GE Satwari
GE Satwari Jammu
REPAIR/MAINT OF DG SETS STP SIGN BOARD AND CONNECTED ITEMS AT MH AND RAIPUR SATWARI UNDER OF GE SATWARI
2023_MES_621860_1
GEJM-62/2023-24
Open Tender
Civil Works
Item Rate
180 days
GE Satwari
E Class Cat b i
9 documents required · 9 mandatory
₹500
GE Satwari
₹49,800
Yes
20 Jan 2024
12 Oct 2023
11 Nov 2023
12 Oct 2023
9 Nov 2023
27 Oct 2023
Amount
Compressive repair and maintanance of DG set capacities 20 KVA to 125 KVA installed in Ridge Area, Roulki area, Raipur Satwari and Satwari Militaty Station, Diesel Generator sets including connected Alternator carrying out routine maintenance of the engine complete for smooth functioning all as per manufacturer's instructions and as directed. NOTES:- (i) Repair and Maintanance of DG set alongwith connected Alternator and Panel Board including Engine shall be carried out and rectifying the defects by replacing the following unserviceable spare parts as directed by the Engineer-in-Charge and the Contractor shall carry out monthly inspections during the maintenenace period as authorised dealer and he shall be responsible for the smooth functioning of the DG set for a period upto completion from the date of service and also attend all the maintenance works as and when required in that period except in case of major repairs. (ii) Spare parts required for replacement during the maintenance period shall be measured and paid separately at supply only rates and cost of labour for fixing these spares shall be deemed to be inluded in the rate quoted for this item. (iii) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item. (iv) Control switches such as MCCB, Main switch, contactors, multi display meter and engine control unit shall be out of scope of the item of work and the rate quoted shall exlusive of servicing/ maintenance of the above said fittings.
Compressive repair and maintanance of DG set capacities 325 KVA to 625 KVA installed in 166 MH Satwari Military station, Diesel Generator sets including connected Alternator carrying out routine maintenance of the engine complete for smooth functioning all as per manufacturer's instructions and as directed. NOTES:- (i) Repair and Maintanance of DG set alongwith connected Alternator and Panel Board including Engine shall be carried out and rectifying the defects by replacing the following unserviceable spare parts as directed by the Engineer-in-Charge and the Contractor shall carry out monthly inspections during the maintenenace period as authorised dealer and he shall be responsible for the smooth functioning of the DG set for a period upto completion from the date of service and also attend all the maintenance works as and when required in that period except in case of major repairs. (ii) Spare parts required for replacement during the maintenance period shall be measured and paid separately at supply only rates and cost of labour for fixing these spares shall be deemed to be inluded in the rate quoted for this item.(iii) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item. (iv) Control switches such as MCCB, Main switch, contactors, multi display meter and engine control unit shall be out of scope of the item of work and the rate quoted shall exlusive of servicing/ maintenance of the above said fittings.
Supply only in replacement of battery terminal for 12 volt as per existing model complete all as specified and directed.
Supply only in replacement of battery cable for 12 volt 130 AH to 150 AH as per existing model complete all as specified and directed.
Supply only of battery terminal gel complete all as specified and directed.
Supply only in replacement of Benjo bolts of suitable size as per existing model complete all as specified and directed.
Supply only in replacement of fuel pipe filter as per existing model complete all as specified and directed.
Supply only in replacement of Voltage Regulator (AVR) suitable for DG set of capacity 325 KVA to 625 KVA as per existing model complete all as specified and directed.
Supply only in replacement of Voltage Regulator (AVR) suitable for DG set of capacity 62.5 KVA to 125 KVA as per existing model complete all as specified and directed.
Supply only in replacement of Voltage Regulator (AVR) suitable for DG set of capacity 50/45/40/20 KVA as per existing model complete all as specified and directed.
Supply only in replacement of Low Oil pressure Switch 12V 1.7 kg/Sq.mm as per existing model complete all as specified and directed.
Supply only in replacement of copper cable multi stranded PVC sheathed size 25 sqmm single coreas per existing model complete all as specified and directed.
Supply only in replacement of stopping solenoid 24 Volt suitable for the DG set of capacity 325 KVA capacity to 625 KVA as per existing model complete all as specified and directed
Supply only in replacement of stopping solenoid 12 Volt suitable for DG set of capacity 82 KVA capacity to 125 KVA as per existing model complete all as specified and directed.
Supply only in replacement of stopping solenoid 12 Volt suitable for DG set of capacity 7.5 KVA capacity to 62.5 KVA as per existing model complete all as specified and directed.
Supply & only in replacement of Air cleaner filter for Genset of any capacity and model as per existing model complete all as specified and directed.
Supply only in replacement of hoses pipe as per existing size and model with clamp as per existing model complete all as specified and directed.
Supply only in replacement of lube pipe as per existing model complete all as specified and directed.
Supply only in replacement of DC Ammeter of Range 0-10 A as per existing model complete all as specified and directed.
Supply only in replacement of Lube oil pressure gauge electronic type of suitable range as per existing model complete all as specified and directed.
Supply only in replacement of fan belts for replacement of u/s fan belts of following capacities of DG set as per sample size all as directed, Make: Fenner/Dunlop. a) DG set of capacity 325 KVA to 625 KVA
b) DG set of capacity 82.5 KVA to 125 KVA
c) DG set of capacity 40 KVA capacity to 62.5 KVA
d) DG set of capacity 20 KVA 25 KVA
Supply only in replacement of Radiator Water Pump of any capacities of DG set as per existing model/sample size all as specified and directed.
Supply only in replacement of pulley for fan belts of any capacities of DG set 63 KVA to 625 KVA as per existing model/sample size all as specified and directed,
Maintenance and servicing of following mentioned Diesel Generator Sets including connected Alternator and carrying out routine 'B' check of the engine complete for smooth functioning all as per manufacturer's instructions and as directed. Note :- (i) Control switches such as MCCB, Main switch, contactors, multi display meter and engine control unit shall be out of scope of the item of work and the rate quoted shall exlusive of servicing/ maintenance of the above said fittings. (ii) 'B' check shall be carried out once in every six months or 500 hours of running of DG Set whichever is earlier. Servicing of DG Set alonwith connected Alternator and Panel Board of the Engine shall also be carried out as directed by the Engineer-in-charge and the Contractor shall carry out periodical inspections during the maintenance period and he shall be responsible for the smooth functioning of the DG Set for a period of contract from the date of service and shall also attend all the maintenance works as and when required in that period except in case of Major repairs. (iii) Spare parts, engine oil and radiator coolant oil required for replacement during the maintenance period shall be measured and paid seperately at supply only rates and cost of labour for fixing these spares/filling of oils shall be deemed to be included in the rate quoted for this item. (iv) Cost of all consumables required during the maintenance period shall be deemed to be included in the rate quoted for this item. (v) List of checks to be carried out under 'B' check is attached as Appendix 'B' to the Particular specifications. a) 625 KVA capacity at AC Plant MH
b) 500 KVA capacity at166 MH New BLDG
c) 400 KVA capacity at AC Plant OT
d) 325 KVA capacity at 166 MH Old Bldg
e) 125 KVA capacity at Pump House No 04, Pump House 06, Ridge Pump House, Roulki Pump House, Single Center, Raipur Satwari
g) 82 KVA capacity at WEU Pump House
f) 62.5/63 KVA capacity at ICU AC Plant, Pump house No 02, Pump House No 14, Pump House No 12, Pump House No 03, Pump House No 01, Pump House No 05, Pump House No 07, Pump House No 10, Pump House No 13, Pump House No 15, Pump House No 17, CFL ASC Ridge, Peeru vihar (STP),
g) 40 KVA capacity at WEU, Pump House JDC and Children school
h) 25 KVA capacity at Pump House No 01 (water filling point) & Pump House No 16.
i) 20 KVA capacity at Atmma Dawar Gd post, Belli Chilana Gd post
Supply only Engine Oil SAE 15W-40W all as directed. Note- (i) Engine oil will be replaced in the presence of engineer-in-charge. (ii) Drain the out lived engine oil, clean the oil sump before new oil filling (iii) Filling charges considered under item here-in-before Make- Servo/Costrol/Valvoline.
Supply only set of fuel filter elements of following capacity:- a) DG Set of capacity 325 KVA to 625 KVA
b) DG Set of capacity 62.5 KVA to 125KVA
c) DG Set of capacity 20 KVA to 40 KVA
Supply only lube /engine oil filter/cartridges as per sample and make of the following capacities of DG sets. a) DG Set of capacity 325 KVA to 625 KVA
b) DG Set of capacity 62.5 KVA to 125KVA
c) DG Set of capacity 20 KVA to 40 KVA
Repair & Maintenance of radiator assy mentioned of following DG sets by disconnecting and removing from engine, dismantling the top & bottom chambers, descalling the sediments and scales, corrosion ..etc by means of acid cleanig and high pressure water washing, air cleaning, re assembling the same with new gaskets, including arresting leakage, if any and fixing to the engine with new hoses, clipes as reqd. Note : The rate qouted shall be inclusive of transporting of the radiator to the workshop and back and all incidental charges. a) DG Set of capacity 325 KVA to 625 KVA
All as per ser item No 44 above here -in- before but of DG set of capacity 62.5 KVA to125 KVA
All as per ser item No 44 above here -in- before but of DG set of capacity 20 KVA to 40 KVA
Supply only radiator coolant Make :- (Servo cool/Costrol/VOLVOLINE/IOC ) Note: Fixing charges considered under srl item No 44 here-in-before
Taking out the fuel pump and injector's from the DG set and trasporting to work shop for opening, checking, servicing and calibration of the injector pump with injectors calibration repair incl replacement of unserviceable parts, and re-fixing the same position on DG set testing complete all as directed of following capacities of DG SETS. These rates deem to be included for necessary sealing rings, "O" rings if needs replacement etc, and render necessary test servicing certificate from the authorised dealer. a) DG Set of capacity 325 KVA to 625 KVA
b) 82.5 KVA to 125 KVA DG set
c) 40 to 62.5 KVA capacity
d) DG set of capacity 20 KVA to 25 KVA
Opening the coupling, dismantling the alternator carefully removing the flywheel , dismantling the unserviceable starting gear wheel , supply and fixing new starting gear wheel of capacity 325KVA to 625 KVA , fixing back the alternator and properly coupled back all as directed.
Opening the coupling, dismantling the alternator carefully removing the flywheel , dismantling the unserviceable starting gear wheel of capacity 62.5 to 125 KVA , supply and fixing new starting gear wheel , fixing back the alternator and properly coupled back all as directed.
Opening the coupling , dismantling the alternator carefully removing the flywheel, dismantling the unserviceable starting gear wheel of capacity 20 to 25 KVA, supply and fixing new staring gear wheel , fixing back the alternator and properly coupled back all as directed.
Supply and fixing in replacement of anti vibration pad complete all as specified and directed.
Repair / maintenance of turb charger of DG set 325 KVA to 625 KVA DG Setby replacing of capaciter , turbo charger kit complete all as specified and directed by Engr In Charge.
Repair / maintenance of turb charger of DG set 82 KVA to 125 KVA DG Setby replacing of capaciter , turbo charger kit complete all as specified and directed by Engr In Charge.
Repair / maintenance of turb charger of DG set 20 KVA to 62.5 KVA DG Setby replacing of capaciter , turbo charger kit complete all as specified and directed by Engr In Charge.
Repair and maintenance of AMF panel of following capacities of DG sets 325 KVA TO 625 KVA including routing / preventive maintenance checks for trouble free functioning as reqd.(i) Checking all electrical connections. (ii) Checking all contact points / Bus bars. (iii) Checking / replace timers (AC or DC). (iii) Checking / replace buttons. (iv) Checking / replace indicator lamps. (v) Checking / replace main , auxliary contacts/relays. (vi) Checking / replace contact coils . (vii) Checking / replace ,volt /amps/energy/ PF/ KWH meters/CT's. (viii) Checking Auto / manual function. (ix) Check and tight screws and bolts. (x) Check battery charger out put voltage incl Cleaning the panel. Note : (i) All spare will be measured and paid separetly. (ii) Rutine check/preventive maintenance will be carried out by OEM/authorised dealers.iii) Contractor has to attend the breakdown at any time and place during the contract period iv) General maint is indicative only contractor has to do the necessary other maint task also as reqd. and directed by Engr-in-Charge.
Repair and maintenance of AMF panel of following capacities of DG sets 20 KVA TO 125 KVA including routing / preventive maintenance checks for trouble free functioning as reqd.(i) Checking all electrical connections. (ii) Checking all contact points / Bus bars. (iii) Checking / replace timers (AC or DC). (iii) Checking / replace buttons. (iv) Checking / replace indicator lamps. (v) Checking / replace main , auxliary contacts/relays. (vi) Checking / replace contact coils . (vii) Checking / replace ,volt /amps/energy/ PF/ KWH meters/CT's. (viii) Checking Auto / manual function. (ix) Check and tight screws and bolts. (x) Check battery charger out put voltage incl Cleaning the panel. Note : (i) All spare will be measured and paid separetly. (ii) Rutine check/preventive maintenance will be carried out by OEM/authorised dealers.iii) Contractor has to attend the breakdown at any time and place during the contract period iv) General maint is indicative only contractor has to do the necessary other maint task also as reqd. and directed by Engr-in-Charge.
Supply and fixing in replacement of GENERATOR MONITORING CONTROL PANEL of capacity 125 KVA Comprising of the following :- (a) Microprocessor based genset controller (Power Command) for metering, monitoring, governing and (b) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) over speeding of engine as per existing Make- Sudhir (c) Alternator protection parameters like under voltage, over current, under frequency, over load. (d) Relay driven for remote annunciations (e) Cyclic cranking. (f) Auto/manual start/stop (g) Alternator trim adjustment from the front key pad (h) Operates within a temperature range 0-60 degrees and humidity upto 95% (i) Remote monitoring capability through separate interface modules (j) Genset metering parameters like lube oil pressure, coolant temperature, engine speed (RPM), run hours, DC voltage, intake manifold temperature, 3 phase volts and 3 phase amperes, frequency, KW, KVA power factor etc. and also latest Model as per Manufacture instruction complete all as specified and directed.
Supply and fixing in replacement of GENERATOR MONITORING CONTROL PANEL of capacity 62.5 KVA Comprising of the following :- (a) Microprocessor based genset controller (Power Command) for metering, monitoring, governing and (b) Engine protection for low lub oil pressure, high coolant temperature (alarm & shutdown) over speeding of engine as per existing Make- Sudhir (c) Alternator protection parameters like under voltage, over current, under frequency, over load. (d) Relay driven for remote annunciations (e) Cyclic cranking. (f) Auto/manual start/stop (g) Alternator trim adjustment from the front key pad (h) Operates within a temperature range 0-60 degrees and humidity upto 95% (i) Remote monitoring capability through separate interface modules (j) Genset metering parameters like lube oil pressure, coolant temperature, engine speed (RPM), run hours, DC voltage, intake manifold temperature, 3 phase volts and 3 phase amperes, frequency, KW, KVA power factor etc. and also latest Model as per Manufacture instruction complete all as specified and directed.
Supply only in replacement of A series electronic timers on delay function model AIDI/AIDCS 12 V DC with time range 0.3S to 30 Min. Make: EAPL or equivalent suitable for panel complete all as specified and directed.
Supply only in replacement of HRC fuses of capacity 4-20 Amps complete all as specified and directed.
Supply only in replacement of HRC fuse cartidge assembly both base and top 20A rating complete all as specified and directed.
Supply only in replacement of indicator lamps DC filament type complete all as specified and directed.
Supply only in replacement of indicator lamps AC 230 Volt LED Type for the panel boards complete all as specified and directed.
Supply only in replacement of push button with contact element 5 A with NO-NC complete all as specified and directed.
Supply only in replacement of Ammeter as per sample of range 0-30/50/100 Amps AC for control/AMF panel complete all as specified and directed.
Supply only in replacement of Volt Meter as per sample of Range 0-600 Volts AC complete all as specified and directed.
Repair and maintenance of control panel for DG set of following capacities 20 KVA to 625 KVA including routine / preventive maintenance checks for trouble free functioning as reqd. The Contractor shall carry out monthly inspections during the maintenance period and he shall be responsible for the smooth functioning of the DG set control panel a period upto completion from the date of service and shall also attend all the maintenance works as and when required. Note:-(i) During the inspection/maintenance of DG set control panel repair any type of T&P/Eqpt required, rate deemed to be included in qouted rate. (ii) Spare parts required for replacement during the maintenance period shall be measured and paid separately in respective items. (iii) Minor spare parts & time delay, faulty start/any type trouble in start of DG set rate deemed to be included in qouted rate.
Supply only in replacement of printed circuit board card of battery charging unit in any cap of DG set complete all as specified and directed.
Supply only in replacement of ignition key suitable for DG set panel/control panel complete all as specified and directed.
Supply only in replacement of Energy meter 3 phase, 4 wire, 20-60 Amps range microprocessor based complete all as specified and directed..
Supply only in replacement of '' ON DELAY TIMERS (for STOP/START/LOP/LOT/FAULT etc) Time range 3 sec to 30 hours contact 5 Amps 240V/12-24 volts DC complete all as specified and directed.
Supply only in replacement of add on blocks for example 1NO,1NC complete all as specified and directed.
Supply only in replacement of control fuses PVC base and top catridge type assembly of suitable ratings for DG set control panels complete all as specified and directed.
Supply only in replacement of single phase preventer model VSP3, 415 volts AC 50 hz suitable for AMF panel complete all as specified and directed.
Supply only in replacement of Multifunction digital meter (in lieu of voltmeter, ammeter, PF meter) suitable for new version DG set control panel complete all as specified and directed.
Supply only in replacement of CT's of suitable rating for control panel/AMF panel complete all as specified and directed.
Supply only in replacement of terminals with stud 4 way suitable to be mounted for control panel/AMF Panel complete all as specified and directed.
Supply only in replacement of control MCB's SP of suitable rating for DG set control panels of suitable ratings complete all as specified and directed
Supply only in replacement of control MCB TPN 4 Pole 63A 16 KA, 415 Volts suitable for DG set control panels complete all as specified and directed.
Supply only in replacement of MCB TP 32 Amps, 16 KA, 415 Volts rating, 50 HZ complete all as specified and directed.
Supply only in replacement of Battery charger 12 V [SMPS type - 20 amps] Make : NHP of ratings 100 VA complete all as specified and directed.
Supply only in replacement of control copper cable multistrand single core of size 16 Sqmm for connecting of control Pannel to DG set of any rating complete all as specified and directed.
Opening the coupling, dismantling the self starter carefully and removing unserviceable spare parts i.e Plunger contact disc, motor feed terminal, by-pass ignition terminal, brush end plate, field brush, brush spring, ground bush, field coil, Armature, pole shoe, over running clutch, drive pinion, pivot pin, shift lever, plunger, return spring and solenoid windings, after repair fixing back the same poition of alternator and properly coupled back all as specified and directed for 325 to 625 KVA
Opening the coupling, dismantling the self starter carefully and removing unserviceable spare parts i.e Plunger contact disc, motor feed terminal, by-pass ignition terminal, brush end plate, field brush, brush spring, ground bush, field coil, Armature, pole shoe, overrunning clutch, drive pinion, pivot pin, shift lever, plunger, return spring and solenoid windings, after repair fixing back the same poition of alternator and properly coupled back all as specified and directed for 62.5 to 125 KVA
Opening the coupling, dismantling the self starter alternator carefully and removing unserviceable spare parts i.e Plunger contact disc, motor feed terminal, by-pass ignition terminal, brush end plate, field brush, brush spring, ground bush, field coil, Armature, pole shoe, overrunning clutch, drive pinion, pivot pin, shift lever, plunger, return spring and solenoid windings, after repair fixing back the same poition of alternator and properly coupled back all as specified and directed for 20 KVA to 40 KVA
Disconnecting the electrical connection from the panel and taking out unserviceable Alternator of DG set any size and capacity from the foundation of Genset and other accessories carrying to workshop for repair, after repair Alternator shifted to the existing baseframe of DG set and re installation in original position including all electrical connection testing and commissioning complete all as specified and directed. Note: Spare part measured and paid under relivent items.The cost of transportation to and from workshop is deemed to be included in the quoted rate.
M & L for opening/removing the burnt winding wire of the Genset Alternator, cleaning the slots for rewinding, and rewinding the alternator with super enamelled copper winding wire superior quality as per exisitng gauge and size, varnishing, drying, same replacement of bushes and any other spare parts required replacement of bearings and assembling the Alternator of Cap 325 KVA to 625 KVA including re-installing at site connecting and testing, commisioning complete all as specified and directed.
M & L for opening/removing the burnt winding wire of the Genset Alternator, cleaning the slots for rewinding, and rewinding the alternator with super enamelled copper winding wire superior quality as per exisitng gauge and size, varnishing, drying, same replacement of bushes and any other spare parts required replacement of bearings and assembling the Alternator of Cap 125 KVA including re-installing at site connecting and testing, commisioning complete all as specified and directed.
All as per ser item No 93 here-in-before but of capacity 40 KVA to 62.5 KVA complete.
All as per ser item No 93 here-in-before but of capacity 20 KVA to 25 KVA complete.
Repairing the Battery charging alternator/dynamo after removing from the DG set of capacity 325 KVA to 625 KVA and transporting to an auth service centre incl replacment of following parts complete all as specified and directed. (a) Armature of suitable size 1 No (b) Bearing bushes of suitable size 1 set (c) Voltage regulator of suitable size
All as per item No. 96 here-in-before but capacity of DG set 62.5 KVA to 125 KVA
All as per item No. 96 here-in-before but capacity of DG set 20/25
M&L in replacement of Copper wiring with 2.5/1.5 sqmm including necessary assessories like truf, Dins (MCB channels), lugs sleeves etc in repairs for short burnt length only.
Taking down the existing DG set defective doors and preparation of new hinges, fixing/revating as per existing and smooth functioning/moving the doors incl replacement of key/ locking arrangement complete of the capacity 325 to 625 KVA DG Set complete all as specified and directed.
All as per ser item No 100 here-in before but of capacity 62.5 KVA to 125 KVA DG Set
All as per ser item No 100 here-in before but of capacity 20 KVA to 40 KVA DG Set
Material and labour for preparation of old painted external surface by scraping the existing paint and painting the surface with the existing colour by applying one coat of synthetic enamel paint for the capacity of DG sets 325 KVA to 625 KVA complete all as specified and directed.
All as per item No.103 here-in-before but capacity of DG set 62.5 KVA to 125 KVA
All as per item No.103 here-in-before but capacity of DG set 20/25
Supply and fixing in replacement of unserviceable battery of 180 AH, 12 Volts, Make Exide power/Amron/Amco. Note: Old material taken on salvage ledger.
Supply and fixing in replacement of unserviceable battery of 150 AH, 12 Volts, Make Exide power/Amron/Amco. Note: Old material taken on salvage ledger.
Supply and fixing in replacement of unserviceable battery of 90 AH, 12 Volts, Make Exide power/Amron/Amco. Note: Old material taken on salvage ledger.
Supply and fixing in replacement of unserviceable battery of 72-74 AH, 12 Volts, Make Exide power/Amron/Amco. Note: Old material taken on salvage ledger.
Supply and fixing in replacement of battery charger having electronic circuit consisting of tridodes, rectifiers capacitors resistances etc suitable to be mounted on control panels to charge the battery of the DG set at all times whenever there is electric supply on mains or DG set supply complete all as specified and directed.
Supply and fixing in replacement of onload changeover switch 415 Volts AC, 4 poles 630 Amps, sheet metal enclosure including fixing arrangement in existing panel/on wall, including nut bolts washer's complete all as specified.
All as per Ser Item No 111 here-in-before but of capacity 250 Amps
All as per Ser Item No 111 here-in-before but of capacity 160 to 200 Amps
All as per Ser Item No 111 here-in-before but of capacity 63 to 100 Amps
Supply and fixing in replacement of MCCB 630 Amps 4 Pole 50 KA thermal and magnetic release with Ics=100%Icu, confirming to IS /IEC 60947-2 and IEC 60947-2 with short circuit and over load protection, connected with incoming/outgoing circuit shoul be provided for connected cable without any extra cost Make- Legrand or equivalent as per list of make complete all as specified and directed.
Supply and fixing in replacement of MCCB 400 Amps 4 Pole 36 KA thermal and magnetic release with Ics=100%Icu, confirming to IS /IEC 60947-2 and IEC 60947-2 with short circuit and over load protection, connected with incoming/outgoing circuit shoul be provided for connected cable without any extra cost Make- Legrand or equivalent as per list of make complete all as specified and directed.
Supply and fixing in replacement of MCCB 250 Amps 4 Pole 36 KA thermal and magnetic release with Ics=100%Icu, confirming to IS /IEC 60947-2 and IEC 60947-2 with short circuit and over load protection, connected with incoming/outgoing circuit shoul be provided for connected cable without any extra cost Make- Legrand or equivalent as per list of make complete all as specified and directed.
Supply and fixing in replacement of MCCB 200 Amps 4 Pole 36 KA Adjustable type with Ics=100%Icu, confirming to IS /IEC 60947-2 and IEC 60947-2 with short circuit and over load protection, connected with incoming/outgoing circuit shoul be provided for connected cable without any extra cost Make- Legrand or equivalent as per list of make complete all as specified and directed.
Supply and fixing in replacement of MCCB 160 Amps 4 Pole 36 KA thermal and magnetic release with Ics=100%Icu, confirming to IS /IEC 60947-2 and IEC 60947-2 with short circuit and over load protection, connected with incoming/outgoing circuit shoul be provided for connected cable without any extra cost Make- Legrand or equivalent as per list of make complete all as specified and directed.
M & L in repl of Earthing complete with galvanised steel earth plate 600 x 600 x 6mm buried directly in ground vertically to a depth not less than 2.25 mtr below normal ground level with top edge of the earth plate at a depth not less than 1.5 mtr below ground level connected to and including GI strip 25x4mm by means of nuts, bolts, washers etc made of and connected to test point and earth dolly as all shown in electrical plate No.3 of SSR Part-I 2009 and specified or indicated including excavation and earth work in any type of soil PCC (1:3:6) type C1 in chamber, pre cast RCC slab 50mm thick in cement concrete (1:2:4) type B1, reinforced with welded steel wire fabric or XPM jali (weight not less than 4.00 kg/Sqm with cast iron frame, funnel, with wire mesh, 20mm bore medium grade GI watering pipe, lugs, 15mm bore medium grade GI protection pipe, test point etc complete all as specified and directed. (Length of GI earth strip & Protection pipe is up to 7.5 RM including) Note : - If soil required in earthing shall be provided by contractor without any extra cost. No extra amount shall be given to contractor for extra earthing soil.
M & L for disconnecting 6/7.5 HP non clog submersible pumpset sewage type from the sewage sump and transporting to workshop for repair, cutting of burnt winding/cleaning of stator for rewinding with PVC insulated copper wire of existing size , providing with insulating materials, flame proof/water proof laminated insulated strips, cotton tape, complete and shifting back to site, coupling to pump and lowering in sump and testing all as specified and directed by Engr-in-charge.
M & L for disconnecting 15 HP non clog Raw water sewage transfer submersible pump from the sewage sump and transporting to workshop for repair, cutting of burnt winding/cleaning of stator for rewinding with PVC insulated copper wire of existing size , providing with insulating materials, flame proof/water proof laminated insulated strips, cotton tape, complete and shifting back to site, coupling to pump and lowering in sump and testing all as specified and directed by Engr-in-charge. Location:- MH Satwari
Supply and fixing in replacement of automatic star delta starter three phase of size 40 HP as directed by Engr-in-charge
M & L for disconnecting 5.5 KW blower motor and transporting to workshop for repair, cutting of burnt winding/cleaning of stator for rewinding with super enamelled copper wire of existing size , providing with insulating materials, flame proof/water proof laminated insulated strips, cotton tape, complete and shifting back to site, coupling to blower fan and testing all as specified and directed by Engr-in-charge. Location:- MH Satwari
M & L for dismantling of 7.5 HP air blower pump from the electric motor and re-assembling the fan on existing foundation complete with motor after repair/overhaulding with following and testing complete all as specified and directed.The cost of transportation to and fro workshop is deemed to be included in the quoted rate. Location:-MH Satwari a) Replacement of blade. b) Cleaning, dusting and spray painting of air blower with motor (complete body) externally. c) Re-metaling/turning, greasing, oiling of pump shaft. d) Replacement of oil, oil seal, bearing, filter. e) Replacement of belts and pressure gauge.
Taking out sludge from underground main sewage/drainage receiving sump and removing it to a distance not less than 150 metre incluidng scrapping off the walls and cleaning by applying bleaching powder @ 1Kg per sqm at MH Personal Line nrear, complete all as directed. Location:- MH Satwari
Cutting of wild grass ,bushes ,unwanted vegetation trees and any size and any type of trees of recieving chamber, Main chamber, storage chamber, sludge dry bed, upto 30cm grith including roots from inside/surrounding of installations including cutting of bushes along with barbed/cattle fencing of the installation comlete and all cutting tools arengenment of the contractor all as specified and directed by Engr-in-charge. Location:- MH Satwari
Taking down of existing DG set any capacity and disconnecting the electrical connection and lifting/loading on vehicles, shifting from JDC Pump House to Pump House No 13 incl to be connected as per existing system complete as specified and directed by Engineer-in-charge.
Taking down of existing DG set any capacity and disconnecting the electrical connection and lifting/loading on vehicles, shifting from Pump House No 13 to JDC Pump House incl to be connected as per existing system complete as specified and directed by Engineer-in-charge.
Supply and fixing in replacement of outdoor type LED Glo sign ticker board of size 1.5' x 6' (fit) in day night version of bright blue colour of LED letter not less than 240 with operating software and also with wifi programing projector system for input data programing working temperature range -25 degree to 85 degree protection class IP 56 along with inclouser of sheet metal board of size 22 gauge for holding of LED GLO sign board for fixing on wall including nut and bolts and all fixing arrangement with electrical connection complete all as specified and directed.
M/S PRAJAPATI ENGINEERS
M/S GULATI ENGINEERING WORKS
TARA ENTERPRISES
M/S S K Electricals Regd
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .