Rectification of APFC Panel with other allied works at Ghagra (IBS-II) under Khatra, Hirbandh, Ranibandh Block surface water based piped water supply scheme under under Bankura Mechanical Division PHE Dte
2026_PHED_5080190_8
WBPHED//BMD/NIeT- 06 OF 2026-2027
Open Tender
MECHANICAL
Item Rate
30 days
Bankura
Please refer Tender documents.
5 documents required · 5 mandatory
₹13,000
Yes
15 Oct 2026
15 Oct 2026
6 Nov 2026
15 Oct 2026
4 Nov 2026
15 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Detection of fault, dismantling and removal of burnt-out electrical spares, wires and other damaged components from the Motor Control Panel, including thorough cleaning of the panel and removal of all burnt/damaged materials from inside the panel after proper disconnection and isolation of electrical lines, complete with engagement of skilled electrician and all necessary labour, tools and tackles, as directed by the Engineer-in-Charge (EIC). | 1 | L.S. | - | - |
| 2 | Supply and delivery at site of the following accessories as per approved sample, complete with all necessary fittings and accessories, conforming to the required specifications and as approved by the Engineer-in-Charge. Make: ABB/Siemens/Approved make as per PHED Vendor List. | - | - | - | - |
| 3 | L.T. MCC CUM PDB PANEL | - | - | - | - |
| 4 | Microprocessor based Protection relay, EOCR-3DM2, 0-80 Amp.
Rated supply voltage 100...240 V AC/DC
Protection type-Overload, In > OC setting
Contacts type and composition 1 NC + 1 NO (OL) 1 NO (AL/UL/TO)
Underload, In < UC setting
Locked rotor for starting, In > 2...8 times OC setting
Locked rotor for running, In > 1.5...5 times OC setting
Sensitivity to phase loss
Phase unbalance, 10...50 %
Sensitivity to phase reverse | 1 | Each. | 3 | ₹3 |
| 5 | 50KVAR APFC PANEL | - | - | - | - |
| 6 | DIGITAL VAF METER | 2 | Each. | 5 | ₹10 |
| 7 | RED, GREEN, AMBER, YELLOW LED LAMPS, 230 V AC | 10 | Each. | 6 | ₹60 |
| 8 | BLUE, LED LAMPS, 230V AC | 2 | Each. | 7 | ₹14 |
| 9 | 15KVAR HEAVY DUTY CAPACITOR BANK, 440V AC | 6 | Each. | 8 | ₹48 |
| 10 | 5KVAR HEAVY DUTY CAPACITOR BANK, 440V AC | 2 | Each. | 9 | ₹18 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.11 MB
Tendernotice_2.pdf
PDF • 5.58 MB
BOQ_5188154.xls
BOQ • 0.35 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .