Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.9 CrAdmitted-Finance NO 6 173 2 EARIKARAI KALAPARAPATTY PO SALEM SOUTH TALUK VEMBADITHALAM VIA SALEM 637504 | SALEM | TAMIL NADU | 637504 | ₹1.9 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.1 Cr+₹11.7 L (6.02%)Admitted-Finance THIMIRIKOTTAI MECHERI SALEM DT | ₹2.1 Cr+₹11.7 L (6.02%) | L2 | Admitted-Finance |
| Sl No | Description | Qty | Unit | KGR&CO L2 | V P M PROJECTS L1 |
|---|---|---|---|---|---|
| 1.00Earth work excavation for foundation in all kinds of soils and sub soils to full depth as directed by the departmental officers except hard rock inclusive of shoring strutting and balling out water wherever necessary and refilling the sides of foundation with excavated earth in layers of 15cm thick well rammed and consolidated and depositing the surplus earth with in the compound in places shown by the departmental officers with initial lead of 10 meters and initial lift of 2 meters including cost of all labour charges etc., complete as per standard specification 23 & 24 VI (S2) VII.9,10 | |||||
| 1.10 | Footing | 220 | M3 | 180 ₹39,600 | 177 ₹38,940 Lowest |
| 1.20 | Plinth beam | 38 | M3 | 90 ₹3,420 | 89 ₹3,382 Lowest |
| 2.00 | Supply and filling of M-Sand of well gravel from approved quarry including cost and conveyance to work site and stacking the same to departmental gauge on road sides as directed by the departmental officers for pre-measurements etc., complete as per standard specification. | 18 | M3 | 1,700 ₹30,600 | 1,599 ₹28,782 Lowest |
| 3.00 | Collection and supply of well gravel from approved quarry including cost and conveyance to work site and stacking the same to departmental gauge on road sides as directed by the departmental officers for pre-measurements etc., complete as per standard specification. | 202 | M3 | 300 ₹60,600 | 283 ₹57,166 Lowest |
| 4.00 | Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below. Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers. | 275 | M2 | 130 ₹35,750 | 120 ₹33,000 Lowest |
| 5.00 | Plain Cement concrete 1 : 4 : 8 (one cement, four sand and eight aggregates) using 40mm ISS HBG metal including cost and conveyance of all materials and labour charges for mixing, laying, compacting and curing etc, complete as per SS | 48 | M3 | 5,000 ₹2,40,000 | 4,879 ₹2,34,192 Lowest |
| 6.00Supplying and Erecting Steel Centering for sides and soffits including supports and strutting upto 3.29 m height for plane surfaces such as RCC Slabs, Rectangular Beams, TEE or ELL Beams, Lintels, Bed blocks, Staircase waist and Landing slabs, Landing Beams, canopy etc., with all cross brasings using mild steel sheets of size 90cmx60cm and 10 gauge stiffened with welded MS angles of size 25mmx25mmx3mm for boarding laid over silver oak (CW) joists of size 10cmx6.5 cm spaced at about 90cm c/c and supported by causrina props of 10cm to 13cm dia spaced at 75cm c/c etc., complete complying with standard specification and as Directed . | |||||
| 6.10 | without strutting for footing | 174 | M2 | 300 ₹52,200 | 269 ₹46,806 Lowest |
| 6.20 | With Strutting for coulmn | 1,095 | M2 | 1,200 ₹13,14,000 | 1,082 ₹11,84,790 Lowest |
Tender Value
₹2 Cr
EMD Value
₹2 L
Closing Date
15 Nov 2022, 3:00 pmClosed
Commissioner
Commissioner, Municipal Office Edanganasalai
CONSTRUCTION OF ADDITIONAL OFFICE BUILDING EDANGANASALAI MUNICIPALITY
2022_MAWS_259400_1
95/2022/A1
Open Tender
Civil Works - Buildings
Item Rate
365 days
Work
Please refer Tender documents.
3 documents required · 3 mandatory
₹0
₹2 L
Yes
Municipal Office
21 Nov 2022
31 Oct 2022
16 Nov 2022
31 Oct 2022
15 Nov 2022
31 Oct 2022
4 Nov 2022
Amount
Earth work excavation for foundation in all kinds of soils and sub soils to full depth as directed by the departmental officers except hard rock inclusive of shoring strutting and balling out water wherever necessary and refilling the sides of foundation with excavated earth in layers of 15cm thick well rammed and consolidated and depositing the surplus earth with in the compound in places shown by the departmental officers with initial lead of 10 meters and initial lift of 2 meters including cost of all labour charges etc., complete as per standard specification 23 & 24 VI (S2) VII.9,10
Footing
Plinth beam
Supply and filling of M-Sand of well gravel from approved quarry including cost and conveyance to work site and stacking the same to departmental gauge on road sides as directed by the departmental officers for pre-measurements etc., complete as per standard specification.
Collection and supply of well gravel from approved quarry including cost and conveyance to work site and stacking the same to departmental gauge on road sides as directed by the departmental officers for pre-measurements etc., complete as per standard specification.
Providing Anti-termite treatment to soil adjecent and under building foundation, plinth periphery of the building by application of chemicals of IS 63613 part I to IV in stages to suit the progress of work consist as per the detailed specification as below. Including breaking of termite mounds, making holes with crow bar, closing the holes after the treatment and including cost of chemicals, labour charges, transport and storing etc., complete and as directed by the departmental officers.
Plain Cement concrete 1 : 4 : 8 (one cement, four sand and eight aggregates) using 40mm ISS HBG metal including cost and conveyance of all materials and labour charges for mixing, laying, compacting and curing etc, complete as per SS
Supplying and Erecting Steel Centering for sides and soffits including supports and strutting upto 3.29 m height for plane surfaces such as RCC Slabs, Rectangular Beams, TEE or ELL Beams, Lintels, Bed blocks, Staircase waist and Landing slabs, Landing Beams, canopy etc., with all cross brasings using mild steel sheets of size 90cmx60cm and 10 gauge stiffened with welded MS angles of size 25mmx25mmx3mm for boarding laid over silver oak (CW) joists of size 10cmx6.5 cm spaced at about 90cm c/c and supported by causrina props of 10cm to 13cm dia spaced at 75cm c/c etc., complete complying with standard specification and as Directed .
without strutting for footing
With Strutting for coulmn
Slab and beam
Providing and laying in position Standardised Concrete Mix M-20 Grade in accordance with IS 456 - 2000 using 20mm and down graded hard broken granite stone jelly for all RCC items of works with minimum cement contenet of 325Kg/ cum and maximum water cement ratio of 0.55 including admixture (Plasticiser / super plasticiser) in recommended proportions as per IS 9103 to accelerate, related setting of concrete, improve workability without imparing strength and durability with about (5.0cum), 7730Kg of 20mm machine crushed stone jelly and with about (3.3 cum), 5156kg of 10 - 12mm machine crushed stone jelly and with about (4.79cum) 7670 kg of sand, but excluding cost of reinforcement grill and fabricating charges centering and shuttering but including laying, vibrating with mechanical vibrators, finishing, curing, etc and providing fixtures like fan clamps in the RCC floor / roof slabs wherever necessary without claiming extra cost etc., complete complying with standard specification and as directed by the departmental officers - The Coarse and Fine aggregates to be used should comply with the requiremnents of IS staandards. (No separate payment will be made by the Department for the excess usage of materials) .
For Basement
For Ground floor
For First floor
For Second floor
Brick work in CM 1:5 (one cement & five sand) using II class ground moulded bricks of size 9"X43/8"X 2 3/4" including finishing, curing, etc., complete complying with standard specification - 100CFT
For Ground floor
For First floor
For Second floor
Suppling and fabricating and placing in position MS (or) R.T.S. bar for reinforcement to all RCC works as per the design given including cost of steel and binding wire also in all floors.
Plastering in cement mortar 1:5 mix 12mm thick using clean screened sand and including cost of curing for fifteen days from the completion of the work and surface should free from undulations and including the cost of preparing the surface for plastering and protecting for plastering for plastering and protecting from other damages till setting of mortar etc.complete complying with standard specification
Plastering in cement mortar 1:3 mix 10mm thick using clean screened sand and including cost of curing for fifteen days from the completion of the work and surface should free from undulations and including the cost of preparing the surface for plastering and protecting for plastering for plastering and protecting from other damages till setting of mortar etc.complete complying with standard specification
Painting two coats with ready mixed plastic emusion of first qulity paint and of approved colour over priming coat including through scrapping clean removal of dirt and , preparing the surface and curing etc., complete and including necessary plaster of paris ,Putty wherever required as per standard specification
Weathering Course with Concrete Broken Brick (S.I.No.278) & ( P & D) Data 54. Jelly 20mm gauge in pure slaked lime (no sand to be added) over roof slab,the proportion of brick jelly to lime being '32 to 12.5 well beated with wooden beaters for giving required slope and thickness as directed by the departmental officers.etc., complete.
Paving the floor with design Antiskirt ceramic tiles (colour and shade as directed) of size 305 mm x 305mm x 6 mm in all floors over a base layer of cement mortar 1:3 (one cement & Three P-sand) thick laid in-situ and pointed with same coloured cement mixed with colouring pigments (The crushed stone P-sand to be used in base mortar shell confom to gradation as per IS 1542-1977)
Paving the floor with Vitrified Marbonite tiles of approved quality and colour of size 600x600x8mm thick of approved make, quality and colour in all floors over a base layer of cement mortar 1:3(one cement three sand) 20mm thick and laid straight alignment and pointed neatly with colour cement at the rate of 0.40kg/m2 laid without any air gap in the tiles neatly and fixing in position as per standard specifications and as directed by the departmental officer. The colour & quality of tiles should be got approved by Municipal Engineer before use on work
Dadooing walls with Glazed tiles of sizes 305mm X200mm X 6mm size of approved make and quality and colour l Set in cement mortar 1:2 (one cement & Two P-sand) over 10 mm base layer plastering and pointing with white cement neatly as directed. (The crushed stone sand to be used in base mortar shell confom to gradation as per IS 1542-1977)
Finishing the top of the roof slab with one course of Machine pressed tiles of size 23cm x 23cm x 2 cm of approved quality laid in cementmortar 1:3 ( one cement and three sand) 12mm thick mixed with waterproofing compound 2 % by the weight of cement used and the top pointed with red oxide etc., complete complying with standardspecification
Supply and fixing of M.S Grills with Doors and Windows with one coat of Red oxide with Primer including all costs such as welding,grinding and fabrication charges, cost and conveyance of all materials to site etc,complete as per standard specification.
UPVC Ventilator Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Louvered Ventilators of from the profile the size of outer frame 60mm x 58mm and shutter profile size of 60 x 78mm both profiles are reinforced with GI/1mm 125GSM and 100% corrosion free, the profile are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with all over the edges of frame and shutter. The corners and joints should be welded and cleaned. Radiations pin headed glass 4mm thick should be provided in the louvers. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The ventilator should be got approved from the Executive Engineer before use on work
Providing UPVC (Un-Plasticized Polyvinyl Chloride) Door: Providing and fixing casement doors fabricated from un-plasticized polyvinyl chloride (uPVC) sections. Profiles: The profiles should be three chamber system which provides high insulation properties with outer frame 60mm x 55mm with an outer wall thickness of 2.4mm. The window unit should be designed with all corner joints mitred and fusion welded. Windows should be steel reinforced with 25 x 24 x 25mm steel reinforcement with a thickness of 1mm to have dimensional stability. The sash should be of 60 x 102mm. The mullion should be of 60 x 74mm. The profiles should have co-extruded seals.mHardware: All the hardware like friction stays, handles should be screwed with self tapping screws. The handles, locks should be designed so that they cannot be released from outside. Glazing: The window system should be glazed with 5mm plain float glass / 6mm bison lam Installation: The profiles should be cut to length and welded 45 degrees. The window should be designed such that the water drainage does not pass throughthe reinforcement chamber. The window system should be fixed directly to the plastered brick wall using self expanding nylon plug and driving ms electroplated screws into plug.
UPVC Window Specification: Supplying and fixing UPVC (Un-Plasticized Polyvinyl Chloride) Windows of casement type (open) from the profile the size of outer frame 60mm x 58mm and shutter profile are reinforcement with GI/1mm 125GSM and 100% corrosion free, the profiles are multi chambered sections with wall thick of 2mm. The EPDM rubber (black colour) covered with over all the edges of frame and shutter the shutter will be provided with Espag multi power point locks and also it operates as handle. The corners and joints should be welded and cleaned. Radiations free pin headed plain or brown colour glass 4mm thick should be provided to the shutter and it should not allow leakage of water even at most ranging storms and should have key lockable action, security protective hinges, strong locking systems and as per size for arresting noise and energy loss. The connecting mechanism between sash and outer frame that enables opening of the window. The window should be fixed to the wall with 100% packing with screws and silicon packing all round the frames. The window should be got approved from the Executive Engineer before use on work
Supplying and fixing in position White Glazed European Water Closet of best quality and approved make with 100mm 'P' os 'S'' trap with Double flapped rigit P.V.C. seat cover with C.P. brass hinges with 12.5 litres PVC Low Level Flushing Tank with all internal fittings etc., complete complying with standard spoecifications,labor inclusive of fixing lowlevel flushing tank.
Supplying and fixing in position best quality approved make white glazed earthenware wash hand basin of size 550 X 400 mm with a pair of cast iron brackets, including cost of 15mm diametre brass chromium plated piller tape,32 mm diametre C.P. Waste union, 32 mm diametre P.V.C. waste pipe with rubber plug and chain, 15mm diametre G.M.wheel valve, 15mm dia brass nipple, 15mm dia nylon connections etc., including fixing the wash hand basin in the wall in position with a pair of C.I. brackets with teak wood plugs and screws and giving necessary water supply connection and paintiung the brackets with two coats of paint over a primimg coat of anticorrosive paint including testing for leackage etc., complete complying with standard specifications
Wiring with 2 x 1.5 sqmm (22 / 0.3) PVC insulated SC unsheathed Cu. Conductor of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories in flush with wall with 3mm thick hylum sheet cover with TW switch box and 5A F.T switch with continuous earth wire connection of 14 SWG TC wire for making good of the concealed portion with suitable colour for PVC concealed light point / Fan point (For electronic regulator). SD - 23
Wiring with 2x1.5sqmm (22/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100 V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150mm x 100mm x 113mm TW switch box with 3 mm thick Hylem sheet cover for 5 A 3 pin non inter locking CS Plug with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour for concealed PVC plug point. SD - 38
Supply and run of 2 of 1.5 sq.mm. (22 / 0.3) PVC insulated SC unsheathed copper conductor of 1100V grade inmsuitable heavy gauge MS conduit pipe concealed in wall and ceiling with continuous earth wire connection of 14 SWG TC wire and making good of the concealed portion with suitable colour
Wiring with 2x4 sqmm(56/0.3) PVC insulated SC unsheathed Cu.Conductor cable of 1100V grade in suitable PVC rigid pipe concealed in wall and ceiling with PVC accessories, in flush with wall, with 150mm x 100mm x 113mm TW switch box with 3mm thick hylem sheet for 15 A 3 pin non inter locking CS plug with continuous earth wire connection of 14 SWG TC wire , and making good of the concealed portion, with suitable colour for concealed power plug point (SD-40)
Supply and fixing of 1400 mm sweep (56") AC ceiling fan complete with stepped electronic 300W regulator with 1metre down rod including fan clamp with side plates and cross arm of size 450 mm. SD - 108
Supply and fixing of single box type 440 W flu fitting complete with copper choke and condensor with TW round blocks on wall or ceiling with flu tube with PVC unsheathed Copper leads from terminals to the fitting. SD - 88
Supply and fixng of TNEB Moter Board suitable for 3 Phases 63A service connection made up of suitable angle iron frame work of size 2 feet x 1 1/2 feet using angle iron of size 1 1/2" x 1 1/2" x 1/4" rigidly fixed on wall covered with hylem sheet of size 2 feet x 1/2 feet of 6mm thickness with necessary bolts and nuts supports and supply and fixing of 3 Nos 63A fuse units (500V) 1 No. Neutral link, copper earth flat of size 1" x 1/4" with inter connection of EB meter to fuse units by 7/16 PVC insulated copper wire with earth connection complete SD-129
Supply and fixing of GI steel tubular pole for street light of6 Metre Length Double Bracket Pole with Base Plate (250 x 250 x 6mm) 76.10mm OD x 3.65mm Thick x 6000mm Length etc., complete.(PWD SOR 21-22 Pg.No:148 Item No : XV 1.b)
Supply and fixing of 30 watts LED out door street light fitting with LED etc., complete (PWD SOR 21-22 Pg.No:115 Item No : 17 a)
Supply and fixing of MS box of 30x20x10cm with angle iron frame work for housing the condensor, choke, fuse unit, SP switch with lock and key arrangements etc., complete (PWD SOR 21-22 Pg.No:126 Item No : VI 1 d)
Supply and fixing of 16 Amps fuse unit (500V) etc., complete (PWD SOR 21-22 Pg.No:134 Item No : 12 a)
Supply and fixing of 5A SP switch etc., complete (PWD SOR 21-22 Pg.No:122 Item No : 11 b)
Supply and fixing of TW plank for 16A switch and fuse unit etc., complete (PWD SOR 21-22 Pg.No:120 Item No : 6 a)
Earthing as per PWD standard specification with on earth electrode of 2m class 'B' pipe of dia not less than 32mm complete. Brass cable event for suitable armoured LTUG cable with earth connection suitable of 4 X 16sqmm etc complete SD 234
Supply and fixing of 4 X 16 sqmm PVC armoured LTUG cable in a trench to be excavated at a depth of 0.75m for covering the cable complete with 2" dia PVC pipe etc, complete (Electrical data 21-22 pg no : 23 Item No : 1 r)
Supply and fixing of Control DB metal box in size 4 X 4 with 4 pole connector 2 way 10A MCB neutral link etc, complete (Electrical data 21-22 pg no : 34 Item No : 16 - 1 - a)
Supply and run of 4 x 6 sq.mm (84/0.3) PVC insulated SC unsheathed Cu.Conductor of 1100V grade in 32mm dia GI pipe (Class 'B') suitably bent at both ends with necessary angle iron up right and end supports for mains SD-73
Supply of water supply materials including cost and conveyance etc, complete.
1'' PVC Pipe
4'' PVC Pipe
2'' PVC Pipe
2000 liter HDPE Tank
1" PVC Elbow
1" x 11/2" PVC Elbow
2" PVC Elbow
4" PVC Elbow
1" PVC Tee
2" PVC Tee
4" PVC Tee
1" PVC Union
4" PVC dummy
2" vent cowl
4" vent cowl
2"GM Gate valve
1"GM Gate valve
Lowering PVC rigid pipes, specails to trench and laying to proper grade and alignment jointing with PVC couplers with cement paste and testing to the required pressure including conveyance of water for filling during testing.
1'' PVC Pipe
4'' PVC Pipe
2'' PVC Pipe
Manufacturing, Supplying and Fixing of Stainless Steel Hand rails for staircase using 50mm dia 304L Grade Stainless Steel pipe of 1.60mm thick at required locations to a height of 900mm from finished floor level welded to 38mm dia Stainless Steel pipe post of 1.00mm thick as vertical at 900mm centre with 2 Nos. of 25mm dia intermediate horizontal stainless steel pipe of 1.60mm thick in between. The vertical pipe has to be welded to the 100 X 100 X 6mm MS base plate encased in the base concrete. The rate is inclusive of the charges for cutting, bending, welding, grinding, polishing, conveyance, electrical charges, etc. complete
Painting two coats with Ready Mixed Enamel Paint over the new iron works of approved quality and colour without priming coat including the cost all materials etc.,complete, in all floors.
Supplying and erecting in position of 500 liters capacity Industrial Model Reverse Osmosis Water-cum-Purifier to deliver Potable Water with World Health Organisation (WHO) Standards with following accessories. (a) MS Skid - 1 No. (b) Media 11054 No. Vessel with 20 nb Multiport Valve (with Media Pubble and Fine Sand and Activated Carbon Filling) set (c) Feed Pump 0.50 HP – 1 No. (d) Vertical Pump 2-9, 2.00 HP / Single Phase – 1 No. (e) Membrane 40 x 40 filmtech (or) equilaents / Osmonic (USA) - 1 No. and Membrane Pressure Vessel 40 x 40 -1 No. & Pressure Gauge - 2 Nos. (f) Flow Meter - 1 No. 20” Filter with Housing - 1 No., Low Pressure Switch - 1 No., Level Switch - 1 No. & Necessary CPVC Pipes and Fittings.The system shall be provide with Two Panel Control System with necessary Stainless Valves and Fittings and Float Control etc. The rate should be inclusive of all civil works, wherever necessary to install the System in position and intact.
Supply fixing and erection of CCTV Camara including cost and Conveyance of all materials to site etc complete as per Specification (5units / park)(PWD SOR Page (153 TO 157)
CCTV Camera
Network Video Recorder
Hard disc for NVR 8TB
24 Port Patch Panel
Rack With Accesssories -4U
Armoured LAN & CCTV Cable (CAT-6)
Led tv for display
Supply and fixng of GENERATORS WITH AUTO MAIN FAILURE (AMF) PANEL as directed by the departmental officers for pre-measurements etc., complete as per standard specification.(125 KVA)
Supply and fixing of Water CO2 Stored Pressure Type 9 litres capacity Fire Extinguisher as per new IS 15683 complete with control valve, gun metal cap, pressure gauge, operation sticker, discharge hose, wall mounting bracket, safety clip, etc., as directed by the Departmental Officers.
Structural Glazing: Providing and fixing structural glazing fabricated from roll formed sections made of galvanized steel colour coated (Base steel as per IS 513 of ‘D’ quality, galvanized as per IS 277 with Zinc of 120 grams / sqm.) with total coated thickness of 0.72mm. The glass holding section made of 304 grade SS of 0.6mm thick. Galvanized steel sections are to be used as stiffeners inside the colour coated steel / powder coated sections as per the design requirement. Design calculations are made to suit wind pressures as given in IS 875. Paint specifications: Primer coat with epoxy primer of 5-7 microns thick, finish painted with a polyester paint of 12-16 microns thick and back coated with alkyd backer of 5-7 microns or powder coated with pure polyester powder upto 50-60 microns thick.Dimensions: The section should be of 37 x 53mm for frame vertical, 37 x53mm for frame horizontal section and section for reinforcement should be of 31 x 55mm. glass holding section should be of 37 x 37mm for top and bottom grids in between should be of 37 x 18mm.Accessories: Brackets made of CRCA powder coated / electro plated should be used to fix vertical at top and bottom and vertical to slab as per site requirement. Polyurethane brackets should be used to connect horizontal section to vertical sections. Silicone: Natural cure, with good UV resistance to be used. The above frame should be fixed to brick / concrete masonry by using nylon self–expanding cap and driving MS electro plated 80mm long screws into the caps through frames. Glass: 5mm reflective Saint Gobain OR equivalent.
Supply and fixing of 8mm thick Calcium Silicate Board Designed and Perforated for False Ceiling as directed by the departmental officers for pre-measurements etc., complete as per standard specification.
Supply & Installation of 2.0 TR Split Type AC Unit Air-Conditioner with copper coil as directed by the departmental officers for pre-measurements etc., complete as per standard specification.
Provision for GST 18%
KGR&CO
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.47 MB
BOQ_306839.xls
BOQ • 0.33 MB
OfficeBuildingBidDocuments.pdf
Tender Documents • 0.56 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .