Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.8 LAccepted-AOC HOUSE NO 29 A SIJUBARI NIZARA PATH PO PS HATTIGAON GUWAHATI 38 | KAMRUP METRO | ASSAM | 781038 | L1 | Accepted-AOC L1 bidder | |
| 2 | L2₹23.1 L+₹27,915 (1.23%)Rejected-Finance C O MR M K BHOWMIK NEAR TAPAN VARIETIES JOYNAGAR 06 AGARTALA TRIPURA W 799001 | WEST TRIPURA | TRIPURA | 799001 | L2 | Rejected-Finance Quoted rate higher than L1 bidder | |
| 3 | Rejected-Technical | - | Rejected-Technical NIT criteria not fulfilled | |
| 4 | Rejected-Technical | - | Rejected-Technical NIT criteria not fulfilled | |
| 5 | Rejected-Technical | - | Rejected-Technical NIT criteria not fulfilled |
Tender Value
₹27.5 L
EMD Value
₹55,000
Closing Date
27 Feb 2021, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE
HQ 137 Wks Engrs PIN 914137 Co 99 APO
SPECIAL REPAIR AND REPLACEMENT OF REFRIGERATOR WATER COOLER AIR CONDITIONER EXHAUST FAN AND GEYSERS AGAINST BER AT MIL STN AGARTALA
2021_MES_417309_1
8521/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
Agartala
Class D
Category c i
2 documents required · 2 mandatory
₹500
AGE(I) Agartala
₹55,000
31 Mar 2021
29 Jan 2021
1 Mar 2021
29 Jan 2021
27 Feb 2021
12 Feb 2021
60 days
Amount
Supply installation testing and commissioning refrigerator electric driven single phase (240 Volt AC) of capacity minimum 310 litre/ nearest higher volume with double door frost free with copper condencer and copper pipe and latest minimum 4 star rating available at market as per BEE complete all as specifed and as directed. Note: No price adjustment will be considered in case of higher volume provided.
Supply, install testing and commissioning of water cooler electric driven single phase (240 Volt AC) with stainless steel body and brass chromium plated faucets outlet having water inlet hose pipe and overflow pipe with cooling capacity at rated conditions- 40Ltr/hr and storage capacity- 80Ltr complete all as specifed and as directed.
Supply, Installation, testing and commissioning of wall mounted air cooled split type Air Conditioner with indoor and out door unit, electric driven single phase (240 Volt AC) of cooling capacity 1.5 Ton, copper condencer and copper pipe with cordless remote control unit with latest 3 star rating available at market as per BEE including all accessories like bracket, water pipe and tested on full load upto the level of satisfaction of Engr -in charge complete all as specifed and as directed.
Supply, installation, testing and commissioning of Electric storage water heater (rust and shock proof body) with attractive looks and corrosion resistance inner tank having capacity 25 ltr, 5 star rated with multi function safety valve,heating element, indicating lamps etc all as per following specifications : (a) Power/ input : 8.7 Amp, 230 volt, 50 Hz (b) Rated power input In KW : 2 KW (c) Max rated pressure : 8 bar (0.8 MPa) (d) Storage capacity : 25 Ltr (e) Installation type : Wall mounted(vertical) (f) Mean hot water output - 75°C (g) Mixing factor- 30% Maximum (h) Water proof degree- IP X 4 (j) Class of appliance- Class I (k) Heating element : Incoloy glass coated heating element, superior heating performance with excellent resistance to both oxidation and carbonization at high temperature setting . Resists corrosion against extreme and hard water conditions with minimum energy loss. (l) Inner container : It shall be Feroglas coating, made of ultra thick super cold rolled steel plates with superior corrosion resistance and ‘anti-rust property’. (m) Anode rod: The tank has an anode rod with a stainless steel core. (n) Insulation: CFC free thicker PUF insulation. (o) Star rating : 5 star from BEE complete all as specified and as directed.
NOTE FOR SERIAL ITEM NO 1.00 TO 4.00 A Board Of Officer shall be appointed by the Accepting Officer to check the specifications of all the items as per latest IE rule and BEE specification. The Board Of Officer will also ascertain/ match the quantity of items declared BER with the quantity of items being provided in the contract.
Supply and fixing for 300mm sweep size ventilating fan with louvers, AC, Single phase 230/240 volts 1400 RPM after and including cutting/making opening of walls and making good the disturbed surfaces as per the existing internally and externally complete all as specified and as directed by the Engr-in-Charge.
SHRI SUBRATA GUHA
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .