| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.9 LAccepted-AOC 71 BALU BANKER COLONY P O DHORI 825102 JHARKHAND | BOKARO | JHARKHAND | 825102 | L1 | Accepted-AOC L1 bidder is techno commercially qualified. | |
| 2 | L2₹12.5 L−₹14,582 (1.16%)Rejected-Finance AT OLD B D O OFFICE MAIN ROAD PHUSRO DIST BOKARO JHARKHAND | BOKARO | JHARKHAND | 825102 | L2 | Rejected-Finance Bid not be opened as per NIT terms. | |
| 3 | L3₹12.9 L+₹27,627 (2.19%)Rejected-Finance | L3 | Rejected-Finance Bid not be opened as per NIT terms. |
Tender Value
₹14.2 L
EMD Value
₹17,800
Closing Date
28 Dec 2024, 10:00 amClosed
SO(EnM), Dhori
Office of the General Manager, Dhori, Po- Dhori, Bokaro, pin-825102
Repairing and Replacement of damage component of 12 nos. Lighting transformer of different capacities installed at different location under gm unit, Dhori Area.
2024_CCL_323503_4
GM(D)/SO(EnM)/DA/24-25/53
Open Tender
Electrical and Maintenance Works
Item Wise
25 days
GM unit
please refer tender documents
2 documents required · 2 mandatory
₹17,800
1 Aug 2025
17 Dec 2024
30 Dec 2024
18 Dec 2024
28 Dec 2024
18 Dec 2024
18 Dec 2024 - 23 Dec 2024
Amount
PART A repairing , painting and reconditioning of 250 kva ,11kv/440v trnasformer for power supply to pumps installed at Kargali river side filter plant
Replacement of drain valv, size-1"
Replacement of nuts, bolts, washer, and tio rods.
Providing of spout bushing insulator with stud set primary side.
Providing & fixing of all gaskit at tanki cover, primary & secondary side insulator points, Conservator tanki pipe joints, oil indication place, drain valve joints, etc places
Testing, checking and commissioning of lighting transformer at site
PART B Repairing, painting and reconditioning of 315KVA, 11KV/440V lighting transformer for power supply of central hospital and colony installed at CHD S/S of GM unit Dhori Area.
Providing of spout bushing insulator with stud set primary side.
Replacement of drain valv, size-1"
Providing & fixing of all gaskit at tanki cover, primary & secondary side insulator points, Conservator tanki pipe joints, oil indication place, drain valve joints, etc places
Testing, checking and commissioning of lighting transformer at site
PART C Repairing, painting and reconditioning of 500KVA, 11KV/440V lighting transformer for power supply of hospital and its colony installed at CHD S/S of GM unit Dhori Area.
Replacement of drain valv, size-1"
Providing of spout bushing insulator with stud set primary side.
Providing & fixing of all gaskit at tanki cover, primary & secondary side insulator points, Conservator tanki pipe joints, oil indication place, drain valve joints, etc places
Online filtration/dehydration of transformer oil
Testing, checking and commissioning of lighting transformer at site
PART DRepairing, painting and reconditioning of 100KVA, 11KV/440V lighting transformer for power supply of C&D type Qtrs in GM colony installed at S/S of GM unit, Dhori Area.
Replacement of drain valv, size-1"
Providing of spout bushing insulator with stud set primary side.
Providing & fixing of all gaskit at tanki cover, primary & secondary side insulator points, Conservator tanki pipe joints, oil indication place, drain valve joints, etc places
Testing, checking and commissioning of lighting transformer at site
PART E Repairing, painting and reconditioning of 100KVA, 11KV/440V lighting transformer for power supply of CHD Back feeder installed at S/S of GM unit, Dhori Area.
Providing of spout bushing insulator with stud set primary side.
Raditor cleaning and fitting
Complete body cleaning, Double coat primer and Enamel painting by Spray painting machine including cost of cleaning and painting materils as well as labour cost, 100KVA, 11KV/440V lighting transformer
Testing, checking and commissioning of lighting transformer at site
PART F Repairing, painting and reconditioning of 100KVA, 11KV/440V lighting transformer for power supply of GM office installed at S/S of GM unit, Dhori Area.
Replacement of drain valv, size-1"
Replacement of nuts, bolts, washer, and tio rods.
Providing of spout bushing insulator with stud set primary side.
Testing, checking and commissioning of lighting transformer at site
PART G Repairing, painting and reconditioning of 300KVA, 3.3KV/550V transformer for power supply of water supply pump at pure Dhori Balu banker, GM unit, Dhori area.
Raditor cleaning and fitting
Online filtration/dehydration of transformer oil
Complete body cleaning, Double coat primer and Enamel painting by Spray painting machine including cost of cleaning and painting materils as well as labour cost.
Providing of spout bushing insulator with stud set primary side.
Testing, checking and commissioning of lighting transformer at site
PART H Repairing, painting and reconditioning of 100KVA, 3.3KV/440V lighting transformer for lighting purpose installed at pure Dhori river side installed at GM unit, Dhori Area.
Providing of spout bushing insulator with stud set primary side.
Replacement of nuts, bolts, washer, and tio rods.
Testing, checking and commissioning of lighting transformer at site
PART I Repairing, painting and reconditioning of 160KVA, 11KV/440V lighting transformer for power supply of masjid muhallah installed at Raja banglow S/S under GM unit, Dhori Area.
Replacement of nuts, bolts, washer, and tio rods.
Replacement of drain valv, size-1"
Raditor cleaning and fitting
Providing of spout bushing insulator with stud set primary side.
Testing, checking and commissioning of lighting transformer at site
PART J Repairing, painting and reconditioning of 200KVA, 11KV/440V lighting transformer for power supply of Dhori basti installed at Raja banglow S/S of GM unit, Dhori Area.
Providing of spout bushing insulator with stud set primary side.
Providing & fixing of all gaskit at tanki cover, primary & secondary side insulator points, Conservator tanki pipe joints, oil indication place, drain valve joints, etc places
Online filtration/dehydration of transformer oil
Testing, checking and commissioning of lighting transformer at site
PART K Repairing, painting and reconditioning of 500KVA, 11KV/440V lighting transformer for power supply of MQ type and "C" type qtr of GM colony installed at Raja Banglow S/S , GM unit Dhori Area.
Providing of spout bushing insulator with stud set primary side.
Replacement of drain valv, size-1"
Providing & fixing of all gaskit at tanki cover, primary & secondary side insulator points, Conservator tanki pipe joints, oil indication place, drain valve joints, etc places
Testing, checking and commissioning of lighting transformer at site
Supervision , incidental & overhead expenses
PART L-Repairing rewinding of 01 no 250 kva 11kv/440v transformer of GM office Dhori
Complete repairing of all 3 limbs of HT side.
Complete repairing of all 3 limbs of LT side.
Charging of insulating materila ( 15% of Sl.no. 1.61 and 1.62)
labour cost ( 15% of Sl.no. 1.61 and 1.62)
scrap value deduction ( 60% of Sl.no. 1.61 and 1.62)
Total impact of GST for the purpose of CTC
Balajee Traders (BID ID -1112424)
M/S SHREE TIRUPATI TRADERS (BID ID -1112439)
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .