| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹2.8 LAccepted-AOC | L1 | Accepted-AOC L1 |
Tender Value
₹2.9 L
EMD Value
₹6,150
Closing Date
21 Dec 2022, 9:30 amClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Ex. Engineer(Elect.)/CNZ
C-Block, Defence Colony, New Delhi-110024
Improvement of Lighting Arrangement at South Extension part 2 Market in Ward no. 60-S Under Central Zone.
2022_SDMC_138771_1
EE(Elect.)/CNZ/2022-23/80-01
Open Tender
Electrical Works
Item Rate
30 days
South Extn. Part-2
Please refer Tender documents.
2 documents required · 2 mandatory
₹500
₹6,150
29 Apr 2024
20 Dec 2022
21 Dec 2022
20 Dec 2022
21 Dec 2022
20 Dec 2022
Amount
Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required.
Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing as required.
Laying of one number PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. Up to 35 sqmm
Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size in the existingRCC/HUME/METAL pipe as required. Up to 35 sqmm
Supplying & drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/recessed steel/PVC conduit as required .(a) 3x2.5 sqmm
S/L of following size DWC HDPE Pipe ISI marked along with all accessories like socket ,bend ,couplers etc.conforming to IS 14930 ,part II complete with fitting and cutting ,jointing etc .direct in ground (75 cm below ground level )including excavation and refilling the trench but excluding sand cushioning and protective covering etc, complete as required (a)63mm dia (OD-63mm ID -51mm nominal ).
Supply of XLPE insulated, PVC sheathed Al. Conductor Armoured cable 1.1 KV grade confirming to IS-7098 of following Size (a) 2 X 6 Sq. mm
Providing and laying i/c HDPE pipe of 40 mm outer dia With PN rating 4 by hand molling/manual method conforming to IS 4984
Supply & erection of 3.5 meter length (above the ground level) M.S. decorative street light pole having two sections of M.S. Pipe. The inner dia. ,outer dia. & length of bottom section should be 132mmX139mmX1000mm (NS) respectively and of upper section should be 69mmX76mmX2490mm (NS). The pole should have a circular base plate of dia. 268mm and thichness 9.75mm and also an inbuilt junction box having opening & closing door i/c one no. 10 Amp MCB & neutral link at the bottom section. THe pole should be PU painted i/c 4 No. 10mm J type foundation bolt and .25cuM cement concrete (1:3:6) foundation etc as reqd.
SITC of 25W LED IP65 post top fitting made of diecast aluminium spigot spun aluminium powder coated top cover and clear acrylic diffuser with high voltage protection low power LED's conencted in series and parallel combination with better heat sink arrangement input voltage 160-260 volts AC, 50Hz AC Supply power factor >0.95 , luminious efficacy > 100 lumens /watt. CCT 5700°K ± 300°K, surge protection not less than 10KV complete etc as required.
Dismantling of pole/ street light standard/ strut embedded in cement concrete foundation etc. as required.
Providing and laying in position M25 grade reinforced cement concrete foundation of size 600 mm (L)x600 mm wide and 1200 deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 1160 mm long (approx)-8 nos . and reinforcement of cold twisted bars of 8 mm dia 1600 mm (approx) - 8 nos. (with 150 mm spacing) as required with supplying and positioning of 4 no. foundation bolts of size 20 mm dia ,750 mm long, J type i/c 2 nos. template anchor plates of size 225 mm X 225 mm X 3 mm and providing DCW, HDPE for cable entry and exit as required for 7m and 8 mtr pole.
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .