| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1st₹1.1 LAccepted-AOC | ₹1.1 L | 1st | Accepted-AOC L1 |
| 2 | 2nd₹1.2 L+₹4,572 (4.04%)Rejected-AOC | ₹1.2 L+₹4,572 (4.04%) | 2nd | Rejected-AOC L2 |
| 3 | 3rd₹1.2 L+₹10,180 (9.00%)Rejected-AOC | ₹1.2 L+₹10,180 (9.00%) | 3rd | Rejected-AOC L3 |
| 4 | 4th₹1.3 L+₹12,555 (11.1%)Rejected-AOC | ₹1.3 L+₹12,555 (11.1%) | 4th | Rejected-AOC L4 |
| 5 | 5th₹1.4 L+₹28,250 (25.0%)Rejected-AOC | ₹1.4 L+₹28,250 (25.0%) | 5th | Rejected-AOC L5 |
Tender Value
Refer Docs
EMD Value
₹3,957
Closing Date
24 Jul 2020, 3:00 pmClosed
Executive Engineer
EandM Division, APWD, Prothrapur, Port Blair
Repair and Renovation of JPP, HazariBagh at Ferrargunj
2020_APWD_472_1
01/EE/EandM/20-21
Open Tender
Electrical Works
Item Rate
60 days
South Andaman
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
Executive Engineer, EandM Division, APWD
₹3,957
Yes
20 Oct 2020
14 Jul 2020
27 Jul 2020
14 Jul 2020
24 Jul 2020
16 Jul 2020
15 Jul 2020 - 16 Jul 2020
Amount
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S. box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required a) Group-C
Wiring for circuit/ sub main wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required. a) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
b) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed medium class PVC conduit along with 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing following piano type switch/ socket on the existing switch box/ cover including connections etc. as required. a) 5/6 Amps switch
b) 3 pin 5/6 Amps socket outlet
c) 15/16 Amps switch
d) 6 pin 15/16 A socket outlet
Supplying and fixing of PVC Box of following sixe on surface with suitable size of cover plate in the front including connection etc., as required. a) 2 Way ( for 5 Amps) (4" x 4")
b) 4 Way ( for 5 Amps) (3.5" x 6")
c) 6 Way ( for 5 Amps) (3.5" x 10")
d) 2 Way ( for 15 Amps) (4" x 7")
Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required
Supplying and fixing brass batten/ angle holder including connections etc. as required
Supplying of LED Lamp 12W B22 etc., as required for Batten Holder
Supplying of LED Fitting Box Type luminaires equivalent to Crompton Cat No. IGP131LT8 - 16 and LED Lamp T8 equivalent to Crompton Cat No. LT8 - 20- 865 - 2 or equivalent.
Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required
Supplying and fixing of Street Light luminaires 25 Wattage, with pressure die cast aluminium glass i/c Clamping arrangement with GI Pipe etc., as required. (Equivalent to Crompton Cat Ref LSTS - 25 - CDL) including Clamping arrangement with GI Pipe etc., as required.
Supplying of AC Ceiling Fan (1200 mm) Sweep ISI Marked 5 Star rated with Step type electronic regulator i/c down rod of standard length 30 cm with all accessories similar to Havells ES - 50 Premium or its equivalent
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 12 way, Double Door
Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. a) Single pole
Supplying and fixing following rating, double pole, 240 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required a) 40 A
Supplying and erection of metering box made out of SMC of overall size 310 mm x 285 mm x 180 mm with hinged cover and locking arrangements, viewing glass etc., as required.
Providing earthing with safe earthing electrode of galvanization 80 to 100 microns, length 2000mm, outer dia 50 mm, inner dia 19 mm and inner space be filled with crystalline conductive mixture including filling -up with electrolite (Back fill compound) as required for safe earth electrode and providing masonary enclosure with cover plate having locking arrangement etc. as required. (Ashlok)
Providing and laying earth connection from earth electrode with 4.00 mm dia copper wire in 15 mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing as required.
M/s G K Construction
NAVJEEVAN ENTERPRISES
M/s Sai Electrical Works
C. KUMAR
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .