Loading…
Loading…
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹49,980
Closing Date
23 Oct 2026, 6:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GE NEW DELHI
GE NEW DELHI, SP MARG NAR ABHM GATE NO 5
REPAIR/ MAINT OF COOLING APPLIANCES WINDOW/ SPLIT/ CASSETTEE/ TOWER/ PACKAGE TYPE ACS DEEP FREEZER, RO, WATER COOLERS AND DESERT COOLERS IN NAVY AREA UNDER GE NEW DELHI
2026_MES_787993_2
NIT No GE/ND-59/2026-27
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NEW DELHI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE NEW DELHI
₹49,980
Yes
9 Oct 2026
9 Oct 2026
26 Oct 2026
9 Oct 2026
23 Oct 2026
16 Oct 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Labour for checking and attending complaints of ACs, water coolers, deep freezer, RO, Desert cooler, Refrigerators etc. of any capacity, including rectification of minor defects and making the equipment functional complete all as specified and directed.
Note: (a) The contractor should detail minimum one AC Mechanic & one helper to attend complaints in Navy Area and he must submit copy of valid competency certificate of two (2) AC mechanics each having minimum working experience of two years in the field of air conditioning & refrigeration. The certificates shall be issued by the OEM only stating the technical qualification & experience of the mechanics to be deployed, and these certificates shall be submitted to Engr in charge and same will be verified by Engr in charge and submit a physical copy in the office of GE, after acceptance of contract failing which contract is liable to be cancelled. The said certificates shall also forwarded by OEM through mail on e-mail id [email protected]
(b) Any parts required for replacement shall be measured and paid separately under respective items.
(c) The minor complaint should be attended within 2 hours.
(d) If the complaint will not attended/not completed within 2 hrs, recovery will be done as follows:-
(i) Attending between 2-4 Hours @ Rs 1000
(ii) Between 4-12 hrs @ Rs 2000/-
(iii) For next every 12 hrs @ Rs 5000/- | 80 | Each complaint | - | - |
| 2 | Servicing of Split type AC 1.5/2 Ton capacity of any make / model by taking out the AC, Cleaning of evaporating coil, condensing coil with water & brush to remove dust including cleaning of filter, greasing, oiling of fan motor and checking of electric circuit for smooth functioning of AC complete all as specified and directed.
Note: Unserviceable spares parts required to be replaced shall be measured and paid separately under respective items. | 80 | Each Job | - | - |
| 3 | Supply only in replacement starting capacitor 80-100 Mfd suitable for AC 1.5 Ton complete all as specified and directed.
Make: Usha/Epcos/Havells/Tesla | 10 | Each | - | - |
| 4 | Supply only in replacement starting capacitor 100-120 Mfd suitable for AC upto 2.0 Ton complete all as specified and directed.
Make : Arcos/Epcos/Tesla | 5 | Each | - | - |
| 5 | Supply only in replacement Running capacitor 36 mfd 230 volt suitable for AC 1.5 Ton complete all as specified and directed.
Make : Arcos/Epcos/Tesla | 8 | Each | - | - |
| 6 | Supply only in replacement Running capacitor combination 50 mfd + 6 mfd 230 Volt for AC upto 2.0 Ton complete all as specified and directed.
Make : Arcos/Epcos/Tesla | 8 | Each | - | - |
| 7 | Supply only in replacement Running capacitor 6 mfd 230 volt complete all as specified and directed.
Make : Arcos/Epcos/Tesla | 5 | Each | - | - |
| 8 | Supply only in replacement Running capacitor 4 mfd 230 volt complete all as specified and directed.
Make :- Arcos/Epcos/Tesla | 8 | Each | - | - |
| 9 | Supply & charging gas refrigerant R-22/R 410 A/ R-32 or as existing to split type AC up to 2 Ton capacity and testing complete all as specified and directed by Engineer-in-charge.
Make: Mafron/Refron/Refromax | 10 | Each Job | - | - |
| 10 | S&F in replacement starting relay suitable for 1.5/2 Ton capacity AC complete all as specified and directed. | 7 | Each | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.25 MB
NIT59.pdf
Additional Documents • 0.23 MB
Tender59.pdf
Tender Documents • 0.78 MB
BOQ_889464.xls
BOQ • 1.15 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .