| Sl No | Description | Qty | Unit | Raina Builders and Suppliers L3 | NEW ALLIED TRADERS L2 | M/S SIGMA CONSTRUCTION L5 | MOHD USMAN SAYEED L8 | M/S TRANS TECH ENGINEERS L6 | M/s MAHASHAKTI ELECTRICAL WORKS L1 | M/S K.K ELECTRICALS L7 | M/S PARAS ELECTRICAL L4 |
|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00Supply, Erection, Testing & Commissioning for Augmentation from 100KVA to 250KVA Sub Station at Forest Protection Force office HQ Complex Narwal, Jammu. | |||||||||||
| 1.01 | 250KVA, 11/0.433-0.250KV;50Hz, Copper Wound Distribution of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 Mtrs, suitable cable of ratings. | 1 | No. | 5,27,000 ₹5,27,000 | 5,10,000 ₹5,10,000 | 5,75,000 ₹5,75,000 | 6,85,000 ₹6,85,000 | 5,10,113 ₹5,10,113 | 4,95,900 ₹4,95,900 Lowest | 6,10,000 ₹6,10,000 | 5,15,000 ₹5,15,000 |
| 1.02 | 2x185mmsq single phase cable,1.1kv Grade, PVC insulated standard conductor FRLS type | 44 | Mtr. | 550 ₹24,200 | 425 ₹18,700 | 400 ₹17,600 | 1,400 ₹61,600 | 450 ₹19,800 | 295 ₹12,980 Lowest | 790 ₹34,760 | 700 ₹30,800 |
| 1.03 | Transformer Bed | 60 | kg | 130 ₹7,800 | 125 ₹7,500 | 100 ₹6,000 Lowest | 145 ₹8,700 | 165 ₹9,900 | 120 ₹7,200 | 125 ₹7,500 | 115 ₹6,900 |
| 1.04 | LT Distribution Box for 250KVA DTR with MCCB FOR INCOMER & SWITCH Fuse units for outgoing circuits. | 1 | No. | 38,000 ₹38,000 | 35,000 ₹35,000 Lowest | 35,000 ₹35,000 Lowest | 45,000 ₹45,000 | 45,000 ₹45,000 | 39,000 ₹39,000 | 40,000 ₹40,000 | 43,000 ₹43,000 |
| 1.05 | Earthing of Substation complete | 3 | No. | 1,600 ₹4,800 | 2,000 ₹6,000 | 1,500 ₹4,500 Lowest | 4,500 ₹13,500 | 8,000 ₹24,000 | 1,500 ₹4,500 Lowest | 2,200 ₹6,600 | 2,000 ₹6,000 |
| 1.06 | 11 KV GO Set | 1 | Set | 4,500 ₹4,500 Lowest | 8,300 ₹8,300 | 7,500 ₹7,500 | 9,500 ₹9,500 | 12,000 ₹12,000 | 9,000 ₹9,000 | 10,000 ₹10,000 | 8,500 ₹8,500 |
| 1.07 | 11 KV HG Set | 1 | Set | 6,500 ₹6,500 | 4,000 ₹4,000 | 3,000 ₹3,000 Lowest | 5,300 ₹5,300 | 6,000 ₹6,000 | 3,500 ₹3,500 | 4,500 ₹4,500 | 4,500 ₹4,500 |
| 1.08 | ST Poles 9 Mtr. Long | 2 | No. | 16,500 ₹33,000 | 16,000 ₹32,000 | 15,000 ₹30,000 Lowest | 25,000 ₹50,000 | 15,500 ₹31,000 | 15,500 ₹31,000 | 18,000 ₹36,000 | 17,500 ₹35,000 |
| 1.09 | 11 KV LA (Stn. type) | 1 | Set | 5,000 ₹5,000 | 3,750 ₹3,750 | 2,500 ₹2,500 Lowest | 5,200 ₹5,200 | 8,000 ₹8,000 | 4,000 ₹4,000 | 4,500 ₹4,500 | 3,500 ₹3,500 |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
24 Aug 2026, 2:00 pmClosed
Executive Engineer JPDCL ED-I Parade Jammu
Office of Executive Engineer JPDCL ED-I Parade Jammu
Supply, Erection, Testing, Commissioning for Providing of electricity Supply by way of Installing 250KVA Transformer (Augmentation from 100KVA to 250KVA Sub Station) alongwith HT network at Forest Protection Force office HQ Complex Narwal, Jammu
2026_PDD_319371_1
ED-I/e-NIT/27 of 2026-27 dated 04.08.2026
Open Tender
Electrical and Maintenance Works
Turn-key
60 days
Parade Jammu
Please refer tender documents
11 documents required · 11 mandatory
₹500
Executive Engineer JPDCL ED-I Parade Jammu
₹24,000
5 Sept 2026
4 Aug 2026
25 Aug 2026
4 Aug 2026
24 Aug 2026
4 Aug 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1Supply, Erection, Testing & Commissioning for Augmentation from 100KVA to 250KVA Sub Station at Forest Protection Force office HQ Complex Narwal, Jammu. | |||||
| 1.01 | 250KVA, 11/0.433-0.250KV;50Hz, Copper Wound Distribution of latest Energy Efficiency Level-2 (New), IS1180 Part-I; 2014 as per latest upto date amendment with externally fitted MCCB with cable box and 4x4 Mtrs, suitable cable of ratings. | 1 | No. | - | - |
| 1.02 | 2x185mmsq single phase cable,1.1kv Grade, PVC insulated standard conductor FRLS type | 44 | Mtr. | - | - |
| 1.03 | Transformer Bed | 60 | kg | - | - |
| 1.04 | LT Distribution Box for 250KVA DTR with MCCB FOR INCOMER & SWITCH Fuse units for outgoing circuits. | 1 | No. | - | - |
| 1.05 | Earthing of Substation complete | 3 | No. | - | - |
| 1.06 | 11 KV GO Set | 1 | Set | - | - |
| 1.07 | 11 KV HG Set | 1 | Set | - | - |
| 1.08 | ST Poles 9 Mtr. Long | 2 | No. | - | - |
| 1.09 | 11 KV LA (Stn. type) | 1 | Set | - | - |
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.56 MB
sbd27.pdf
Tender Documents • 1.19 MB
BOQ_1057603.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .