Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.4 LAccepted-AOC JYOTI BAKERY 1ST FLOOR A5 HSEDRI G RZA 5 PALAM NEW DELHI SOUTH WEST DELHI DELHI 110045 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110045 | L1 | Accepted-AOC Being L1 Bidder | |
| 2 | L2₹32.6 L+₹2.2 L (7.30%)Rejected-AOC RZ 18 260 WEST SAGARPUR NEAR MCD SCHOOL NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | L2 | Rejected-AOC Not L1 Bidder | |
| 3 | L3₹33.1 L+₹2.7 L (8.74%)Rejected-AOC | L3 | Rejected-AOC Not L1 Bidder | |
| 4 | L4₹33.5 L+₹3.1 L (10.1%)Rejected-AOC BUILDING NO FLAT NO 19 6TH CROSS ROAD SANJEEVINI NAGAR MUDALAPALYA BANGALORE 560072 | BANGALORE | BANGALORE | KARNATAKA | 560072 | L4 | Rejected-AOC Not L1 Bidder | |
| 5 | L5₹34.0 L+₹3.6 L (11.9%)Rejected-AOC E 73 FF GALI NO 17B SADH NAGAR PALAM COLONY NEW DELHI 110045 | SOUTH WEST DELHI | DELHI | 110045 | L5 | Rejected-AOC Not L1 Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
15 Nov 2024, 6:00 pmClosed
GE U WATER SUPPLY DELHI CANTT 10
GE U WATER SUPPLY DELHI CANTT 10
PETTY REPAIRS FOR ATTENDING DAY TO DAY EM EXTERNAL WATER SUPPLY COMPLAINT AT PARADE CAMP AREA MALL ROAD POLO ROAD CHURCH ROAD STATIION ROAD URBAN VILLAGE MANEKSHAW MARG OLD NEW APS COLONY SANJAY VIHAR IN THE AREA OF AGE U WS II UNDER GE U WATER SUPPL
2024_MES_679907_1
GE/WS/Token-25 OF 2024-25
Open Tender
Civil Works
Item Rate
330 days
GE U WATER SUPPLY DELHI CANTT 10
Please refer Tender documents.
5 documents required · 5 mandatory
₹500
GE U WATER SUPPLY DELHI CANTT 10
₹90,000
Yes
30 Dec 2024
17 Oct 2024
18 Nov 2024
17 Oct 2024
15 Nov 2024
1 Nov 2024
Amount
Providing a team of labour & plumber with helper for attending day to day external water supply complaints of all nature i.e. leakage in water supply pipe lines, fittings/fixtures, over flow of overhead tank, no water supply including noting the complaints in complaint register including Sunday and Holidays complete all as specified and as directed.
Providing a team of labour and electrician with helper only for attending day to day Complaints for internal / external electric supply of pump houses (including Sunday & Holidays) maintenance of existing LT panels including connecting electrical accessories/spares of water supply installations, electric fittings with lights, short circuits in pump house including noting the complaints in complaint register complete all as specified and as directed.. Note for srl No 1 & 2 :- Material required for attending complaints shall be measured & paid separately under respectvie items here-in-after.
Notes for Srl No. 1 & 2 :- The rates quoted by the contractor shall also deemed to be included for the following :- (i) The complaints shall be attended and the defects shall be rectified by a team of One Experienced Electrician and One Experienced Plumber assisted with two helper, matriculation passed qualified having minimum 03 years experience . (ii) The complaints shall be attended & defect shall be rectified within 08 hrs commencing from date and time of notifying the complaint failing which a penalty @ Rs 500/- per complaint per day (08 hrs) shall be levied upon/imposed on the contractor and recovery shall be made from Contractor's dues. (iii) In case , after checking & attending the defect,if it is not possible to rectify the defect within 08 hrs, the facts shall be brought to the notice of Engineer-in-charge by the contractor/his rep. If Engineer-in- charge is satisfied with contractor's view, no recovery will be made.
(iv) While attending the complaint of water supply/Electric supply if earth work is required then the same shall be measured and paid seperately under appropriate item of Sch 'A'/BOQ. However no extra payments shall be made for dewatering. (v) Cutting of GI pipe in position and threading is also deemed to be included in the job quoted rates (Fittings and fixtures shall be measured and paid separetely under respective items of Sch A/BOQ). (vi) All T&P required for attending the complaints shall be provided by the contractor without any extra. (vii) The pipe fitter shall always be in possession of die set complete with cutters,Taps, Pipe wrench ,Chain wrench, Caulking tools, complete set of spanners and ladders etc..,as required at site. (viii) The electrician shall always be in possession of all electrician tools, LT megger, Earth tester, multimeter, crimping tool, insulation tape, hand gloves etc. as required at site. (ix) Rate for taking down/out existing & fittings & fixtures and refixing to make it functional shall be into account. (X) Material used complaint wise (docket wise) and it will be paid under supply only item rates vide BOQ ser item No 3.01 to 17, 26 and serl item No 28.01 to 30.04 as mentioned below.
(xi) A BOO ordered for material procured by contractor and taken on charge through RV and complaint wise dockets will maintained and USR's duly vetted by AO GE (E/M) for procured materials issued for incorporation in work will be mentioned in BOO. BOO will concorn / approved by Accepting Officer in one time for complete materials to be consumed in work and if any balance quantity of material left with contractor the same will received back on credit USR's & kept on record. (xii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of iron scrap in weight (KG) shall be taken into account and attach with RAR/F Bill)
Supply only GI Socket, medium grade, ISI Marked of make as mentioned in "list of make/ manufacturer's" complete all as specified and as directed of following :-
GI Socket 15 mm bore
GI Socket 20 mm bore
GI Socket 25 mm bore
GI Socket 40 mm bore
GI Socket 50 mm bore
Supply only GI Elbow, medium grade, ISI Marked of make as mentioned in "list of make/ manufacturer's" complete all as specified and as directed of following sizes:-
GI Elbow 15 mm bore
GI Elbow 20 mm bore
GI Elbow 25 mm bore
GI Elbow 40 mm bore
GI Elbow 50 mm bore
Supply only GI Union, medium grade, ISI Marked of make as mentioned in "list of make/ manufacturer's" complete all as specified and as directed of following sizes:-
GI Union 15 mm bore
GI Union 20 mm bore
GI Union 25 mm bore
GI Union 40 mm bore
GI Union 50 mm bore
Supply only GI Nipple of different length as per requirement, both end screwed medium grade, ISI Marked of make as mentioned in "list of make/ manufacturer's" complete all as specified and as directed of following sizes:-
GI Nipple 15 mm bore
GI Nipple 20 mm bore
GI Nipple 25 mm bore
GI Nipple 40 mm bore
GI Nipple 50 mm bore
Supply only GI reducing socket, medium grade, ISI Marked of make as mentioned in "list of make/ manufacturer's" complete all as specified and as directed of following sizes:-
GI reducing socket size 20 x15 mm bore
GI reducing socket size 25 x15 mm bore
GI reducing socket size 25 x20 mm bore
GI reducing socket size 25 x32 mm bore
GI reducing socket size 40 x32 mm bore
GI reducing socket size 50 x40 mm bore
GI reducing socket size 40 x20 mm bore
GI reducing socket size 40 x25 mm bore
GI reducing socket size 50 x25 mm bore
Supply only GI solid plug, heavy duty of make as mentioned in "list of make/ manufacturer's" complete all as specified and as directed of following sizes:-
GI plug, 15 mm bore
GI plug, 20 mm bore
GI plug, 25 mm bore
GI plug, 32 mm bore
GI plug, 40 mm bore
GI plug, 50 mm bore
Supply only GI Tee, Medium Grade of make as mentioned in "list of make/ manufacturer's" complete all as specified and as directed of following sizes:-
GI Tee of size 15 x 15 x 15 mm
GI Tee of size 20 x 20 x 15 mm
GI Tee of size 20 x 20 x 20 mm
GI Tee of size 25 x 25 x 25 mm
GI Tee of size 25 x 25 x 15 mm
GI Tee of size 25 x 25 x 20 mm
GI Tee of size 32 x 32 x 32 mm
GI Tee of size 40 x 40 x 40 mm
GI Tee of size 40 x 40 x 20 mm
GI Tee of size 40 x 40 x 25 mm
GI Tee of size 50 x 50 x 50 mm
GI Tee of size 50 x 50 x 40 mm
GI Tee of size 50 x 50 x 25 mm
GI Tee of size 50 x 50 x 20 mm
Supply only PTMT float valve, Sizes as under, with epoxy coated aluminium rod and high density plastic ball of make as mentioned in "list of make/ manufacturer's" complete all as specified and as directed:-
PTMT float valve, 15 mm bore
PTMT float valve, 20 mm bore
PTMT float valve, 25 mm bore
PTMT float valve, 40 mm bore
PTMT float valve, 50 mm bore
Supply only Gun metal gate valve of make as mentioned in "list of make/ manufacturer's" with iron wheel head screwed both ends for iron pipe as per IS-778 and fixed complete all as specified and as directed of following sizes:-
Gun metal gate valve, 15 mm bore
Gun metal gate valve, 20 mm bore
Gun metal gate valve, 25 mm bore
Gun metal gate valve, 40 mm bore
Gun metal gate valve, 50 mm bore
Supply only PTMT stop cock of weight not less than 75 gram each complete all as specified and as directed of following sizes:-
15mm dia
20mm dia
25mm dia
Supply only Tank nipple of required length complete all as specified and as directed of following sizes:-
20mm dia
25mm dia
Supply only lead pig bar best quality in pack complete all as specified and as directed.
Supply only Spurn Yarn best quality in roll complete all as specified and as directed.
Supply only 25 to 150 mm long, 6 to 20 mm dia nuts, bolts & washers complete all as specified and as directed.
Supply only 3mm thick rubber gasket complete all as specified and as directed.
Supply and fixing of rotational moulded polyethylene water storage tank , cylindrical vertical with closed top, 500 ltrs capacity, triple layered hoisted and fixed in position alongwith lid cover after taking down as existing at site (of any capacity) and removing to store yard at his own arrangement complete all as specified and as directed.
Supply and fixing of rotational moulded polyethylene water storage tank , cylindrical vertical with closed top, 1000 ltrs capacity, triple layered hoisted and fixed in position alongwith lid cover after taking down as existing at site (of any capacity) and removing to store yard at his own arrangement complete all as specified and as directed. (Note for Item No 18 & 19: (i) For Pump Priming purpose in pump house. (ii) Old U/s material PVC tank obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of PVC scrap in weight (KG) shall be taken into account and attach with RAR/F Bill. (iii) Tank shall be provided on PCC (1:2:4) type B-I using 20mm graded crushed stone aggregate ramp of 150mm thick round shape over roof slab or in ground floor over sub base of PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate and top surface of ramp finished even and smooth using extra cement complete the cost of ramp will be deemed included in quoted unit rate.)
M&L for testing of drinking water being collected from local source (bore wells/shallow wells/under ground sumps) one test in 15 days (monthly 1 (One) test of each source) in the area under AGE(U) W/S No II and submission of detailed test report to the office of Engineer-in-Charge. (a) Collection of water from different sources of water ie Sump, bore wells & shallow wells in sterilized bottle and testing in Govt Approved laboratory as mentioned in specification. (b) Carrying out minimum essential testing of water as per IS 10500-1991 mandatory for chemical colour, odour, taste, turbidity, Lead, PH value TDS total hardness, iron, chloride, fluride and residual free chlorine and Bacteriological total Collie from organisms per 100 ml (MPN) and E Collie in 100 ml) and submission to this office with specific recommendation regarding suitability of water for drinking purpose.
Note :- Rate quoted shall deemed to be included for : - (i) Cost of sterilized bottle as required. (ii) To and fro transportation charges for collection of samples from source(sump/bore well/shallow wells) (iii) Contractor will required to visit the site of AGE (U) W/S-II area for working out number of sources i.e borewells/shallow wells/under ground sumps etc. However approximate tests of sources are 18 (Eighteen) numbers for different source. (iv) Period of testing of water sources is of 11 (Eleven) months from the commencement of work. (v) "Test report" will be accepted from NABL lab directly received by post to concern Eng-in-Charge from Lab under intimation to GE.
Excvation in trenches not exc. 1.5 mtr wide and not exc 1.5 mtr deep for pipe line in soft/loose soil, getting out and levelling of bottom surface as required complete all as specified and as directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers not exc 25 cm thick complete all as specified and as directed.
Removing excavated material to a distance not exc 50 m and depositing where directed not exc 1.5 meters above the starting point complete all as specified and as directed.
M&L Boring holes under road pavement by bocky manually/mechanically in any type of soil upto 200 mm bore complete all as specified and directed by Engineer-in-Charge. (Note:-Location & depth of boring holes is as directed by EIC)
Surface dressing of uneven surfaces of the natural ground, rough excavated surfaces and filled area where ordered shall be trimed to an even surface horizontal or slopping, by removing vegetation and by scrapping high patches and filling low patches with the scrapping soil to given an even and neat look to the site. depth of cutting not exceeding 15 cm complete all as specified and directed by Engineer-in-Charge.
Supply only 15 mm bore Bib tap of PTMT not less than 75 gram in weight any tint, high pressure screwed for male/ female threaded, for pipe of size 15 mm bore complete all as specified and as directed.
Labour work required for taking out suction pipe from sump of any capacity 80 mm to 200 mm size screw / flanged type and relowering after refixing in position the same duly cleaned / minor repair if any required such as replacement of rubber gasket / lifting bolts & nuts including making thread for the suction pipes off sizes etc complete all as specified and directed by Engineer - in - charge
Supply only 'stem' made out from SS (all as per sample) of sluice valve of size as under : -
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply only 'stem nut' made out from stainless steel suitable to match with existing sluice valve of sizes as under : -
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply only 'gland plate' made out CI, suitable to match with existing sluice valve of sizes as under : -
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Taking up or down old GI steel tubing of following sizes with connections from Trenches/floors/walls including cleaning for refixing or removal complete all as specified and as directed:- Note :- (i) Excavation & earth work shall be measured & paid separetely. (ii) Quantity obtained after taking down servicable tubing shall be refixed at site and balance unserviceable tubing shall be taken on charge and recorded in RV.
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Relaying/refixing only jointing and testing of old GI pipes with new socket / fittings including cleaning completely in trenches/walls/floors as directed for the following sizes :-
15 mm dia
20 mm dia
25 mm dia
40 mm dia
50 mm dia
80 mm dia
Supply & Laying of GI pipe medium grade ISI mark including all fittings in old/new positions in trenches/wall/floor complete and making good the distributed surfaces as per existing as directed of following sizes:- (Note:- (i) Excavation and earth work will be measured and paid separately. (ii) Old U/s material GI pipe obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill)
15 mm bore
20 mm bore
25 mm bore
40 mm bore
50 mm bore
80 mm bore
Supply & fixing in replacement of cast iron/ DI fitting for flanged /spigot and socketed pipes such as bends, reducer, tee pieces, tail pieces, collar, cross, caps & plug upto 150mm bore complete all as specified and directed. (Note:- Old U/s DI fitting obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV weight in (KG) shall be taken into account and attach with RAR/F Bill).
Supply & fixing in replacement of CI fittings/specials such as Tees, bends (any type, radius and angle) tapers any type, collars, tail pieces, caps and plugs of upto 150 mm bore dia size confirming to IS: 1538-1993 complete all as specified and directed by Engr-in-Charge. (Note:- Old U/s CI fitting obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV weight in (KG) shall be taken into account and attach with RAR/F Bill).
Taking up Cast Iron/ Ductile Iron/Cement/PVC water mains of following bore including all fittings with spigot & socket ends of lead joints including burning out lead joints and recovering lead complete all as specified and as directed. (Note :- (i) Excavation & earth work for new location shall be measured & paid separetely. (ii) Old U/s CI/DI/Cement/PVC pipe obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in (RM) & lead in (KG) shall be taken into account and attach with RAR/F Bill).
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Relaying/refixing of pipe CI/DI/PVC pipes after cleaning from inside with suitable chemical and rodding all as directed by Engineer -in-charge of following sizes :- (Note:- Excavation and earthwork shall be measured and paid seperately unde respective items).
80 mm bore
100 mm bore
150 mm bore
200 mm bore
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Material and labour including jointing and testing of cast iron sluice valves class PN-1.0, conforming to IS:14846 flanged ends drilled having stainless steel spindle with cast iron wheel at top complete with nuts, bolts, washers and rubber gaskets including taking out unserviceable sluice valve and removal from site for the follwing sizes complete all as specified and directed:- (Note:- Old U/s sluice valve material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in numbers (EACH) shall be taken into account and attach with RAR/F Bill.)
80 mm bore
100 mm bore
150 mm bore
200 mm bore
250 mm bore
300 mm bore
M&L of PCC (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation of brick pillar to support the pipe line including demolition of old PCC and removing the debris from site complete all as specified and as directed at site by the Engr-in-Charge.
M&L of Brick work with sub class 'B' bricks straight or curved on plan exc. 6M mean radius built in CM (1:4) as in brick pillar of required size and shape to support the pipe line including demolition of old brickwork & removing from site complete all as specified and as directed at site by the Engr-in-Charge. (Note:- Old U/s brick / brick bats obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Old U/s brick/brick bats if any shall be removed from site at location where directed by EIC of contractors own arrangement.)
Supply and filling Multipurpose Grease lubricant for Motors & Pumps complete all as specified and as directed at site by the Engr-in-Charge. (Note:- Lubricant shall be provided in sealed container only.)
Supply, fixing, jointing & testing butterfly valve (wafer type) of sizes as under, ISI Marked, flanged ends drilled pressure rating PN-1.0, PD Short body, inserting new one complete all as specified and as directed at site by the Engr-in-Charge. (Note:- Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in numbers (EACH) shall be taken into account and attach with RAR/F Bill.)
100 mm bore
150 mm bore
200 mm bore
Supply, installation and testing flanged ends strainer/dirt box rating (PN 1.0) of following sizes with stainless steel mesh suitable for cold water meter to avoid foreign material entering into meter and making good connection with flanged ends, with gasket rubber sheet and nut & bolts fixing in horizontal/inclind/ vertical position, including taking out unsv strainer/dirt box complete all as directed at site by the Engr-in-Charge. Note :- (i) Flange joints including jointing materials shall deemed to be included in the unit rate of this item. (ii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of strainer/dirt box in weight (KG) shall be taken into account and attach with RAR/F Bill)
80 mm bore
100 mm bore
150 mm bore
Supply, installation and testing of flanged ends Water Meter woltman type, including testing and making good connection with flanged ends, with gasket rubber sheet and nut & bolts etc ISI Marked fixing in horizontal/incline/vertical position, including taking out unserviceable water meter of following sizes complete all as specified and as directed at site by the Engineer-in-Charge. (Note:- (i) Flange Joints Including Jointing material shall deemed to be included in the unit rate of this item. (ii) Old U/s water meter obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV of water meter in number (EACH) shall be taken into account and attach with RAR/F Bill)
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supply and fixing CI foot valve flanged ends, swing type opration with rubber sheet, as per IS:4038 including taking out unsv foot valve all as specified and directed by Engr-in-Charge. (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item (ii) Old unserviceable foot valve shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
80 mm bore
100 mm bore
150 mm bore
Supply, fixing, jointing and testing of Cast iron Non Return valve without by pass arrangement, swing type, confirming to IS 5312, flanged ends pressure rating PN 1.0 complete including taking out unsv NRVcomplete all as specified and as directed at site by the Engr-in-Charge. (Note:- (i) Flanged joints complete with jointing material shall deemed to be included in the unit rate of this item. (ii) Old unserviceable NRV shall be taken on charge and enter in demolition / salvage register in 'EACH' and attach the same page of salvage register with each RAR.)
80 mm bore
100 mm bore
150 mm bore
200 mm bore
Supplying, laying, jointing, welding and testing MS Pipe (Heavy class 'C') IS : 1239/3589, of followiing sizes laid in trenches or in Horizontal/Vertical/inclined position or laying on floors for connections for suction, to header and connected to out going water main CI/DI pipe line, for following size including taking out the old unserviceable pipes :- (Note:- (i) MS Flanges incl fabrication work will be measured and paid separately. (ii) Excavation and earth work will be measured and paid separately. (iii) Old U/s material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill.)
80 mm dia
100 mm dia
150 mm dia
200 mm dia
250 mm dia
M&L for 15mm thick cement plaster on fair faces of brick work or concrete surfaces in cement plaster 1:4 including taking down of existing plaster complete all as specified and direceted.
Supply & fixing of UPVC pipes of pressure rating of 10Kg/CM square fixed complete to walls, ceiling, floor or in trenches any types of pipe including fittings & jointing to the existing of following sizes. (Note:- Old U/s PVC scrap material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill.)
75/80 mm dia
100/110 mm dia
150/160 mm dia
Supply & fixing of Brass QCV(Quick coupling valve)/QRC(quick release valve) of size 1-1/4" complete all as specified and as directed
Supply & fixing of Gear driven pop up sprinkler (full/part), 1'' inlet, capable dia 28 mtr to 50 mtr 2.8-6.9 bars with a discharge rate of 25.4 - 116 lpm complete all as specified and as directed. (Note for ser item No 51 & 52 :- Old U/s PVC scrap material obtained from demolition shall be taken on charge in demolition/salvage register and enter page number in demolition statement. Necessary RV in weight (KG) shall be taken into account and attach with RAR/F Bill.)
P S TRADERS (BID ID -3166457)
ENVIRO TECH SERVICES (BID ID -3159990)
Rahul Enterprises (BID ID -3159810)
PRASAD ELECTRICALS (BID ID -3164227)
M P TYAGI ENGINEERS AND CONTRACTORS (BID ID -3158425)
M/s Sree Baba Traders (BID ID -3166221)
B.R. Enterprises (BID ID -3166362)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .