| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹10.4 LAccepted-AOC NAMBLABAL PAMPORE DISTRICT PULWAMA JAMMU KASHMIR 192121 | PAMPORE | PULWAMA | JAMMU KASHMIR | 192121 | L1 | Accepted-AOC L1 | |
| 2 | L2₹10.6 L+₹19,065 (1.84%)Rejected-Finance | L2 | Rejected-Finance Other than L1 | |
| 3 | L3₹11.7 L+₹1.4 L (13.2%)Rejected-Finance | L3 | Rejected-Finance Other than L1 | |
| 4 | L4₹12.0 L+₹1.6 L (15.8%)Rejected-Finance | L4 | Rejected-Finance Other than L1 | |
| 5 | L5₹13.4 L+₹3.0 L (28.9%)Rejected-Finance | L5 | Rejected-Finance Other than L1 |
Tender Value
₹24.2 L
EMD Value
₹48,380
Closing Date
11 Dec 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE, HQ 134 Works Engineers
HQ 134 Works Engineers PIN - 914134 C/o 56 APO
REPAIR AND MAINT OF DG SETS, AMF PANELS, LT SERVO STABILIZER, AIR HEATING AND HOT WATER PLANTS AND CONNECTED WORKS AT HAFT CHINAR MIL STN UNDER GE 970 EWS
2024_MES_683647_1
134WE-64(T)/2024-25
Open Tender
Civil Works - Others
Item Rate
180 days
GE 970 EWS
As per tender documents
9 documents required · 9 mandatory
₹500
GE 970 EWS
₹48,380
Yes
13 Jan 2025
13 Nov 2024
13 Dec 2024
13 Nov 2024
11 Dec 2024
28 Nov 2024
14 Nov 2024 - 20 Nov 2024
Amount
All as per item No. 1 above but for 10KVA to 32.5KVA capacity. Note:- (Item 01 to 03) (i) Worn out parts required to be replaced will be measured and paid for separately. (ii) Dismantling as per site requirement for repair and any minor parts required for making the DG Set fully operational not mentioned in subsequent items is deemed to be included in rates quoted. SM/MES No : 02H/6054/DG/03, 02H/6030/-DG/03, 02H/6026-DG/01, 02H/6052/DG/03, 02H/6001-DG/03, 02H/6050/DG/03, 02H/6048/DG/03, 02H/6028-DG/03, 02H/6029-DG/03 , 02H/6045-DG/06 (Haft Chinar)
Supply only in replacement cylinder liner with liner ring for DG set of 62.5 KVA, complete all as specified and directed.
All as per item No. 3 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
Supply only in replacement piston ring set for DG set of 62.5 KVA capacity, complete all as specified and directed.
All as per item No. 5 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
Supply only in replacement gasket set with ‘O’ ring set for 62.5 KVA capacity of DG Set, complete all as specified and directed.
All as per item No. 7 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
Supply only in replacement inlet/exhaust valve pair for 62.5 KVA capacity of DG Set, complete all as specified and directed.
All as per item No. 9 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
Supply only in replacement main bearing set for DG Set of 62.5 KVA capacity, complete all as specified and directed.
All as per item No. 11 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
Supply only in replacement main oil seal (Rear & Front) for DG Set of 62.5 KVA capacity, complete all as specified and directed.
All as per item No. 13 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
Supply and fixing in replacement flexible coupling for DG set of 62.5 KVA capacity, complete all as specified and directed.
All as per item No. 15 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
Supply and fixing in replacement lub oil filter for DG Set of 62.5 KVA capacity, complete all as specified and directed.
All as per item No. 17 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
Supply and fixing in replacement fuel filter for DG Set of 62.5 KVA capacity, complete all as specified and directed.
All as per item No. 19 above but 32.5 KVA/ 25 KVA/20 KVA/10 KVA capacity, complete all as specified and directed.
Supply and fixing in replacement fan belt for DG Set of 62.5 KVA capacity, complete all as specified and directed.
All as per item No. 21 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
Supply only crank shaft as required 62.5 KVA DG set of any make and model including testing, complete all as specified and directed.
All as per item No. 23 above but 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
Supply only cam shaft as required 62.5 KVA DG set of any make and model including testing, complete all as specified and directed.
Supply only connector rod as required 62.5 KVA DG set of any make and model complete all as specified and directed, complete all as specified and directed.
All as per item No.26 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
Supply only in replacement head gasket with ‘O’ ring for 62.5 KVA capacity of DG Set, complete all as specified and directed.
All as per item No. 28 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
Supply only in replacement began for 62.5 KVA capacity of DG Set, complete all as specified and directed.
All as per item No. 30 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
Supply only in replacement main began for 62.5 KVA capacity of DG Set, complete all as specified and directed.
All as per item No. 31 above but for 10 KVA to 32.5 KVA capacity, complete all as specified and directed.
Extracting burnt /unserviceable valve seats 62.5 KVA DG set and re-fixings after cutting grinding and polishing as per new valves including head facing and transporting to and from work shop, complete all as specified and directed.
All as per srl item No 34 above but capacity 10 KVA to 32.5 KVA DG Set, complete all as specified and directed.
Dismantling and taking down unserviceable fuel injector pump transporting to work shop for the following repairs DG sets transporting back to site re-fixing and testing after completion, complete, all as specified and directed.
Calibration and complete repair of fuel injector pump of DG set 62.5 KVA (Pressure type) on work bench pressure supply of fuel as per standard procedure and testing, complete all as specified and directed.
All as per srl item No 37 here-in-before, but capacity 10KVA to 32.5 KVA DG Set, complete all as specified and directed.
Dismantling and taking down unserviceable fuel injector nozzle transporting to work shop for repairs transporting back to site re-fixing and testing after completion, complete all as specified and directed.
Overhauling and testing of injector nozzle on test bench for fine mist spray including replacement unserviceable parts for DG set of capacity 62.5 KVA, complete all as specified and directed.
All as item no. 40 here-in here-in-before but for 10 KVA to 32.5 KVA DG set, complete all as specified and directed.
Taking down turbo charger carefully dismantling and replacement of complete turbo charge and re-fixing to its original position complete all as specified and directed for upto 62.5 KVA DG set.
Taking down radiator complete from its mounting, dislodging top and bottom tank, eaning complete tube by descaling solution and finally re-installing in original position, complete, all as specified and directed for 10 KVA to 62.5 KVA.
Preparation and Painting of complete DG set including frame by two coats of enamelled paint as per colour code by spray painting and marking etc complete, all as specified and directed for 62.5 KVA.
Preparation and Painting of complete DG set including frame by two coats of enamelled paint as per colour code by spray painting and marking etc complete, all as specified and directed for 10 KVA to 32.5 KVA.
Dismantling alternator from the engine base for repairing including transporting to workshop, reinstalling, reconnecting with engine including testing on load for 10 KVA to 32.5 KVA DG set, complete all as specified and directed.
All as item no. 46 here-in here-in-before but for 62.5 KVA DG set.
Rewinding of armature with super enamelled copper of required size wire including varnishing, sleeves, cotton tape and heating etc. for DG Set of capacity 62.5 KVA , complete all as specified and directed.
All as per srl item No 48 here-in-before but for 10 KVA to 32.5 KVA DG set.
Dismantling, rewinding of field coils of alternator with super enamelled wire including varnishing and heating including reassembling and testing for capacity of DG Set 62.5 KVA, complete all as specified and directed.
All as item No 50 here-in-before, but for 10 KVA to 32.5 KVA DG set
Dismantling and taking down unserviceable self starter transporting to work shop for the repair and transporting back to site after complete repairs re-installation at site and testing after completion, complete all as specified and directed.
Repair to self starter including rewinding the coil winding, bearing pinion bush solenoid switch carbon brush and holder including transporting back to site, re-installing and testing complete all as specified and directed of 62.5 KVA capacity DG Set.
All as item No 53 here-in-before, but for 10 KVA to 32.5 KVA DG set.
Dismantling and taking out old dynamo and transporting to workshop for repair and transporting back to site after complete repair, reinstalling at site and testing complete all as specified and directed.
Repair to Dynamo of DG Set of capacity 62.5 KVA DG set including rewinding of coil, replacement of GM Bush, housing plate, cutout plate and transporting back to site, re-installation connecting and testing complete all as specified and directed. Note:- Any minor item required for complete repair is deemed to be inclusive in quoted rates.
All as item No 56 here-in-before, but for 10 KVA to 32 KVA DG set.
Supply and fixing in replacement 12 V self starter for 62.5 KVA DG set.
Supply and fixing in replacement 12 V self starter for 10 KVA to 32.5 KVA DG set.
Supply and fixing in replacement dynamo for 62.5 KVA DG set.
Supply and fixing in replacement dynamo for 10 KVA to 32.5 KVA DG set.
Supply and filling in replacement of engine oil including cleaning of engine oil chamber and replacement of gasket etc, complete, all as specified and directed.
Isolating, disconnecting and transporting the LT Servo voltage stabilizer of capacity 350 KVA workshop for repair, strip opening of stabilizer for inspection and accertaining the defects for repair & cleaning, servicing all serviceable acessories including reassembling after repair, preparation for and painting with two coats of synthetic enamel paint of approved colour and marking SM/MES No., transporting back to site, reinstallation and testing on load complete all as specified and directed. (Note:- Parts required for replacement will measured and paid seperately under respective items.)
Replacement of digital voltmeter 0 to 500 volts 96x96mm flush type incl taking out the old unserviceable, complete all as specified and directed.
Replacement of LT current transformer ratio as per existing rating in LT panels incl taking out the old unserviceable, complete all as specified and directed. Make:- L&T/AE.
Digital PCB Card/Plate for automatic voltage correction suitable for servo stabilizer of capacity upto 25 KVA as per site requirement for type and make, complete all as specified and directed.
All as per srl item No. 67 here-in-before, but of capacity 350 KVA DG Set.
Taking down old burnt winding and replacement of Booster coil 350 KVA -03 Nos Dimmer coil 350Ams -03 Nos, carbone brush 350 Ams-03 Nos, Digital micro processorcentral card, 10 Kg Togrg RC plate including leathriede paper cotton tape, winding varnishes etc for stabilizer oil immersed type of capacity of 350 KVA by using suitable gauge super enamelled copper conductor as per existing winding, complete all as specified and directed.
Supply of insulation transformer oil toping up into voltage stabilizer of different capacity complete with superior quality insulating oil BDV not less than 50 KV, complete all as specified and directed.
Dehydration of transformer oil uoto BDV not less than 50 KV, complete all as specified and directed.
Cast Iron dimmer gear set for automatic voltage correction capacity of 350 KVA with as per site requirement for type and make, complete all as specified and directed.
Micro limit switch with cam lever complete for servo stabilizer of capacity 350 KVA as per site requirement for type and make, complete all as specified and directed.
Replacement of indicator assembly LED type (RYB) in LT panel boards incl taking out the old unserviceable, complete all as specified and directed.
Replacement of servo motor synchronous type of torgue capacity 30 Kg for automatic voltage correction suitable for servo stabilizer of capacity of 350 KVA as per site requirement for type and make, complete all as specified and directed.
Servo Dimmer 200 Amps/ Booster83 KAA coil for automatic voltage correction suitable for servo stabilizer of capacity of 350 KVA as per site requirement for type and make, complete all as specified and directed.
Carbon brush with holder assembly for servo stabilizer of capacity of 350 KVA as per site requirement for type and make, complete all as specified and directed.
Replacement of digital Amp meter of existing range and size 96x96mm flush type in servo stabilizers incl taking out the old unserviceable, complete all as specified and directed.
Bush rod brass for servo stabilizer of capacity of 350 KVA as per site requirement for type and make, complete all as specified and directed.
Taking down old unserviceable control wiring and replacement of control wiring using suitable gauge super enamelled copper conductor as per existing winding for stabilizer transformer oil immersed type of capacity 350 kVA, complete all as specified and directed.
Replacement of over load relay for 350 KVA voltage stabilizer, complete all as specified and directed.
Replacement of graphite carbon bursh suitable for Servo voltage stabilizer of any capacity upto 350 KVA, complete all as specified and directed.
Replacement of Capacitor of capacity 1.42 to 4.0 MF + 5%, 440V, AC 50Hz, complete all as specified and directed.
Replacement of Pinion with gear (Medium) suitable for servo stablizer of any capacity, complete all as specified and directed.
Replacement of Pulsing Transformer heavy duty suiable for servo stablizer of any capacity, complete all as specified and directed.
Replacement of Control Transformer heavy duty suiable for servo stablizer of any capacity, complete all as specified and directed.
Earthing complete with galvanised steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level, connecting to the Galvanised iron earth lead 32x6mm size , by means of bolts, nuts, check nuts and washers of galvanised iron and 32x6mm earth lead protected by provision of GI medium grade pipe 40mm bore including porovision of concrete pit in PCC 1:2:4 type B-1 using 20mm graded crushed stone aggregates with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less thanb 4 Kg/Sqm) and frame of angle iron 25x25x3mm with lugs-02 Nos and with 6mm dia MS bar handle made to shape, GI medium grade 20mm bore pipe for watering perforated at bottom 1.50m long placed on top edge of earth plate, common salt and charcoal filling, test point with fixing arrangements, funnel, wire mesh and earth work in hard/dense soil, returning filling in and removal of surplys soil to a distance not exceeding 50m, all as per electrical plate No 3 of SSR-2009 Part-I and connection to earth test point all as specified and testing on completion. Note:- Item of Earthing includes cost of 7.5m long galvanised iron earth lead 32x6mm size and protection pipe of 40mm bore GI medium grade, complete all as specified and directed.
Off Load change over switch 63 Amps, 4 Pole made out of Sheet steel enclosure including replacement of incoming and outgoing lugs and fixing arrangement on panel/wall complete after taking down old one all as specified and directed. Make:- Havells/Standard/HPL/L&T.
All as per srl item No. 88 here-in-before, but of 32 Amps capacity. Make:- Havells/Standard/HPL/L&T.
Copper cable insulated unsheathed, multistranded of size 10 Sqmm three core, complete all as specified and directed. Make :- Havells or equivallent.
Supply and fixing of moulded case circuit breaker four pole 63 Amps 16 KA capacity 415V 50Hz incl taking out the old unserviceable, complete all as specified and directed.Haveels cat part No IHLGNF0063# or equivlent in L&T/Schinder/CG.
Supply and fixing of AVR suitable for DG set of capacity 10 KVA to 62.5 KVA.
Supply and fixing of Air filter suitable for DG set of capacity 10 KVA to 62.5 KVA.
Isolating, disconnecting and transporting the LT Servo voltage stabilizer of capacity 3 KVA to 5 KVA workshop for repair, strip opening of stabilizer for inspection and accertaining the defects for repair & cleaning, servicing all serviceable acessories including reassembling after repair, preparation for and painting with two coats of synthetic enamel paint of approved colour and marking SM/MES No., transporting back to site, reinstallation and testing on load complete all as specified and directed. (Note:- Parts required for replacement will measured and paid seperately under respective items.)
Isolating, disconnecting and transporting the LT Servo voltage stabilizer of capacity 10 KVA to 25 KVA workshop for repair, strip opening of stabilizer for inspection and accertaining the defects for repair & cleaning, servicing all serviceable acessories including reassembling after repair, preparation for and painting with two coats of synthetic enamel paint of approved colour and marking SM/MES No., transporting back to site, reinstallation and testing on load complete all as specified and directed. (Note:- Parts required for replacement will measured and paid seperately under respective items.)
Repair to unserviceable/burnt LT stabilizer of 3 KVA to 5 KVA capacity, rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnishing, reassembling, replacement of knobs, LED's etc. and making fully functional on load as connected to Refrigerator/Deep freezer/AC, complete all specified and directed by Engr- in-charge.
Repair to unserviceable/burnt LT stabilizer of 10 KVA to 25 KVA capacity, rewinding the same with super enamelled copper winding wire of suitable gauge including insulating material such as paper cotton sleeves, varnishing, reassembling, replacement of knobs, LED's etc. and making fully functional complete all specified and directed by Engr- in-charge.
Replacement of over load relay for 3 to 5 KVA voltage stabilizer, complete all as specified and directed.
Replacement of over load relay for 10 to 25 KVA voltage stabilizer, complete all as specified and directed.
Matarial and labour for Cleaning of plant and plant room, greasing, oiling of all parts of plants like pump, motor, switch, checking of nut bolt, serviceability of pump, motor, solenoid switch, duct, temperature gauge, timer, panels, blower, relay and all other parts of water heating plant of 200000 kcal per hr- 01 Nos; and rectify all minor maintenance work at site and report to deparment for major fault occurs in any part of plant Immediately on daily basis during running period of plant complete, complete all as specified and directed.
Dismantling the complete fuel injector pump of water heating plant, transporting to trade workshop for repairs and back, refixing the same after satisfactory repairs, re-installation and testing, complete all as specified and directed.
Material and labour for Calibration and complete repair of fuel injection pump of air heating plant on work bench for fine spray and machining work and refixing the same for satisfactory functioning, complete all as specified and directed.
Supply and fixing in replacement nozzle tip Water heating plant as per existing size and testing after repairs, complete, all as specified and directed.
Supply and fixing in replacement pressure meter water heating plant and central water air heating plant as per existing size and testing after repairs, complete, all as specified and directed.
Supply and fixing in replacement fuel filter suitable water heating plant as per existing size and testing after repairs, complete, all as specified and directed.
Supply and fixing in replacement heavy duty PVC fuel pipe of water heating plant as per existing size and testing after repairs, complete, all as specified and directed.
Supply and fixing in replacement burner gasket water heating generator as per existing size and testing after repairs, complete, all as specified and directed.
Taking out old UNSV and Supply, laying, jointing and testing of XLPE insulated, armoured, heavy duty LT under ground cable 1100 Volts grade with aluminium conductor laid in trenches, on poles, through pipes, fixed to walls etc cross sectional area for following sizes, including taking down old, complete, all as specified and directed :-
(a) 16 Sqmm 2 Core.
(b) 25 Sqmm 3.5 Core.
(c) 35 Sqmm 3.5 Core.
Excavation in trenches, not exc 1.5 mtr wide and not exc 1.5 mtr in depth for laying of XLPE cables, ducts, foundation etc. and getting out in soft/ loose soil, complete all as specified and directed.
Returning, filling in trenches including spreading, leveling and well ramming in layers not exc 25cm thick, complete all as specified and directed.
Removing excavated soil to a distance not exc 50 mtr and depositing where directed at a level not exc 1.5 mtr above the starting point, complete all as specified and directed.
M&L for dry river sand, laid in trenches for cable protection, as 15cm thick below the cable and 8cm thick above the cable, complete all as specified and directed. Note :- Punned thickness of sand shall be measured and paid.
M/L for brick well burnt locally available sub class 'B' laid over sand cushioning to cable in trenches keeping width of brick parallel to the length of cable, complete all as specified and directed.
Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp,
Supply and fixing LED flood light 100 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp, complete all as specified and directed.
Notes :- An amount of Rs. 69,674.00 on account of Credit Schedule for Schedule 'A' Part-II shall be deducted from total quoted amount of BOQ to arrive at the contract sum.
M/S Noor Mohammad Shalla (BID ID -3180318)
M/S M.Y Enterprises (BID ID -3180422)
M/s Nasir Rasool Dar (BID ID -3180852)
CHINAR CONSTRUCTION TRADERS (BID ID -3180707)
M/S BHAT ENGINEERING WORKS (BID ID -3179740)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .