REPAIR / MAINT AND SERVICING OF PUMPING SET OF PUMP HOUSE AND STP, FILTER BEDS, WATER FILTERATION PLANT, CLEANING OF UG TREATED WATER POND AT LGJ MIL STN
2020_MES_317131_1
8930-34/19-20
Open Tender
Civil Works
Item Rate
180 days
GE Lalgarh Jattan
Class E Cat (b) (i)
8 documents required · 8 mandatory
₹500
GE Lalgarh Jattan
₹30,000
Yes
GE Lalgarh Jattan
4 Mar 2020
21 Jan 2020
15 Feb 2020
21 Jan 2020
12 Feb 2020
4 Feb 2020
23 Jan 2020
Amount
M & L for Cleaning of inner surface of over head Reservior 40000 Gallon capacity (Location - GE Office) manually by trained and skilled manpower for working in over head reservoir with suitable T&P and equipments with safety measure, draining out the contaminated muddy water from the bottom surface of over head reservior then clean the side walls with the help or wire brush, including removal green fungs leaves and other dust and dirt, scraping of dissolved impurities face, removal of surface mud/ silt then clean with water and drainning out complete unwanted material obtained from cleanning as well as apply disinfictant chemical safe for human being on inner surface of the tank, writing the dates with synthetic enamel paint on outer side of tank surface where ever directed complete all as specified and as directed by Engineer-in-Charge. Note for Serial item No 1 to 5 :- (i) Contractor will be responsible for insurance of his works as working at height and all arrangement for approching In the tank and safety measures. (ii) Cleaning arrangement shall be done in such a manner that routine water supply would not disturbed. (iii) Contractor will responsinble to stop & reopen supply to the tanks during cleaning period.
M & L for cleaning of inner surface of over head Reservoir 50000 Gallon capacity (Location - Officer Accn) manually by trained and skilled manpower for working in over head reservior with suitable T&P and equipments with safety , draining out the contaminated muddy water from the bottom surface of over head reservior then clean the side walls with the help or wire brush, including removal green fungs leaves and other dust and dirt, scraping of dissolved impurities face, removal of surface mud/silt then clean with water and drainning out complete unwanted material obtained from cleanning as well as apply disinfictant chemical safe for human being on inner surface of the tank writing the date with synthetic enamal paint on outer side of tank surface where ever directed complete all as specified and as directed by Engineer-in-Charge. Note :- Contractor will be responsible for insurance of his works as working at height and all arrangement for approching In the tank and safety measures.
M & L for Cleaning of inner surface of over head Reservior 100000 Gallon capacity (Location - 24 Mech Unit) manually by trained and skiled manpower for working in over head reservior with suitable T&P and equipments with safety, draining out the contaminated muddy water from the bottom surface of over head reservior than clean the side walls with the help or wire brush, including removal green fungs leaves and other dust and dirt, scraping of dissolved impurities face, removal of surface mud/silt then clean with water and drainning out complete unwanted material obtained from cleanning as well as apply disinfictant chemical safe for human being on inner surface of the tank, writing the date with synthetic enamal paint on outer side of tank surface where ever complete all as specified and as directed by Engineer-in-Charge. Note :- Contractor will be responsible for insurance of his works as working at height and all arrangement for approching In the tank and safety measures.
M & L for Cleaning of inner surface of over head Reservior 200000 Gallon capacity (Location - KSP Petrol Pump and 2 Mech Unit) manually by trained and skilled manpower for working in over head reservior with suitable T&P and equipments with safety, Draining out the contaminated muddy water from the bottom surface of overhead reservior than clean the side walls with the help or wire brush, including removal green fungs leaves and other dust and dirt, scraping of dissolved impurities face, removal of surface mud / silt than clean with water and drainning out complete unwanted material obtained from cleanning as well as apply disinfictant chemical safe for human being on inner surface of the tank writing the date with synthetic enamal paint on outer side of tank surface whereever directed complete all as specified and as directed by Engineer-in-charge. Note :- Contractor will be responsible for insurance of his works as working at height and all arrangement for approching In the tank and safety measures.
M & L for cleaning of inner surface of Underground Sump Reservior 75000 Gallon capacity (Location - Filteration Plant) manually trained and skilled manpower for working in Underground sump resrvior with suitable T&P and equipments with safety, Draining out the contaminated muddy water from the bottom surface of overhead reservoir than clean the side walls with the help or wire brush, including removal green fungs leaves and other dust and dirt, scraping of dissolved impurities face, removal of surface mud / silt then clean with water and drainning out complete unwanted material obtained from cleanning as well as apply spray of suitable disinfictant chemical safe for human being on inner surface of the tank, writing the date with synthetic enamal paint on outer side of tank surface where ever directed complete all as specified and as directed by Engineer-in-charge. Note :- Contractor will be responsible for insurance of his works and all arrangement for approching In the reservoir and safety measures.
M & L for cleaning of inner surface of Underground sump Reservior 100000 Gallon capacity (Loction - Filteration plant) manually trained and skilled manpower for working in Underground sump resrvoir with suitable T&P and equipments with safety, draining out the contaminated muddy water from the bottom surface of overhead reservoir than clean the side walls with the help or wire brush, including removal green fungs leaves and other dust and dirt, scraping of dissolved inprities face, removal of surface mud/ silt then clean with water and drainning out complete unwanted material obtained from cleanning as well as apply spray of suitable disinfictant chemical safe for human being on inner surface of the tank, writing the date with synthetic enamal paint on outer side of tank surface where ever directed complete all as specified and as directed by Engineer-in-charge. Note :- Contractor will be responsible for insurance of his works and all arrangement for approching In the reservoir and safety measures.
M & L for Cleaning of open interconnected channel of raw water tanks at GE Complex / Old Filteration Plant and Sadul Minor Canal by excavating in trenches, n. exc1.5 mtr wide and n. exc 1.5 mtr in depth for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 Sqm on plan and n exc 1.5 mtr in depth and getting out soft/loose soil and removing excavated material n exc. 50 mtr and depositing where directed at a level n exc. 1.5 mtr complete all as specified and directed by Engineer-in-Charge.
M&L for dewatering of raw water intake tank 2.5 LG of size 41x22x4 mtr at (GCPH) with pump set and manually removal of complete dirt/sludge/silt of average depth 0.2 mtr from the tank approximate 180 Cum sludge /silt etc and depositing where directed at a distance not less than 50 mtr from the tank. The work include scraping the side walls and bottom of tank including removal of plants etc from inside of the tank and cutting and removal of grass, shurb bushes etc from 3 mtr around the external walls of the tank inculding transportation charge complete all as specified and as directed by Engineer-in-Charge. Note for Serial item No. 8 & 9 :- (i) Any damagae caused to the tank during cleaning shall be made good by the Contractor with out any extra cost.(ii) For cleaning of the tank equipment and manpower shall be employed by the Contractor in such a manner that cleaning in all respect with in 10 days of issue of Job/Supply order.(iii) The contractor shall take the necessary arrangement to block the incomming water to sludge tank before starting the work and opening the same after cleaning the tank without any extra payment.(iv) No extra payment will be made for transportation of pumping set or any other machinary required the above work .(v) Contractor will be sole responsible for dewatering apart from foot valve, transportation of obtained mud, T & P required and other safety measures in respect of above work without any extra payment.(vi) Trimming, cutting, uprooting and removing of trees/bushes/ beeds/roots/vegetable growth etc upto 5m surrounding area and inside the tank floor embarcement and making good disturbed surface also included in the job.
M&L for dewatering of Raw water intake tank 2.0 LG of size 30x30x4m at (GCPH) with pump set and manually removal of complete dirt/sludge/silt of avarage depth 0.35 mtr from the tank approximate 216 Cum sludeg/silt etc and depositing where directed at a distance not less than 50 mtr from the tank. The work include scraping the side walls and bottom of tank including removal of plants etcd from inside of the tank and cutting and removal of grass, shurb bushes etc from 3 Mtr around the external walls of the tank inculding transportation charge complete all as specified and as directed by Engineer-in-charge.
M & L for cleaning of raw water tank (Capacity 10 LG) by means of dewatering the water, desilting and removing the muddy water (average 0.1 mtr depth ) to a distance not less than 50 mtr and not exceeding 100 mtr from the raw/sludge water tank, making dry the side wall and bottom, cleaning the walls & bottom with fresh water, stackings the bushes & branches of plants and removing not exceeding 20 mtr from the bank of reservoir including cleaning of adjoining area upto 5 mtr along the four sides of raw water tank complete all as specified and directed by Engineer-in-Charge.
Taking down carefully defective/burnt out electric driven Motor Centrifugal pumping set of 75 HP capacity Kirloskar make from its base duly disconnect the electrical and mechanical connections and isolate the defective motor from pumping set, transport the same to civil workshop, dismantling/opening the motor and rectifying the defective spare parts and taking out the burnt out stator winding. Clenaing the slots and complete servicing the motor, re-winding the stator with suitable size of super enamelled copper winding conductor including insulating materials varnishing the re-wind stator and heating same on heating chamber till to achieve the satisfactorly result. Re-assembling the same after replacement relevent spares like cooling fan and existing ball bearing including testing the same at workshop. Transport the same to site and reconnect all disconected connections including mounting and recoupled with respective pumps and base plate, inlcuding complete paitning with approved paint complete all as specified and directed by Engineer-in-Charge.
Taking down carefully defective/burnt out electric driven Motor Centrifugal pumping set of 50 HP capacity Kirloskar make from its base duly disconnect the electrical and mechanical connections and isolate the defective motor from pumping set, transport the same to civil workshop, dismantling/opening the motor and rectifying the defective spare parts and taking out the burnt out stator winding, clenaing the slots and complete servicing the motor, re-winding the stator with suitable size of super enamelled copper winding conductor including insulating materials varnishing the re-wind stator and heating same on heating chamber till to achieve the satisfactorly result. Re-assembling the same after replacement relevent spares like cooling fan and existing ball bearing including testing the same at workshop, transport the same to site and reconnect all disconected connections including mounting and recoupled with respective pumps and base plate, inlcuding complete paitning with approved paint complete all as specified and directed by Engineer-in-Charge.
Taking down carefully defective/burnt out electric driven motor Centrifugal pumping set of 25 HP capacity Kirloskar make from its base duly disconnect the electrical and mechanical connections and isolate the defective motor from pumping set, transport the same to civil workshop, dismantling/opening the motor and rectifying the defective spare parts and taking out the burnt out stator winding, Clenaing the slots and complete servicing the motor, re-winding the stator with suitable size of super enamelled copper winding conductor including insulating materials varnishing the re-wind stator and heating same on heating chamber till to achieve the satisfactorly result re-assembling the same after replacement relevent spares like cooling fan and existing ball bearing including testing the same at workshop, transport the same to site and reconnect all disconected connections including mounting and recoupled with respective pumps and base plate, inlcuding complete paitning with approved paint complete all as specified and directed by Engineer-in-Charge.
Taking down carefully defective/burnt out electric driven Motor Centrifugal pumping set of 15 HP capacity (Kirloskar make ) from its base duly disconnect the electrical and mechanical connections and isolate the defective motor from pumping set, transport the same to civil workshop, dismantling/opening the motor and rectifying the defective spare parts and taking out the burnt out stator winding, clenaing the slots and complete servicing the motor, re-winding the stator with suitable size of super enamelled copper winding conductor including insulating materials varnishing the re-wind stator and heating same on heating chamber till to achieve the satisfactorly result, re-assembling the same after replacement relevent spares like Cooling fan and existing ball bearing including testing the same at workshop, transport the same to site and reconnect all disconected connections including mounting and recoupled with respective pumps and base plate, inlcuding complete paitning with approved paint complete all as specified and directed by Engineer-in-Charge.
Taking down carefully defective/burnt out electric driven Motor Centrifugal pumping set of 10 HP capacity (Make : Kirloskar) from its base duly disconnect the electrical and mechanical connections and isolate the defective motor from pumping set, transport the same to civil workshop, dismantling/opening the motor and rectifying the defective spare parts and taking out the burnt out stator winding, clenaing the slots and complete servicing the motor, re-winding the stator with suitable size of super enamelled copper winding conductor including insulating materials varnishing the re-wind stator and heating same on heating chamber till to achieve the satisfactorly result, re assembling the same after replacement relevent spares like Cooling fan and existing ball bearing including testing the same at workshop, transport the same to site and reconnect all disconected connections including mounting and recoupled with respective pumps and base plate, inlcuding complete paitning with approved paint complete all as specified and directed by Engineer-in-Charge.
Taking down carefully defective/burnt out electric driven Motor Centrifugal pumping set of 5 HP capacity ( Make : KIrloskar) from its base duly disconnect the electrical and mechanical connections and isolate the defective motor from pumping set, transport the same to civil workshop, dismantling/opening the motor and rectifying the defective spare parts and taking out the burnt out stator winding, clenaing the slots and complete servicing the motor, re-winding the stator with suitable size of super enamelled copper winding conductor including insulating materials varnishing the re-wind stator and heating same on heating chamber till to achieve the satisfactorly result, re-assembling the same after replacement relevent spares including testing the same at workshop, transport the same to site and reconnect all disconected connections including mounting and recoupled with respective pumps and base plate, inlcuding complete paitning with approved paint complete all as specified and directed by Engineer-in-Charge.
Disconnecting, dismantling the air blower of capacity 230 CFM, 10 HP, 1030 RPM carry to civil workshop for Overhauling/ Servicing including dismantling motor & blower changing 'V' belts, air filter, oil filter, safety valves, oil seal and pressure gauge etc as per existing size greasing the all moving parts and bring back to installation, fixing of motor in existing foundation with proper alignment, making the same functional, testing on full load and commissioning complete all as specified and directed by Engineer-in-Charge.
Disconnecting, dismantling the air blower of capacity 3.11 CFM, 15 HP, 1400 RPM carry to civil workshop for overhauling/servicing including dismantling motor & blower changing 'V' belts, air filter, oil filter, safety valves, oil seal and pressure gauge etc as per existing size greasing the all moving parts and bring back to installation, fixing of motor in existing foundation with proper alignment , making the same functional, testing on full load and commissioning complete all as specified and directed by Engineer-in-Charge.
Taking down carefully defective/burnt out electric driven Motor Submersible pumping set of 15HP/9.5 KW Modle No KRUK-100-260/74 having capacity 88 Cum/hr at 17.5 mtr head (Make : Kirloskar) from its collection well aprox 10 mtr deep inculding disconnecting delivery pipe 100 mm bore and electric connection by using chain pulling lock and other T&P required, transport the same to civil workshop, dismantling / opening the motor and rectifying the defective spare parts and taking out the burnt out field winding, clenaing the slots and complete servicing the motor, re-winding the stator with suitable size of super enamelled copper winding conductor including insulating materials varnishing the re-wind stator and heating same on heating chamber till to achieve the satisfactorly result, re-assembling the same after replacement necessary spares like water seal, multi-core opeating copper cable of existing size & specification not exceeding 10 mtr length including testing the same at workshop, transport the same to site and lowering refixing in sewage well and making electic connection and testing complete to the entire satisfaction of Engr-in-Charg
Taking out centrifugal pump 75 HP Capacity from its foundation duly decoupling the section and delivery lines, transporting the pump to civil workshop, dismantling and strip opening the complete pump and sort out the defective spares cleaning/serviceing the pump by replacement of defective spares like Brass Bush-02 Nos, Ball Bearing of existing size-02 Nos, GI Impeller- 01 No, Rubber for Coupling - 01 No, shaft and impeler keys, Gland cup and studes, Foundation/Pumps nuts, bolts & studes of existing size and other packing material, greasing, all spares, necessary lathe machinary, reaming work for studes and welding work, painting of pumps with two coat of synthetic enamelled approved paints after preparation of old painted surfaces of pump set, refixing and alignment with motor on its original location including testing complete all as specified and directed by Engineer-in-Charge.
Taking out centrifugal pump 50 HP Capacity from its foundation duly decoupling the section and delivery lines, transporting the pump to civil workshop, dismantling and strip opening the complete pump and sort out the defective spares cleaning/serviceing the pump by replacement of defective spares like Brass Bush-02 Nos, Ball Bearing of existing size-02 Nos, GI Impeller- 01 No, Rubber for Coupling-01 No, shaft and impler keys, Gland cup and studes, Foundation/Pumps nuts, bolts & studes of existing size and other packing material, greasing, all spares, necessary lathe machinary, reaming work for studes and welding work, painting of pumps with two coat of synthetic enamelled approved paints after preparation of old painted surfaces of pump set, refixing and alignment with motor on its original location including testing complete all as specified and directed by Engineer-in-Charge.
Taking out centrifugal pump 25 HP Capacity from its foundation duly decoupling the section and delivery lines, transporting the pump to civil workshop, dismantling and strip opening the complete pump and sort out the defective spares cleaning/serviceing the pump by replacement of defective spares like Brass Bush-02 Nos, Ball Bearing of existing size-02 Nos, GI Impeller- 01 No, Rubber for Coupling-01 No, shaft and impler keys, Gland cup and studes, Foundation/Pumps nuts, bolts & studes of existing size and other packing material, greasing, all spares, necessary lathe machinary, reaming work for studes and welding work, painting of pumps with two coat of synthetic enamelled approved paints after preparation of old painted surfaces of pump set, refixing and alignment with motor on its original location including testing complete all as specified and directed by Engineer-in-Charge.
Taking out centrifugal pump 15 HP Capacity from its foundation duly decoupling the section and delivery lines, transporting the pump to civil workshop, dismantling and strip opening the complete pump and sort out the defective spares cleaning/serviceing the pump by replacement of defective spares like Brass Bush-02 Nos, Ball Bearing of existing size-02 Nos, GI Impeller- 01 No, Rubber for Coupling-01 No, shaft and impler keys, Gland cup and studes, Foundation/Pumps nuts, bolts & studes of existing size and other packing material, greasing, all spares, necessary lathe machinary, reaming work for studes and welding work, painting of pumps with two coat of synthetic enamelled approved paints after preparation of old painted surfaces of pump set, refixing and alignment with motor on its original location including testing complete all as specified and directed by Engineer-in-Charge.
Taking out monoblock pump 10 HP Capacity from its foundation duly decoupling the suction and delivery lines, transporting the pump to civil workshop, dismantling the complete pump and sort out the defective spares cleaning/serviceing the pump by replacement of defective spares like Brass Bush-02 Nos, Ball Bearing of existing size-02 Nos, Stainless steel shaft - 01 No, Gland plate and packing, nuts, bolts & studes of existing size and other packing material, greasing, all spares, necessary lathe and welding work, painting of pumps with two coat of synthetic enamelled approved paints after preparation of old painted surfaces of pump set, refixing and alignment with motor on its original location including testing complete all as specified and directed by Engineer-in-Charge.
Taking out monoblock pump 5 HP Capacity from its foundation duly decoupling the suction and delivery lines, transporting the pump to civil workshop, dismantling the complete pump and sort out the defective spares cleaning/serviceing the pump by replacement of defective spares like Brass Bush-02 Nos, Ball Bearing of existing size-02 Nos, Stainless steel shaft - 01 No, Gland plate and packing, nuts, bolts & studes of existing size and other packing material, greasing, all spares, necessary lathe and welding work, painting of pumps with two coat of synthetic enamelled approved paints after preparation of old painted surfaces of pump set, refixing and alignment with motor on its original location including testing complete all as specified and directed by Engineer-in-Charge.
Earthing complete with galvanised steel earth plate electrode 60×60cm× 6mm thick, buried directly in ground (earth pit not less than 2.25 mtr deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connected to earthing galvanised iron strip 25×4mm as earthing lead means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No 5 connected to earthing test point all as specified or indicated including testing, excavation returnfilling, removal, GI tube 20mm dia, MS deformed bar 6 to 8 mm dia (10x0.50x617) and plastering work complete all as specified and directed by Engineer-in- Charge.
Taking out Gear Box of Chlorifluoculator from its foundation duly decoupling with motor, Transporting the Gear Box to civil workshop, dismantling the complete Gear Box and sort out the defective Gears & pinion with keys and spares cleaning/overhauling the Gear Box by repair/renewal of defective Gears with keys with same gear ratio thickness and tooth profile as old, V belt, existing ball bearing, nuts, bolts & studes of existing size, gear oil, oil seal and other packing material, necessary lathe and welding work, painting two coat of synthetic enamelled approved paints after preparation of old painted surfaces of pump set, refixing and alignment with motor on its original location including testing complete all as specified and directed by Engineer-in-Charge. Note :- The Scope of work deemed to be inclusive all minor spares parts necessary to make the machine in satisfactory work order.
S &F in replacement of 150 mm Flanged non return Valve PN-1.6 with all necessary arrarngement of disconnection of section pipe lines and after replacement reconnection the same complete all as specified and directed by Engineer-in-Charge.
S &F in replacement of 100 mm Flanged non return Valve PN-1.6 with all necessary arrarngement of disconnection of suction pipe lines and after replacement reconnection the same complete all as specified and directed by Engineer-in-Charge.
M & L for Fabrication and replacemetn of rusted LT panel doors as per sample including painting and fixing with hinges complete all as specified and directed by Engineer-in-Charge.
Removing /Scraping of rusted LT panels, preparation of surface for painting of LT panels with one coat of red oxide and two coats of synthetic enemal paint complete all as specified and directed by Engineer-in-Charge.
S & F thermal overload protection relays 7.0 to 10.0A, for power contractors of different ratings including HSN Code : 8536 necessary cutting and sloating work in existing panel for fixing a complete all as specified and directed by Engineer-in-Charge
,----ditto---, all as per serial item no. 32 above, but 12.0 to 18.0A complete all as specified and directed by Engineer-in-Charge
,----ditto---, all as per serial item no. 32 above, but 17.0 to 25.0A complete all as specified and directed by Engineer-in-Charge
,----ditto---, all as per serial item no. 32 above, but 30.0 to 40.0A complete all as specified and directed by Engineer-in-Charge
,----ditto---, all as per serial item no. 32 above, but 63.0 to 80.0A complete all as specified and directed by Engineer-in-Charge
,----ditto---, all as per serial item no. 32 above, but 80.0 to 93.0A complete all as specified and directed by Engineer-in-Charge
S & F in repair 3 pole power contactors, AC3 Rating 25 A HNS Code : 8536 Type MO, size Fr-275, Cat No - CS94574 confirms to IS/IEC 60947-4-1 IEC60947-4-1, range fom 9A-300A AC-3, range 140A-300A available with conventional /AC/DC electronic coil version, built in surge supperssor, common coil for 50 & 60 Hz application, low pick up VA consumption, standardize accessories for 9A-110A and 140A-300A range, compact dimension saving panel space lug less termination all as specified and directed by Engineer-in-Charge. Make : L&T
,----ditto---, all as per serial item no. 38 above, but AC3 Rating 70 A complete all as specified and directed by Engineer-in-Charge
,----ditto---, all as per serial item no. 38 above, but AC3 Rating 95 A complete all as specified and directed by Engineer-in-Charge
,----ditto---, all as per serial item no. 38 above, but AC3 Rating 110 A complete all as specified and directed by Engineer-in-Charge
M & L for writing SM Numberes on machinary and equipments in letters or figures (Block, Roman, Italic or Indian) n exc. 30 cm high complete all as specified and directed by Engineer-in-Charge.
M & L for writing stops, commas, short lines, dashes, hyphens, brackets, etc in SM Number all as specified and directed by Engineer-in-Charge.
S & F Mild Steel screw bolts size 11 to 15 mm (machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut, n exc 5cm long complete all as specified and directed by Engineer-in-Charge :-
,----ditto---, all as per serial item no. 44 above, but size 16 to 20 mm complete all as specified and directed by Engineer-in-Charge
M & L in replacement pressure gauge 4" dial 0-14 Kgs rating all as specified and directed by Engineer-In-Charge. Make : Febig, Guru etc
M & L for XLPE insulated, armoured heavy duty electric cable 25 Sqmm, with aluminium conductor, 1100 V grade of different cross-sectional area 3.5 Core inculding necessary thimbles complete all as specified and directed by Engineer-in-Charge :-
,----ditto---, all as per serial item no. 47 above, but size 35 Sqmm complete all as specified and directed by Engineer-in-Charge
,----ditto---, all as per serial item no. 47 above, but size 50 Sqmm complete all as specified and directed by Engineer-in-Charge
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for foundations, shafts, wells, cesspits, manholes, laying pipe line, laying of cables or fixing poles and stays and struts etc. not exceeding 10 Sqm on plan and not exceeding 1.5 metre in depth and getting out in soft/loose soil including trimming the sides and forming bottom surfaces to required levels complete all as specified and as directed by Engineer-in-charge.
Removing the excavated material (surplus soil) upto a distance n.exc 50 mtr & depositing where directed a level n.exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge.
Returning & filling in including sprading levelling, watering & well ramming in layers n.exc.1.5 mtr above starting point in soil complete all as specified and directed by Engineer-in-Charge.
M&L for natural dry sand cushioning for cable protection complete all as specified and directed by Engineer-in-Charge.
Supply and laying best quality locally availble Sub class 'B' bricks (old size) for cable protection cover, laid flat and lay in trenches over TGE cable complete all as specified and directed by Engineer-in-Charge.
S & F in repair MCCB 3 Pole, 415 V adjustable type, 200 Amps with breaking capacity 36 KA including necessary modification for fixing and thimbles as required complete all as specified and directed by Engineer-in-Charge.
S & F in repair MCCB 3 Pole, 415 V fixed type, 25 to 100 Amps with breaking capacity 16 KA including necessary modification for fixing and thimbles as required complete all as specified and directed by Engineer-in-Charge.
S & F current transformer coils for different current rating in motor starter panels complete all as specified and directed by Engineer-in-Charge. Note:- The contract sum shall be calculated by deducting the amount shown in Credit Schedule attached to this tender, from total amount of Schedule 'A'/BOQ
Soma Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .