Electrical work for Construction of new Running room for Crew and train Manager at Haridwar & Electrical work for Improvement of Health Unit at Laksar and other misc allied works.
15_SrDEE_G_MB_2026~NR
15_SrDEE_G_MB_2026
Open
Works - General
6 Months
Haridwar, Uttarakhand
₹0
₹1.1 L
17 Jun 2026
26 May 2026
3 Jun 2026
A-Electrical work for Construction of new Running room for Crew and
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess as required of following sizes:-
Supply of Batten/Angle Holder/Ceiling rose & installation with 3mm thick white Phenolic laminated sheet on the Junction Box/ Fan Box etc of laid conduit including connections, Testing & commissioning as per relevant IS and Tech. Specification and as per site requirement.
Supply & fixing of complete 18-20 watt LED, tube light fitting 1200 mm Integrated with Aluminium Extrusion Base with LED & Driver, decorative pin type end caps & copper contacts with Diffuser made of transparent polycarbonate with tube light, operating voltage single phase 230 volt AC, 50 Hz conforming to CEE/NR specification No. -CEE/NR/121-Elect./PS/2018(Rev. 3) ,dated. 28.06.2018 and PCEE/NR/121-Elect/PS/2019 (Rev-4), dated 04.11.2019 or Latest.
Supply, erection, fixing, testing & commissioning of BLDC Ceiling Fan of sweep 1200 mm, Air delivery range from 210 cubic metre per minute to 220 cubic metre per minute and input 7 power consumption range from 26W to 35W ( Star Rating - 5 Star, Service Value - 6 & above cubic metre per minute per watt ) with remote for speed control of fan suitable for operation on 1 Ph, 50Hz, 240V power supply system (conform to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable )
Supply,fixing,testing and commissioning of 380mm sweep,1400 rpm (approx) propeller type exhaust fan complete as per IS,IE rule & site requirement.
Supply, fixing, testing & commissioning of Main TPN Distribution Board Double Door 4 way complete with 01 No. MCCB 63/100 Amps.( 4 pole, 35 KA ) and 12 Nos. SP MCB 6-32 Amps. of 10 KA complete in all respect & as per IS technical specification & site requirement.
Design & Manufacture, Supply, Installation, fixing, testing & commissioning of 8 way MCB Distribution Board , dust & vermin proof, 3 phase, 4 wire 415 volt, AC supply system. The switch board shall be complete with inter connections, instrument connections with copper conductor cable 10 as per IS 13032, Phosphatised & Painted with epoxy polyester based powder paints. Three phase Double Door Sheet steel Enclosure detachable gland plates, flush/surface mounting for MCB's fitted with Bus bars, Earth bars & Neutral links etc.of suitable capacity, comprising of following ie .Double door 8 way Distribution Board 1 No, 1x 40 A.MCB DP 10 KA, 240/415 V., 50 Hz.& 6x16-32 A.MCB SP 10 KA, 240/415 V., 50 Hz (IP55) complete in all respect as per site requirement/IE Rule & tech. specification.
Design, Fabrication, Supply, Fixing and commissioning of double door IP 65 Feeder Pillar ( Size- 0.4 m.x0.4 m.x0.5 m.) made of Angle Iron size - 40x40x6 mm.covered from all sides 11 with MS Sheet 20 SWG including door with hinge, locking arrangement, nut & bolts, Aluminum Bus Bar ( Size-35x5x400 mm.), Bakelite Gutka, cable glands, Earthing points, Cement, sand, interconnections etc. and grouting with sand & cement and painting with two coats of enamel grey paint over a coat of red oxide primer for antirust complete in all respect & as per site requirement.
Earthing with 40mm dia. GI pipe class 'B' , 3 meter long, earth electrode as per IS:3043 (latest version) to achieve earth resistances less than 5 ohms including construction of 12 masonry enclosures with hinged cover plate of cast iron/RCC(Heavy Duty with lifting arrangement) with locking arrangement as required (Outer hole size: 450XmmX450mm and Cover plate(CI/RCC) size:300mmX300mm) on top, provision of earth plate, connections from earth electrode to switch gear/pole as per technical Specification/I.E. Rule.
Supply, installation, testing & commissioning of complete 60 watt LED Street light 13 fitting, operating voltage single phase 230 volt AC, 50 Hz with suitable Pressure Die Cast Aluminium Housing and LED Driver conforming to CEE/NR specification no. CEE/NR/121-Elect/PS/2018 (REV-3), dt. 28.06.2018 & PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt:04.11.2019 (Attached) or latest.
Laying, underground/road/Railway track, recessing in platform/ wall along with Rly. Track/in laid RCC/GI pipe as required 1.1KV grade LT XLPE insulated armored, aluminum conductor cable including making chase & plastering after laying of cable/digging of cable trench, sand cushioning, protective covering with second class bricks width wise, provision of cable route marker 15 as per Tech. Specification including end terminations with aluminum clamping socket/lugs lugs testing & commissioningand shall be in conformity to IS 1255 /1983 (Latest Version). Excavation shall be done complying with code of safety as per IS 3764/1992. Cable route plan should be submitted by firm for approval of C.A. before execution. Cable route marker should be attached with the laid cable through 'J' hook and display board should be above the ground.) Note: Cable will be supplied by Railway.
Provision, supply and laying by Horizontal Boring Trench less method 2.5 meter deep 16 or more as per relevant IS suitable for laying HDPE Pipe of 110 mm outer dia. with 6 mm wall thickness in the bore for laying of cable under track/road/culvert etc. Excavation shall be done complying with code of safety as per IS 3764/1992 and as per site requirement. (Supply of HDPE pipe as per IS:4984-2016 (latest version) included).
Design & manufacture LT switch board as per IS 8623(Latest version), Supply, Installation, fixing, testing & commissioning of cubicle , floor /wall mounted type, dust & vermin proof LT Switch Board, 3 phase, 4 wire 415 volt, AC supply system. The LT Switch Board shall be 17 powder coated. The incoming feeder shall be provided with three phase KW meter ( Range 0 to 100 KW). The switch board shall be complete with inter connections, instrument connections with copper conductor cable, 400 Amps. Copper bus bar & front operated switchgears, Digital Voltmeter(0 to 500 Volts), Digital Ampere meter (0- 200 Amps) with Selector switch I/C with Indication lights ( lamp set.) earthing studs etc. comprising of following i.e. I/C -MCCB 400 Amps(36 KA) 4 Pole-1 No. (DN 3 type), O/G- 125 Amps MCCB(36 KA) 4 Pole-05 Nos. (DN 2 type) with 200 Amp COS , complete in all respect.
Earthing with 600x600x3 mm thick copper plate earth eletcrode as per IS : 3043 ( 18 latest version ) to achieve earth resistance less than 1 ohm including construction of masonry enclosure with hinged cover plate of cast iron with locking arrangement ( Approximate size 600x600 mm. on top, watering pipe, connections from earth plate to top with 40x6 mm. copper strip in 50 mm. dia GI pipe class ' B ' provision of earth plate as per drawing and technical specification.
Connections with 40x6 mm. copper strips in 50 mm dia GI.pipe class' B' 300 mm. deep in ground / recessing in floor from earth elctrode strip to nutral of transformer / alternator as per drawing and technical specification including supply of material complete in all respect.
Supply, erection, fixing, testing & commissioning of Modular AC box with 32 Amps plug socket and 32 Amps. DP MCB (10 KA) complete in all respect & as per site requirement.
Supply, installation, testing & Commissioning of light weight wall mounted type Voltage Stabilizer confirming to IS : 8448 suitable with toroidal care transformer having capacity 4 21 KVA, input voltage 135 - 290 Volt and output voltage 220 - 240 Volt, MCB 32 Amps, time delay relay ( 2 - 4 min ) with soft touch type instant and start switch, under voltage and over voltage cut off with indicators. Digital Voltmeter and Ammeter with soft type selector switch for measuring input & output voltage, indicator for power ON and timer ON.
Installation, fixing, testing and commissioning of 1 to 2 ton capacity Split type AC 22 including suction / discharge copper tubing charges & ducting arrangement for waste water discharge complete in all respect & as per site requirement. (Air conditioners will be supplied by Railways).
Supply, erection, fixing, testing & commissioning of 1200 mm sweep Energy efficient Ceiling fan with fan regulator etc. complete in all respect as per CEE/NR spec no. CEE/NR/123- Elect/PS/2018, dt.15.10.2018 (Attached) or latest & as per site requirement.
Supply,Fixing, testing & commissioning of LED based Reading light/Bed lights, system wattage 1 W, cool white with compatible inbuilt LED driver.
Supply, fixing, testing and commissioning of LED down lighter, housing aluminum die 25 cast, white powder coated and PMMA diffuser having system wattage less than or equal to 15 Watt complete with all mounting arrangement, complete with accessories conforming to CEE/NR's spec. No. CEE/NR/121-Elect/PS/2018 (Rev- '3') or latest & PCEE/NR's spec. No. PCEE/NR/121-Elect/PS/2019 (Rev- '4') or latest.
Supply, Installation, testing & commissioning of Concealed MS box size 4 Inch for Downlighter as per site requirement.
Supply & Fixing of 4 pole RCBO 125 amp,300mA/100mA,complies to standard ICE/EN61009.
Supply,erection & commissioning of 2 pole RCCB electromagnetic type with 30/100/300mA senstivity and having capacity 16/25A,complete as per tech. specification.
Supply, fixing, testing & commissioning of LED light luminaries 595 X 595 mm size, Tile type, having system wattage 36-45 Watt , CRCA body powder coated , high efficiency milky white PMMA diffuser with no bright spot visible, complete with all mounting arrangement accessories conforming to CEE/NR specification no. CEE/NR/121-Elect/PS/2018 (REV-3), dt. 28.06.2018 & PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt:04.11.2019 (Attached) or latest. Square
Design, Manufacture, supply, fixing, testing & commissioning of double sided LED 30 type signage's of suitable size as per CEE/NR specification No. CEE/NR specification no. CEE/NR/121- Elect/PS/2018(REV-3), dt. 28.06.2018 & PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt:04.11.2019 (Attached) or latest and as per site requirement. Note:- Static / Double sided Board of different sizes name is required. Prior approval of Message, Colour and size to be taken from competent authority i.e Sr.DEE/G/MB.
B-Electrical work for Improvement of Health Unit at Laksar and other
"Supply and recessing/fixing of PVC conduit pipe with accessories, junction box etc. 1 including making chase, and plastering/clamping etc.as per technical specifications. PVC conduit pipe conforming to IS: 9537 Part-III. 1987 (Latest version) Size:25 mm dia (Medium). Note:- On ceiling/locations where provision of recess conduit is not possible then conduit will be provided on surface as per site condition and as per instruction by Rly. Representative. "
Supply of Piano type switch as per IS:3854-2023 (latest version)/Bell push as per 5 IS:4794(Part-2)-1986(latest version)/Flush type socket outlet as per IS:1293-1988(latest version) & installation on the recessed switch box including cutting of phenolic laminated sheet, connection, testing & commissioning as per technical specifications.
Supply of Batten/Angle Holder/Ceiling rose & installation with 3mm thick white Phenolic laminated sheet on the Junction Box/ Fan Box etc of laid conduit including connections, Testing & commissioning as per relevant IS and Tech. Specification and as per site requirement.
Supply & fixing of complete 18-20 watt LED, tube light fitting 1200 mm Integrated 7 with Aluminium Extrusion Base with LED & Driver, decorative pin type end caps & copper contacts with Diffuser made of transparent polycarbonate with tube light, operating voltage single phase 230 volt AC, 50 Hz conforming to CEE/NR specification No. -CEE/NR/121-Elect./PS/2018(Rev. 3) ,dated. 28.06.2018 and PCEE/NR/121-Elect/PS/2019 (Rev-4), dated 04.11.2019 or Latest.
Supply, erection, fixing, testing & commissioning of BLDC Ceiling Fan of sweep 1200 mm, Air delivery range from 210 cubic metre per minute to 220 cubic metre per minute and input 8 power consumption range from 26W to 35W ( Star Rating - 5 Star, Service Value - 6 & above cubic metre per minute per watt ) with remote for speed control of fan suitable for operation on 1 Ph, 50Hz, 240V power supply system (conform to all the performance requirements laid down in IS 374:2019 including all amendments, as applicable )
Supply,fixing,testing and commissioning of 380mm sweep,1400 rpm (approx) propeller type exhaust fan complete as per IS,IE rule & site requirement.
Supply, fixing, testing & commissioning of Main TPN Distribution Board Double Door 4 way complete with 01 No. MCCB 63/100 Amps.( 4 pole, 35 KA ) and 12 Nos. SP MCB 6-32 Amps. of 10 KA complete in all respect & as per IS technical specification & site requirement.
Design, Fabrication, Supply, Fixing and commissioning of double door IP 65 Feeder Pillar ( Size- 0.4 m.x0.4 m.x0.5 m.) made of Angle Iron size - 40x40x6 mm.covered from all sides 11 with MS Sheet 20 SWG including door with hinge, locking arrangement, nut & bolts, Aluminum Bus Bar ( Size-35x5x400 mm.), Bakelite Gutka, cable glands, Earthing points, Cement, sand, interconnections etc. and grouting with sand & cement and painting with two coats of enamel grey paint over a coat of red oxide primer for antirust complete in all respect & as per site requirement.
Earthing with 40mm dia. GI pipe class 'B' , 3 meter long, earth electrode as per IS:3043 (latest version) to achieve earth resistances less than 5 ohms including construction of 12 masonry enclosures with hinged cover plate of cast iron/RCC(Heavy Duty with lifting arrangement) with locking arrangement as required (Outer hole size: 450XmmX450mm and Cover plate(CI/RCC) size:300mmX300mm) on top, provision of earth plate, connections from earth electrode to switch gear/pole as per technical Specification/I.E. Rule.
Supply, installation, testing & commissioning of complete 60 watt LED Street light 13 fitting, operating voltage single phase 230 volt AC, 50 Hz with suitable Pressure Die Cast Aluminium Housing and LED Driver conforming to CEE/NR specification no. CEE/NR/121-Elect/PS/2018 (REV-3), dt. 28.06.2018 & PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt:04.11.2019 (Attached) or latest.
Laying, underground/road/Railway track, recessing in platform/ wall along with Rly. Track/in laid RCC/GI pipe as required 1.1KV grade LT XLPE insulated armored, aluminum conductor cable including making chase & plastering after laying of cable/digging of cable trench, sand cushioning, protective covering with second class bricks width wise, provision of cable route marker 15 as per Tech. Specification including end terminations with aluminum clamping socket/lugs lugs testing & commissioningand shall be in conformity to IS 1255 /1983 (Latest Version). Excavation shall be done complying with code of safety as per IS 3764/1992. Cable route plan should be submitted by firm for approval of C.A. before execution. Cable route marker should be attached with the laid cable through 'J' hook and display board should be above the ground.) Note: Cable will be supplied by Railway.
Provision, supply and laying by Horizontal Boring Trench less method 2.5 meter deep 16 or more as per relevant IS suitable for laying HDPE Pipe of 110 mm outer dia. with 6 mm wall thickness in the bore for laying of cable under track/road/culvert etc. Excavation shall be done complying with code of safety as per IS 3764/1992 and as per site requirement. (Supply of HDPE pipe as per IS:4984-2016 (latest version) included). Square
Design, Manufacture, supply, fixing, testing & commissioning of single sided LED type 17 signage's of suitable size as per CEE/NR specification No. CEE/NR specification no. CEE/NR/121- Elect/PS/2018(REV-3), dt. 28.06.2018 & PCEE/NR/121-Elect/PS/2019 (REV.-'4'), dt:04.11.2019 (Attached) or latest and as per site requirement. Note:- Static / Single sided Board of different sizes name is required. Prior approval of Message, Colour and size to be taken from competent authority i.e Sr.DEE/G/MB.
Design & manufacture LT switch board outdoor Typ as per IS 8623(Latest version), Supply, Installation, fixing, testing & commissioning of cubicle , floor /wall mounted type, dust & vermin proof LT Switch Board, 3 phase, 4 wire 415 volt, AC supply system. The LT Switch Board shall 18 be powder coated. The switch board shall be complete with inter connections, instrument connections with copper conductor cable, copper bus bar & front operated switchgears, Volt meter , Ampere meter Digital with Selector switch I/C with Indication lights ( lamp set.) earthing studs etc. comprising of following ie. I/C MCCB 100 Amps (35KA) 4 Pole-1 No., O/G 63 Amps MCCB ( 35KA) 4 Pole-03 Nos., 32 Amp MCB DP(10 KA)-12 Nos. complete in all respect and conforming to relevant IS and as per site requirement.
Supply, erection, fixing, testing & commissioning of Modular AC box with 32 Amps plug socket and 32 Amps. DP MCB (10 KA) complete in all respect & as per site requirement.
Supply, installation, testing & Commissioning of light weight wall mounted type Voltage Stabilizer confirming to IS : 8448 suitable with toroidal care transformer having capacity 4 20 KVA, input voltage 135 - 290 Volt and output voltage 220 - 240 Volt, MCB 32 Amps, time delay relay ( 2 - 4 min ) with soft touch type instant and start switch, under voltage and over voltage cut off with indicators. Digital Voltmeter and Ammeter with soft type selector switch for measuring input & output voltage, indicator for power ON and timer ON.
Installation, fixing, testing and commissioning of 1 to 2 ton capacity Split type AC 21 including suction / discharge copper tubing charges & ducting arrangement for waste water discharge complete in all respect & as per site requirement. (Air conditioners will be supplied by Railways).
Haridwar.Note:- Rates advertised are inclusive of GST.
Supply of FRLSH, PVC insulated multi stranded copper conductor single core cable conforming to
IS:694(latest version), and drawing in laid (recessed/surface) MS/PVC conduit pipe for wiring of
point wiring/circuit wiring/sub main/Main as required as per technical specification including
connections, testing and commissioning of following sizes:
S No. Item Description of Item Unit Qty Rate Amount
Supply & Installation of modular type switches /sockets/Fan Regulator etc. ISI marked as per
Item- 3 relevant IS on the existing moular plate & switch boxes including connections testing &
commissioning as per technical specifications of the following sizes:-
S No. Item Description of Item Unit Qty Rate Amount
1 1 Piano type Modular switch 6A(1-way) as per Numbers 250.00 149.88 37470.00
IS:3854:1997 or latest.
2 2 Plug socket modular outlet 5pin 6A as per Numbers 150.00 174.50 26175.00
IS:1293:1988 or latest.
3 3 Piano type Modular switch 16A(1-way) as per Numbers 50.00 185.72 9286.00
IS:3854:1997 or latest.
4 4 Plug socket modular outlet 3pin 6/16A as per Numbers 50.00 296.04 14802.00
IS:1293:1988(latest) with combined shuttered.
Supplying and fixing following size/ modules, GI box along with modular base & cover plate for
modular switches in recess as required of following sizes:-
S No. Item Description of Item Unit Qty Rate Amount
Laying, underground/road/Railway track, recessing in platform/ wall along with Rly. Track/in laid
RCC/GI pipe as required 1.1KV grade LT XLPE insulated armored, aluminum conductor cable
including making chase & plastering after laying of cable/digging of cable trench, sand cushioning,
protective covering with second class bricks width wise, provision of cable route marker as per
Tech. Specification including end terminations with aluminum clamping socket/lugs lugs testing &
commissioningand shall be in conformity to IS 1255 /1983 (Latest Version). Excavation shall be
done complying with code of safety as per IS 3764/1992. Cable route plan should be submitted by
firm for approval of C.A. before execution. Cable route marker should be attached with the laid
cable through 'J' hook and display board should be above the ground.) Note: Cable will be supplied
MORADABAD DIVISION-ELECTRICAL/NORTHERN RLY
S No. Item Description of Item Unit Qty Rate Amount
Schedule B-Electrical work for Improvement of Health Unit at Laksar and other misc allied
works.Note:- Rates advertised are inclusive of GST.
Supply of FRLSH, PVC insulated multi stranded copper conductor single core cable conforming to
IS:694(latest version), and drawing in laid (recessed/surface) MS/PVC conduit pipe for wiring of
point wiring/circuit wiring/sub main/Main as required as per technical specification including
connections, testing and commissioning of following sizes:
S No. Item Description of Item Unit Qty Rate Amount
Supply, fixing, testing commissioning of MS switch boxes of the following size made out of 16 SWG
MS sheet duly painted / coated with red oxide primer with egg white hylem sheet 3 mm. thick as
Item- 4 per tech. specification, ISS / IE Rules and site requirement. Hylem sheet shall be larger than MS
Boxes of following sizes:- ( NOTE :- The MS Boxes shall be with earthing bolts and hylem sheet shall
be fixed with 04 Nos. brass machine screws and washers etc.)
S No. Item Description of Item Unit Qty Rate Amount
Supply of Piano type switch as per IS:3854-2023 (latest version)/Bell push as per IS:4794(Part-2)-
1986(latest version)/Flush type socket outlet as per IS:1293-1988(latest version) & installation on
the recessed switch box including cutting of phenolic laminated sheet, connection, testing &
commissioning as per technical specifications.
S No. Item Description of Item Unit Qty Rate Amount
Laying, underground/road/Railway track, recessing in platform/ wall along with Rly. Track/in laid
RCC/GI pipe as required 1.1KV grade LT XLPE insulated armored, aluminum conductor cable
including making chase & plastering after laying of cable/digging of cable trench, sand cushioning,
protective covering with second class bricks width wise, provision of cable route marker as per
Tech. Specification including end terminations with aluminum clamping socket/lugs lugs testing &
commissioningand shall be in conformity to IS 1255 /1983 (Latest Version). Excavation shall be
done complying with code of safety as per IS 3764/1992. Cable route plan should be submitted by
firm for approval of C.A. before execution. Cable route marker should be attached with the laid
cable through 'J' hook and display board should be above the ground.) Note: Cable will be supplied
S No. Item Description of Item Unit Qty Rate Amount
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .