Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.0 LAccepted-AOC E 84 OF HQ CWE NW MUMBAI AGE 87 1 3 GEETA NAGAR NAVY NAGAR COLABA MUMBAI 400 005 | MUMBAI | MAHARASHTRA | 400005 | L1 | Accepted-AOC BEING LOWEST | |
| 2 | L2₹29.6 L+₹8.4 L (39.8%)Rejected-Finance A 14 USHA SADAN NEAR POST OFFICE COLABA MUMBAI 05 | MUMBAI | MUMBAI | MAHARASHTRA | 400005 | L2 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 3 | L3₹35.2 L+₹14.1 L (66.6%)Rejected-Finance 4 S1 A 405 ZODAIC MARATHON NEXZONE NH4 PALASPE PHATA REES RAIGAD MAHARASHTRA 410 206 | RAIGAD | MAHARASHTRA | 410206 | L3 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 4 | L4₹38.9 L+₹17.7 L (83.7%)Rejected-Finance NOT AVAILABLE | L4 | Rejected-Finance BEING OTHER THAN LOWEST | |
| 5 | Rejected-Technical ROOM NO D 290 PART III GALI NO 8 SHREE GANESH MURTHI NAGAR CUFFE PARADE ROAD COLABA MUMBAI 400005 | MUMBAI | MAHARASHTRA | 400005 | - | Rejected-Technical Adverse remarks on WLR of HQ CE SC PUNE Q/E Mar 23 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
13 Sept 2024, 6:00 pmClosed
GE NW NAVY NAGAR COLABA MUMBAI
GE NW NAVY NAGAR COLABA MUMBAI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI
REPAIR MAINT OF CEILING FAN EXHAUST FAN WITH CONNECTED ACCESSORIES INCLUDING SAFETY CHECKING OF CEILING FAN AND OTHER MISC EM FITTINGS AND FIXTURES IN HIGH RISE BUILDING AT RS COLABA NAVY NAGAR COLABA MUMBAI
2024_MES_667364_1
8397/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE NW NAVY NAGAR COLABA MUMBAI
Class D and Category b(i)
8 documents required · 8 mandatory
₹500
GE NW NAVY NAGAR COLABA MUMBAI
₹90,000
Yes
3 Oct 2024
22 Jul 2024
16 Sept 2024
22 Jul 2024
13 Sept 2024
5 Aug 2024
22 Jul 2024 - 12 Aug 2024
Amount
Disconnecting of electric connection from ceiling rose and taking down ceiling fan any type and any sweep from roof/wall of various buildings and shifting the same to MES store yard/ workshop, dismantling the same to check and assess the defect and reassembling the same after carrying out necessary repairs/ renewal of copper wire winding/defective parts including testing in E/M store yard and renewal of PVC insulated flexible twin core twisted copper conductor cable of size 23/.0076 and re-hanging/re-fixing and re-connecting the same, complete all as specified and directed. Note: (i) M&L for copper wire winding of fans,overhauling of fans and supply only of parts of fans shall be measured and paid separately under appropriate items. However, cost of PVC insulated flexible cable shall be deemed included in the unit rates of this item. ii) Labour Rates for 'Supply only Items' shall deemed to be included in the quoted rate of this item.
Rewinding of ceiling fan/wall mounted fan/pedastal fan any size as per IS-13730 using super enameled copper wire of same guage complete and directed. Note: Canopy, bushes, bearing, cap and fan blade measured and paid separately.
Overhauling of ceiling fan any size and Make, dismantling parts, properly cleaning/removing old existing grease oil and applying new oil grease, varnishing of winding, cleaning dust rust and assembling and connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076, including replacement of canopy, bushes, bearing, cap and fan blade complete all as specified and as directed by Engr-in-Charge.Note: Canopy, bushes, bearing, cap and fan blade measured and paid separately.
Supply only ceiling fan canopy suitable for 15mm dia rod with fixing Nuts and Bolts as approved by Engr-in-Charge
Supply only gun metal bush suitable for any sweep fan of any make
Supply only capacitor 2.5Mfd.
Supply only ball bearing suitable for 1200/1400mm sweep Ceiling fan.
Supply and Fix and replacement of15mm dia MS clamp assembly with Nut, Bolts & rubber bush suitable for down rods and split pins including taking out old one as approved by Engr-in-Charge
Supply and fixing in repair ceiling fan down rod of length 300/450 mm, inner diameter 15mm and thickness not less than 1.5mm with clamps Nuts, Bolts and washers for existing ceiling fan as approved by Engr-in-Charge
Supply only ceiling fan GI blade suitable to any sweep and makes complete all as specified and as directed.
M & L for fabrication of fan hook made out of SS rod and fan Hook bend to shape 'S' after taking out old one.
M & L for preparing ceiling fan surfaces for painting by removing/cleaning dust and deposited material and applying two coats of white enamelled paint by spray to fan blades, body and down rod, canopy of ceiling fans complete all as specified and as directed
Taking out unserviceable ceiling fan and deposit to MES Store, supply and replacement with ceiling fan 230V, 50 Hz, AC, 1200mm sweep, min air delivery 210 CFM with service value 6.00 BEE, five star rated with brushless direct current motor (BLDC) complete with hanging arrangement by down rod alongwith steel wire rope for additional safety in ceiling fan with all allied accessories and connecting up with three core, 0.75 sqmm PVC insulated copper conductor cable complete all as sepecified.
Disconnecting of electric connection from ceiling rose and taking down exhaust fan any type and any sweep from roof/wall of various buildings and shifting the same to MES store yard/ workshop, dismantling the same to check and assess the defect and reassembling the same after carrying out necessary repairs/ renewal of copper wire winding/defective parts including testing in E/M store yard and renewal of PVC insulated flexible twin core twisted copper conductor cable of size 23/.0076 and re-hanging/re-fixing and re-connecting the same, complete all as specified and directed. Note: (i) M&L for copper wire winding of fans,overhauling of fans and supply only of parts of fans shall be measured and paid separately under appropriate items. However, cost of PVC insulated flexible cable shall be deemed included in the unit rates of this item.
Overhauling of Exhaust fan any size and Make, dismantling parts, properly cleaning/removing old existing grease, oil and applying new oil grease, varnishing for winding, cleaning dust, rust and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4 Mfd, body cover etc and reassembling, connecting with copper conductor multi stranded 3 core wire of size 14/0.0076 complete Note: Rate of petty items to be replace shall be included in quoted rate.
Taking down deteriorted louvers and Supplying and fixing new louvers made out of 16SWG GI sheet with machine pressed cut for horizontal ventilation at any height up to (G+14 floor) suitable for 300mm sweep exhaust fan complete all as specified and as directed by Engr-in-Charge.” Note :- Neccessary scaffolding, Safety belt, and net for G+14 high rise buildings shall be provided by the contractor and cost of the same are deemed in quoted rate.
M & L for rewinding of exhaust fan with super enamelled copper wire of same size/gauge, no of turns as per existing, varnishing, oiling and greasing of any make of size 230/300/380mm sweep by dismantling its parts and replacing petty items with new as required such as Nuts, Bolts, washers, bushes, ball bearing, cap, fan shaft, rotor, capacitor 2.5/4 Mfd, body cover and cleaning of exhaust fan body and its blade by cleaning agent, assembling, and connecting complete with copper conductor multi stranded 3 core wire of size 14/0.0076. Note: Rate of petty items to be replace shall be included in quoted rate.
All as per Item No 17.00 above but of size 450mm sweep.
S & F Exhaust GI fan blade suitable to any sweep exhaust fan and makes complete after taking out old one all as specified and as directed by Engr-in-charge.
M&L for preparing exhaust fan of any size surfaces for painting by removing/cleaning dust and deposited material and applying two coats of grey enamelled paint by spray to Exhaust fan body, blades and louvers complete all as specified and as directed by Engr-in-Charge
Cutting hole in existing concrete or brick wall suitable for fixing 230/300/450mm sweep exhaust fan making good the hole including proper internal plaster work and surface finish in side and outside the hole as per site requirement complete all as specified and directed by Engr-in-Charge
Taking out unserviceable Exhaust Fan and Supply and fix Exhaust fan, 4 blade, heavy duty, double ball bearing, 230V, 50Hz,300mm sweep having power input 70W speed 1440RPM including connection as required at site with flexible copper cable all as per specified and directed. Note : Old unserviceable exhaust fan will be deposited in MES store.
Inspection/ checking of serviceability for ceiling fan to avoid any accident on site a job shall be done as taking down ceiling fan from its position, checking and replacement of minor unserviceable and minor defective spare parts responsible for any accident (i.e. 'S' hooks, split pin, cotter pins, rubber bush etc) servicing the fan completely after removing of old grease from bearings and compulsury fixing of safety wire (SWR with self locking nut and screws) from fan motor to Ceiling hook incl hanging it to its same location after complete assurence of any defect and connecting with copper conductor multi stranded 3 core wire of size 0.75 sqmm complete all as specified and as directed by Engr-in-Charge.
Note 1. : Complaint pertains to unserviceable ceiling fan/Exhaust Fan as given by the Engr-in-Charge shall be attended within 48hrs from the day of complaint assigned to the representative of the firm as directed by Engr-in-Charge upto the satisfactory level and on failing which the penality shall be imposed @ Rs 250/- per day per item of Schedule.
Note 2. : The Contractor or the accredited representative of the firm shall report to the JE concerned at the E/M Complaint Cell i.e Sub Station RS-1 Colaba resp for receiving the complaints at 0900 to 1000hrs daily excluding Sunday and Holiday
Taking down carefully copper/ aluminium point wiring ie. light, fan, socket or power/ points complete, including fixture and fittings such as switches, ceiling roses, holders, regulators, sockets etc. and making good disturbed surfaces of ceiling, walls, floors, etc.
Material and labour for point wiring complete with proper colour coding using, 1100 volts grade, 1.5 Sqmm, PVC insulated FRLS, unsheathed wire with multi stranded copper conductor confirming to IS-694, part-II, ISI marked and including PVC casing and caping not less than 25 mm size, ISI mark with all accessories on wall/ceiling/floor/roof etc, including 1.5 Sqmm, PVC insulated, FRLS, unsheathed, 1100 volts multistranded copper conductor green colour as continuous earth wire connected to common earth dolly all as specified and directed for the following :- NOTE : Circuit conductor from MCB DB to Switch boards should not be less than 2.5sqmm.
One light/Exhaust/Ceiling fan point controlled by one switch.
One 3 pin socket outlet, 5 Amps on the same board with other switches
One 3 pin socket outlet, 5 Amps, on the independent board
One bell point controlled by one push button
All as per item No 25.00 above but with 2.5 sqmm cable for one three pin 15 Amps socket out let controlled by one switch.
S & F modular switch, 1 module, single pole one way 6 Amp confirming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular switch, 1 module, single pole one way 6 Amp confirming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F modular socket 6A, 3 pin, 2 module confirming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular socket 6A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular switch, 1 module, single pole one way 16 Amp conforming to IS:3854 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F modular socket 6/16A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular socket 6/16A, 3 pin, 2 module conforming to IS:1293 : 2019 and ISI marked complete all as direcred. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F modular stepped type fan regulator, 2 module, single pole one way ISI marked. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular stepped type fan regulator, 2 module, single pole one way ISI marked. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F modular bell push switch, 1 module, single pole one way 6Amp ISI marked. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
S & F in replacement with modular bell push switch, 1 module, single pole one way 6Amp ISI marked. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
Supply & Fixing Retrofit LED lamp 7 Watts complete all as specified and directed.
Supply & Fixing in replacement Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Supply & Fixing Lamp holder, PVC/Polycarbonate type with back plate suitable for batten fittings complete all as specified and directed.
Taking out old wooden/PVC board and disconnecting all electric connection from switches, board and S & F modular PVC Gang box of 12 module, ISI marked for mounting of modular switches and sockets including blank plate for blank module. Make - Crabtree(Athena)/Anchor(Penta)/Legrand(Britzy)
All as per Item No- 42.00 above but of modular PVC Gang box, 8 module.
All as per Item No- 42.00 above but of modular PVC Gang box, 6 module.
All as per Item No- 42.00 above but of modular PVC Gang box, 4 module.
All as per Item No- 42.00 above but of modular PVC Gang box, 3 module.
All as per Item No- 42.00 above but of modular PVC Gang box, 1/2 module.
S&F modular white cover plate with frame, 12 module.
S&F modular white cover plate with frame, 8 module.
S&F modular white cover plate with frame, 6 module.
S&F modular white cover plate with frame, 4 module.
S&F modular white cover plate with frame, 3 module.
S&F modular white cover plate with frame, 1/2 module.
Taking down unserviceable FTL/batten fittings and supply and fix LED batten fitting 20 Watt, 240V, 4ft CDL/NW comprises of extruded channel in thermally conductive material with decorative end cap and high translucent serration milky white diffuser of high optically efficient plastic FR grade. The luminaire is pre-wired with high efficiency electronic driver having operating voltage 140-270V, P.F >0.95, THD <20% and IP20 protected alongwith provision of two Nos of PVC box of size 75x75x20mm for mounting light fittings including ceiling rose. The contractor shall provide test certificate from authorized lab. Make of Light Fitting : Wipro/Crompton/Philips/Bajaj/Polycab
S&F MCB DB SPN confirming to as per IEC 61439-3 and IP 43, IK 09 with acrylic door, 8 way complete with din rail, Neutral and Earthing bar after taking out the old unserviceable DBs, connection complete and making good the disturbed surfaces by plastering or PCC work inclding distembering to the affetced to walls. Make : Legrand/Havells/Siemens/L&T
Taking out Old U/S and S&F MCB SPN, 32 Amp, 10 KA, 230 Volt. Make : Legrand/Havells/Siemens/L&T
Taking out Old U/S and S&F MCB, single pole, upto 20 Amp, 10 KA, 230 Volt. Make : Legrand/Havells/Siemens/L&T
S & F in replacement with Analog time switch 3P Module, 24 hours program, programmable every 15 min., backup of 100 hours, current capacity 16A for ON/OFF controlling of security lights complete all as directed.
S & F in replacement with power contactor 3 pole AC, with 240 volt coil, 32 Amp rating confirms to IS / IEC 60947-4-1 for ON/OFF controlling of security lights complete all as directed.
Supply and fixing in repairs of MCCB DB VTPN 8 way as per IEC 61439-3 Suitable for Flush /Surface mounting with 250 A Copper Busbar for each phase with 2 Neutral bar, 2 Earthbar and Cable ties for Cable management fully insulated busbar & shrouded Neutral bars improved Pan assembly for ease of installation prefitted masking sheet reversible metalic door for IP 43 & IP 54 DB's with provision for 100 Amp 4pole MCCB as incomer and SP/TP MCB's as outgoing complele all as specified and directed. Make : Legrand/Siemens/Schneider/ABB
Supply and fixing in repairs of MCCB 100A, 25kA, 4P, Thermal magnetic release , Ics=100% Icu . Make : Legrand/Siemens/Schneider/ABB
Supply and fix in repairs MCB TP 63A, 10kA, 415V. Make : Legrand/Siemens/Schneider/ABB
Supply and fix in repairs MCB SP 63A, 10kA, 240V. Make : Legrand/Siemens/Schneider/ABB
S & F ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm.
S & F in replacement with ceiling rose with earth terminal connection, 3 terminal/ PVC/ polycarbonate, isolated body of size 60x50mm.
S & F in replacement with electric bell ding dong, AC, 230V single pole.
M & L for earthing complete with Galvanised steel earth plate eletrode 60cmx60cmx6mm thick buried directly in ground vertically to (earth pit not less than 2.25 meters deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised Iron Strip of size 32x6mm size, by means of Bolts, Nuts, Check Nuts and washer made of GI or Steel Earth connecting with test point, provision of Charcal and salt in alternate layers, watering pipe 20mm dia medium grade MS funnel with jali, PCC M-15 Type B-1 in pit with XPM not elss than 4Kg per Sqm and Earthpit with cover returning, filling, removing excavated material all as specified in electrical plate No 3 of SSR Part-I making good excavated surfaces such as hard standing refixing machine pressed precast concrete interlocking paver blocks removed during excavation on earthpit to mach existing surfaces after taking out old/unserviceable one complete and testing on completion all as specified and directed by Engr-in-Charge
Supply and Fix and replacement of electronic control circuit card suitable for BLDC ceiling fan of existing make and existing model including taking out old one complete all as specified and directed by Engr-in-Charge
S S ENTERPRISES (BID ID -3090757)
JANKI ENTERPRISES (BID ID -3095633)
SHREE JAGDISH FURNITURE CO. (BID ID -3084827)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .