| 1 | L1₹12.9 LAccepted-AOC | L1 | Accepted-AOC Lowest and Reasonable | |
| 2 | L2₹13.3 L+₹26,267.45 (2.02%)Rejected-Finance SHIV BHAWAN MAGADH COLONY ROAD NO 03 SHERGHATI ROAD GAYA BIHAR PIN 823001 | GAYA | GAYA | BIHAR | 823001 | L2 | Rejected-Finance Not Lowest | |
| 3 | L3₹13.5 L+₹42,558 (3.26%)Rejected-Finance | L3 | Rejected-Finance Not Lowest | |
| 4 | L4₹13.9 L+₹86,213 (6.61%)Rejected-Finance | L4 | Rejected-Finance Not Lowest | |
| 5 | L5₹14.4 L+₹1.4 L (10.4%)Rejected-Finance D 9 NETAJI NAGAR KANTATOLI COLONY RANCHI 834001 | RANCHI | RANCHI | JHARKHAND | 834001 | L5 | Rejected-Finance Not Lowest |
Tender Value
₹14.4 L
EMD Value
₹28,800
Closing Date
17 Mar 2020, 6:00 pmClosed
GE DIPATOLI
GARRISON ENGINEER MES DIPATOLI MIL STN P.O. - HOTWAR RANCHI (JHARKHAND) 835217
SPECIAL REPAIR TO CONCERT BLDG NO. T-1/1, BLDG NO. T-2 AND BLDG NO. T-3/2 FOR IMPROVEMENT OF BETTER UTILITY OF HQ 63 INF BDE AT DIPATOLI
2019_MES_275513_2
8000/1520/E8
Open Tender
Civil Works
Item Rate
180 days
DIPATOLI
CLASS E CATEGORY a(i)
7 documents required · 7 mandatory
₹500
Yes
GE DIPATOLI
₹28,800
Yes
15 Jul 2020
3 Mar 2020
19 Mar 2020
3 Mar 2020
17 Mar 2020
5 Mar 2020
Amount
M&L for brick work with subclass ‘B’ bricks old size type, straight or curved on plan exc 6m mean radius, built in cement mortar (1:4) complete all as specified and as directed.
Taking down cement plaster including racking out joints, hacking for keys, scrubing down with water etc complete all as specified and as directed.
M & L for rendering 15 mm thick in cement mortar (1:4) on fair faces of brick work/concrete surfaces, surface finished fair and even complete as specified and as directed.
M & L for rendering 10 mm thick in cement mortar (1:4) as on ceiliing / soffit of slab and finished the surface fair and even complete as specified and as directed.
M&L for reinforced cement concrete (1:2:4) type B0, (using 12.50 mm graded stone aggregate) as in slab supported on wall, beam and column in floor, canopies, desc slab and in shelves and like work complete all as specified and as directed.
M&L for steel bars 10 mm dia and over TMT bar cut to length ,bent to shape required, including cranking, bending, spirally for hooping for column includind binding of mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and as directed.
Description all as per srl item No. 6 here in before but 6 mm to 8 mm dia as in stirrup complete all as specified and as directed.
Form work to soffit of suspended slab such as roof slabs, floor slabs, floor slabs landing and similar work n.exc 200 mm thick (horizontal or sloping) complete all as specified and as directed.
Form work to vertical /sloping edges of slab such as roof slabs, floor slabs, floor slabs landing and similar work complete all as specified and as directed.
M&L for granite (of any type) work (table rubbed and polished), 20 mm thick as in steps, jambs, pillars, window-cills, cooking platforms and like in cement mortar (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite with and including screed bed or bedding layer 15 mm thick in cement mortar (1:4) complete all as specified and as directed.
M&L for rounding to edges of stone slabs one edge, such as in steps, cooking platform, and other similar situations complete all as specified and as directed.
M &L for preparation of newly plastered surface of wall and applying three coats of white wash complete all as specified and as directed.
M &L for preparation of newly plastered surface of ceiling and applying three coats of white wash complete all as specified and as directed.
M&L for (400x400)mm x7 to8mm thick non skid ceramic floor coloured tiles laid in pattern of approved shade and finish as in floor, set and jointed in neat cement slurry and pointed in white/coloured cement to match with tiles with and including over 15 mm thick screed bed in CM (1:6) on concrete surface, rough finish to recive tiles with and including roughening old surfaces by picking, sweeping clean and washing down with water remove dust complete all as specified and as directed.
M&L for (300x200)mm x 6 to7mm thick glazed ceramic coloured/printed tiles in vertical surfaces laid in pattern of approved shade and finish, set and jointed in neat cement slurry and pointed in coloured cement to match with tiles with and including over 10mm thick rendering in cement mortar (1:4), with and including roughening old surfaces by picking, sweeping clean and washing down with water remove dust complete all as specified and directed.
Taking down chowkhats or frame with shutter (without taking off shutter from frame) area n. exc 1.50 Sqm each complete including removing from site complete all as specified and as directed.
Taking down chowkhats or frame with shutter (without taking off shutter from frame) area exc 1.50 Sqm but n exc 4.0 sqm each complete including removing from site complete all as specified and as directed.
S&F powder coated aluminium window shutter sliding type with frame of powder coated aluminium channel section suitable for sliding aluminium shutters weighing not less than 0.55 Kg/M including necessary joining cleats, glazing clips, rubber packing, powder coated aluminium shop beading screws with two shutter with and including 5.5mm thick coloured glass and one shutter with stainless steel wire gauge including necessary locking arrangement and handle etc., as specified etc., complete all as specified and as directed.
S&F powder coated aluminium ventilator louvre type with frame, aluminium section weighing not less than 0.55 Kg/M including necessary joining cleats, glazing clips, rubber packing, side handles fixed to wall with fastener etc., complete all as specified and as directed.
Providing & fixing powder coated aluminium door frame of approved manufacturer using approved aluminium section of following sizes fixed to floor, wall with rawl plug and screw complete in all respect complete all as specified and as directed by Engr-in-Charge. (a) Door frame of size 95.25 mm x 44.45 mm x 1.5 mm
M & L for double action floor spring hydraulically regulated made up of minimum 1.25 mm thick aluminium alloy sheet foundation box, main body with stainless steel cover, governing pivot made of brass, other parts made of mild steel heavy duty and fixed complete all as specified and as directed.
S&F frame work such as grills, grating etc with ends of bars shouldered and or rivetted or forged into spikes, framed guard bars, barred iron doors, ladders etc and similar wks conforming to Fe-290 Gd E-165 complete all as specified and as directed.
S&F mild steel works as in small articles like hold fasts, conforming to Fe-290 or Fe E-165 complete all as specified and as directed.
Providing and fixing ceiling board 8mm thick at all height false ceiling including providing and fixing of frame work made of special sections power pressed from M.S. sheet and galvanised in accordance with zinc coating of grade 350 as per IS : 277 and consisting of angle cleats of size 25mm wide x 1.6mm thick with flanges of 22mm and 37mm at 1200mm centre to centre one flange fixed to the ceiling with dash fastener 12.5mm diax40mm long with 6mm dia bolts to the angle hangers of (25x25x0.55)mm of required length, and other end of angle hanger being fixed with nut and bolts to G.I. channels (45x15x0.9)mm running at the rate of 1200mm centre to centre to which the ceiling section 0.5mm thick bottom wedge of 80mm with tapered flanges of 26mm each having clips of 10.5mm at 450mm centre to centre shall be fixed in a direction perpendicular to G.I. channel with connecting clips made out of 2.64mm diax230mm long G.I. wire at every junction including fixing the semless calcium silicate board with ceiling section and perimeter channels 0.5mm thick 27mm high having flanges of 20mm and 30mm long, the perimeter of ceiling fixed to wall/partition with the help of rawl plugs at 450mm centre to centre with 25mm long drive-all screws @ 230mm interval including jointing and fixing to a flush finish of tapered and square edges of the board with recommended filler, jointing tapes, finisher and two coats of primer & oil bond distemoer suitable for board and putty. The works shall be carried out as per manufacturer's instructions and literature.and also including the cost of making openings for light fittings, grills, diffusers, cutouts made with frame of perimeter channels suitably fixed all complete as per drawing and specification and direction of the Engineer in Charge.
Surface excavation n.exc 30 cm deep and averaging 15 cm deep and getting out complete all as specified and as directed.
M&L for providing hard core of broken boulders n.exc 63 mm guage, deposited, spread and levelled in layers n.exc 15 cm thick watered and rammed to true surface complete all as specified and as directed.
M&L for cement concrete (1:4:8) type D2 (using 40mm graded stone aggregate) as in sub base of hardstanding / pathway/ parking area complete all as specified and as directed.
M&L for 60mm thick machine pressed precast concrete interlocking paver block any shape and size coforming to IS 15658 - 2006, using rubber moulded casting with glosy finish with grey cement and pigment M-35 grade of concrete compete with and including over 25 mm thick sand cushioning complete all as specified and as directed.
M&L for providing precast cement concrete type (1:2:4) type B-1, (using 20 mm graded stone aggregate) solid block ( kerb stone ) of factory made (with plain or interlocking joints as directed) setting in CM (1:4) complete all as specified and as directed.
Removing surplus excavated soil to a distance exc 250m but n exc 500m and depositing where directed complete all as specified and as directed.
S&F in repair wire netting of stainless steel wire 1.4mm dia fixed with tinned tacks of stainless steel wire staples, size of mesh 12mm complete all as specified and as directed.
Hacking out old broken glass (any thickness, size, quality or desereption) from wooden/Steel frames complete all as specified and as directed.
M&L for 3 mm thick sheet glass ordinary quality and glazing with oil putty in square n. exc. 0.5 Sqm in each pane including glazing pins where required complete all as specified and as directed.
S&F in repairs 300mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified and as directed.
S&F in repairs aluminimum anolised barrel tower bolt of extroded section 150mm long complete all as specified and as directed.
S&F in repair aluminum handle cast type anodized size 150 mm long, complete all as specified and as directed.
M&L for preparation of previously treated/ old painted surfaces of wood or wood based materials including for knotting and stopping (of any description) over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified and as directed.
M & L for preparation walls/ ceiling, new or old and applying two coats of distemper oil emulsion complete all as specified directed.
Taking down copper /aluminium point wiring (light, fan, bell, socket or power) complete including fixture and fittings such as switches, ceiling roses, pendent, regulators, sockets, light fitting etc, removing materials to store for keeping in safe custody or for taking credit (credit a for above items should be made as per condition seperately) and making good distrubed surfaces of walls, floors etc complete all as specified and as directed.
Taking down carefully copper/aluminium sub main wiring of any size from surface/concealed /existing conduit of any height and removing materials at site and making good disturbed surfaces of walls, floors, roofs etc complete all as specified and as directed.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully from SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and as directed.
Taking down old burnt /unserviceable service cable after disconnecting of electric connection complete all as specified and as directed.
M&L for point wiring with 2x 1.5 Sq mm single core PVC insulated unsheathed copper multi stranded conductor (Phase - Red Colour and Neutral- Black Colour) in and including concealed PVC conduit of size 20 mm dia for incomer circuit and 25 mm for out going circuit marked inclusive of tees, bend, elbows etc upto and including sunk in anodized pressed steel box for housing switch, socket etc with white laminated 3 mm thick sheet cover of suitable size complete including PVC insulated multi stranded copper conductor 1.5 sq mm as earth wire (green colour) to common earth dolly for connection to ceiling rose to earth terminal incl cutting, chasses and making good disturbed surface to match with existing finish with plaster for One light /Fan point controlled by one one way switch complete all as specified and directed at site.
Description all as per per ser item No . 44 here-in-before but for one 3pin socket out let 5 Amps on the same board complete all as specified and as directed.
Description all as per ser item No. 44 here-in-before but for one 3pin socket out let 5 Amps on the independent board complete all as specified and as directed.
Description as per Srl items No. 46 here-in-before but point wiring with 2.5 Sqmm for 15 Amp socket outlet with 2.5 sqmm earth continuity complete all as specified and as directed.
S&F switch piano type single pole 5 amp 230 v complete all as specified and as directed.
S&F socket outlet 2 in 1, 5 pin, 5 amp complete all as specified and as directed.
S&F switch piano type single pole 15 amp 230 v complete all as specified and as directed.
S&F socket outlet 2 in 1, 6 pin, 5 and 15 amp complete all as specified and as directed.
S&F ceiling rose surface type bakelite (65x50) mm three terminals complete all as specified and as directed.
S&F stepped type electronic fan regulator flush type complete all as specified and as directed.
M&L for angle lamp holder, PVC /Polycarbonate type with back plate suitable for batten fittings complete all as specified and as directed.
S&F LED tube light fitting 1x 18/20 watt 230 Volt housing extruded aluminium heat shrink, complete with all accessories internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and as directed.
Taking down tube light fitting after disconnecting of electric connection and refixing of the same position before completion of work complete all as specified and as directed.
Hanging only ceiling fan and connecting up including provision of cable from ceiling rose to fan complete all as specified and as directed.
Fixing only exhaust fan and connecting up including provision of cable from ceiling rose /connector to fan complete all as specified and as directed.
Supply and fixing MCB DB SPN 8 Way, 230 Volts, double door made out of CRCA mild steel sheet with epoxy power coating IP 43 & IK 09 protection surface/concealed dust and vermin proof suitable for incorporation of incomer MCCB and outgoing MCB's and making all necessary connections complete all as specified and as directed.
S&F MCB SP 6 to 32 Amps, 240 volt 'C' Series 10 KA complete all as specified and as directed.
S&F MCB DP 40 Amps, 240 volts 'C' series 10 KA complete all as specified and as directed.
M&L for concealed sub main wiring 2 x 4 Sqmm (Phase -Red Colour and Neutral- Black Colour) along with earth wire 1x 4 Sqmm (Green Colour) with and including drawn through 25 mm medium grade PVC conduit complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning XLPE insulated, armoured, heavy duty, PVC sheathed electric LT UG cable with aluminium conductor, 1100 volts grade cross sectional area 70 sqmm 3.5 core connected with aluminium lugs connected by cramping tools complete all as specified and as directed. Note:- Excavation, earth work and protection of cable shall be measured and paid seperately.
Excavation in trenches not exceeding 1.5mtrs wide & not exceeding 1.5mtr in depth and getting out as in soft/ loose soil complete all as specified and as directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25cm thick complete all as specified and as directed.
Removing excavated material not exc 50mtr & deposited where directed at a level not exc 1.5mtr above the starting point complete all as specified and as directed.
M&L for sand filling in cable trenches for cable protection with clean dry sand unwashed including gently punning, complete all as specified and as directed.
M&L for bricks Sub class 'B' kiln burnt, well burnt, laid as in trenches/cable cover/protection complete all as specified and as directed.
Supply and laying under roads, hard surface, under culverts along poles light grade GI pipe of 50 mm bore dia including all fittings such as elbow, socket etc for cable protection complete all as specified and as directed.
M& L for trenchless boring under road/hard standing or any other situation by manual mean for passing GI pipe upto 50 mm bore grade and making good both the ends complete all as specified and as directed.
S&F in replacement of Ultra slim LED panel tube light fitting 36 watt 230 Volt made from extruded aluminium housing frame (recesss/pendant) of size 2' x2' complete with all accessories internally pre-wired and inncluding connecting up with twin core twisted flexible copper conductor cable with suitable size complete all as specified and directed.
Supply and fixing MCB DB TPN 4 way double door with metal door suitable for provision of MCCB and MCB's complete all as specified and as directed.
S&F MCCB 63 Amps, 415 V, 16KA 4 pole with thimbles/lugs and nut, bolts complete all as specified and as directed.
Supply, laying, jointing, testing and commissioning XLPE insulated, armoured, heavy duty, PVC sheathed electric LT UG cable with aluminium conductor, 1100 volts grade cross sectional area 35 sqmm 4 core connected with aluminium lugs connected by cramping tools complete all as specified and as directed. Note:- Excavation, earth work and protection of cable shall be measured and paid seperately.
M &L for GI earthing complete with GI earth plate electrode 60cm x 60cm x6 mm thick buried directly in ground verticvally to size of depth not less than (0.90x 0.60)m x 2.25 mtr below ground level with top edge of the plate at a depth not less than 1.5 mtr below ground level, earth plate connected to galvanised earth strip of size 32x6 mm, 7.5 mtr long by means of brazing nuts, bolts, check nuts, & washers, testing of completion (drawn in earth lead protection pipe light gade GI of size 40 mm dia) by means brazing at both edges with vertical plane of electrode all as shown in plate No 3 of SSR Part - I connected to earthing strip with main switch/main control board,filling with charcoal dust 200 Kg, and common salt 100 KG, including necessary excavation and earth work in any type of soil, perforated watering pipe, funnel with wire mesh, earth lead protection pipe light grade PCC chamber (1:3:6) type C1 (for even finish on both the faces) and RCC cover (1:2:4) Type B1, (450 x450)mm x50 mm thick with 6 mm dia CTD bars 150 mm c/c with 2 Nos of handles of 10 mm dia steel rod complete all as specified and as directed and testing on completion and connected to equipment with lugs and screw nuts etc complete all as specified and as directed.
S&F in replacement of single pointed air terminal (spike) of rod 20 mm dia 1000 mm long fixed on aluminum strip complete all as specified and as directed.
M&L for galvanised iron strip (32 x 6) mm size as down conductors fixed on and including porcelain cleats/insulators, brazed joint complete all as specified and as directed. Note: Porcelain cleats/insulators shall be measured and paid separately.
S&F in replacement of test point terminal block made of gun metal or Phosphorus bronze size (75x75x25) mm drilled and screwed with and including 3 Nos 8 mm dia 25 mm long hexagonal head screw complete all as specified and as directed.
S&F porcelain cleat/insulator of suitable size for fixing copper strip of lighting arrestor conductors complete all as specified and as directed.
Supply and fixing in replacement of galvanised iron tubing medium grade 40 mm bore with GI fittings laid in trenches / floors for passing through copper/aluminum strip complete all as specified and as directed.
Cutting the existing road/hard standing surfaces to a depth of 15 cm and 0.10 cm width and getting out for laying of aluminum strip protection including removing/returning filling with top 15 cm thick with PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) and finishing the surface even and fair without using extra cement including disposal of surpluse soil complete all as specified and as directed.
Demolition of cement concrete in ground floor and paving n.exc 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for PCC (1:2:4) type B1 using 20 mm graded aggregate as in floors/fixing of porcelain insulator etc with cement mortor (1:4) complete all as specified and as directed.
S&F in replacement LED building security light fitting 35 Watt with suitable size of GI bracket, fix with GI clamp in aluminium pressure die cast housing with toughened glass cover ( IP 66 protection) luminaire with high power LED as light source complete all as specified and as directed.
M/S ABHAY KUMAR AND BROTHERS
M/S ALLIED MACHINERIES AND ENGINEERS
RAMRAS BUILDERS
M/s Kundu Enterprises
Excel Enterprises
Associated Engineers
M/s Kamleshwar Singh
Delhi Enterprises
M/s Mukesh and company
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .