Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹19.2 LAccepted-AOC E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | 1 | Accepted-AOC LOWEST RATE | |
| 2 | 2₹19.6 L+₹36,970 (1.93%)Rejected-Finance 3788 SHAH GANJ GB ROAD NEW DELHI 110006 | NEW DELHI | DELHI | DELHI | 110006 | 2 | Rejected-Finance NOT LOWEST | |
| 3 | 3₹19.8 L+₹62,110 (3.24%)Rejected-Finance C 125 A KUNWAR SINGH NAGAR NANGLOI NEW DELHI 110041 | NEW DELHI | WEST DELHI | DELHI | 110041 | 3 | Rejected-Finance NOT LOWEST | |
| 4 | 4₹19.9 L+₹75,195 (3.92%)Rejected-Finance | 4 | Rejected-Finance NOT LOWEST | |
| 5 | 5₹21.9 L+₹2.7 L (14.1%)Rejected-Finance | 5 | Rejected-Finance NOT LOWEST |
Tender Value
₹24.9 L
EMD Value
₹49,880
Closing Date
18 Jan 2023, 6:00 pmClosed
GE (AF) PALAM DELHI CANTT
GE (AF) PALAM DELHI CANTT-10
REPAIR/MAINT OF PIPELINES, PUMP SET AND RECHARGING OF BORE WELLS, PUMP ETC AT VARIOUS LOCATIONS IN CAMP AREA, TECHNICAL AREA , CPRU, MAUDE LINE AND AUTOMATION OF WATER SUPPLY SYSTEM UNDER GE (AF) PALAM DELHI CANTT-10
2022_MES_570484_1
GENP-66/2022-23
Open Tender
Civil Works
Item Rate
180 days
GE (AF) PALAM DELHI CANTT
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE (AF) PALAM
₹49,880
Yes
20 Apr 2023
21 Dec 2022
19 Jan 2023
21 Dec 2022
18 Jan 2023
5 Jan 2023
Amount
Disconnectiong existing defective electric motor of any make, 4 to 5 HP from electric mains isolating the naked connections, removing from foundation by unscrewing the nuts, bolts etc, discouple from pump, opening of motor for inspection in presence of Engr-in-Charge & carry out minor repairs at site, re-assembling the motor after repair, refixing in position, re-connecting same as prior including replacement of nuts, bolts washers of suitable size, testing and commissioning as and when required complete all as specified and directed. Note : (a) Replacement of defective parts shall be measured and paid separately as S&F here-in-after. (b) In case of major repairs not possible at site, the motor shall be shifted to contractor’s wksp and cost of shifting to wksp and back to site deemed to be included in the quoted rates.
All as per item No.1 here-in-before but capacity 40 HP to 50 HP
All as per item No.1 here-in-before but capacity 15 HP to 25 HP
All as per item No.1 here-in-before but capacity upto 3 HP (Single Phase) of any type & size.
Taking out old unserviceable/burnt copper winding of motors capacity 4 to 5 HP (defective motor taken out from item No. 1above) and material and labour for rewinding of elect motor of capacity up to 5 HP, 3 phase with super enameled copper winding wire of suitable gauge as per existing including cleaning of rotor slots, all winding/insulation material, varnishing etc. complete and testing at site on full load after reinstallation to the full satisfaction of Engr-in-Charge.
All as per item No 5 here-in-before but upto 3 HP single phase of any type & size. (defective motor taken out from item No. 4 above)
All as per item No 5 here-in-before but 40 HP to 50 HP, 3 phase of any type & size. (defective motor taken out from item No. 2 above)
All as per item No 5 here-in-before but 15 HP to 25 HP, 3 phase of any type & size. (defective motor taken out from item No. 3 above)
Taking out unserviceable terminal plate with connector and outer cover of electric motor of any make, type upto 5 HP capacity and S&F, testing of terminal plate with connector same as per existing complete. (defective motor taken out from item No. 1 & 4 above)
All as per item No 9 here-in-before but 40 HP to 50 HP, 3 phase of any type & size. (defective motor taken out from item No. 2 above)
All as per item No 9 here-in-before but 15 HP to 25 HP, 3 phase of any type & size. (defective motor taken out from item No. 3 above)
Material & Labour for replacement of Ball bearing of the electric motor 40 to 50 HP, 415 Volt complete all as directed.
Material & Labour for replacement of Ball bearing of the electric motor 15 HP to 25 HP, 415 Volt complete all as directed.
Material & Labour for replacement of Ball bearing of the electric motor upto 5HP, three/single phase complete all as directed.
Material & Labour for replacement of MS Shaft of the electric motor upto 5 HP 440 Volts, complete all as specified.
All as per item No 15 here-in-before but for 15 to 25HP, 440 Volts Electric Motors.
Taking out defective monoblock/centrifugal pump set of single/three phase upto 5 HP, any type, make by unscrewing the foundation bolts, disconnecting from water connection, and disconnecting from electric motor, opening for inspection in presence of Engr-in-Charge as and when required and carry out minor repair at site, in case of major repair/replacement of parts not possible at site, the pump shall be shifted to contractor's workshop on his own cost, and re-fixing, re-connecting in position, testing and commissioning complete including replacement, all as specified and directed by Engr-in-Charge. Note:- 1. Replacement of defective part by new one shall be measured and paid separately under respective items. 2. Cast of shifting to WKSP and back to site deemed to be included in the quoted rates.
All as per item 17 here-in-before but 40 to 50 HP.
All as per item 17 here-in-before but 15 to 25 HP.
Material & Labour for unserviceable/defective mild steel shaft 40 to 50 HP centrifugal pump set of any make complete all as specified and as directed. (Note:- Defective pump set taken out from item No 18 here-in-before).
All as per item No 20 here-in-before but for Gland packing, CI Check Nut, Gland Cover with Nuts and Bolts complete all as specified.
All as per items 20 here-in-before but ball bearing including greasing etc complete all as specified.
All as per items 20 here-in-before but impeller bronze.
All as per items 20 here-in-before but neck ring.
Material & Labour for replacement of unserviceable/defective mild steel shaft 15 to 25 HP, centrifugal pump set of any make complete all as specified and as directed. (Note:- Defective pump set taken out from item No 19 here-in-before).
All as per item No 25 here-in-before but for Gland packing, CI Check Nut, Gland Cover with Nut and Bolts, complete all as specified.
All as per items 25 here-in-before but ball bearing including greasing etc complete all as specified.
All as per items 25 here-in-before but impeller bronze.
All as per items 25 here-in-before but neck ring.
Material & Labour for replacement of unserviceable/defective mild steel shaft upto 5 HP centrifugal pump set of any make complete all as specified and as directed. (Note:- Defective pump set taken out from item No 17 here-in-before).
All as per item No 30 here-in-before but Gland packing, CI Check Nut, Gland Cover with nut and bolts complete.
All as per items 30 here-in- before but ball bearing including greasing etc complete.
All as per items 30 here-in-before but impeller bronze/brass.
All as per items 30 here-in-before but neck ring.
Disconnecting electric connections from starter, disconnecting the pump and motor opening the pump and motor to locate the faults in presence of Engineer-in-Charge as and when required, and carry out necessary repairs as directed including transporting to workshop, re-assembling the same after repair, taking down in well, including column pipe of any dia, each 10 ft long, and submersible cable, which have been taken out, re-connecting all electrical and water connections as per existing complete testing and commissioning including new packing materials, nuts,bolts washers of suitable size all as specified and as directed. Note:- 1. The replacement of parts shall be measured and paid separately under respective items. 2. Cost of shifting to workshop and back to site included in the quoted rates.
Taking out old unserviceable/burnt winding from the submersible 3 phase motors up to 3 HP and M& L for rewindinig the same with insulated winding wire as per existing gauge as approved by Engr-in- Charge and testing after repair all as specified and as directed.
All as per items 36 here-in-before but above 3HP and upto 5 HP.
All as per items 36 here-in-before but above 5 HP upto 7.5 HP.
All as per item No 36 here-in-before above 7.5 HP and up to10 HP.
Supply and fixing in replacement of GM bearing bush for submersible pump and motor upto 10 HP complete.
All as per item No 40 here-in-before but for rotor sleeve.
All as per item No 40 here-in-before but for water seal.
All as per item No 40 here-in-before but for thrust bearing.
All as per item No 40 here-in-before but for revolving disc.
All as per item No 40 here-in-before but for connection piece.
All as per item No 40 here-in-before but for sand guard.
All as per item No 40 here-in-before but for sealing ring.
All as per item No 40 here-in-before but for upper housing.
All as per item No 40 here-in-before but for lower housing.
All as per item No 40 here-in-before but for upper flange with studs & nuts.
All as per item No 40 here-in-before but for lower flange with studs & nuts.
All as per item No 40 here-in-before but for seal bush.
All as per item No 40 here-in-before but for motor base.
All as per item No 40 here-in-before but for cable seal.
All as per item No 40 here-in-before but for thrust plate.
All as per item No 40 here-in-before but for S. S. coupling.
All as per item No 40 here-in-before but for key for coupling.
All as per item No 40 here-in-before but for stud & nuts for connection piece.
All as per item No 40 here-in-before but for suction chamber.
All as per item No 40 here-in-before but for CI bowl stage.
All as per item No 40 here-in-before but for PVC. Impeller.
All as per item No 40 here-in-before but for E. P. Impeller.
All as per item No 40 here-in-before but for stage bowl E. P.
All as per item No 40 here-in-before but for guide bush.
All as per item No 40 here-in-before but for DOL bush.
All as per item No 40 here-in-before but for DOL sleave.
All as per item No 40 here-in-before but for inter ring.
All as per item No 40 here-in-before but for DOL piece.
All as per item No 40 here-in-before but for NRV CI body.
All as per item No 40 here-in-before but for Impeller key.
All as per item No 40 here-in-before but for pump shaft seven stage.
All as per item No 40 here-in-before but for pump jacket seven stage.
All as per item No 40 here-in-before but for distance sleeve.
All as per item No 40 here-in-before but for pump shaft key/stage.
All as per item No 40 here-in-before but for but hook.
All as per item No 40 here-in-before but for GM neck ring.
Supply and fixing for surface mounting Time switch maxier QT 30A (24 Hrs) complete including dismanting the existing time switch from the existing panel. Make : Legrand or equivalent in L&T/ Havells.
Supply and fixing for power contactors MNX-40 Amps, 415 Volts, AC operated 3 phase, MNX or as per existing complete including taking down the existing all as specified and directed. Make - L & T/Legrand/ Havells.
Supply and fixing for power contactors MNX-25 Amps, 415 Volts, AC operated 3 phase, coil voltage 220 or as per existing complete including taking down the existing all as specified and directed. Make - L & T/Legrand/Havells.
Supply and fixing power contactors 32 Amps, 415 Volts, AC operated 3 phase, coil voltage 220 MNX or as per existing complete including taking down the existing all as specified and directed. Make - L & T/Legrand/Havells.
All as per item No 80 here-in-before but 70 Amps.
All as per item No 80 here-in-before but 16 to 32 Amps.
All as per item No 80 here-in-before but 140 Amps MNX type contractor complete.
Supply, connecting, testing and commissioning submersible cable with copper conductor, stranded of size 10 Sqmm 3 core complete including dismantling the old unserviceable cable.
S&F for fully automatic star delta starer in repairs, 3 Phase 415 volts suitable for 40 HP to 50 HP pumps complete including dismantling the existing starter. Make : Siemens/L&T/Havells.
All as per item No.85 here-in-before but DOL Starter in sheet metal enclosure type, relay range 9-15 Amp, suitable upto 10 HP motors including dismantling the existing starter. Make : Siemens/L&T/Havells.
Disconnecting, electrically, isolating the existing unserviceable MCCB TP/TPN of any make and capacity and Supply, fixing, connecting, testing and commissioning MCCB 400 Amp triple pole, breaking capacity 50KA conforminig to relevant IS, 440 volts fixed in existing panel including necessary modification for new MCCB including all joining and connecting material all as specified.
All as per item No. 87 here-in-before but 200 Amps, breaking capacity 36 KA.
All as per item No. 87 here-in-before but 100 Amps breaking capacity 25 KA
Supplying and laying in repair synthetic Rubber insulated mats 2 mm thick for voltage upto 3.3 kv for electrical purpose as per IS 15652-2006 (superseding IS 5424) suitable for electrical shock safety of size 2m x 1m ISI marked and laid in front of the LT panel all as specified and directed by Engr-in-Charge.
Material & Labour for painting to exposed CI/GI water pipe lines of header/suction/delivery of bore wells/ booster pumps any type/make/size including sluice valves, fittings and non return valves at water supply installations as per specified colour code after cleaning and scraping out old paint including writing/marking complete all as specified and directed.
Supply and fixing of single phase preventor with five protection, VSP-2 complete all as specified and directed by Engr-in-Charge. Make: Minilac/ L&T/Legrand.
Supply and fixing in replacement of MCB, TP, 32 to 63 Amps as per site requirement complete all as specified and directed
Supply and fixing BI metalic over load relay, range 28-40 Amp rating for automatic starters complete all as specified and as directed. Make : Legrand / L& T/ Havells/ Schinider.
All as per item No 96 here-in-before but 9-15 Amp.
All as per item No 96 here-in-before but 20-33 Amp.
All as per item No 96 here-in-before but 24-40 Amp.
All as per item No 96 here-in-before but 45-75 Amp.
All as per item No 96 here-in-before but 66-110 Amp.
Supply and fixing for copper conductor cable 25 Sqmm, single core in short pices as per requirement complete including dismantling the old burnt cable of existing panel including necessary repalcement of copper lugs of suitable size with washers all as specified and as directed.
Supply and fixing in replacement of column pipe 50mm dia bore made of meduim grade GI pipe, 10 feet long both ends flanged & drilled including cutting of groves for submersible cable complete including lowering/ lifting at any places of AF Palam all as specified and as directed.
All as per item No 103 here-in-before but 80mm dia pipe complete.
S&F in replacement of lead acid battery 12Volts 180 AH of existing type & size suitable for Gen sets 15 to 125 KVA inculding initial charging complete.
Servicing of liquid chlorine dosing system, any make, any type/capacity complete including replacement of chlorine dosing pipe upto 2.5 Mtr length for each plant including servicing of motor, washing of chlorine tank with anti scaling agent and re-comissioning, testing of plant complete all as specified and as directed.
Supply & fixing in replacement of phase sequence corrector 3 phase 415 Volts with time delay relay with and including input supply, reverse phase protection against sigle phasing, voltage unbalancing, low voltage, high voltage etc. with necessery copper connections all as specified and directed. Make - SECO Model RPC-07 or equivalent in L & T/Legrand.
Material & Labour for painting to existing centifugal motor & pumping set complete including base frame with super enameled paint of existing colour coat by spray painting and writing of SM/MES No with white paint, 40 to 50 HP capacity all as specified and directed.
All as per item No 108 here-in-before but 15 to 25 HP capacity.
All as per item No 108 here-in-before but 3 to 5 HP capacity.
Supply and fixing in repair Auto timer clock as per existing complete all as specified and directed.
Supply and fixing and connecting in replacement of on load change over switch TPN 4 pole 200 Amp 440 volts conforming to relevant IS including all connecting and jointing material all as specified.
All as per items No. 113 here-in-before but 100 Amp 440 volts.
Supply on CDD 5000 (two components chlorine dioxide powder) (CAS No 10049-04-4 conforming to ISO9001-2015) white in colour highly soluble in water, 99.9% effective against water borne micro organisms disinfectant for chlorination of water.
S&F for 80mm bore cast iron non return valve as per IS:5312,Part-I with by pass arrangement both end flanged and drilled holes with suitable 3mm thick rubber insertion, bolt and nuts including taking out the unserviceable valve all as specified.
S&F for 100mm bore cast iron non return valve as per IS:5312,Part-I with by pass arrangement both end flanged and drilled holes with suitable 3mm thick rubber insertion, bolt and nuts including taking out the unserviceable valve all as specified.
S&F for 150mm bore cast iron non return valve as per IS:5312,Part-I with by pass arrangement both end flanged and drilled holes with suitable 3mm thick rubber insertion, bolt and nuts including taking out the unserviceable valve all as specified.
Taking up old/ corroded MS bolts from sluice valve, pump, MS bolt and nuts for flange joints of size not exceeding (5 / 8") 16mm dia of any length including supply and replace with new bolts, nuts and washers all as directed
Supply and laying in replacement of 100mm bore GI tubing medium grade with all fittings such as bends, tees, nipples, check nuts, union etc., in trenches/ fixed on walls/ roof/ fixed inside the shallow well. (Note: Earth work and excavation shall be measured and paid separately under relevant items).
All as per item No 120 above but 80mm bore pipe.
All as per item No 120 above but 50mm bore pipe.
All as per item No 120 above but 40mm bore pipe.
All as per item No 120 above but 25mm bore pipe.
All as per item No 120 above but 20mm bore pipe.
All as per item No 120 above but 15mm bore pipe.
S&F in replacement of 50mm dia gun metal gate valve non rustable spindle with cast iron wheel as and when required ISI marked suitable for screwing in GI pipes.
All as per item No 127 above but 40mm dia.
All as per item No 127 above but 25mm dia.
All as per item No 127 above but 20mm dia.
All as per item No 127 above but 15mm dia.
S&F in repairs GI coated MS flange of 8mm thick with suitable size drilled holes and suitable for screwing in GI pipe of 100mm bore complete.
S&F in repairs GI coated MS flange of 8mm thick with suitable size drilled holes and suitable for screwing in GI pipe of 80mm bore complete.
S&F in repairs GI coated MS flange of 8mm thick with suitable size drilled holes and suitable for screwing in GI pipe of 50mm bore complete.
S&F in repairs GI coated MS flange of 8mm thick with suitable size drilled holes and suitable for screwing in GI pipe of 40mm bore complete.
S&F in repairs Cast iron sluice valve with cast iron wheel stainless steel spindle water quality conforming IS-14846/2000, Class PN - 1/1.6 short bodies ISI marked as and when required of 150mm dia.
S&F in repairs Cast iron sluice valve with cast iron wheel stainless steel spindle water quality conforming IS-14846/2000, Class PN - 1/1.6 short bodies ISI marked as and when required of 100mm dia.
S&F in repairs Cast iron sluice valve with cast iron wheel stainless steel spindle water quality conforming IS-14846/2000, Class PN - 1/1.6 short bodies ISI marked as and when required of 80mm dia.
S&F in repairs Cast iron sluice valve with cast iron wheel stainless steel spindle water quality conforming IS-14846/2000, Class PN - 1/1.6 short bodies ISI marked as and when required of 200mm dia.
S&F in repairs 3mm thick rubber insertion along with suitable size nuts and bolts for flanged joint.
Excavation in trenches n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in any type of soil.
Returning, filling in soil including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick
Removing the excavated surplus soil to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point
M&L for 150mm bore ductile iron pipe with spigot and socket ends, cetrifugaly cast, class-K-9 (IS-8329-2000) suitable for tytan joints, in any length, laid in trenches/pillar complete.
M&L for 100mm bore ductile iron pipe with spigot and socket ends, cetrifugaly cast, class-K-9 (IS-8329-2000) suitable for tytan joints, in any length, laid in trenches/pillar complete.
Taking up 80mm bore CI/DI water main including all fittings with spigot socket ends and lead/tyton joints including burning out lead joints and recovering lead for reuse or deposited to MES store yard.
Taking up 100mm bore CI/DI water main including all fittings with spigot socket ends and lead/tyton joints including burning out lead joints and recovering lead for reuse or deposited to MES store yard.
Taking up 150mm bore CI/DI water main including all fittings with spigot socket ends and lead/tyton joints including burning out lead joints and recovering lead for reuse or deposited to MES store yard.
Laying only in trenches the old serviceale 80mm bore CI/DI pipes with socket and spigot ends complete with all fittings after cleaning thoroughly and removal of all blockages by using splitted bamboos /steel rod effectively complete all as specified and directed by Engineer-in-Charge. (Note : (a) Pipes taken up /obtained from item No. 146. (b) Joints and CI fittings shall be measured and paid for separately).
Laying only in trenches the old serviceale 100mm bore CI/DI pipes with socket and spigot ends complete with all fittings after cleaning thoroughly and removal of all blockages by using splitted bamboos /steel rod effectively complete all as specified and directed by Engineer-in-Charge. (Note : (a) Pipes taken up /obtained from item No. 147. (b) Joints and CI fittings shall be measured and paid for separately).
Laying only in trenches the old serviceale 150mm bore CI/DI pipes with socket and spigot ends complete with all fittings after cleaning thoroughly and removal of all blockages by using splitted bamboos /steel rod effectively complete all as specified and directed by Engineer-in-Charge. (Note : (a) Pipes taken up /obtained from item No. 148. (b) Joints and CI fittings shall be measured and paid for separately).
Surface excavation in hard/dense soil, not exceeding 30 cm deep and average 15cm deep for cleaning the pump house area and all area by cutting the unwanted bushes/vegitation growth in and around the area of installations/around the valve pit chamber/along the pipe line routes if reqd etc all as directed by Engr -in-charge
S&F in repairs CI/DI specials like collar, Tees, Socket, bend taper etc suitable for pipe of size upto 150mm bore.
All as per item No.153 above but CI/DI pipe of size 200mm to 300mm bore.
M&L for run lead joint including all necessary jointing materials complete (old recovered lead from the leaking joint shall not be reused) for pipe of 250mm bore.
M&L for run lead joint including all necessary jointing materials complete (old recovered lead from the leaking joint shall not be reused) for pipe of 200mm bore.
M&L for run lead joint including all necessary jointing materials complete (old recovered lead from the leaking joint shall not be reused) for pipe of 150mm bore.
M&L for run lead joint including all necessary jointing materials complete (old recovered lead from the leaking joint shall not be reused) for pipe of 100mm bore.
M&L for run lead joint including all necessary jointing materials complete (old recovered lead from the leaking joint shall not be reused) for pipe of 80mm bore.
Cutting only cast iron pipes in position for insertion of new tees, branches etc complete for pipe of size 150 mm bore.
Cutting only cast iron pipes in position for insertion of new tees, branches etc complete for pipe of size 100 mm bore.
Cutting only cast iron pipes in position for insertion of new tees, branches etc complete for pipe of size 80 mm bore.
M&L for cutting the bituminous road of any description to a size n.exc 0.45m x 0.45m for crossing of pipe and making good with cement concrete 1:3:6 type C-1 using 20mm graded stone aggregate all as specified and directed by Engr-in-Charge.
S&F in replacement of cast iron foot valve flanged type including nuts, bolts, washers and rubber of 150 mm dia confirming to IS-4038 complete.
S&F in replacement of cast iron foot valve flanged type including nuts, bolts, washers and rubber of 100 mm dia confirming to IS-4038 complete.
M&L for construction of brick masonary valve chamber of size 900mmx900mmx9000mm(internal dimensions) with 150mm thick cement concrete 1:4:8 type D-2 in foundation, brick masonary built in CM 1:6, cement concrete 50mm thick in 1:3:6 type C-1 using 20mm graded stone aggregate in coping , cement plaster 15mm thick in cement mortar 1:6 to brick work/ concrete surface including provision of 3mm thick MS sheet cover with locking arrangement and embedded with angle iron of size 40mmx40mmx6mm duly painted with two coats of synthetic enamal paint over a coat of red oxide primer complete all as specified.
Draining out water from under ground sump, removing silt, algea growth, brushing and washing all internal surfaces, white washing outer side walls and roof including writing letter in bold with white paint of size not exceeding 10 cms height on black back ground such as sump capacity, cleaned on and due date of cleaning etc., of capacity (Sump of capacity 50,000 gallons)
Draining out water from under ground sump, removing silt, algea growth, brushing and washing all internal surfaces, white washing outer side walls and roof including writing letter in bold with white paint of size not exceeding 10 cm height on black back ground such as sump capacity, cleaned on and due date of cleaning etc for sump of capacity 35,000 gallons.
Draining out water from under ground sump, removing silt, algea growth, brushing and washing all internal surfaces, white washing outer side walls and roof including writing letter in bold with white paint of size not exceeding 10 cm height on black back ground such as sump capacity, cleaned on and due date of cleaning etc for sump of capacity 30,000 gallons.
Draining out water from over head reservoir , removing silt, algea growth, brushing and washing all internal surfaces, white washing outer side walls and roof including writing letter in bold with white paint of size not exceeding 10 cm height on black ground such as OHR capacity, cleaned on and due date of cleaning etc for overhead reservior of capacity 1,00,000 gallons.
Draining out water from over head reservoir , removing silt, algea growth, brushing and washing all internal surfaces, white washing outer side walls and roof including writing letter in bold with white paint of size not exceeding 10 cm height on black ground such as OHR capacity, cleaned on and due date of cleaning etc for overhead reservior of capacity 50,000 gallons.
Draining out water from over head reservoir , removing silt, algea growth, brushing and washing all internal surfaces, white washing outer side walls and roof including writing letter in bold with white paint of size not exceeding 10 cm height on black ground such as OHR capacity, cleaned on and due date of cleaning etc for overhead reservior of capacity 15,000 gallons.
Draining out water from over head reservoir , removing silt, algea growth, brushing and washing all internal surfaces, white washing outer side walls and roof including writing letter in bold with white paint of size not exceeding 10 cm height on black ground such as OHR capacity, cleaned on and due date of cleaning etc for overhead reservior of capacity 12,000 gallons.
Supply Only Disinfection hypo chlorine based having chlorine percentage 5-6 % in 40 Ltr jar complete.
Taking up or down electric motor and pump of 15 HP to 50 HP of any make or type after disconnecting from all the misc items such as NRV, reducer, CI-Tee, pipelines etc and electric connection as all required at site including dismantling and taking out old rusted steel/iron channel/ foundation, vibration pad after taking all safety measures including all lifting work,welding work if any, cutting and supply and fixing vibration pad in six numbers and one steel/iron channel/motor foundation of size suitable for motor and pump of 15 HP to 50 HP,fixing the motor and pump of above said capacity and fixing all connecting items including NRV, reducer, CI-Tee, Pipelines with all minor work such as cutting, welding, electric connection ,nut, bolts, gland, flange etc of any size and make all as specified and directed by Engr-in-charge,
M&L for flushing of existing borewell of size upto 300mm dia, depth upto 200 mtr with drilling compressor capacity not less than 620 CFM including surging and flushing the bore at a pressure of 8 kg/ sqcm minimum 8 hrs complete with compressed air and flushing the sand, mud etc from the bore well complete including disconnecting and lifting out of existing submerssible pumpst from borewell upto 10 HP capacity along with their column pipes and submerssible cable from borewell from any depth and lowering after flushing existing borewell complete.
S&F in replacement of display board for showing details/ Schematic diagram (provided by Engr-in-Charge) of pump houses and borewells made out of phiroza blue/ white colour PVC sheet of size 2 mtrX1 mtr including GI angle frame of thickness gauge 13 and GI sheet cover to the frame and fixing of 3 Nos LED tube light fittings 20 watts inside the frame, making arrangement to replace the LED tube light, connecting electrical supply to the frame with 1.5 sqmm 2 core copper PVC cable and conduit pipe including round steel pole minimum 12 feet long of suitable dia for erection on ground with cement concrete 1:2:4 type B-1 of required size and depth complete all as specified and directed by Engineer-in-charge.
S&F in replacement of Retro Reflective Board of size 5 feet x 4 feet made out fine quality PVC sheet duly framed with aluminium moulding and provided with hanging arrangement including writing the details of the pumpset installed (provided by Engr-in-Charge) complete all as specified.
Commercial Traders
M/S Satyam Associates
AARYANS GLOBAL INDIA
Rohan Construction Company
Sumit Enterprises
AMIT ENTERPRISES
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .