Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹6.1 Cr
EMD Value
₹12.1 L
Closing Date
25 Nov 2026, 3:00 pm2d left
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Deposit Work
Above/Below/Par
EL
4 conditions · 4 needing a document upload
The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V= Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover.The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender.
Definition of Similar nature of work: - Design, Supply, Erection Testing & Commissioning of 25kV / 2 * 25kV AC, 50 Hz, Single phase, OHE system.
ELECTRICAL CONTRACTOR LICENSE- (i)The Contractor should have valid A-Class Electrical license to be submitted along with tender failing which tender would be consider ineligible (i.e. not eligible). (ii)The work shall be carried out by the contractor, having valid Electrical Contractor's License for carrying out installation work under the direct supervision of the persons holding valid certificates of competency issued by the State Government. (iii)The successful tenderer shall furnish the names and particulars of the certificate of competency of supervisor and workmen to be engaged for carrying out this work.
18 conditions · 15 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Tender Document Para 1.8 of Part III page no. 13 & 197, Tender form (Annexure No. I)
Tender Document Para 2.14 of Part-III page no.16 & 200, Format for certificate to be submitted / uploaded by tenderer along with the tender documents (Annexure -V)
Tender Document Para 5 of Part-III page no. 20 & 204, Bid security in accordance with Para 5 with Part -III of Preamble and General Instructions to Tenderers. (Bid security) bank guarantee bond from any scheduled commercial bank of India. (Annexure - VIA)
Tender Document Para 10.2 of Part III Page no. 24 & page no. 206, Annual contractual turnover data for the previous 3/4 years (Annexure-VIB) along with copies of Audited Balance Sheets
Tender Document Para 10.1 of Part III page no. 23 & 236, Technical eligibility criteria details (Form No.-2A) (Please attach the complete BOQ, Purchase Order/LOA, and Work Completion Certificate for verification and evaluation of the submitted credentials/similar nature of work.)
Tender Document Page No. 238, Applicant's party information form (Form No.-2C)
Tender Document Page No. 239, ECS/ NEFT / RTGS mandate form (Form No.-3)
Tender Document Page No. 241, Pre contract integrity pact (Form No.-5)
Tender Document Page No. 247, Anti-profiteering declaration to whomsoever it may concern (Form No.-6)
Tender Document Para- 4 Part-III page no. 19, Certificate for provision for medium & small enterprises (MSE) (If applicable)
Tender Document Para-14 of Part-III page No. 27, The tenderer shall clearly specify whether the tender is submitted on his own (Proprietary Firm) or on behalf of a Partnership Firm / Company / Joint Venture (JV) / Registered Society / Registered Trust / Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc.
Tender Document Para 10.1 (c) of Part-III page no. 24, Electrical Contractor License
Tender Document Page No. 4, Scanned copy of proof of money deposited against Earnest money.
Tender Document Page No. 4, Scanned copy of proof of money deposited against Tender Document Cost.
Tender Document Page 224, List of plants & machinery available on hand and proposed to be inducted (own and hired to be given separately) for subject work. (ANNEXURE-XVIII)
Tender Document Page 225,List of engineers / personnel already available / proposed to be employed for deployment on this work (ANNEXURE-XIX)
GST Registration Certificate
OHE Work in connection with CONCOR siding between AELN and REJN Station of DFCCIL Jaipur Unit.
DFCC-JP-EL-REJN-KSGN-T-43~WDFC
DFCC-JP-EL-REJN-KSGN-T-43
Open
Works - General
6 Months
Jaipur, Rajasthan
₹11,800
₹12.1 L
22 Oct 2026
22 Oct 2026
11 Nov 2026
60 days
232 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 6,00,74,134.36 | ||
| — | 7.00 | — | — | ||
| Preparation of design and drawing for overhead equipment and verification of purchaser Modification plan | — | — | — | 1,33,830.76 | |
| — | 725.00 | — | — | ||
| Excavation for Structure- Excavation in all types of soils and soft/hard rock, concrete/masonry drains/walls | — | — | — | 1,74,935.25 | |
| — | 655.00 | — | — | ||
| Foundation work: Providing and laying of concrete for foundation and plinth in all types of soils using M-15 grade concrete for main foundation and M-20 grade concrete for grouting and muffing including nominal reinforcement wherever required as per RDSO drawings including muffing: M-15 (Foundation) | — | — | — | 57,03,995.45 | |
| — | 70.00 | — | — | ||
| M-20 (Grouting) | — | — | — | 8,11,307 | |
| — | 20.00 | — | — | ||
| Providing and fixing Centering and Shuttering including oil for casting concrete including frame work wherever necessary. | — | — | — | 24,105.6 | |
| — | 142.00 | — | — | ||
| Supply of rolled or Fabricated and galvanized Traction Mast, TTC, Portals, AT Mast, Dwarf Mast etc. | — | — | — | 2,07,80,416.32 | |
| — | 142.00 | — | — | ||
| Erection of rolled or Fabricated and galvanized Traction Mast, TTC, Portals, AT Mast, Dwarf Mast etc. | — | — | — | 15,38,868.2 | |
| — | 16.00 | — | — | ||
| Supply of Fabricated and galvanized SPS other than Mast | — | — | — | 23,60,985.28 | |
| — | 16.00 | — | — | ||
| Erection of Fabricated and galvanized SPS other than Mast | — | — | — | 1,68,841.92 | |
| — | 202.00 | — | — | ||
| Supply of Single Bracket assembly | — | — | — | 47,18,972.5 | |
| — | 202.00 | — | — | ||
| Erection of Single Bracket assembly | — | — | — | 4,57,754.22 | |
| — | 202.00 | — | — | ||
| Supply of Stay and Bracket Tube composite Insulator set CD-1600 mm | — | — | — | 10,68,721.4 | |
| — | 202.00 | — | — | ||
| Erection of Stay and Bracket Tube composite Insulator set CD-1600 mm | — | — | — | 3,01,826.38 | |
| — | 6.80 | — | — | ||
| Supply of OHE with complete fitting without contact and catenary wire | — | — | — | 2,71,093.9 | |
| — | 7.00 | — | — | ||
| Erection of OHE with complete fitting without contact and catenary wire | — | — | — | 2,69,890.39 | |
| — | 25.00 | — | — | ||
| Supply of Copper jumper wire | — | — | — | 2,12,575.5 | |
| — | 25.00 | — | — | ||
| Erection of Copper jumper wire | — | — | — | 21,236.75 | |
| — | 35.00 | — | — | ||
| Supply of Guy Rod Assembly | — | — | — | 3,98,398.7 | |
| — | 35.00 | — | — | ||
| Erection of Guy Rod Assembly | — | — | — | 52,185.7 | |
| — | 45.00 | — | — | ||
| Supply of 09 ton Insulators ( CD-1600) | — | — | — | 1,19,046.6 | |
| — | 45.00 | — | — | ||
| Erection of 09 ton Insulators ( CD-1600) | — | — | — | 22,372.2 | |
| — | 16.00 | — | — | ||
| Supply of 3 Pulley ATD with Counterweight Assembly. | — | — | — | 13,05,416.32 | |
| — | 16.00 | — | — | ||
| Erection of 3 Pulley ATD with Counterweight Assembly. | — | — | — | 86,813.76 | |
| — | 160.00 | — | — | ||
| Supply of Retro reflective type Number plate as per DFCCIL requirement including all fixing arrangement | — | — | — | 1,44,121.6 | |
| — | 160.00 | — | — | ||
| Erection of Retro reflective type Number plate as per DFCCIL requirement including all fixing arrangement | — | — | — | 14,412.8 | |
| — | 2.00 | — | — | ||
| Supply of Light Weight Section Insulator Assembly as DFCCIL requirement | — | — | — | 8,85,178.44 | |
| — | 2.00 | — | — | ||
| Erection of Light Weight Section Insulator Assembly as DFCCIL requirement | — | — | — | 10,097.8 | |
| — | 160.00 | — | — | ||
| Supply of structure Bond including Rail clamp | — | — | — | 1,50,459.2 | |
| — | 160.00 | — | — | ||
| Erection of structure Bond including Rail clamp | — | — | — | 36,694.4 | |
| — | 5.57 | — | — | ||
| Supply of Catenary wire of 65 sq. mm/125 Sq. mm as per DFCCIL requirement. | — | — | — | 69,59,399.57 | |
| — | 7.60 | — | — | ||
| Supply of Contact Wire of 107 sq. mm as per DFCCIL requirement | — | — | — | 94,95,769.61 | |
| — | 2.00 | — | — | ||
| Supply of 65 sq. mm Catenary wire Splice | — | — | — | 2,317.78 | |
| — | 2.00 | — | — | ||
| Erection of 65 sq. mm Catenary wire Splice | — | — | — | 231.76 | |
| — | 16.00 | — | — | ||
| Dismantling of Bracket Assembly | — | — | — | 30,174.4 | |
| — | 5.00 | — | — | ||
| Cutting and Removal of Existing structure | — | — | — | 6,903.1 | |
| — | 2.00 | — | — | ||
| Dismantling of Guy rod assembly | — | — | — | 1,909.34 | |
| — | 3.00 | — | — | ||
| Dismantling of Fabricated steel other than mast | — | — | — | 50,884.56 | |
| — | 0.50 | — | — | ||
| Dismantling of OHE /Feeder wire | — | — | — | 12,117.39 | |
| — | 2.00 | — | — | ||
| Dismantling of Copper Jumper | — | — | — | 1,721.62 | |
| — | 20.00 | — | — | ||
| Dismantling of 09 Ton Insulators | — | — | — | 19,343.4 | |
| — | 10.00 | — | — | ||
| Handling Loading unloading and /transportation of DFC supply /released OHE material such as Mast, Wires, Fittings SPS etc. From IMD/ISMD to Site & released material from site to IMD/ISMD | — | — | — | 48,862.5 | |
| — | 10.00 | — | — | ||
| Supply of Material without Insulators for termination of OHE Conductor | — | — | — | 50,367.2 | |
| — | 10.00 | — | — | ||
| Erection of Material without Insulators for termination of OHE Conductor | — | — | — | 8,192 | |
| — | 1.00 | — | — | ||
| Supply without insulator 25 KV 1600 Amp Single pole isolator ( manually operated) with earth contact assembly | — | — | — | 49,746.74 | |
| — | 1.00 | — | — | ||
| Erection of 25 KV 1600 Amp Single pole isolator ( manually operated) with/without contact assemblyEach | — | — | — | 3,952.64 | |
| — | 4.00 | — | — | ||
| Supply of 25 kV/ 66 kV Post/Pedestal Insulator for Isolator | — | — | — | 32,809.04 | |
| — | 4.00 | — | — | ||
| Erection of 25 kV/ 66 kV Post/Pedestal Insulator for Isolator | — | — | — | 1,554.48 | |
| — | 10.00 | — | — | ||
| Supply of solid Copper Bus bar 18 mm | — | — | — | 14,894.9 | |
| — | 10.00 | — | — | ||
| Erection of solid Copper Bus bar 18 mm | — | — | — | 1,306.4 | |
| — | 1.00 | — | — | ||
| Supply and erection of 25 kV Post and operating rod insulator | — | — | — | 19,900.52 | |
| — | 1.00 | — | — | ||
| Supply of large copper jumper wire (160 sq mm) between copper bus bar and OHE, cross feeder to OHE etc. with associate fittings | — | — | — | 3,693.11 | |
| — | 1.00 | — | — | ||
| Erection of large copper jumper wire (160 sq mm) between copper bus bar and OHE, cross feeder to OHE etc. with associate fittings | — | — | — | 224.48 | |
| — | 10.00 | — | — | ||
| Preparation of computerized OHE layout plan (LOP) of station Yards | — | — | — | 58,739.8 | |
| — | 36.00 | — | — | ||
| Fabrication, developing and supply of fabricated sectioning diagram Schematic and TSWR diagram boards adhesive venyle of adequate size as per requirement and correction in SWR as required. | — | — | — | 73,360.44 | |
| — | 36.00 | — | — | ||
| Modification in already developed sectioning diagram, Schematic and TSWR diagram boards in different sizes with computerized digital printing on adhesive venyle of adequate size as per requirement | — | — | — | 21,200.04 | |
| — | 5.00 | — | — | ||
| Supply and erection of "Caution clearance to OHE nearby restricted" Board size 450x270x2mm with supply of fixing material (Clamp, back flat strip & fasteners) | — | — | — | 8,079.55 | |
| — | 12.00 | — | — | ||
| Supply and erection of "Power Block Working Limit" Board size 450x450x2 mm with supply of fixing material (Clamp, back flat strip & fasteners) | — | — | — | 19,196.64 | |
| — | 6.00 | — | — | ||
| Supply and erection of "Electric Engine Stop" Board size 900x600x2mm with supply of fixing material (Clamp, back flat strip & fasteners) | — | — | — | 27,606.3 | |
| — | 2.00 | — | — | ||
| Supply and erection of "Caution unwire turnout" Board size 900x600x2mm with supply of fixing material (Clamp, back flat strip & fasteners) | — | — | — | 6,026.18 | |
| — | 2.00 | — | — | ||
| Supply and erection of "Caution live wire" Board size 400x270x2mm with supply of fixing material (Clamp, back flat strip & fasteners) | — | — | — | 6,383.56 | |
| — | 5.00 | — | — | ||
| Supply of various types of 25 KV Danger Boards / plates as per explanatory notes | — | — | — | 2,711.9 | |
| — | 5.00 | — | — | ||
| Erection of various types of 25KV Danger Boards / plates as per explanatory notes | — | — | — | 345.2 | |
| — | 8.00 | — | — | ||
| Design, manufacturing, supply of Retro Reflective type Sigma Board with non- reflective black ground as per RDSO drg. No. TI/Drg/OHE/PLTBRD/RDSO /00036/12/0 1125 (Size 450 mm x 600 mm) and RDSO specification No. ETI/OHE/33A (12/97) Rev. 8 or latest including transportation and all taxes etc. | — | — | — | 14,978.24 | |
| — | 4.00 | — | — | ||
| Supply of Solid Copper Bus bar connector: Bus Terminal | — | — | — | 12,818.72 | |
| — | 4.00 | — | — | ||
| Erection of Solid Copper Bus bar connector :Bus Terminal | — | — | — | 190.68 | |
| — | 1.00 | — | — | ||
| Supply of Solid Copper Bus bar connector: Bus Splice | — | — | — | 3,487.2 | |
| — | 1.00 | — | — | ||
| Erection of Solid Copper Bus bar connector :Bus Splice | — | — | — | 49.2 | |
| — | 0.50 | — | — | ||
| Erection of 288 Sq. mm AAAC Feeder wire with all fittings as required | — | — | — | 17,600.2 | |
| — | 8.00 | — | — | ||
| Supply of feeder Suspension Clamp Make Arruti | — | — | — | 86,552.72 | |
| — | 2.00 | — | — | ||
| Supply of Feeder termination Clamp Make Arruti | — | — | — | 26,090.24 | |
| — | 18.00 | — | — | ||
| Supply of 120 sq. mm Jumper wire | — | — | — | 32,506.02 | |
| — | 175.00 | — | — | ||
| Supply of 10 Sq. mm Current Carrying Dropper wire flexible | — | — | — | 94,990 | |
| — | 112.00 | — | — | ||
| Supply of 10 Sq. mm Current Carrying Dropper Fitting | — | — | — | 2,58,372.8 | |
| Each Span | 16.00 | — | — | ||
| Erection of material for new Dropper and readjustment of dropper | — | — | — | 6,961.12 | |
| — | 1.00 | — | — | ||
| Dismantling of ATD fittings | — | — | — | 3,289.34 | |
| — | 16.00 | — | — | ||
| Transfer of OHE from one support to another support | — | — | — | 82,516.16 | |
| — | 2.00 | — | — | ||
| Supply of AEW OHE termination Fitting | — | — | — | 10,584.6 | |
| — | 2.00 | — | — | ||
| Erection of AEW OHE termination Fitting | — | — | — | 529.24 | |
| — | 1.00 | — | — | ||
| Supply of 5 Pulley ATD with Counterweight Assembly. | — | — | — | 1,18,451.47 | |
| — | 1.00 | — | — | ||
| Erection of 5 Pulley ATD with Counterweight Assembly. | — | — | — | 4,666.2 | |
| — | 4.00 | — | — | ||
| Erection of Anticreep | — | — | — | 15,019.72 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TenderDocumentT-43.pdf
ATTACHMENT
NIT-T-43Signed.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .