| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.9 LAccepted-AOC 334 SCHOOLDANGA BANKURA BANKURA PIN 722101 WEST BENGAL | BANKURA | BANKURA | WEST BENGAL | 722101 | L1 | Accepted-AOC 1st lowest | |
| 2 | L2₹20.9 L+₹133 (<0.01%)Rejected-Finance JAMBEDIA POST JAMBEDIA DIST BANKURA PIN 722 139 | JAMBEDIA | BANKURA | WEST BENGAL | 722139 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹20.9 L+₹184 (<0.01%)Rejected-Finance 334 1 SCHOOLDANGA BANKURA 722101 | BANKURA | WEST BENGAL | 722101 | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹41,851
Closing Date
25 Jun 2024, 10:55 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
Bankura Electrical Division , P.W.Dte.
Various work in the nature of regular Operation , Repair and Maintenance on the basis of vetted estimate from PWD (Civil) , PWD (Electrical ) , and PHE (Civil) at Bankura Sammilani Medical College and Hospital in Bankura District for the Super Specia
2024_WBPWD_692138_1
WBPWDTE/EE/BED/NIQ_90/Q of 2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Wise
45 days
BSMC
Please refer Tender documents.
3 documents required · 3 mandatory
₹41,851
22 Aug 2024
11 Jun 2024
27 Jun 2024
11 Jun 2024
25 Jun 2024
11 Jun 2024
Amount
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable photo smoke sensor with Base Two-wire SLC loop connection, Unit uses base for wiring.Compatible with FlashScan® and CLIP protocol systems,Stable communication technique with noise immunity,Designed to meet UL 268 7th Edition,Factory preset at 1.5% nominal sensitivity for panel alarm threshold level, LED “blinks” when the unit is polled (communicating with the firepanel) and latches in alarm. Low standby current.( Make-Notifier/Honeywell/ Johnson Controls / Edward/ Secutron/ Securiton/ Apollo)
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Loop Control Module. Adds SLCs to NFS-3030/ NFS2-3030; NFS-3030/NFS2-3030 supports up to five LCM- 320s and five LEM-320s.
Supply, Installation,Testing & Commisioning of Micropresssor controlled Addressable Loop Expander Module. Expands each LEM used on the NFS-3030/NFS2-3030; expands NFS-640/NFS2-640 to two loops.(Make-Notifier)
Supply, Installation,Testing & Commisioning of CPU 3030D Certified for seismic applications when used with the appropriate seismic mounting kit. • Approved for Marine applications when a marine-listed version is used with marine-listed compatible equipment. See DN-60688. • Complies with UL 2572 Mass Notification Systems (NFS2-3030 version 20 or higher). • One to ten isolated intelligent Signaling Line Circuits (SLC) Class A, B, or X. • Wireless fire protection using SWIFT Smart Wireless Integrated Fire Technology. See DN-60820. • Up to 159 detectors and 159 modules per SLC; 318 devices per loop/3,180 per FACP or network node. – Detectors can be any mix of photo, thermal, or multi-sensor; wireless detectors are available for use with the FWSG(A). – Modules include addressable pull stations, normally open contact devices, two-wire smoke detectors, notification, or relay; wireless modules are available for use with the FWSG(A). • Large 16 line, 640 character LCD backlit display or use displayless as a network node. • Network options: – High-speed network for up to 200 nodes (N16e/x, NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCD, NCA-2, DVC-EM, ONYXWorks, NFS-3030, NFS-640, and NCA). – Standard network for up to 103 nodes (N16e/x, NFS2-3030, NFS2-640, NFS-320(C), NFS-320SYS, NCD, NCA-2, DVC-EM, ONYXWorks, NCS, NFS-3030, NFS-640, NCA, AFP-200, AFP300/400, AFP-1010, and AM2020). Up to 54 nodes when DVCEM is used in network paging. • Built-in Alarm, Trouble, Security, and Supervisory relays. • VeriFire® Tools online/offline program option.(Make-Notifier)
Supply, Installation,Testing & Commisioning of Power Supply unit NOTIFIER’s AMPS-24/E is an addressable power supply and battery charger with up to three 24 VDC outputs. It operates in either FlashScan® or CLIP (Classic Loop Interface Protocol) mode with the NFS-3030/NFS2-3030 Fire Alarm Control Panel (FACP). It can also be used as the primary power supply for the NCA-2 Network Control Annunciator. battery charger with up to three 24 VDC outputs. It operates in either FlashScan® or CLIP (Classic Loop Interface Protocol) mode with the NFS-3030/NFS2-3030 Fire Alarm Control Panel (FACP). It can also be used as the primary power supply for the NCA-2 Network Control Annunciator.(Make-Notifier)
Supply, Installation,Testing & Commisioning of Repeter Panel The LCD-160 is a 640-character Liquid Crystal Display (LCD) annunciator and remote control for the NOTIFIER NFS-3030/ NFS2-3030 Fire Alarm Control Panel (FACP). The LCD-160 will mimic the top portion (160 characters) of the NFS-3030/ NFS2-3030’s 640-character display. This provides the event and preprogrammed custom messages as displayed on the main panel. The full screen contains soft key functions, and can display other panel information.(Make-Notifier)
Commissioning of communication of LCD-160 Repeater Panel.
UJJWAL MUKHERJEE
TAPAN KUMAR SARKAR
technical_1507344.pdf
PDF • 0.56 MB
techsummary_1507344.pdf
PDF • 0.64 MB
finance_1507344.pdf
PDF • 0.74 MB
BOQ Comparative Chart
xlsx • 0.01 MB
finsummary_1507344.pdf
PDF • 0.75 MB
90Q.pdf
PDF • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .