Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹38.6 LAccepted-AOC 2ND FLOOR A I ESTATE MOHAN NAGAR GAZIABAD 2023R10524 | L1 | Accepted-AOC accepted | |
| 2 | L2₹39.3 L+₹69,459 (1.80%)Rejected-AOC | L2 | Rejected-AOC rejected |
| Sl No | Description | Qty | Unit | Radiant Lights and Wires L1 | Green Energy Enterprises L2 |
|---|---|---|---|---|---|
| 1.00HSR Items | |||||
| 1.01 | [23.22.2.1]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 2.1. MCCB Enclosure made of Sheet Steel suitable for mounting MCCB of following ratings MCCB up to 125 A FP [Through Rate] | 4 | Each | 2,000 ₹8,000 | 1,800 ₹7,200 Lowest |
| 2.00 | [23.22.5.8]MCCB ,DISTRIBUTION BOARDS, MCB`s, RCCB`s, CHANGE OVER etc. 5.8. Supply and erection of miniature circuit Breaker 240/415 V in the existing distribution board including making necessary connections:- 40 amp to 63 amp. MCBs FOUR POLE [Through Rate] | 8 | Each | 1,500 ₹12,000 Lowest | 1,600 ₹12,800 |
| 3.00 | [32.70.2]Supply Installation testing commissioning of Solar Photovoltaic grid connected roof top Plant conforming to MNRE specifications as amended, consisting of Mono/Poly Crystalline silicon solar cells, net metering facility, necessary protections, earthing, mounted on Aluminium/GI structure of suitable strength with following components complete as required:-
(a) Solar Photovoltaic Module manufactured in India, conforming to IS 14286/IEC 61215, IS/IEC 61730-Part-1, IS/IEC 61730-Part-2. Solar Photovoltaic Module conversion efficiency shall not be less than 16.5%. PV modules used in solar power plants/ systems must be warranted for their output peak watt capacity, which should not be less than 90% at the end of 10 years and 80% at the end of 25 years.
(b) Power Conditioning Unit (PCU) of 350-800 V DC Input voltage range and 400 V AC, three phase, 4 wire, 50Hz plus /- 2.5 Hz, output voltage suitable to generate AC
(c) Power with efficiency not less than 97%, total harmonic distortion less than 3% and suitable for ambient temperature from 0 to 50 degrees C. The PCU shall adjust the voltage and frequency level to suit grid frequency
(d) Data Monitoring System complete with accessories.
(e) Fixing of Array junction box and Main junction box with IP 65 protection and termination arrangement for incoming and outgoing cable along with glands, lugs and other accessories etc. as required.
(f) Lightning and surge voltage protection.
(g) Connections and Interconnections by supplying and fixing required size XLPE insulated copper conductor 1.1 kV grade armoured power and control cables between solar modules, main power cable to grid supply PCU unit along with supplying and fixing of necessary channel/conduit lugs and other accessories etc. as required. 2. Above 10 kWp and up to 100 Kwp [Through Rate] | 19 | KWp | 43,000 ₹8,17,000 Lowest | 44,000 ₹8,36,000 |
| 4.00NS Items | |||||
| 4.01 | Supply and erection of Electric Heater with thermostat 3 KW complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. Make Green Energy/ Radiant/ Inter Solar | 16 | Each | 8,800 ₹1,40,800 Lowest | 9,000 ₹1,44,000 |
| 5.00 | Supply and erection of cold water storage tank of 1000LPD in Four layer with stand of MS in height 7.8ft. with (Civil work for Cold water Storage Tank and Hot water Pipe line and For Plant) complete with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works) Make :- Syntax/ Ganga/ Jindal. | 4 | Each | 32,000 ₹1,28,000 | 31,000 ₹1,24,000 Lowest |
| 6.00 | `S/I/T/C of solar water heating system of 1000 LPD capacity in FPC (Presser modal) with hot water storage tank made of ss 304L grade sheet, thickness 2.5mm with stand of C channel and piping GI duly insulated with rock wool 50mmand cladding as per MNRE guidelines and ISO Certified (SITC of Flat plate Solar collector panels of size 2000mm x 1000mm x 100mm (or as per manufacturer`s standard) with extruded Aluminum frame, glazing 3.2 mm thick toughened and textured glass back sheet of aluminum 25mm rockwool insulation at sides and 50mm rockwool/pufinulation at bottom of 48 kg/cum density and K value between 0.028 to 0.033 W/mK Absorber will be of Cu (copper) tubes type, of 2sqm area, Havin glaze /ultrasonic welded tube and fins arrangement, with Copper Tube Headers
of dia 25.4 mm (approx.) and 127 mm dia for riser tube with nos of riser tubes and absorber coating suitably selected Coating Absorptivity should be )90% and Coating Emissivity should be (20% with with brass flanges and EPDM rubber gaskets. The Collectors shall be placed with stands of size 32x 32 x 3mm thick Angles duly coated with included Civil work with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works). Make: Green Energy/ Radiant / Inter Solar` | 4 | P.Set | 5,45,000 ₹21,80,000 Lowest | 5,50,000 ₹22,00,000 |
| 7.00 | Supply and erection of 32mm GI pipe line B class for cold water. with all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. Make:- Jindal / Tata/ Parkash. | 35 | Each | 550 ₹19,250 Lowest | 555 ₹19,425 |
| 8.00 | Supply and erection of 25 mm dia GI Pipe B Class for hot water with 100mm Rockwood insulation with density 48kg/m3 complete all labour and material required to the complete in all respect up to entire satisfaction of the Engineer-in-Charge of the works. Make:- Jindal / Tata/ Parkash | 92 | P.Metre | 720 ₹66,240 Lowest | 777 ₹71,484 |
Tender Value
₹37.9 L
EMD Value
₹75,700
Closing Date
9 Sept 2025, 5:00 pmClosed
AMIT GOYAL
ED - Rohtak
Providing Solar Water Heating System and Solar Power Plant with allied material only
2025_HRY_469445_1
2025F79B49DE D91B 4876 B8F7 A49FCEDC24D1667BAR
Open Tender
Electrical Works
Works
180 days
Rohtak
Technical documents as per approved DNIT conditions.
3 documents required · 3 mandatory
₹5,000
₹75,700
Yes
28 Oct 2025
2 Sept 2025
10 Sept 2025
2 Sept 2025
9 Sept 2025
2 Sept 2025
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .