| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC NO 68 ANJANEYA TEMPLE CROSS OPP M S RAMAIAH HOSPITAL NEW BEL ROAD BANGALORE 560 094 | BENGALURU URBAN | KARNATAKA | 560094 | L1 | Accepted-AOC L1 | |
| 2 | L2₹23.0 L+₹1.8 L (8.27%)Rejected-AOC | L2 | Rejected-AOC L2 |
Tender Value
₹24.5 L
EMD Value
₹49,000
Closing Date
15 Jun 2020, 6:00 pmClosed
Shri Vineet Modi
CWE AF North Bangalore Bellary Road JC Nagar Post Bangalore 560006
MAINTENANCE OF TRANSFORMERS/ VCB/ HT INSTALLATIONS INCLUDING FILTERATION AT VARIOUS LOCATIONS UNDER GE (AF) MARATHAHALLI, BANGALORE
2020_MES_345910_1
87556CWEAFNMAR
Open Tender
Miscellaneous Works
Item Rate
330 days
GE AF MARATHAHALLI
AS PER NIT
5 documents required · 5 mandatory
₹500
GE AF MARATHAHALLI
₹49,000
Yes
11 Aug 2020
19 May 2020
17 Jun 2020
19 May 2020
15 Jun 2020
3 Jun 2020
20 May 2020 - 30 May 2020
Amount
Taking out carefully unserviceable end termination joint, Supply and fix cable jointing kit for 11KV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185sqmm.complete all as directed.Make:-Raychem/Densons/M-Seal/Birla-3M/Yamuna gases and Chemical.
All as per item No.01 above, but suitable for 3 core XLPE armoured Aluminium conductor cable of size 240 to 300 sqmm. .Make:-Raychem/Densons/M-Seal/Birla-3M/Yamuna gases and Chemical.
All as per item No.01 above, but for indoor type termination cold shrink type joint suitable for 3 core XLPE armoured Aluminium conductor cable of size 120 to 185 sqmm. .Make:-Raychem/Densons/M-Seal/Birla-3M/Yamuna gases and Chemical.
All as per item No.01 above, but for indoor type termination cold type joint suitable for 3 core XLPE armoured Aluminium conductor cable of size 240to 300 sqmm. .Make:-Raychem/Densons/M-Seal/Birla-3M/Yamuna gases and Chemical. Note for Sl No. 1 to 4 : The quoted rate is deemed to be included for complete earth work wherever applicable, taking out existing sand, PCC Cover, GI pipe, old cable from trench/ existing loop etc and set a side carefully for reuse in and including relaying of old cable after new jointing works properly, spreading existing sand for cable cushioning, relaying PCC cover, GI pipe, returning & refilling soil complete, making good with adjacent areas complete all as specified and directed by Engineer-in-charge.
S&F in replacement of straight through joint kit (Cold shrinkable) suitable for XPLE underground aluminium conductor cable 11000 Volt grade of cross sectional area120 Sqmm to 185 Sqmm x 3 Core including testing after jointing complete all as specified and as directed by Engineer-in-Charge. .Make:-Raychem/Densons/M-Seal/Birla-3M/Yamuna gases and Chemical.
All as per item No.05 above, but suitable for 3 core XLPE armoured Aluminium conductor cable of size 240 Sqmm to 400 Sqmm x 3 Core . .Make:-Raychem/Densons/M-Seal/Birla-3M/Yamuna gases and Chemical. Note for Sl No. 5 to 6 : The quoted rate is deemed to be included for complete earth work wherever applicable, taking out existing sand, PCC Cover, GI pipe, old cable from trench/ existing loop etc and set a side carefully for reuse in and including relaying of old cable after new jointing works properly, spreading existing sand for cable cushioning, relaying PCC cover, GI pipe, returning & refilling soil complete, making good with adjacent areas complete all as specified and directed by Engineer-in-charge.
Supply and laying in replacement HT XLPE insulated, screened PVC bedded, galvanized steel strip or wire armoured, electric power cable ( heavy duty ) with aluminium conductor 11000 volt grade (UE), cross sectional area 185 Sqmm, 3 core conforming to IS-7098 (Part-I) laid in trenches / under floor / roads / along poles etc. all as specified and directed by Engineer-in-Charge. (Excavation, returning and refilling shall be measured and paid separately under relevant items, however the cost is to be deemed to be included for taking out sand, PCC cover, GI pipe, MS clamps etc properly from the trench/ structures etc and kept a side carefully and relaying sand, PCC cover, refixing GI pipe, MS clamp etc as per site requirements complete all as specified and directed by Engineer-in-charge..
Excavation in trenches in soft/loose soil not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations laying of U/G cable etc. and getting out complete all as specified and as directed by Engineer-in-Charge.
Excavation in trenches in soft/loose not exc. 1.5m wide and not exc. 3.0 m in depth and getting out complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick with soft/loose soil.
Removing surplus spoil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified and as directed by Engineer-in-Charge.
M & L for replacement for G.I. tubing light grade of size 80mm bore for protection of cables to be laid under roads, crossings/culverts complete all as specified and directed. Make:-Tata/Jindal/Zenith/Swastik/Prakash.
Demolition of cement concrete (un-reinforced) in ground floors and paving not exceeding 15 cm thickness (below or above ground level ) complete all as specified and as directed by Engineer-in-Charge
Plain cement concrete 1:4:8 type D-2 using 40 mm graded stone aggregates, as in foundation of poles, and stay filling and mass concrete complete all as specified and as directed by Engineer-in-Charge.
Plain cement concrete 1:3:6 type C-1 using 20 mm graded stone aggregates, as copping of poles complete all as specified and as directed by Engineer-in-Charge.
Material and labour for boring of holes under road, pavement hard standing by trenchless technology using ultra sound technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure.complete all as directed.
M & L for pin pointing fault of faulty 11 KV HT cables by using HT cable fault locator machine and highpot testing at 22 KV after removing the fault complete all as specified and as directed by the Engineer-in-Charge. Note : The quoted rate is deemed to be included for complete earth work wherever applicable, taking out existing sand, PCC Cover, GI pipe, old cable from trench/ existing loop etc and set a side carefully for reuse in and including relaying of old cable in and including supply, jointing using a new HT cable piece of suitable size as per site (if required) , relaying cable after jointing works, spreading existing sand for cable cushioning, relaying PCC cover, GI pipe, returing and refilling soil complete, making good with adjacent areas complete all as specified and directed by Engineer-in-charge.
Repair to GOD switch 11KV, HT mechanically operated vertical and horizontally operated by cleaning of moving/static contacts with tetra chloride solutioin scrapping and making smooth to existing spot points of the contracts by emery paper, providing grease on moving contacts mechanical torque joint, tightening of canopy with drop out fuse set ( three contracts in each GOD ) including replacement of the following unserviceable parts (a) ACSR Jumper with RYB, PVC sleeves 1.5M to 2 Mtr long - 03 Nos (b) Brass connector brackets with bolts, nuts etc - 03 set (c ) Copper lugs of suitable size (d) HT barrel fuses of suitable fuses - 03 Nos complete all as specified and as directed by Engineer-in-Charge.
Supply and fixing HT 11 KV GOD insulator in replacement shall be conforming to IS complete all as directed. Make:-Pactil mumbai/HEI/Atlas/Jaipuria brothers/Elpro. Electric.
Supply and fixing male contact jaw in replacement suitable for 200/400Amps rating, vertical/ horizontal GOD switch complete all as specified and as directed by Engineer-in-Charge. Make:-Pactil mumbai/HEI/Atlas/Jaipuria brothers/Elpro.
Supply and fixing Female contact in replacement suitable for 200/400 Amps rating, vertical/ horizontal GOD switch complete all as specified and as directed by Engineer-in-Charge. Make:-Pactil mumbai/HEI/Atlas/Jaipuria brothers/Elpro.
Repairing of locking arrangement devices of GOD with provision of locking arrangement including nuts, bolts, washers & strips complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement of Switch Air break gang operated outdoor Horizontal operated type HT 11000 volts triple pole, 400 Amps 3 insulator tilting/ rotating type with fixed contacts of phosphor bronze and moving contacts of copper , manually operating from ground level with operating mechanism including mild steel galvanized medium grade 25 mm bore operating rod pad locking arrangement arcing horns, flexible binding earthing blades rod and contacts without dropout fuse assembly and jumper with mink conductor line taps, clamps, colour coated Red, Yellow and Blue HT sleeves and fittings suitable for horizontally mounting supplied and fixed in repair complete all as specified and as directed by Engineer-in-Charge. Make:-Pactil mumbai/HEI/Atlas/Jaipuria brothers/Elpro
S&F Drop out expulsion fuse assembly with fuse carrier triple pole HT 11000 Volts, 400 Amps out door type I having two Nos post insulator mounted on MS channel for each pole ) and jumpers with conductors line taps clamps colour coated Red, Yellow and Blue HT sleeves and fitting and GI binding wire of suitable size supplied and fixed in repairs complete all as specified and as directed by Engineer-in-Charge. Make:-ABB/Areva T&D india ltd/Crompton greaves/Schnider/Andrew yule.
Taking down unserviceale single disc type insulator, Supply and fix Disc type porcelaine, vitreous, brown insulator, 145 mm height, 255 mm dia ball and socket type twin disc assembly 11000 Volts grade each set complete all as directed.Make:-BHEL/Jaysree/MEI/Southern insulator/WS insulator/Jaipuria brothers.
Taking down unserviceable discinsulator S&F Pin type porcelain, vitreous, white, brown or green insulator including one galvanized mild steel spindle, two GI washers and one GI nut. 150mm height, 150mm dia suitable for 11000 volts grade supplied and fixed in repairs complete all as specified and as directed by Engineer-in-Charge. Make:-BHEL/Jaysree/MEI/Southern insulator/WS insulator/Jaipuria .
Taking down unserviceale LA, Supply and fix Lightning arrestors expulsion type complete with all fittings transmission class, discharge capacity 65 KA suitable for 11000 Volts grade. complete all as directed.Make:-BHEL/Jaysree/MEI/Southern insulator/WS insulator/Jaipuria .
Taking down unserviceale ACSR conductor, Material and Labour for ACSR conductor of any size including stringing in position. Complete all as directed.Make:-All India/ICC/NICCO/Indian Aliminium co/Bharat conductors.
S&F in replacement of Galvanished steel wire, 4 mm dia including galvanized mild steel binding wire 1.63 mm dia or cradles, guards fabricated with galvanized steel wire 3.15 mm dia including binding with 1.63 mm dia galvanized steel wire complete all as specified and as directed by Engineer-in-Charge.
Taking down unserviceale Aluminium perished strip,Supply and fix Aluminium strip 25x3mm cutting,bending and fixing all as specified and directed.
Taking down unserviceale GI Strip,Supply and fix GI strip 25x 4 mm cutting,bending and fixing all as specified and directed.
Material and Labour hard core of gauge not exceding 40 mm, deposited, spread and levelled in layers not exceeding 15 cm thick including watering and rammed to a true surface.
Material and labour for painting of chain link fencing with two coat of aluminimum paint including preparation of new surfaces over a coat of aluminium red oxide primer.
supply and fixed in repairs Danger notice plate of size 25 cm x 20 cm x 1.60 mm thick, mild steel sheet, vitreous enameled white, with letters, figures and conventional skull & bones in signal red colour and fixed with MS clamps made out of 25 mm x 3 mm MS flat iron including bolts and nuts of approved size for HT 11000 volts complete all as specified and directed by Engineer-in-Charge.
S&F in replacement of Cross arms, bracings, supports, clamps and back plates fabricated from structural steel sections conforming to Fe-410-S grade including necessary nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape and size as directed and including applying two coats of aluminium paint (under & finishing coats) over a coat of red oxide zinc chromate primer on exposed steel surfaces, supplied and fixed in repairs, complete all as specified and as directed by Engineer-in-Charge.
Dismantling of existing PCC/steel HT pole of any description complete all as directed and specified .
S & Fixing Pressed concrete pole 11 mtr long 152mmX152 mm at top and 152mm X260 mm at bottom Class 9 complete all as specified and as directed by Engineer-in-Charge. Make:-M/S Cementfabri india/M/S Hindustan prestressed concrete /M/S Indian PCC pole/M/S concrete udyig .
Supply and erecting Steel tubular swaged poles complete with MS base plate, finial taper plug, as specified type 410 SP-55(11.00 mtr long) including painting of complete pole 9m long with 2 coats of aluminium anti corrosive paints of first quality over a coat of red oxide primer including painting to pole upto 1.5m height from top of PCC coping with synthetic enamel paint 2 coat in black and white alternate strip including numbering in 8 cm height of number with white paint both paint aluminium/synthetic duly approved by Engineer in Charge complete all as specified and directed by Engineer-in-charge. Make:-India tube and co/Bombay tubes/National tubing Co kanpur/India electric poles and co Maharastra.
Taking out the sample of transformer oil from bottom of each transformer and HT OCB installed at various locations for checking die elecric strength & acidity test of oil and carrying out dehydration (Filtration) of cooling/ insulating oil of HT/LT transformers and HT switch gears through straight line oil filtration plant for removing carbon deposit, extracting moisture content etc. After filtration, the oil shall withstand die electric strength 60 KV within 1 minute with 4 mm Gap . Die elecric strength & acidity to be tested before and after filtration and submit the test results all as specified. Note:- (i). Rate deemed to be inclusive of topping up of oil for transformers/ switch gears. (ii). Oil for topping up will be measured and paid seperately under item No-42 here-in-after.
Supply only insulating /cooling Transformer oil EHV type conforming to IS 3357 of 1983 suitable for 11 KV transformers / switch gear etc having die electric strength of more than 60 KV for filling / topping up.complete all as directed by Engineer in charge
Taking down existing unserviceable silica jel from breather of transformer and supply and fill new Jel.complete all as directed by Engineer in charge
Taking down existing unserviceable breather of transformer and supply and fix New PCC best quality transparet type breather assembly with silica gel complete.
Disconnecting HT/LT connection of transformer and opening up the top cover of transformer of capacity up to 500 KVA for checking the conditions to carryout repairs at site, including draining out oil from the transformer in suitable container (containers to be provided by the contractor) and repair to the transformer with replacement of parts (as required), checking the lead connection from winding to bus rods including necessary soldering/jointing etc and after complete repair refilling the dehydrated oil,replacing perished gasket with new gasket of same size and testing on full load after connecting the HT/LT connections complete all as directed by Engineer in charge (Notes :(i) Labour component required for the repalcement of unserviceable parts shall be deemed to be included in the unit rate quoted against this item (ii) Major parts (as required) shall be measured and paid separately under appropriate item of this Sch ‘A’ (iii) Dehydration/filtration of transformer oil shall be measured and paid separately under appropriate item of this Sch ‘A’ (iv) T&P and minor parts will be arranged by the contractor and the cost thereof shall be deemed to be included in the unit rate quoted against this item) Note: Rate deemed to be inclusive of securing the cables on HT/LT side for tension free at cable entry box.
Material and Labour for preparation of old painted surfaces of indoor/outdoor type transformers upto 500 KVA capacity at various substations for painting and applying one coat of spray paint with synthetic enamel paint of approved tint without distributing/damaging the electrical network system /equipment including marking of ratings/incoming/outgoing details/SM Nos in capital English alphabet of sizes all as directed. Note:- 1. Rate deemed to be inclusive of securing the cables on HT/LT side for tension free at cable inletbox and improving the IR values of HT/LT side winding, if values are not permisible limits.
Dis connecting the HT 11 KV VCB/SF6 panel capacity ranging from 630/400 Amp, Over hauling of complete panel by taking out the trolley of the breaker, opening the total mechanism of breaker checking its contact, baffle plates and other minor parts, cleaning the complier accessories carefully. Minot repairs shall be rectified Parts/accessories shall be cleaned properly and refixing the parts at its original locations, checking and repair of the internal panel wiring with suitable size of wire and remove the carbon deposited inside the contract, cleaning the tank, baffle plates, rotating contact, upper supports, lower supports, drive assemblies, Testing of primary injection and secondary injection of CT and PT's by authorised company rep and replacing all other spare parts all as directed by the Engineer-in-charge and reassembled after repair/replacement of following parts. Note: Spare parts as required for replacement of existing worm out parts shall be measured and paid separately under appropriate items Nos a to here-in-after as supply only of make Crompton greaves and seimen.
Decarbonsing/cleaning complete HT panels board, 11 KV cubicle type, consists of bus bar chamber, circuit chamber and metering chambers, by opening the spout/bus covers inspecting the bus bar joints, cleaning of bus bars, checking the bus bar spouts and circuit spouts for any flash overs/tracks, applying Becktolred solution to the bus bars and spouts having moderate tracking, replacement of bus bar/circuit spouts in case of spouts subjects to heave tracking, applying HT insulated red compounds/Monoplist compound at the bus bard joints after tightening of joints, cleaning of bus bar insulators and bus bars with CTC and ensure proper decarbonisation and re-assembling complete all as directed by Engineer-in-Charge.Make : Crompton Greaves/GEC/ALSTOM
Disconnecting and taking out the IDMT relay three-element type CDG61/CDG31 of EE make/JM 10 of Essunreroll/ICM 21P of ABB make(Two numbers of current and one number earth fault element)from HT 11 KV panel,cleaning the contacts. Calibrating the relay by conduting primary injection and seondary injection tests,checking of current transformer, rectifiation of defects in control wiring for proper tripping of circuit brakers through CTs and relays and tripping coils.adjustment/setting to plug and time multiplier settings of the relay to achieve the discrimination in tripping time of upstream brakers,re-installation of the relay in circuit complete all as specified and as directed. NOTE:- The contractor shall provide necessary testing kits, testisng equipments,tools etc and shall also prepare the detailed test reports panel wise duly bounded and submit to the department. Rate for the kits and equipment is deemed to beincluded in rate quoted. Testing and turning shall be carried out in the prsence of Engineer-in-Charge to the satisfaction of department failing payment for the above item will not be made to the contractor. No claim from the contractor be enterained on this account.
Supply only Trip catch assy.
Supply only Big gear assy.
Supply only Small gear.
Supply only Tripping coil 30 V DC
Supply only Closing coil 30 V DC
Supply only Trip Shaft
Supply only Closing shaft
Supply only Holding Latch assy.
Supply only Power Pack 110 V input and 24 V DC.
Supply only spring charging motor 220 V AC/DC Supply.
Supply only Roller Bearing
Supply only isolating contacts suitable for 11 KV VCB, 630 Amps rating same to match with existing complete all as directed by Engineer-in-charge.
Supply and fixing in replacement HT 11KV Vacuum interrupted assembly with flex connection suitable for VMX type VCB 630 Amps capacity for RYB phases complete all as specified and directed by Engineer-in-Charge.
Supplying, installing, testing, calibrating and commissioning of the IDMT relays with instant tripping system, working voltage 110 V, EF 10% to 40% IN 50% to 200% in advance including taking out the existing unserviceable IDMT relay (CG114N/CG114S) complete all as directed by Engineer-in-Charge.
Supply and fixing in replacement potential transformer 11 KV/110/100VA burden with draw able type and epoxy including PT grid with risers complete suitable for HT 11 KV panel complete including tasting and commissioning all as specified and directed by Engineer-in-Charge.
Supply and fixing in replacement current transformer 11 KV, epoxy cast wound, CT of ratio 100/50/5A class-I including necessary connection etc. including testing and commissioning complete all as directed by Engineer-in-charge.
Dismanting crefully userviceable HV bushing with metal assembly from transforme upto 500 KVA capacity with taking HT shutdown supply and fix HV bushing with metal assembly complete all as directed.
Dismanting crefully userviceable LV bushing with metal assembly from transforme upto 500 KVA capacity supply and fix LV bushing with metal assembly complete all as directed.
Servicing of LT ACB's of capacity upto 1250A drawn out carefully cleaning the moving contact unit springs with CTC check the operating system etc complete all as directed.
Servicing and aluminium painting two coat after rubbing/rusting of cross arms and channel at the hight of 11 mtr 2/4 pole structure including tightening and fitting of necessary nut and bolt competed all as directed.
Earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below normal ground level) with top edge of the plate not less than 1.5 mtr below normal ground level surrounded from all sides by 15 cm thick packed layer of charcoal dust and common salt filling in alternate layers and electrode connections by mean of GI strip32 x6 mm by means of bolts, nuts check nuts and washers of GI or steel and connecting to earthing test point, main switch board, testing on completion including PCC cover and frame, PCC (1:3:6) type C-2 as in earthing pit, MS funnel with wire mesh GI pipe 200 mm dia medium grade for watering and GI pipe 50 mm dia light grade for the protection of GI strip from earth pit to earth point complete including necessary excavation and earth work in any type of soil, returning, filling in approved soil and disposal of surplus soil to a distance n.exc 50 m all as specified as shown in electrical plate No 5 SSR Part-I. PCC chamber shall be constructed at least one metre away from the earth pit and GI pipe fittings for watering shall be provided up to chamber and cost of the same is deemed to be included in the rate of earthing. Note : The quoted rate is deemed to be included for GI strip 32X6 mm along with strip protection pipe 50 mm dia upto 7.5 mtr and taking down old earthing complete, making good with adjacent areas complete all as specified and directed by Engineer-in-charge.
Material and labour for earthing complete with Copper earth plate electrode 600 X 600 X 3,15 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5M below normal ground level connected to copper earth strip 20 x 3 mm thick by means of with brazing at joints and connecting to testing point including provision of test point, test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm and all as shown in electrical plate No. 3 of SSR Pt I. The work is inclusive of necessary earth work and PCC chamber in type CI (1:2:4) with 8 CTD bar reinforcement both ways at 140 mm centre to centre complete all as directed . Note : The quoted rate is deemed to be included for copper earth strip 20X3 mm along wtih strip protection pipe 40 mm dia upto 7.5 mtr and taking down old earthing complete, making good with adjacent areas complete all as specified and directed by Engineer-in-charge.
Surface dressing in hard / dense soil not eceeding 15 cm deep and clearing all the grass weeds etc in the sub station yard after removing stone aggregate aside all as directed at site including setting / sepreding back the aggregate complete all as directed at site Note: All the sub station shall be kept clean throughout the contract period by repeatedly removing the grass/weeds Once a Three Months minimum as applicable as per site conditions depending on the growth of the grass.complete all as directed.
Supply and fixing in replacement indicator lamp in diffrent colour code LED/Neon type complete (RYB) suitable for HT VCB 630/400 Amp including wiring with copper conductor cable of suitable size complete all as specified and as directed by Engineer-in-charge. Make:-L&T/Siemens/C&S.
Supplying and laying in replacement Rubber mat of 1 mtr x 2 mtr x 19 mm at sub station complete all as directed by Engineer-in-charge.
S & F in replacement PG clamp For ACSR Panther conductor complete all as specified and as directed by Engineer-in-Charge.
S&F in replacement High voltage HRC link fuse 40A,11000V, fuses (as per samble kept at AGE E/M office) complete as specified and as directed by the Engineer-in-Charge.
S&F in replacement Cable route indicators (HT) made out of cast iron,and supported with angle iron of 60 Cm long, size 50mmX50mmX5mm including PCC 1:3:6 (20mm graded aggregate) .cable route indicator angle will be embedded with PCC not less than size 15cm x 15cm x 30cm in ground including earh work and all as specified and as directed by the Engineer-in-Charge.
SREE VARU ELECTRICALS
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .