Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.9 CrAccepted-AOC A 2 45 JANAKPURI NEW DELHI 110058 | NEW DELHI | NEW DELHI | DELHI | 110058 | ₹37.9 Cr | L1 | Accepted-AOC Lowest and resonable |
| 2 | L2₹42.0 CrRejected-Finance | ₹42.0 Cr | L2 | Rejected-Finance Other than L1 |
| 3 | L3₹43.8 CrRejected-Finance 660 POLICE LINE AREA HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | ₹43.8 Cr | L3 | Rejected-Finance Other than L1 |
| 4 | L4₹46.2 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹46.2 Cr | L4 | Rejected-Finance Other than L1 |
| 5 | L5₹46.5 CrRejected-Finance CHINAR COMMERCIAL COMPLEX THE BUND RESIDENCY ROAD SRINAGAR 190 001 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190001 | ₹46.5 Cr | L5 | Rejected-Finance Other than L1 |
Tender Value
₹44.5 Cr
EMD Value
₹15 L
Closing Date
17 Dec 2024, 6:00 pmClosed
CHIEF ENGINEER JAIPUR ZONE JAIPUR
HEAD QUARTER CHIEF ENGINEER JAIPUR ZONE JAIPUR
PROVN OF KLP (PHASE-I) FOR AD REGT AT HISAR MIL STN
2024_MES_675123_1
80885
Open Tender
Civil Works
730 days
GE (E) Hisar
Pleases refer tender documents
7 documents required · 7 mandatory
₹3,000
GE (E) HISAR
₹15 L
Yes
HEAD QUARTER CHIEF ENGINEER JAIPUR ZONE JAIPUR
4 Feb 2025
18 Sept 2024
19 Dec 2024
18 Sept 2024
17 Dec 2024
12 Dec 2024
30 Sept 2024
Amount
Lump sum price worked out by the contractor for "BUILDING WORKS" as listed in Schedule ‘A’ Part-I representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "INTERNAL WATER SUPPLY " as listed in Schedule ‘A’ Part-II representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "INTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-III representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "ROAD, PATH AND CULVERT" as listed in Schedule ‘A’ Part-IV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "SEWAGE DISPOSAL" as listed in Schedule ‘A’ Part-V representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "AREA DRAINAGE " as listed in Schedule ‘A’ Part-VI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "FENCING AND GATE" as listed in Schedule ‘A’ Part-VII" representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "EXTERNAL WATER SUPPLY" as listed in Schedule ‘A’ Part-VIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES
Lump sum price worked out by the contractor for "EXTERNAL ELECTRIFICATION" as listed in Schedule ‘A’ Part-IX representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES
Lump sum price worked out by the contractor for "LIGHTENING PROTECTION" as listed in Schedule ‘A’ Part-X representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES
Lump sum price worked out by the contractor for " SUMMER APPLIANCES " as listed in Schedule ‘A’ Part-XI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "HOT WATER SUPPLY" as listed in Schedule ‘A’ Part-XII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price of prepriced by the MES
Lump sum price worked out by the contractor for " DG SET" as listed in Schedule ‘A’ Part-XIII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK" as listed in Schedule ‘A’ Part-XIV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "DEMOLITION WORK" as listed in Schedule ‘A’ Part-XV representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "FOOTBALL/ HOCKEY/BASKETBALL/VOLLYBALL/PARADE GROUND AND HARDSTANDING" as listed in Schedule ‘A’ Part-XVI representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Lump sum price worked out by the contractor for "POP FALSE CEILING" as listed in Schedule ‘A’ Part-XVII representing percentage ( + or - denomination) derived under last column of this schedule above/below the lump sum price prepriced by the MES
Sch 'A' Part-XVIII MISC ITEMS (TO BE QUOTED BY CONTRACTOR) Notes: (i) This schedule is not pre-priced by MES and the pre-priced rate indicated as "Rs 0.00" under column 5 signifies this fact only. (ii) Excavation and earth work except for the items which categorically includes for same shall be measured and paid separately under SCH A PART-XIV (SITE CLEARANCE, SITE DEVELOPMENT AND EARTH WORK schedule).
INTERNAL ELECTRIFICATION S&F of modular blanking plates 1 Module complete all as specified and directed
S&F of Sheet metal enclosure distribution board VTPN 4 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed
S&F of Sheet metal enclosure distribution board VTPN 6 way, 415 voltdouble door powder coated, protection class IP-54 isolated neutral bar, mechanical impact strength IK 09 suitable for mounting MCB & MCCB DBs confirming to IS - 13032, IS-8623, BS EN60898 with min 200 Amp rating copper bus bar and grouting, fixing on wall with nut bolts washers proper with PCC works complete all as specified and directed
Supply and fixing SP 63Amps rating 240V, 10KA 'B' curve rupturing capacity, IS-8828 marked fixing in DBs complete all as specified and directed. Note : (a) Make of the MCB should be the same as that of DB. (b) DBs shall be catered respective items of this schedule
Supply and fixing of MCB TPN 32 Amps, 415V plug & socket DB,s for 3 Phase connection as per IEC 61493-3, suitable for flush mounting and surface mounting suitable for protection of appliances like AC/Geyser etc. suitable with neutral links and win provision for mounting modular devices complete all as specified and directed.
S&F LED highbay light 70 W (or nearest higher Cap), suspended or surface type with very high efficiency in PDC housing suitable for sheds. The luminaries has efficacy 110Lm/W with Ingress protection of IP66 including connecting 3 core copper wire of size 1.5 Sqmm complete all as specified and directed
S & F for Highly efficient LED Bulbs, 9 watt complete all as specified and directed.
Supply, fixing and testing wall termination telephone socket RJ-11 complete all as specified and directed.
Supply and fixing (Concealed in wall) factory made flameproof DB duly painted, 4 way dust and vermin proof including with all accessories complete all as specifed and directed. (i) MCB 2Pole, 16/25 Amps, 10KA- 01 Nos(incoming) (ii) MCB 1Pole, 6/10 Amps, 10KA- 02 Nos(outcoming)
Supply and fix Rigid non-metallic PVC conduit exclusive of boxes (junction/terminal) but include of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nut, saddles, pipe hooks etc of size 40 mm dia complete all as directed
M&L for submain wiring alongwith earth wire with the 4x10.0sqmm + 1x10.0 sqmm earth wire sizes of FRLS PVC insulated copper conductor, single core cable in surface/recessed as required drawing into and including rigid non metallic PVC conduit, medium grade not less than 20mm dia ISI marked ivory colour with all conduit fittings and fixing accessories. (Note :- four runs of 10 Sqmm copper wire and one run of 10 sqmm copper earth wire alongwith PVC conduit shall be measured as one unit)
S&F LED Building Security Light energy efficient 25 Watt enviornmental friendly long life pressure die cast aluminium IP 66 protection luminous flux 2500lumen with high power leds as light source and electronic driver pre-wired complete with all necessary fittings and fixed on wall with suitable dia bend shape GI pipe light grade of approx length 1.0 mtr with clamp bolts & nuts etc. all as specified & directed.
Supply, jointing & testing 63mm bore steel water tubing, light grade, galvanised with and including necessary pipe fittings/accessories as cable protection laid in trench/floor, fixed on pole/wall etc. complete all as specified
ROAD PATH AND CULVERT S&F ABS Speed Breaker/Rumbler of height 50mm and width 380mm in two colour of length 500mm each fixed alternately with reflectors on either side complete fixed with epoxy and bolts by drilling 6mmx75mm dia fastener as per manufacture instruction complete all as specified and directed.
S&F convex mirror having 130 degree of viwing angle made of one piece polycarbonate lens size of 0.80 mtr dia protect with any type of light ray not prodice toxic fumes if burnt complete all as specified and directed.
EXTERNAL WATER SUPPLY 'Supply, lay, commissioning, jointing and testing of centrifugally cast (spun) ductile iron pipes of 200mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed at site of Following sizes:-. Note: The rate quoted by contractor are inclusive of all type of Joints.
Supply, lay, commissioning, jointing and testing of centrifugally cast (spun) ductile iron pipes of 150mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed at site of Following sizes:-. Note: The rate quoted by contractor are inclusive of all type of Joints.
Supply, lay, commissioning, jointing and testing of centrifugally cast (spun) ductile iron pipes of 100mm bore class K-9 with spigot and socket ends conforming to IS 8329/2000, IS: 12288 : 1987 code of practice for laying in trenches complete all as specified and directed at site of Following sizes:-. Note: The rate quoted by contractor are inclusive of all type of Joints.
S&F 250mm dia sluice valves cast iron both ends flanged/spigot and socket ends class PN-1.6 conforming to IS-14846 : 2000 with stainless steel spindle including joints & joining materials (Rubber gasket, nut, bolts, washers etc) complete all as specified and directed.
S&F 63mm bore gun metal globe / gate valve, screwed down high pressure with iron wheel had, screwed both ends for GI pipe including all fittings/fixture complete all as specified and directed.
Supply and Fix ductile iron air valve with two air relese outlets, conforming to IS 14845 of size 200 mm dia bore and fixing up in DI water supply mains complete all as specified and directed
M&L for construction of valve chamber of PCC 1:3:6 masonry built in CM (1:4) with MS covers 3 mm thick and 50x50x6 mm MS angle for locking arrangement including excavation and earth works PCC (1:4:8) type D2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1 plastering 15mm thick with CM 1:4 painting with one coat of bituminous black paint over a coat of red oxide primer on all steel surface, for the size of chamber 1200 mm x 1200 mm x 1200 mm complete all as specified and directed.
M&L for construction of valve chamber of PCC 1:3:6 masonry built in CM (1:4) with MS covers 3 mm thick and 50x50x6 mm MS angle for locking arrangement including excavation and earth works PCC (1:4:8) type D2 for foundation PCC bed/coping in cement concrete (1:2:4) type B1 plastering 15mm thick with CM 1:4 painting with one coat of bituminous black paint over a coat of red oxide primer on all steel surface, for the size of chamber 900 mm x 900 mm x 900 mm complete all as specified and directed.
M & L for Cutting of existing 250 mm dia CI/DI pipe line & insert of new 'T' of size 250 x 250 x 200 mm dia including complete earth work joint complete all as specified and directed. Note: The rate quoted by contractor are inclusive of Tee of size 250 x 250 x 200 mm
Supplying, installing, testing and commissioning of Bleaching dozing tank (HDPE chemical tank) of capacity 100 litres with cover and FHP dozing pump of capacity 0.22 litres per hour, single phase, 240 volts, 50 cycles, with necessary pipe connection from dozing pump to the water main with an injector fitting on the pumping main header including provision of all control accssories all as specified and as directed
Supply & fixing Foot Valve conforming to IS 4038, of size 100mm dia including complete earth work & joint complete all as specified and directed.
Supplying, installing, testing and commissioning of centrifugal pumpset with bronze impellor, electrical driven having discharge capacity 20 LPS upto 16 metres head, with AC 2800 rpm speed induction motor of suitable capacity to operate on AC, 3 phase, 415 volts, 50 Hz, with common base plate for electric motor and pump including provision of necessary star delta starter, cable connection from starter to motor with copper conductors complete, each pump set provided with independent suction arrangement consisting of suitable size of sluice valves with flanged ends, long body, class PN-1 at suction and delivery sides and gun metal stop cock controlled pressure gauge on the delivery side with provision of over load protection no volt release, single phase preventor and armoured PVC cable of suitable size from panel to electric motor complete all as specified and directed. Make : Kirloskar / KSB / Crompton / Jyoti Note : Foot valves and non return valves shall be measured and paid separately
EXTERNAL ELECTRIFICATION Supply, testing and commissioning of 11kV Outdoor type 500 KVA Package Sub-Station consisting of 11/0.433KV, Oil type transformer, HT panel, LT panel inside GI sheet steel enclosure with all interconnections, fully type tested as per the IEC-1330 and CPRI complete in all respect including foundation as manufacturers specification consisting of following items & as per detailed technical specifications:
Outer Enclosure:- Outdoor type enclosure having modular construction of 2mm Galvanised Sheet Steel.The Enclosure shall have IP54 degree of protection for HT & LT switchgear compartment & IP23 degree of protection for Transformer compartment. The enclosure exterior shall be painted with polyurethane paint (Seimen Gray Colour) . Each compartment will be provided with the door and pad locking arrangement The Compartment illumination lamp with door operated switch shall be provided for each compartment. Interconnection Between HT switchgear & Transformer using aluminium Bus bar & Interconnection between Transformer & LT switchgear using Bus bars. All metallic components shall be earthed to a common earthing point. Dimensions shall be manufactures instruction and as per the final decision at Site for components to be included in enclosure.
HT Panel: 11KV, 630A, indoor type 26.3 kA load break switch (LBS) with fuse trip, earth switch, dynamic mimic arrangement, 230 v ac shunt trip coil and 2NO+2NC aux. contacts for transformer protection incuding 11Kv HTHRC Fuses Rating: 50A Transformer: Supply, installing, testing and commissioning indoor type, step down transformer, 11 KV/433 Volts AC 3 phase 50 Hz, 500 KVA capacity, core type, double copper wound, oil immersed naturally cooled, Oil Natural- Air Natural, DYN-11 with Neutral brought out on secondary side (LV side) and having tapings at +5.0%, +2.5%, 0%, -2.5%, -5.0%, -7.5% & -10.0% on HV side to be changed by means of hand operated off load tap changer gear with all standard fittings & accessories (as per IS-1180:2014 EEL-2. LT Section:- 433V LT Indoor panel with Aluminium Busbars , Fabrication using 2 MM CRCA sheet steel , Ingress protection IP4X , solidilly earthed at substation complete with internal wiring, indication lamps etc consisting of following switchgear (i) Main Incoming ACB Microprocessor Manual Draw out type of rating 1000 Amps, Four Pole 50 KA , 50 Hz, 415 Volts, -1 No (ii) Outgoing MCCB FP 415 Volts 320 Amps 36 kA - 01 No (iii) Outgoing MCCB FP 415 Volt 250 Amps 35 KA - 02 Nos (iv) Outgoing MCCB FP 415 Volt 160 Amps 36 KA - 01 No (v) Outgoing MCCB FP 415 Volt 100 Amps 36 KA - 01 No
(vi) Outgoing MCCB FP 415 Volt 63 Amps 36 KA - 01 No (All MCCB are adjustable thermal & fixed magnetic) (vii) LED type RYB Phase indicator -01 Set (viii) Digital VAFPF meter - 01 no (ix) Heat resistance sleeve (x) TPN Aluminium bus bar with colour code 1500 Amps (xi) Copper wound with CTR 1000/5 - 01 Set (xii) Bus bar support Epoxy 50mm
All as per item No. 46 above but transformer of capacity 400 KVA and LT panel comprising of :- (i) Main Incoming ACB Microprocessor Manual Draw out type of rating 800 Amps, Four Pole 50 KA , 50 Hz, 415 Volts, -1 No?(ii) Outgoing MCCB FP 250 Amps 415 Volts 36 kA - 02 No (iii) Outgoing MCCB FP 200 Amps 415 Volts 36 kA - 03 No (All MCCB are adjustable thermal & fixed magnetic) (iv) LED type RYB Phase indicator -01 Set (v) Digital VAFPF meter - 01 no (vi) Heat resistance sleeve (vii) TPN Aluminium bus bar with colour code 1500 Amps (vii) Copper wound with CTR 800/5 - 01 Set (ix) Bus bar support Epoxy 50mm (x) Brass nut bolt washer 10 x 15mm (xi) Sheet metal work including fabrication, PCC foundation etc (xii) Complete wiring with copper cable, thimble etc Spare Compartment - 05 Nos to accommodate switch gear for Phase II Accn
Supply, installation, commissioning and testing of LT Panel, LT(415 Volts, 50 Hz, 3-phase, 4 wire supply) CPRI approved/tested, factory assembled, out door type, weather and vermin proof (Protection Class IP-54) made out of 3.15 mm (for external) and 2.00 mm (for internal) thick MS Sheet CRCA sheet with both side (front and back) hinged, double door opening for external, rubber lining, locking arrangement, painted internally and externally with powder coating of grey shade (RAL-7032) as per seven tank process complete mounted on angle iron 50mm x 50mm x 5 mm legs 45 cm high above GL and 15 cm embedded in ground with and including blocks of PCC 1:2:4 type C1 of block size 30x30x30 cm comprising of the following.
(a) Bus bar chamber having 4 nos air insulated Aluminium strip bus bars of rating not less than the 1.5 times the rated capacity of the incomer MCCB, bus bar must be colour coded heat shrinkable as well as outgoings shall have aluminium four pole (bus bar) of current carrying capacity not less than 1.5 times the rated capacity of individual MCCBs. (i) Incoming MCCB FP 320 Amps 415 Volts 36 kA - 01 No (ii) Outgoing MCCB FP 250 Amps 415 Volts 36 KA - 01 No (iii) Outgoing MCCB FP 100 Amps 415 Volt 25 ΚΑ - 01 Νο (v) Outgoing MCCB FP 32 Amps 415 Volt 10 KA - 02 Nos (vi) Outgoing MCCB FP 25 Amps 415 Volt 10 ΚΑ - 02 Nos (vii) Outgoing MCB SPN 40 Amps 230 Volt 10 KA - 02 Nos Note:- (All MCCB are adjustable thermal & fixed magnetic)
All as per sl item No 48.00 here in before but with consisting following switch gears and accessories (i) Incoming MCCB FP 415 Volts 250 Amps 36 kA - 01 No (ii) Outgoing MCCB FP 415 Volts 100 Amps 36 kA - 03 Nos
All as per sl item No 48.00 here in before but with consisting following switch gears and accessories (i) Incoming MCCB FP 415 Volts 160 Amps 36 kA - 01 No (ii) Outgoing MCCB FP 415 Volts 63 Amps 36 kA - 02 Nos (iii) Outgoing MCCB FP 415 Volt 32 Amps 25 KA - 02 Nos (iv) Outgoing MCB DP 240 Volt 32 Amps 10 KA - 02 Nos
All as per item No 48.00 here-in-before but with consisting following switch gears and accessories (i) Incoming MCCB FP 415 Volts 160 Amps 35 kA - 01 No (ii) Outgoing MCB SPN 230 Volts 20 Amps 25 kA - 06 Nos
All as per item No 48.00 here in before but with consisting following switch gears and accessories (i) Incoming MCCB FP 415 Volts 225 Amps 35 kA - 01 No (ii) Outgoing MCCB FP 415 Volts 160 Amps 25 kA - 01 Nos (iii) Outgoing MCCB FP 415 Volt 32 Amps 25 KA - 04 Nos (iv) Outgoing MCCB FP 240 Volt 63 Amps 10 KA - 01 No
Supplying, installation, testing and commissioning of 11 KV, 630 Amps having short circuit capacity 20kA/3-sec, outdoor (IP65 type), RMU (Ring Main Unit) 3-way comprising of 01 Nos manually operated Load Break Switches and 02 Nos 630 Amp Fixed-Type spring-charging VCBs, electrolytic grade copper bus bars all inside single, gas-filled, robotically welded stainless steel 304 (Non Ferrite Non Magnetic Grade) tank with minimum thickness 3+0.5 mm, IP 67 Degree of Protection, internal-arc classified 20kA/1sec as per IEC62271-200, on-site-repairable with site replaceable bushing/coupling/mechanism, gas refilling etc. The enclosure shall have pad lockable double-door access with anti-theft hinges, fully covering the front facia and cable boxes to ensure fail-safe anti-theft protection. The unit shall include the following along with all necessary accessories and fittings as required at site.
(A) 01 Nos Incoming Load Break Switches module each consisting of following accessories :- (i) Each switching-unit shall be designed as a three position switch. This three function switch combines the functions of switch-disconnector and earthing switch. (ii) 11kV, 630A Load Break Switch with interlocked line-earthing scheme both short circuit current - 20kA/3-sec, Making Capacity 50kA - 01 No (iii) Auxiliary contacts 1NO + 1NC - 01 No (iv) Spring-assisted snap-action manual mechanism with un-inhibited operating shaft for emergency manual operation with integrated earthing switch - 01 No (v) Cable terminals (site replaceable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV , 300 Sqmm , 3 Core , XLPE cable termination in live-condition : Each Set of 03 (vi) Right angle boots (push on type) : Each Set of 03 (vii) Arc proof cable covers having cable entry from bottom, front with Interlocking mechanism including earth switch - 01 No
(viii) Capacitive voltage indication fixed type system as per IEC61243 with LED - 01 Set (ix) Fault Passage Indicator - It shall be provided for each incomer load break unit, FPI with LED/digital display to be added for detection of cable fault - 01 No (x) ON, OFF, EARTH mechanical indication on the front mimic of the panel - 01 No (B) 02 Nos. Outgoing VCB module each consisting of following accessories :- (i) Each function-unit consists of a vacuum-circuit breaker in combination with a three position-switch. The three-position-switch fulfills the operation of the disconnector-function and earthing function. (ii) 11kV, 630A Fixed-Type VCB module with series disconnector cum earthing switch of short circuit breaking current/withstand - 20kA/3-sec, Making Capacity - 50kAp - 01 No (iii) Aux. contacts 1NO+1NC - 01 No (iv) Stored-energy manual high-endurance spring charging mechanism (M1+), with inbuilt spring-charging lever and mechanically latched ON/OFF push-buttons to allow un-inhibited operation -01 No (v) Cable terminals (site replaceable Cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes) with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access upto 11 KV, 185 Sqmm, 3 Core, XLPE cable termination in live-condition - Set of 3
(vi) Right angle boots (push on type) - Set of 3 (vii) Associated ring-core cast-resin insulated CTs 50/1 Amp 2.5 VA, 5P10 for protection – Each Set of 3 (vii) O/C + 1E/F self powered numerical protection relay with Low and High set for over current and Earth Fault. Relay shall have the facility to display the maximum loaded phase current also. Relay shall record minimum 5 fault records with time stamping and shall be communicable on MODBUS. (viii) Arc proof cable covers with self Interlocking mechanism with earth switch -01 No (ix) Capacitive voltage indication fixed type system as per IEC61243 with LED -01 No (x) Mechanically latched buttons for breaker On/Off - 01Set (xi) ON, OFF, TRIP mechanical indication on the front mimic of the panel.(C) Additional equipment delivered separately or mounted separately :- (i) Operating Handle for Manual Isolator/Disconnector/Earthing Operation - 02 Nos (ii) Standard Manometer - 01 No (iii) Operation and Maintenance Manual - 01 No (iv) Installation & Commissioning Manual - 01 No (v) Cable clamping provision (standard) - 01No
Note :-(i) It shall be preferable to have all feeder-switches inside single stainless steel compartment with incomer feeders at the extremities to prevent chances of failure due to plug-in coupling arrangement. (ii) Necessary interlocking arrangement shall be provided for safety and operations (iii) Above switchgear shall confirm to relevant IEC (62271-200) for design, manufacturing and internal arc compliance. Any claims towards internal arc compliance, number of mechanical/electrical/short-circuit operations, gas-leakage rates etc. shall not be accepted unless proven via type-test reports of model being offered. (iv) Cost of Provision of Plinth for RMU as per OEM drawing shall be deemed to be included in the cost inserted by the bidders.
S & F cable route indicator of size 100 mm x 100 mm x 5 mm thick GI Plate with insertion there on bolted welded to 35 mm x 35 mm x 6 mm angle iron 60 cm long and foundation in ground with PCC as required for LT/HT cable incl necessery earth work all as specified and directed.
Supply and fix lithium based energy efficiet integrated solar street light 30 watt in single FRP body encase solar PV panel 53/55 Wp monocrystalline, lithium battery 11.1/12.8V, 28.6AH with inbuilt BMS, high brightness W-LED (180lm/Watt) lamp, CRI>70, color temperature 6500K, microcontroller based charge controller cum driver, automatic dimming function with PRI motion sensor, dusk to down operation,LuX output 20-25 (from 8-9 mtr height), working temperature (-) 10 to (+) 55°c weight : 14-16 Kg, with adjustable. MS clamp suitable for pole/wall mounting. protection : short circuit, overload, reverse polarity and battery protections. Firm should produce vital parameters test report from NABL accredited lab and should be of made in India with CE & ROHS certified and including necessary civil work and incl GI pipe bracket of suitable dia light grade.
Boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine for laying under ground pipe upto 100mm dia complete all as specified and directed. Note :- GI pipe shall be measured and paid separately.
LIGHTINING PROTECTION M&L for GI pipe of 40mm dia 1 mtr height grouting in PCC type C2 1:3:6 40 mm grade aggregate for fixing of air termination including with socket reducer 40 x 25mm and aluminium gutakha externally threated suitable for socket reducer 25mm and internally threated for air termination rod complete all as specified and directed
SUMMER APPLIANCES Supply and fixing refrigerator, electric driven (single phase), frost-free, double door, auto defrost to stop Ice build up, automatic adjustment of speed in response to cooling demand, capacity upto 195 litres (nearest available). BEE 5 star rated complete with all accessories such as mounted trolley, complete all as specified and directed.
Supply and fixing refrigerator, electric driven (single phase), frost-free, double door, auto defrost to stop Ice build up, automatic adjustment of speed in response to cooling demand, capacity upto 310 litres (nearest available). BEE 5 star rated complete with all accessories such as mounted trolley, complete all as specified and directed.
Supply and fixing Desert Cooler electric driven (Single phase), having nominal air flow capacity 4000 Cum per hour or nearest size, 70 litter of water tank capacity steel body complete all as specified and directed
Supply and Fixing voltage stabilizer for automatic operation single phase naturally air cooled copper bounded, indoor type & designed for input variation between 170 volt to 260 volt with output voltage stabilizer at 230 volt with accuracy of (±) 2.5% and of capacity 3.0 KVA complete all as specified and directed.
Supply and Fixing voltage stabilizer for automatic operation single phase naturally air cooled copper bounded, indoor type & designed for input variation between 170 volt to 260 volt with output voltage stabilizer at 230 volt with accuracy of (±) 2.5% and of capacity 4.0 KVA complete all as specified and directed.
Supply and Fixing voltage stabilizer for automatic operation single phase naturally air cooled copper bounded, indoor type & designed for input variation between 170 volt to 260 volt with output voltage stabilizer at 230 volt with accuracy of (±) 2.5% and of capacity 1.0 KVA complete all as specified and directed.
DG SET Supply , install , test and commissioning diesel engine driven silent generating set, 415 volts, 20 kVA 3 phase, 0.8 power factor, 50hz, brushless,1500rpm, self excited, self regulated, AC, and conforming to condition under IS 4722, BS-5514,2613/5000 and adhering to CPCB II norms with control panel complete all as specified and as directed with and including following:
(A) ALTERNATOR Standard design alternator rated at 20KVA net output at site after considering all derating factor, site condition and all power factor 0.8, AC 3 phase, 4 wire 415 volts, 50 cycles,1500 rpm, self excited, self regulated, screen protected, drip proof IP-23 enclosure, brishless design woth hub and sealed ball/roller bearing,wiith winding on each pole face, insulating class H, band of voltage regulation (+- )1% operated voltage from no load to full load and self conforming to BS-2613/BS-5000 and shell B in position to generate supply with frequency regulation with in (+-3) % tolerance, revoling field type, Make: M/S Stamford, M/S Kirloskar electrric, M/S Caterpillar (B) DIESAL ENGINE Adequate capacity diesel engine suitable to above alternator , water cooled, to drive independently above alternator and after considering deratingas per site condition directly coupled to alternator throught flexible coupling of multicylinder, multistroke, direct injecting, cold starting, 1500 rpm , as per relevant ISI/BS-5514 with an overload cap of 10% for 1 hour in any 12 hours continuous running complete with standard accessories all as specified and required for safe running and operation, salient feature of accessories shall be as under: (i) Flywheel housing (ii) Air cleaner wet/dry type (iii) Fuel Filter (iv) Fuel Injection system including injection pump, solenoid switch, nozzle as per manufacturer's specifications (v) Lubricating oil filter, bypass filter, oil cooler (vi) Lubricating oil pump (vii) Turbocharger (viii) Radiator for water cooling
(ix) 12 volts starting system consisting of batteries of capacity as recommended by manufacturer, battery connections with copper leads and with lugs of adequates size, initial charging of batteries, battery charger/generator, starter motor, starter gear, start and stop push buttons, ignition key and switch. (x) Residential type exhaust silencer complete with exchust pipe of suitable dia upto outside the accoustic renclosure, all covered with glass wool wrapped with aluminium foil of 28 SWG adequate to create draft for safe exchaust without transferring vibrations to buildings/walls, flexible exhaust pipe complete. (xi) Microprocessor control electronic metering and module (ECPG) for indication of battery voltage, oil pressure , water pump, engine rmp, hours meter and protection against low oil pressure, high water temperature and over speed of engine including electronic govering . (xii) Battery charging indicator (xiii) Radiator cooling system comprising of radiator, radiator fan belt, water pump with belts , thermostat. (xiv) Fuel hoses (xv) Separate fuel tank made out of 3mm thick CRCP sheet of suitable capacity not less than 500 liters with level indicator, stop cock, drain plug/valve, breath inlet and outlet connections and all fuel supply lines as required at site and as per manufacturers instructions including return and overflow as well as fuel filling arrangement with piping (xvi) Air intake system
M/s Madan Lal Bansal and Co. Contractors Pvt. Ltd. (BID ID -3190059)
VERMA BROTHERS (BID ID -3191124)
SOOD ASSOCIATES PVT LTD (BID ID -3191448)
M M SHAWL Engineers and contractors pvt ltd (BID ID -3190211)
M/s Khanna Enterprises (BID ID -3188849)
Aalaya Engineering Project Private Limited (BID ID -3188323)
Ktech Engineer Builders Co. Pvt. Ltd (BID ID -3191394)
stage.html
html • 0.08 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid