Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹13.4 LAccepted-AOC 7 142 THOTILIL PATTY SALEM CAMP PO METTUR DAM 636 456 | METTUR DAM | SALEM | TAMIL NADU | 636456 | ₹13.4 L Quoted ₹13.1 L | 1 | Accepted-AOC L1 |
| 2 | 2₹14.9 LRejected-AOC 3 140 H 1 PERIYAR STREET AMMAN NAGAR METTUR DAM 636 401 | METTUR DAM | SALEM | TAMIL NADU | 636401 | ₹14.9 L | 2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | SS ENGINEERING CONTRACTOR L2 | SKSCONTRACTOR L1 |
|---|---|---|---|---|---|
| 1.00 | Charges for loading and unloading of new M.S pipes and Reducers required for pipe replacement in the existing Hot water basin header from stores to work spot.( For loading & Unloading Lorry & Crane will be supplied by TANGEDCO at free of cost). | 25.95 | mtr | 250 ₹6,487.50 | 240 ₹6,228 |
| 2.00 | Charges for marking & cutting the corroded and eroded MS hot water pipe of size 1600mm Ø, 1400mm Ø ,1000mm Ø, 457mm Ø & its flanges and 1600/1400 Ø, 1400/1000 Ø reducers in the existing Hot water header pipe line at eastern side of the cooling tower for pipe replacement work [The required Material of size 1600mm Ø, 1400mm Ø, 1000mm Ø pipes, 1600/1400 Ø, 1400/1000 Ø reducers will be supplied by TANGEDCO]. | 10,078 | kg | 40 ₹4.0 L | 35 ₹3.5 L |
| 3.00 | Charges for erecting the new MS pipe of size 1600mm Ø, 1400mm Ø 1000mm Ø, 457mm Ø & its flanges, 1600/1400 Ø, 1400/1000 Ø reducers in the existing Hot water header pipe line at eastern side of the cooling tower and devolution of the removed corroded and eroded pipe to Central stores/MTPS-I. | 10,078 | kg | 70 ₹7.1 L | 60 ₹6.0 L |
| 4.00 | Charges for Edge preparation and welding the new laid MS Pipe of size 1600mm Ø, 1400mm Ø 1000mm Ø, 457mm Ø pipe with 10 mm thickness and MS flange of OD 635 Ø, ID 477 mm Ø, 16 mm Thick, M.S. Eccentric Reducer 1600/1400 mm dia 10 mm thickness & M.S. Eccentric Reducer 1400/1000 mm dia 10 mm thickness in the existing hot water header at eastern side of the cooling tower. | 249 | mtr | 650 ₹1.6 L | 600 ₹1.5 L |
| 5.00 | Charges for painting with one coat of epoxy red oxide primer and one coat of epoxy coal thar black paint on the inner surface of newly laid MS Pipe & Reducers. | 112 | m2 | 170 ₹19,040 | 160 ₹17,920 |
| 6.00 | Cost of 1 No. M.S. pipe of ID 457 mm dia, 10 mm thickness, 600 mm length | 8 | Nos | 7,000 ₹56,000 | 6,500 ₹52,000 |
| 7.00 | Cost of 1 No. M.S. Flange of OD 635 mm, ID 477 mm, Thickness 16 mm | 9 | Nos | 2,500 ₹22,500 | 2,000 ₹18,000 |
| 8.00 | Cost of Epoxy red oxide primer for SL.No.5 | 12 | liter | 250 ₹3,000 | 240 ₹2,880 |
| 9.00 | Cost of Coal Thar Black Paint for Sl.No.5 | 21 | liter | 250 ₹5,250 | 230 ₹4,830 |
| 10.00 | Cost of Epoxy Thinner for SL.No.5 | 8 | liter | 200 ₹1,600 | 180 ₹1,440 |
Tender Value
Refer Docs
EMD Value
₹12,300
Closing Date
15 Oct 2024, 2:00 pmClosed
Superintending Engineer /Mechanical-I/MTPS-I
Office of the Superintending Engineer / Mechanical -I Mettur Thermal Power Station- I Mettur Dam-636406
MTPS I M I CA CWS I Renewal Replacement of most corroded and eroded pipes of size 1600mm dia, 1400mm dia, 1000mm dia, 457mm dia and its flanges etc
2024_EB_490140_1
CE / MTPS-I / SE / M-I / CA /OT. 209 / 2024-25
Open Tender
Power/Energy Projects/Products
45 days
Mettur Thermal Power Station-I / Mettur Dam
As per the Tender Specifications
4 documents required · 4 mandatory
₹0
₹12,300
Yes
19 May 2026
1 Oct 2024
16 Oct 2024
1 Oct 2024
15 Oct 2024
1 Oct 2024
Amount
Charges for loading and unloading of new M.S pipes and Reducers required for pipe replacement in the existing Hot water basin header from stores to work spot.( For loading & Unloading Lorry & Crane will be supplied by TANGEDCO at free of cost).
Charges for marking & cutting the corroded and eroded MS hot water pipe of size 1600mm Ø, 1400mm Ø ,1000mm Ø, 457mm Ø & its flanges and 1600/1400 Ø, 1400/1000 Ø reducers in the existing Hot water header pipe line at eastern side of the cooling tower for pipe replacement work [The required Material of size 1600mm Ø, 1400mm Ø, 1000mm Ø pipes, 1600/1400 Ø, 1400/1000 Ø reducers will be supplied by TANGEDCO].
Charges for erecting the new MS pipe of size 1600mm Ø, 1400mm Ø 1000mm Ø, 457mm Ø & its flanges, 1600/1400 Ø, 1400/1000 Ø reducers in the existing Hot water header pipe line at eastern side of the cooling tower and devolution of the removed corroded and eroded pipe to Central stores/MTPS-I.
Charges for Edge preparation and welding the new laid MS Pipe of size 1600mm Ø, 1400mm Ø 1000mm Ø, 457mm Ø pipe with 10 mm thickness and MS flange of OD 635 Ø, ID 477 mm Ø, 16 mm Thick, M.S. Eccentric Reducer 1600/1400 mm dia 10 mm thickness & M.S. Eccentric Reducer 1400/1000 mm dia 10 mm thickness in the existing hot water header at eastern side of the cooling tower.
Charges for painting with one coat of epoxy red oxide primer and one coat of epoxy coal thar black paint on the inner surface of newly laid MS Pipe & Reducers.
Cost of 1 No. M.S. pipe of ID 457 mm dia, 10 mm thickness, 600 mm length
Cost of 1 No. M.S. Flange of OD 635 mm, ID 477 mm, Thickness 16 mm
Cost of Epoxy red oxide primer for SL.No.5
Cost of Coal Thar Black Paint for Sl.No.5
Cost of Epoxy Thinner for SL.No.5
Cost of welding electrode for Sl.No.4
Charge for Hire charges of Welding machine for SL.No.4
Cost of cutting Gas for Sl.No.2
Consumable and T&P Cost for SL.No.1 to 5
SS ENGINEERING CONTRACTOR (BID ID -1162242)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.72 MB
BOQ_582355.xls
BOQ • 0.34 MB
Download all tender documents and submit your bid