push switch including 2 M calling bell buzzer with 1/2M concealed unbreakable GI modular box, 2 M cover plate etc. & ceiling rose etc as per site requirement. | Numbers | 10.00 | 564 | 5,640 |
| 7 | Supply & wiring of concealed water heater (geyser) point through suitable size (19mm) of PVC Concealed rigid Conduit pipe by 2x4 sq.mm PVC insulated unsheathed and multi- stranded FRLS copper cable duly fitted on wall complete with 1 no. 16 AX One-way modular switch, 6-16 A 3 pin shuttered socket with 1/2M concealed unbreakable GI modular box, 2 M cover plate etc. as required at site as per direction of site Engineer. | Numbers | 10.00 | 707 | 7,070 |
| 8 | Supply & wiring of RAC point through suitable size (19mm) of PVC Concealed rigid Conduit pipe by 2x 4 sq.mm PVC insulated unsheathed and multi-stranded FRLS copper cable on wall complete with 1 No. 25 A motor starter switch, 1 No. 32A SP mini MCB, C- series, 3kA, 6-16 A 3 pin shuttered socket with 3M concealed unbreakable GI modular box, 3 M cover plate etc. as required at site including 1sq. mm unsheathed copper cable as earth continuity wire. | Numbers | 30.00 | 1,111 | 33,330 |
| 9 | Supply, fitting, fixing and testing of indoor surface mounting 1x18/20 watts (4ft.) LED batten tube light fitting complete with lamp and other accessories along with connection of flexible copper cable etc. as per direction of site engineer in-charge. Lumens output should be greater than 100 Lumens/watt. LED driver's efficiency should be minimum 90% .Power factor of complete fitting should be greater than 0.90, Input operating voltage: 140V to 277V AC. | Numbers | 40.00 | 344 | 13,760 |
| 10 | Supply, fixing, testing and commissioning of super energy efficient BLDC electric ceiling fan of 32W having BEE five star rating, 1400mm sweep, 230V AC 50HZ, speed 320 RPM with compatible remote control including fixing arrangement by allied engineering works. | Numbers | 30.00 | 2,840 | 85,200 |
| 11 | Supply, fitting, fixing and testing 9 watts LED bulb with batten holder and other accessories along with connection of flexible copper cable etc. as per direction of site engineer in-charge. | Numbers | 40.00 | 283 | 11,320 |
| 12 | Supply and wiring of sub- main line concealed by 2x10 sq. mm. PVC insulated unsheathed and multi stranded FRLS Copper Cable confirming to IS 694/1990 through suitable size of PVC conduit pipe with 1sq. mm unsheathed copper cable as earth continuity wire . | RM | 200.00 | 180 | 36,000 |
| 13 | Supply and wiring of sub- main line concealed by 2x 6 sq. mm. PVC insulated unsheathed and multi stranded FRLS Copper Cable confirming to IS 694/1990 through suitable size of PVC conduit pipe with 1sq. mm unsheathed copper cable as earth continuity wire. | RM | 500.00 | 132 | 66,000 |
| 14 | Supply and wiring of sub- main line concealed by 2x 4 sq. mm. PVC insulated unsheathed and multi stranded FRLS Copper Cable confirming to IS 694/1990 through suitable size of PVC conduit pipe with 1sq. mm unsheathed copper cable as earth continuity wire. | RM | 500.00 | 102 | 51,000 |
| 15 | Supply and wiring of sub- main line concealed by 2x2.5 sq. mm. PVC insulated unsheathed and multi stranded FRLS Copper Cable confirming to IS 694/1990 through suitable size of PVC conduit pipe with 1sq. mm unsheathed copper cable as earth continuity wire. | RM | 2000.00 | 83 | 1,66,000 |
| 16 | Supply , installation, testing and commissioning of indoor type, grey colour 12 way SPN Distribution Board Double (Metal) door having A.Supply, installation, testing and commissioning of 1 No. 63 amps., 2P- RCCB with over current protection.B.Supply, installation, testing and commissioning of 02 Nos. 20Amps B/C-curve, 10KA 2P MCB &C.Supply, installation, testing and commissioning of 02 Nos 10Amps B/C-curve, 10KA SP MCB .D.Supply, installation, testing and commissioning of 02 Nos 16Amps B/C- curve, 10KA SP MCB including internal connection of suitable copper cable / strip to be provided as per direction of site Engineer in-charge of Railway. | Set | 10.00 | 9,229 | 92,290 |
| 17 | Supply, erection of earthing set by Class "A" 50 mm Dia GI pipe 3 Mts. long including construction of earth pit with cover and earth continuity by (25x3)mm GI strip , GI nuts and bolts etc. as per direction at site Engineer. | Set | 10.00 | 2,218 | 22,180 |
| 18 | Supply, erection, testing & commissioning of 300 mm sweep High speed air flow exhaust fan suitable for single phase 230 volt AC supply including fixing arrangement by allied engineering works as per direction at site Engineer. | Numbers | 24.00 | 1,676 | 40,224 |
| 19 | Supply, erection & commissioning of Single longitudinal welding Single dipped Galvanizing Octagonal pole 6 Mts. long type - BOP-6030 with 70mm Top Diameter 130 mm Bottom Diameter and Steel thickness 3 mm as per ISO 9001 of 2000 & ISO14001 along with Decorative single arm including suitable base plate of size 220mmx220mmx12mm and cap on top including supply and construction of CC foundation work including Anchor type Foundation Bolts 4 Nos.20mm diameter & 600 mm length( 4 Nos. in one group) in C.C. foundation & 6 Amps SP MCB ,fixing of Bakelite Sheet terminals and 2x1.5 sq mm Cu cable for MCB to Street light fitting connection as per direction of site engineer. | Numbers | 4.00 | 18,066 | 72,264 |
| 20 | Dismantling old assets with all accessories without damage from the work site and handing over to concerned SSE office as per instruction of site Engineer in-charge of railway. | Job | 1.00 | 23,716 | 23,716 |
| 21 | Supply, fitting, fixing and testing of outdoor type 1 x 45 watts LED street light fitting complete with LED lamp and all other accessories including connecting cable etc. as per site requirement. Lumens output should be greater than 100 Lumens/watt. LED driver's efficiency should be minimum 90%, Power factor of complete fitting should be greater than 0.90, Input operating voltage: 140V to 277V AC. | Numbers | 4.00 | 2,724 | 10,896 |
| 22 | Supply, erection of earthing set by 80 mm diameter GI pipe medium gauge 4 Mts. long including construction of earth pit with cover as per site requirement and direction of site engineer in-charge. | Set | 6.00 | 3,323 | 19,938 |
| 23 | Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres . As DSOR Item No. 14.4 | Metre | 200.00 | 622 | 1,24,400 |
| 24 | Carrying, Laying, commissioning of cable of various size Aluminium armored XLPE cable, partly along the pole and partly through ground in cable trench with suitable fixing arrangement. Loading, unloading, carrying of cable to actual work site by contractor's own arrangement including supply and commissioning with suitable size of Lugs as per instruction of Engineer in-charge at site. (Cable will be supplied by Railway) | Metre | 1000.00 | 32 | 32,000 |
| 25 | Supply, installation, testing and commissioning of floor/ pedestal mounted Indoor type(IP44) single door LT Panel Board dust-vermin & corrosion proof, chemically treated, colour of panel shall be RAL 7035 structured finish , modular in construction made of suitable size, using CRCA Sheet Steel of 2mm thickness and are Epoxy powder coating having provision of cable alley in both sides with 1 set 3 phase with neutral (TPN) electrolytic grade 200A COPPER bus bar and bus bar system shall have heat shrinkable coloured PVC sleeve as per manufacturer specification /recommendation. All internal connection to be done by suitable size copper strip comprising of the following :-A.04 no. 63Amp, 2 pole, 10 KA B/C series MCB in the above LT panel board, connection of incoming supply of copper strips of suitable size from the bus bar andB. Provision for installation of 4 nos energy meter in above panel as per direction at site Engineer. C. Supply, installation, testing and commissioning of 01 nos heat- activated aerosol fire extinguishing device, DIN-rail mounted type, suitable for installation inside electrical MCB/DB panels distribution boxes, complete with heat- sensitive activation mechanism, aerosol extinguishing compound, mounting arrangement and all necessary accessories, conforming to relevant applicable standards and manufacturer's specifications, complete in all respects as required for a safe and operational installation.(Breaking capacity of all MCCB's should be Ics=100% Icu with adjustable magnetic settings.) | Set | 4.00 | 41,023 | 1,64,092 |
| 26 | Supply and erection of indoor type, cream color LT Feeder pillar with IP-44 protection dust-vermin & corrosion p r o o f , chemically treated modular in construction made of suitable size, using CRCA Sheet Steel of 2mm thickness made of suitable size, having 1 set 3 phase with neutral copper bus bar chamber capacity 120 Amps comprising with pillar consisting of 01 No. 100A 4P 36 KA thermal magnetic released based MCCB suitable for mounting in the above LT panel board as per requirement of site including internal connection should be stranded copper strips of suitable size from the bus bar to be provided as per direction at site Engineer . (Breaking capacity of all MCCB's should be Ics=100% Icu with adjustable magnetic settings.) | Set | 4.00 | 27,299 | 1,09,196 |
| 27 | Supply & commissioning of 63 (OD) mm diameter Double wall corrugated PN-6.0 Kgf/cm2 HDPE pipe partly through over ground & partly through underground including provision of necessary socket etc. as per direction of site engineer in-charge of Railway | Metre | 100.00 | 111 | 11,100 |
| 28 | Supply, laying, fitting, fixing & commissioning of 120 (OD) mm diameters Double wall corrugated PN-6.0 Kgf/cm2 HDPE Pipe partly through over ground & partly through underground including provision of necessary socket etc. as per direction of site engineer incharge of Railway. | Metre | 130.00 | 200 | 26,000 |
| 29 | Supply and erection of GI pipe 100mm diameter medium gauge proper clamp with pole by (50x6)mm MS flat with suitable size of bolt and nuts as per direction at site Engineer in-charge of railway . | Metre | 24.00 | 1,489 | 35,736 |
| 30 | Supply and erection of pedestal type outdoor type(IP54), cream color LT Panel Board (double door) modular in construction made of suitable size, using Sheet Steel of 2 mm having canopy at TOP and are Epoxy powder coated & having 1 set 3 phase with neutral copper bus bar chamber capacity 600 Amps comprising with the followings:-A.2 nos. 250 Amp, 4 pole, 36 KA Microprocessor based MCCB suitable for mounting in the above LT panel board, connection of incoming supply of copper strips of suitable size from the bus bar,B.4 No. 125 amps., Thermal magnetic release 4P MCCB suitable for mounting in the above LT panel board, connection of incoming supply of copper strips of suitable size from the bus bar,C. Supply, installation, testing, and commissioning of a 100g Condensed Aerosol-Based Automatic Fire Detection & Suppression System, complete with detection accessories, control unit, and integration connections to the LT Panel Board, including all required fixings, interlocks, and wiring as per project specs and manufacturer standards.The design of LV Panel shall be verified for Internal Arc compliance of minimum 80kA for 0.5 sec as per IEC 61641. The LV panel shall have provision for top/bottom incoming and bottom/top outgoing respectively to suit site conditions of cable entries (as per the site requirements to be specified by the End User during drawing approval) Minimum clearance between phases / live parts shall be 25 mm and phases/live parts/neutral to ground shall be 19 mm except on the equipment terminals. The busbars shall be supported of regular intervals using SMC or DMC insulators as per the tested design. It should have minimum Comparative Tracking Index (CTI) of 600 V as per IS 2824). The LV panel manufacturer (Franchise) shall be ISO 9001/9002 certified. The drawings of the LV Panels to be vetted with sign-stamp by the Switchgear OEM.(Breaking capacity of all MCCB's should be Ics=100% Icu with adjustable magnetic settings.) | Set | 1.00 | 2,26,369 | 2,26,369 |
| 31 | Supply, installation, testing & commissioning of SEMI INTEGRATED Solar Street Light SYSTEM (IP 65) of 30W. The solar luminary has aluminium pressure die cast (PDC) housing with efficacy 120 lm/w. 50% after 4 hrs burning each day & In built MPPT charge controller and PIR motion sensor for motion detection. Other Dimming options customizable through Bluetooth without any extra cost. LED luminaire, with an in-built lithium ferrous phosphate battery is connected with the PV panel and mounting clamp that can be ready to install. Monocrystalline Solar panel is mounted on top of the pole, luminaire arm, module mounting structure, 6 m GI Tubular pole and to be installed as per direction of site engineer. The Solar Street light system including Solar Module, Luminary, Battery must have a warranty of 5 years | Numbers | 14.00 | 54,210 | 7,58,940 |
| 32 | Supply, fitting, fixing and commissioning of 16 Watt LED Bollard fitting with energy saving, environmental friendly, long life aesthetically designed made in die-cast aluminum landscape having IP65 protection with high power LED as light source to be fitted on GI pipe 50 mm diameter of 3.0m length complete with driver circuit, lamp etc. and all accessories as per direction of Engineer In-charge at site. | Numbers | 14.00 | 7,083 | 99,162 |
| 33 | Design and supply of On-Grid connected Solar Photo Voltaic (PV) Plant without battery backup complete with the following items: a) Supply of 545 Wp or above solar SPV Module IEC Certified Mono crystalline Cell.; IEC: 61215/IS14286, Each PV module must use a RF identification tag (RFID); (Quantity may be adjusted according to the rating SPV module used). Warranty of module should be 25 years. b) On grid solar PCU/Inverter (three phase unit) with inbuilt LED display of appropriate capacity; Qty: suitable Nos.c) ACDB, PCDB, DC protection unit, AC protection unit, earthing, Lighting Arrestor, wires/cables, cable tray, connectors and all other accessories.d) Hot dipped galvanized iron Panel mounting structure e) Data Logger, with provision for data transferring ( RS-485, Wifi, GPRS, RF ) to remote service platform for data storage and analysis displayed in various visual and grafical formats on Web-App & big screen display with 5 Years Standard Warranty.f) Fire resistant DC Cables and Fire resistant AC cables of suitable size ( in sq.mm ) and length including dressing / laying of cable through suitable size GI covered cable tray / through HDPE Pipe / underground by Micro tunneling method / through GI pipe as per site requirement for connecting panels, array Junction box and solar inverter system, ACDB, GIP etc. including all other accessories such as monkey ladder for maintenance access to roof (if required), lightning arrester, suitable earthing arrangement along with installation, testing and commissioning of above Solar Photo Voltaic Modules on roof top of different service buildings, Shed top of Station Building & Platform, etc with all associated works. (The total quantity shall be installed in distributed manner having plant between >3KWp- Upto 10KWp)Note:- Operation & maintenance of 05 (Five)years including replacement of all parts cover under the guarantee, providing tools & tackles required for maintenance purpose along with required spare parts etc shall be the part of the contract for period of 05 (five) years from date of commissioning (as per MNRE guidelines) | KWp | 10.00 | 53,207 | 5,32,070 |
| 34 | Supply, installation, testing and commissioning of steel structure (made of ISMB steel, steel grade: FE-415) for additional mounting arrangement for installation of plated with south facing & painted with one coat of Red-oxide paint and two coats of aluminum paint) including erection of columns, thrust and all other required civil work/mechanical work of foundation for mounting of solar panels and shed for ACDB panels, and any other items or accessories such as galvanized nuts & bolts, weather proof gasket etc required for successful commissioning of Power Plant on "Single Responsibility" basis as per instructions given by Railway Site Engineer. | Kg | 440.00 | 214 | 94,160 |
| 35 | Supply, installation, testing & commissioning of 4W LED Updown outdoor wall light fitting, Warm White , Input Voltage Range: 100V - 300V AC, Luminous Efficacy: >90 Lm/W, Power Factor: >0.95, IP65 aluminium rated complete with all accessories as per site requirement and site engineer in-charge of Railway. | Numbers | 8.00 | 2,216 | 17,728 |
| Schedule total | ₹31,31,701 | ||||
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-2022.pdf
ATTACHMENT
correctionslip1to11compressed.pdf
ATTACHMENT
letterofcredit.pdf
ATTACHMENT
Annexures
ATTACHMENT
IIGoshala1210unittype-IICentralGTN-
ATTACHMENT
MicrosoftWord-ANNEXURES_August23to4thcorrectionslip.pdf
ATTACHMENT
10-Tenderdoccombined10unittype-IIGoshala1210unittype-IICentralGTN-1Final_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .