Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.1 LAccepted-AOC NEAR TCP DOMAIL WARD NO 2 UDHAMPUR 182101 J K | UDHAMPUR | JAMMU AND KASHMIR | 182101 | L1 | Accepted-AOC Accepted | |
| 2 | L2₹24.3 L+₹87,738 (3.74%)Rejected-AOC | L2 | Rejected-AOC Rejected |
Tender Value
₹23.5 L
EMD Value
₹47,000
Closing Date
18 Jun 2020, 6:00 pmClosed
SHUBHAM PRAKASH
GE (NORTH) UDHAMPUR
GE/U(N)-08/2020-21 SPL REPAIR TO ROOF AND ELECTRIC RE-WIRING OF COOK HOUSE AND DINING HALL BLDG NO NP-07 AND NP-08 AND CERTAIN REVENUE WORK UNDER AGE B/R-II OF GE NORTH UDHAMPUR
2020_MES_340733_2
GE/U(N)-08/2020-21
Open Tender
Civil Works
Item Rate
180 days
UDHAMPUR
CLASS E
7 documents required · 7 mandatory
₹500
GE (NORTH) UDHAMPUR
₹47,000
Yes
3 Jul 2020
28 May 2020
20 Jun 2020
28 May 2020
18 Jun 2020
4 Jun 2020
Amount
Dismantling floor, hearth or wall tiling including Cement Mortar bedding(but not backing), complete all as specified and directed by Engineer-in-Charge.
Dismantling boarding including frame etc any description fixed in any position fixed with screws or nails, complete all as specified and directed by Engineer-in-Charge.
Dismantling of Asbestos cement corrugated, semi corrugated sheets in roof covring, complete all as specified and directed by Engineer-in-Charge.
Taking down cement or cement lime plaster, any description on brick or stone walls, etc including racking out joints, hacking for key, scrubbing down with water etc, complete all as specified and directed by Engineer-in-Charge.
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) not exc 1.50sqm each and removing from site complete all as specified and directed by Engineer-in-Charge.
Taking down Chowkats or frames with shutters (without taking off shutters from the frame) exc 1.5sqm but not exc 4 sqm each and removing from site, complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 15mm dia, complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 20mm dia, complete all as specified and directed by Engineer-in-Charge.
Taking up or down steel tubing and connections, including cleaning for refixing or removal to store 25mm dia, complete all as specified and directed by Engineer-in-Charge.
Demolition of unreinforced cement concrete of any description and in any position not otherwise specifically provided and removing the demolished material from the site to a distance n. exc 500M and depositing where directed by Engineer-in-Charge.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided and removing the demolished material from side, complete all as specified and directed by Engineer-in-Charge.
Demolition of Brickwork or stone/boulder masonry, built in cement mortar or cement lime mortar including all quoins,arches,pillars,etc,but excluding ashlar facing, dressed stone work and precast concrete articles, complete all as specified and directed by Engineer-in-Charge.
Demolition of cement concrete (un reinforced) in ground floor and paving n. exe 15 cm thickness (below or above ground level), complete all as specified and directed by Engineer-in-Charge.
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in any type of soil , complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches n.exc. 1.50m deep and n.exe 1.50 in wide and getting out in any type of soil, complete all as specified and as directed by Engr-in-Charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exc 25 cm, complete all as specified and as directed by Engr-in-Charge.
Removing excavated material n exc 50 m and depositing where directed at a level n exc 1.5 m above the starting point, complete all as specified and as directed by Engr-in-Charge.
Hard core of broken stone or boulders of gauge not exc 63mm deposited, spread & levelled in layers not exc 15cm thick, including watering and ramming to a true surface complete all as specified and directed by Engineer-in-Charge. NOTE :- Volume of hard core after consolidation will be measured and paid.
Brick work with subclass ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:6) complete all as specified and directed by Engineer-in-Charge..
Brick work with subclass ‘B’ old size burnt bricks, straight or curved on plan exc 6m mean radius built in cement mortar (1:4) complete all as specified and directed by Engineer-in-Charge..
Brick work using old size bricks (EXCEPT BRICKS) straight or curved on plan exceeding 6.00 metre mean radius, built in cement mortar (1:6), complete all as specified and directed by Engineer-in-Charge.
Brick work with sub class ‘B’ bricks (old size), straight or curved on plan to any radius in half brick thick walls built in CM 1:4, complete all as specified and directed by Engineer-in-Charge.
PCC type C-2 (1:3:6), using 40 mm graded stone aggregates as in foundation filling & mass concrete, complete all as specified and directed by Engineer-in-Charge.
PCC type C-1 (1:3:6), using 20 mm graded crushed stone aggregates in surface channels and drains, complete all as specified and directed by Engineer-in-Charge.
Providing cement concrete 1:3:6 type C-0 using 12.5mm graded crushed stone aggregates for filling in the pressed steel door frame/hold fast , complete all as specified and directed by Engineer-in-Charge.
Providing Precast Cement concrete 1:2:4 type B-0 (Using 12.5 mm graded crushed stone aggregate ) as in Kerb stone set in CM 1:6, rounded or chamfered on edges, including necessary form work, complete all as specified and directed by the Engr-in-charge.
Cement concrete 1:2:4 type B1, (using 20 mm graded crushed stone aggregate) as in lintels upto 1.5m clear span, steps, seismic and other similar bands coping/cills/benching,bed plates bed block etc for embedding hold fast including necessary form work weathering, slightly rounded or chamfered angles and throating complete all as specified and directed by Engineer-in-Charge.
Precast cement concrete type B-1 (1:2:4), using 20 mm graded crushed stone aggregates as in landings, cover slabs (for manholes etc.) chullah hoods, chajjas, water troughs, mangers, shelves and similar articles with plain faces including all mouldings but excluding frame, set in cement mortar (1:4), including necessary form work, complete all as specified.
Reinforced cement concrete(design mix) M-25( using 20mm graded crushed stone aggregate) as in beams, cantilevers, bressummers, lintel over 1.5m clear span complete all as specified and directed by Engineer-in-Charge.
Reinforced cement concrete (design mix) M-25( using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies deck slabs, and in shelves and the like complete all as specified and directed by Engineer-in-Charge..
Use & waste of Form work to soffits of suspended slabs such as roof slabs, floor slabs, landing horizontal or slopping similar work not. Exc 200mm thick, and flat fair finished surfaces complete all as specified and directed by Engineer-in-Charge.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide
Cutting holes into or through brick walls/stone walls built in cement mortar or cement concrete walls superficial area n. exc 150 sqcm and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l as required
Factory made, 2nd class hard wood rail and style 35 mm thick, plain framed, panelled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered partical board with commercial veneering on both sides. The size of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, complete all as specified and directed by Engineer-in-Charge.
All as per item above but glazed and skeleton shutter with sash bar for glass / wire gauge, complete all as specified and directed by Engineer-in-Charge.
Aluninum anodised bolts barrels tower bolts with bright both 150mm long, complete all as specified and directed by Engineer-in-Charge.
Alunminium handle cost type 150mm long oval type, complete all as specified and directed by Engineer-in-Charge.
Aluminium extruded section hydraulically door closer regulated designation no-1 universal type suitable for door shutter upto 700mm in width & of weight not more than 35 kg , complete all as specified and directed by Engineer-in-Charge.
Pressed steel frames, conforming to IS, having profile 125 mm x 60 mm for doors with one or more rebates made out of 1.25 mm thick mild steel sheet, including necessary fixing lugs, butt hinges, lock strike plate, etc., complete, as specified, supplied and fixed with one shop coat of zinc chromate primer, complete all as specified and directed by Engineer-in-Charge.
Pressed steel frames, conforming to IS, having profile 105 mm x 60 mm for doors with one or more rebates made out of 1.25 mm thick mild steel sheet, including necessary fixing lugs, butt hinges, lock strike plate, etc., complete, as specified, supplied and fixed with one shop coat of zinc chromate primer, complete all as specified and directed by Engineer-in-Charge.
Mild steel bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-Charge.
Mild steel bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with the including mild steel wire (annealed) not less than 0.9mm dia or securing with clips, complete all as specified and directed by Engineer-in-Charge.
Galvanised mild steel wire cloth 0.63mm nominal dia of wire & average width of aperture 1.18mm , complete all as specified and directed by Engineer-in-Charge.
Factory made steel window (Box type) without glazing bars, dovetailed or welded including hinges,steel handles, steel peg stays etc including one shop coat of red oxide zinc chrome primer and Including dismantling of existing unserviceable window, complete all as specified and as directed by Engr-in-Charge.
Factory made steel window (Box type) with glazing bars, dovetailed or welded including hinges,steel handles, steel peg stays etc including one shop coat of red oxide zinc chrome primer and Including dismantling of existing unserviceable window, complete all as specified and as directed by Engr-in-Charge.
4mm thick sheet glass ordinary quality any size and in any type of frame and glazing with oil putty ( or beading ) in square n.exc 0.5 Sqm in each panes, complete all as specified and directed by Engineer-in-Charge. MAKE : MODI GUARD/ SAINT-GOBAIN
Framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forget into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 410-0 or FE 310-0 and including dismantling of existing grills, complete all as specified and directed by Engineer-in-Charge.
Aluminium window air tight of anodised frame made of size 100mm x 45mm of section thickness-1.50mm thick and shutter stiles made of section 80mm x 45mm x 1.5mm thick with or without rebates, with 5.5mm thick tinted glass fixed with aluminium beads, including necessary jointing cleats/anodised aluminium fillets/alluminium glazing clips with rubber gasket, with aluminium fittings such as aluminium butt hinges 100mm long 03 Nos, aluminium anodised tower bolt 100mm long 02 No, aluminium anodised bow handles 100mm 01 No, aluminium hook and eye 150mm 01 No in each shutterm including aluminium grill of 5 to 6 dia, size of mesh not exc 7.5cm in either direction, as approved by GE, complete all as specified. Note:- All fitting shall be of ISI marked except cleats ) sizes of each shutter shall be as per site requirement all as directed and specified .
Anodised Aluminium door air tight of anodised frame made of size 100 mm x 45mm of section thickness -1.50 mm thick with one or more rebates including jointing cleats etc for fixing aluminium anodised door shutter fully panelled (two no of panels on each shutter) with 5.5 mm thick tinted glass as in panels shutter rail made of 80mm x45 mm of sheet thickness 1.50 mm (Top and bottom rails and stiles) single /double leaf side hung type including necessary jointing cleats /anodised aluminium fillets/ glazing clips with rubber gasket ,with aluminium fittings such as aluminium anodised tower bolt 200mm long 02 No for each door, aluminium anodised bow handles 150 mm 'D' type 02 nos for each shutter , mortice locks 6 lever, one on each door, door shutter mounted on bottom double action floor spring hydrailically regulated made up of 1.25mm thick aluminium alloy sheet foundation box , main body with stainless steel cover , governing mild steel heavy duty and door shutter top mounted on aluminium alloy pivot. -01 No on each shutter , bottom and floor stoppers, Complete all as specified. Note : All fitting shall be of ISI marked except cleats ) sizes of each door shall be as per site requirement all as directed and specified .
Aluminium partition of section (44x44)mm & vertical members (44x44) with top,bottom, with vertical members (44x44)mm with 3 ft spacing of each post vertically & horizontaly specing 75cm,5.5mm thick tinted glass/decorative PVC board, all beading rubber gasket & complete builder hard ware , complete all as specified and as directed by Engr-in-Charge.
Pre-Painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified & directed by Enge-In-Charge.
Pre-Painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm of any colour having tensile strength of 550Mpa as in roof covering/cladding to wall fixed with self tapping screws all as specified & directed by Enge-In-Charge.
6mm thick Non asbestos fibre cement building boards fixed or laid/inserted to timber /GI/ Aluminium grid/ framework with screws, complete all as specified and directed by Engineer-in-Charge.
Anodised aluminium snap grid frame work for false ceiling, complete all as specified and directed by Engineer-in-Charge.ge.
Plinth protection 50 mm thick in PCC 1:3:6, type C-1 ( using 20 mm graded crushed stone aggregate ) laid in alternate bays (not exceeding 2 Sqm each) finished even and smooth without using extra cement and providing joints through out the thickness of plinth protection, filled with mastic filling comprising one part of bitumen 85/25 grade and three parts of sand by weight, complete all as specified and as directed by Engr-in-Charge.
PCC 1:4:8 type D-2 as in floors 75mm thick, complete all as specified and as directed by Engr-in-Charge.
40 mm thick flooring in PCC 1:2:4 type B1 using 20mm graded stone aggregate surfaces finished even and smooth using extra cement (staircase incl steps, complete all as specified and as directed by Engr-in-Charge.
Non skid ceramic coloured tiles 7 to 8mm thick (Square or rectangular) area of each tile exceeding 0.11 Sqm but not exceeding 0.18 Sqm, laid in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles with and including laying of 15 mm thick screed bed or bedding layer in CM 1:6 , complete all as specified and directed by Engineer-
Vitrified ceramic light shade coloured tiles 9-10mm thick (Square/rectangular) polished area of each tiles size 600x600mm laid in floor, set and jointed in neat cement slurry and pointed in coloured cement to match over and including screed bed 15mm thick in cement mortar 1:6, complete all as specified and directed by Engineer-in-Charge
Glazed ceramic tiles 450 mm x 300 mm x 7to8mm/350X250X7mm thick on vertical surfaces such as skirting /dado etc. set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick rendering in cement mortar 1:4 on fair faces of brick work or concrete surfaces as backing coat, complete all as specified and directed by Engineer-in-Charge.
Machine cut kota stone slab flooring 18-20mm thick over 20 mm thck cement screed in CM 1:3 base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing , complete all as specified and directed by Engineer-in-Charge.
All as per item above but on skirting including screed bed of 15 mm thck in CM 1:4, complete all as specified and directed by Engineer-in-Charge.
18 to 20 mm thick,Granite (of any type) tiles 20mm thick machine cut, bedded and jointed with grey cement slurry and pointed with white cement with admixture of pigment to match the shade of granite stone including cutting and polishing types over 20 mm th screed bed in CM 1:4, complete all as specified and directed by Engineer-in-Charge.
Rounding of / moulding to edge (half round) of stone of any description including rubbing and polishing (Granite finish), complete all as specified and directed by Engineer-in-Charge.
60 mm thick glossy rubber mould interlocking machine pressed precast concrete (paver blocks red & yellow colour topping) any shape finished type conforming to IS-15658-2006,M -35 Grade laid dry over and including 30 mm compacted sand bed, size & pattern of tiles, complete all as specified and directed by Engineer-in-Charge
15mm thick rendering on fair faces of brick work or concrete surface in CM 1:6 finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
15mm thick rendering on fair faces of brick work or concrete surface in CM 1:4 finished even and smooth without using extra cement, complete all as specified and as directed by Engr-in-Charge.
Rendering 15 mm thick on fair faces of brick work or concrete surfaces, finished even and smooth (without using extra cement) on walls in cement mortar (1:4), including integral WPC by wt of cement as per manufacturer instruction (NOTE : Supply only WPC will be measured and paid for separately), complete all as specified and directed by Engr-in-charge.
Rendering 5 mm thick on fair faces of concrete surfaces on ceiling,roof projection,chajja in cement mortar (1:3) finished even and smooth , complete all as specified and directed by Engineer-in-Charge.
Preparation of new wooden or untreated wood surfaces of any description exc 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer, complete all as specified and directed by Engineer In Charge
Preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over priprimed, complete all as specified and directed by Engineer-in-Charge.
Complete removal of existing treatment on walls surfaces by brooming down with steel wire brushes, scrapping down smoke soot moulds moss and efflorescence salts washing, rubbing down and cleaning oil greasy spots etc and applying two coat of oil bound distemper including one coat of chalk whitening primer and 1 mm to 1.2 mm thick wall putty, complete all as specified and directed by Engineer-in-Charge.
Preparing newly plastered walls surfaces and applying two coats of distemper with distemper oil emulsion white or tinted over and including one coat of chalk whitening primer and 1 mm to 1.2 mm thick wall putty, complete all as specified and directed by Engineer-in-Charge.
Preparing of new plastered or un-decorated surfaces and applying three of white wash on wall surface, complete all as specified and directed by Engineer-in-Charge.
Preparing of new plastered or un-decorated surfaces and applying three of white wash on ceiling, complete all as specified and directed by Engineer-in-Charge.
Preparation of new plastered surfaces and applying two coats of cement base paint on new/undecorated wall surfaces, complete all as specified and directed by Engineer-in-Charge.
Viterous china wash basin, white flat back size 550 x 400mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP getting with holes fixed in repair, complete all as specified and directed by Engr-in-Chare.
Viterous china wash basin, white flat back size 550 x 400mm incl waste couping CP 32mm dia chain and plug and porcelan stopper and CI brackets of iron 65 x 65 x 6mm embedded in PCC block with PCC 1:2:4 type B-1 and PVC waste pipe 32mm dia & CP getting with holes, complete all as specified and directed by Engr-in-Chare.
Vitreous china wash hand basin counter type of size 580mmx450mm fixed (flat back and angle back type) any size, including cutting for and pinning in ends of brackets or erecting stand including brass chromium plated waste coupling, flexible PVC waste pipe with long screwed sank and fly nuts, complete all as specified and directed by Engineer-in-Charge.
Pillar taps cast copper alloy fancy type with capstan heads chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed of iron pipe of bore 15mm fixed in repair, complete all as specified and directed by Engr-in-Chare.
Pillar taps cast copper alloy fancy type with capstan heads chromium plated screwed down high pressure with or without lettered Hot or Cold with long screwed shanks and fly nuts screwed of iron pipe of bore 15mm, complete all as specified and directed by Engr-in-Chare.
PVC connection 15mm size with PTMT nuts of length 450mm fixed in repair, complete all as specified and directed by Engr-in-Chare.
PVC connection 15mm size with PTMT nuts of length 450mm, complete all as specified and directed by Engr-in-Chare.
PVC connection 15mm size with PTMT nuts of length 600mm fixed in repair, complete all as specified and directed by Engr-in-Chare.
Towel rail 600mm long aluminium tower bolts 20mm D type fixed in repair, complete all as specified and directed by Engr-in-Chare.
Towel Ring fixed with and including Chromium plated brass screws and wooden/plastic cleats (Minimum weight 90 gms) fixed in repair, complete all as specified and directed by Engr-in-Chare.
Steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 15mm bore all as specified.
Steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 20mm bore all as specified.
Steel water tubing medium grade galvanised with all fitting and fixed complete to wall and ceiling or laid in floors of 25mm bore all as specified.
Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe 25mm dia. fixed in repair, complete all as specified and directed by Engr-in-Chare.
Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe 15mm dia, complete all as specified and directed by Engr-in-Chare.
Stop valves, cast copper alloy, screwed down, high pressure, with crutch or butterfly handle, screwed both ends for iron pipe 20mm dia, complete all as specified and directed by Engr-in-Chare.
15mm angle valves (chromium plated) cast copper alloy screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed in repair, complete all as specified and directed by Engr-in-Chare.
15mm Bib taps, cast copper alloy, fency type chromium plated, with crtuch or butterfly handle, sc-rewed down, screwed for iron pipe or for brass ferrule fixed in repair, complete all as specified and directed by Engr-in-Chare.
Rotational moulded polythene water storage tanks 3 layer (cylindered vertical closed top ) hoisted and fixed in position including necessary connection nipple suitable for inlet, outlet and overflow pipes, all as specified in SSR Part –I of capacity of tanks 1000 ltrs and including dismantling of existing unserviceable water tanks and remove from site, complete all as specified and as directed by Engr-in-Charge.
Rotational moulded polythene water storage tanks 3 layer (cylindered vertical closed top ) hoisted and fixed in position including necessary connection nipple suitable for inlet, outlet and overflow pipes, all as specified in SSR Part –I of capacity of tanks1000 ltrs , complete all as specified and as directed by Engr-in-Charge.
Ball brass valves 20mm , high pressure, with polyethene float & fly-nut complete, screwed for iron pipe or brass ferrule fixed in repair, complete all as specified and directed by Engr-in-Chare.
Ball brass valves 20mm , high pressure, with polyethene float & fly-nut complete, screwed for iron pipe or brass ferrule, complete all as specified and directed by Engr-in-Chare.
Gun metal Gate valves 25mm with iron wheel head screwed both end for iron pipe, complete all as specified and directed by Engr-in-Chare.
CP fancy type mixture tap of std quality for mixing hot & cold water with centre hole mixer with fittings, complete all as specified and directed by Engineer-in-Charge.
Cast iron soil, waste and vent pipe 75mm dia bore (ISI Marked) sand cast pipes, in any length with or without ears, in cement joint, laid in trenches or fixed in walls etc, complete all as specified and directed by Engineer-in-Charge.
CI floor trap 75mm dia with CI grating including jointing to waste pipe in run lead complete and making good the disturbed surface to match the existing surface, complete all as specified and directed by Engineer-in-Charge.
CI bend/Tee suitable for 75mm bore pipe (any radius), diminishing pieces or tapers ( larger bore measured ) wit oval acess door, complete all as specified and directed by Engineer-in-Charge.
Vitreous china urinal,half stall type,white with grating and union for discharge pipe (excluding flushing cistern, flush pipe and waste pipe) including CP waste coupling, complete bedding urinal against wall in cement mortar 1:3 securing urinal to, plugs with and including 60mm long brass screws, pointing around urinal back in cement, complete all as specified and directed by Engineer-in-Charge.
Supply only integral water proofing compound, complete all as specified and directed by Engineer-in-Charge.
PVC (SWR) gully trap of size 150x110mm, setting and jointing with solvent cement, complete all as specified and directed by Engineer-in-Charge.
40mm thick PCC 1:2:4 type B-0 using 12.5 mm graded crushed stone aggregate as in damp proof course to horizontal or vertical surfaces including necessary form work, complete all as specified and directed by Engineer-in-Charge
PCC type D-2 (1:4:8), using 40 mm graded stone aggregates as in foundation filling & mass concrete, complete all as specified and directed by Engineer-in-Charge.
Aluminium hooks (single) 50mm to 60mm, complete all as specified and directed by Engineer-in-Charge.
Rotational moulded polythene water storage tanks 3 layer (cylindered vertical closed top ) hoisted and fixed in position including necessary connection nipple suitable for inlet, outlet and overflow pipes, all as specified in SSR Part –I of capacity of tanks 500 ltrs , complete all as specified and as directed by Engr-in-Charge.
Supply and lay XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 16 sq mm 2 core in trenches/floor/pole/GI pipe complete including cutting/chasing to any surface and making good to the disturbed surface to match the existing and including taking down of existing cable, complete all as specified and directed by Engineer-in-Charge.
Supply and lay XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10 sq mm 2 core in trenches/floor/pole/GI pipe complete including cutting/chasing to any surface and making good to the disturbed surface to match the existing, complete all as specified and directed by Engineer-in-Charge.
Dry coarse sand as cushioning to under ground cable provided with layer of 8 cms deep before laying the cable and 15 cms deep after laying and stretching the cable and punned to 18 cm thick , complete all as specified and as directed. Note : Only punned thickness shall be measured for payment purpose
Sub class ‘B’ old size well burnt bricks, laid flat in trenches as protection to cable complete all as specified and as directed.
GI tubes light grade 40 mm bore with all fitting/acessories for protection of cable on pole/wall and under road crossing including clamps, nut bolt etc and including sealing end of pipe with bituminous preformed wooden gutties complete all as specified and directed by engr-in-charge.
Taking down carefully alu/copper point wiring, light fan socket or power complete with fitting such as switches ceiling rose pendants, regulators, socket etc removing material to store for keeping in safe custody for reuse or disposal by credit and marking good to disturbed surfaces of walls, floors etc, complete all as specified and as directed by Engr-in-charge.
Point wiring concealed with 1.5 Sqmm copper conductor cable (multistrand) PVC insulated FRLS (unsheathed), drawing in and including PVC concealed conduit 20 mm dia,cutting chases wall & ceiling and making good to disrurbed surface of wall ,ceiling etc,having wall thickness not less than 1.50 mm with sunk cast iron/pressed steel terminal boxes made out of 1.2 mm thick sheet including one coat red oxide primer on internal and external surface covered with 3 mm thick hylam brand IS-2036 marked laminated sheet cover (for mounting switches, sockets, regulators etc), including 1.5 Sqmm PVC insulated (multistranded) FRLS copper conductor continuous earth wire for one light /Fan point/Exhaust fan controlled by one switch one way complete all as specified and directed.
All as per item Srl No 119 herein before but for 3 pin socket outlet 5 Amps on same board, complete all as specified and directed by Engr-in-charge.
All as per description of Serial item No 119 here-in-before but one 3 pin 5 Amp socket outlet on Independent board, complete all as specified and as directed by Engr-in-Charge.
All as per description of Serial item No 119 here-in-before but one 3 pin 5/15 Amp socket outlet on independent board with PVC insulated, unsheathed FRLS cable 2.5 Sqmm copper multistrand conductor, along with PVC insulated and unsheathed FRLS 1.5 Sqmm multistrand copper conductor earth wire connected to common earth and earth dolly complete, complete all as specified and as directed by Engr-in-Charge.
Switch socket combination piano type 5 pin 5 Amp flush type with box, complete all as specified and directed by Engr-in-charge.
Switch socket combination piano type 6 pin 15 Amp flush type with box, complete all as specified and directed by Engr-in-charge.
Switch piano flush button single pole one way 5/6 Amp, 240 Volts, complete all as specified and as directed by Engr-in-Charge.
Socket outlet 2 in 1, 3 pin piano type 5 Amps flush type, complete all as specified and directed by Engr-in-charge
Ceiling Rose Surface backilte 65x20mm size two/three terminal ISI marked complete
Electronic type fan regulators step type, 240 volt, flush type, suitable for 1200/1400mm sweep ceiling fan, ISI marked, complete all as specified and directed by Engr-in-charge.
Decorative ultra slim square profile LED lighting fixture 05 Watt with extruded polycarbonate, environmental friendly, energy efficient ready to use pack including taking down old US tube light fitting 1x36W, complete all as specified and directed by Engr-in-charge Make : Havells Cat No : LHEXBTP7IN1W005 or equivallent make of SYSKA/CG/Wipro
LED Bulk head (6500K) fitting of 9/10 Watt surface mounting type extruded aluminium body with opal diffuser suitable for 600LUMEN complete with testing, complete all as specified and directed by Engr-in-charge. Make :SYSKA Cat part -SSK-BH-9W/C&S cat part no-CG80IB10WLED or equivalent model of Havells Cat no-LHEXCFP7PN5W010or
Slim linear LED lighting fixture 10/12W watt 6500K LED batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, complete making all connection from ceiling rose to fittings including testing , complete all as specified and directed by Engr-in-charge. Make-Wipro Cat part no-D531065/ SYSKA Cat part no-SSK-T5-12W or equivalent model of Havells/C&S
Slim linear LED lighting fixture 18/20 watt, 6500K LED batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings, complete all as specified and directed by Engr-in-charge. Make:-Wipro Cat part no-D532065 /SYSKA Cat Part no-SSK-RA-1801-N/Havells Cat Part no-LHEXBXPNINIW020 or equivalent model of C&S
Sub main wiring with copper conductor cable (2 runs of cable) multistaranded 6 Sqmm PVC ISI marked with all insulated unsheathed in and including rigid PVC concealed conduit 25mm dia, 2mm wall thickness medium grade fitings including 6 Sqmm copper conductor cable PVC insulated unsheathed multithreaded using as continues earth wire connected to common earth and earth duly complete including taking down of existing Submain wiring and making good to the distrubed surface of wall & match with existing surface of wall, complete all as specified and as directed by Engr-in-charge. Note: Two runs of 6 sqmm and one run of 6sqmm cable and one run of PVC conduit/ casing capping shall be measured as one RM
Sub main wiring with copper conductor cable (2 runs of cable) multistaranded 4 Sqmm PVC ISI marked with all insulated unsheathed in and including rigid PVC concealed conduit 20mm dia, 2mm wall thickness medium grade fitings including 4 Sqmm copper conductor cable PVC insulated unsheathed multithreaded using as continues earth wire connected to common earth and earth duly complete including taking down of existing Submain wiring and making good to the distrubed surface of wall & match with existing surface of wall, complete all as specified and as directed by Engr-in-charge. Note: Two runs of 4 sqmm and one run of 4 sqmm cable and one run of PVC conduit/ casing capping shall be measured as one RM
Single pole and neutral sheet steel powder coated Distribution board for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 12 ways, fixed in repair complete all as specified and directed by Engr-in-charge Make: Legrand (Ekinox3) cat no- 507612 Ekinoxe/ schneider(Acti-9)/ Siemens(Betagard-8GB 32).
Single pole and neutral sheet steel powder coated Distribution board for MCBs fitted with bus bar , Neutral link ,Earth Bar and Din rail suitable for use on 240 V, 50 Hz supply double door SP&N DB system 8 waysfixed in repair complete all as specified and directed by Engr-in-charge Make: Legrand (DX-3) cat no- 507611 Ekinoxe/ schneider(Acti-9)/ Siemens(Betagard-8GB 32).
Sheet metal enclosures for distribution board when MCB to be used SPN ( Single pole and neutral ) 4 way, 240 Volts, sheet metal powder coated, IP 42 protection with 200 Amps rated bus bar, double door type complete all as specified and directed.
MCB SPN 40 to 63Amps 240V 'C' series ,50Hz,10kA lighting and other domestic loads incl all termnials, fitting etc. fixed in repair complete all as specified and directed by Engr-in-charge Make: Legrand (DX-3) cat no- 408637, 408639/ schneider(Acti-9)/ Siemens(Betagard- 5SL4).
MCB SPN 40 to 63Amps 240V 'C' series ,50Hz,10kA lighting and other domestic loads incl all termnials, fitting etc,complete all as specified and directed by Engr-in-charge Make: Legrand (DX-3) cat no- 408637, 408639/ schneider(Acti-9)/ Siemens(Betagard- 5SL4).
MCB SP 06 to 32 Amps 240V 'C' series ,50Hz,10kA suitable for lighting and other domestic loads incl all termnials, fitting etc. fixed in repair complete all as specified and directed by Engr-in-charge Make: Legrand (DX-3) cat no- 408587,90,92,93,94,95/ schneider(Acti-9)/ Siemens(Betagard- 5SL4)
MCB SP 06 to 32 Amps 240V 'C' series ,50Hz,10kA suitable for lighting and other domestic loads incl all termnials, fitting etc.,complete all as specified and directed by Engr-in-charge Make: Legrand (DX-3) cat no- 408587,90,92,93,94,95/ schneider(Acti-9)/ Siemens(Betagard- 5SL4)
Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB of 20 Amps 240 volt capacity fixed in repair complete all as specified and directed by Engr-in-charge
Slim linear LED lighting fixture 20 watt LED batten, with full base of extruded aluminium section acting as a heat sink with closed back, isolated driver, complete making all connection using 1.5 sqmm copper conductor multistrandard PVC insulated 2 core flexible cable with flexible PVC pipe from ceiling rose to fittings complete including taking down old US tube light fitting 1x36W and taken in schedule of credit all as per the direction of Engr-in-Charge. Make -Make model of Havells cat No LHEXCEP7UN1W020 or equilent to CG/ syska CAT No SSK ALB 20W/Wipro
LED light fitting PLUTO NEO PANEL 2x2 PLR 34 watt LED 857S environmental friendly , new generation , aesthetically designed ,ultra modern recess mounting luminaire with high brightness SMD LEDs as light source suitable for armstrong /grid /ceiling all as spesified and directed by Engr-in-charge Engr-in-Charge. Make -Havells cat No 840S or equilent to CG/ syska CAT No SSK-FP- 6060/Wipro
Security (street) light fitting 25 watt, new generation energy saving & environmental friendly long life versatile pressure die cost aluminium IP 66 with acylic, powder coated, pressure die cast aluminium compact high power LED street light with heat resistant toughed glass, corrosion resistant, isolated driver, including provision of GI tubing bracket of suitable size and fixed on wall including clamps, nut, bolts and washer for fixing of security (street) light completet including taking down old US light fitting of any type /size and taken in schedule of creditall as per direction of Engr-in-Charge. Make:SYSKA Cat no SSK-ST-25W(S) or equivalent in wipro cat No Havells/Wipro
Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 5 of MES Part-I and including taking down of existing Earthing including testing on completion including the material and labour of the following :- (a) Excavation and earth work for drilling hole for electrode in any type of soil. (b) PCC pit in cement concrete 1:2:4 type B-1. (c) Precast RCC cover with suitable handle 40 mm thick in PCC 1:2:4 type B-1, reinforced with welded steel wire fabric weighing not less than 1.87 Kg/Sqm. (d) Funnel with watering pipe of GI 20 mm nominal bore medium grade and copper lugs etc all as specified. (e) 15 mm nominal bore light grade GI protection pipe 5 mtr long for protection of earthing lead from mechanical injury or tempering. (f) Requisite quantity of common salt and charcoal. (g) Testing of earthing. Note : (a) On testing after completion of earthing, if the desired earth resistance is not obtained, the earthing will be re-done by the contractor at his own risk and cost to the entire satisfaction of the Engineer-in-Charge. (b) The contractor shall quote his rate considering taking down cost of existing unserviceable earthing.
Earth continuity conductor or main earhing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 4mm dia galvanised iron or steel wire .
Taking down fan, ceiling cable end, dismantling blades and kept in safe custody for refixing on same location all as specified and directed by engineer in charge.
Ceiling fan 1200mm sweep of any make obtained from above item, oiling, greasing cleaning slot, over hauling & replacement of defective nut bolts washer etc including painting. If as per site requirement fan will be found burnt rewinding will be provide by the contractor as per unit quoted rate all as specified and directed by Engr-in-charge.
Hanging /fixing only ceiling fan/Exhuast fan and connecting up including provision of cable from ceiling rose or connector to fan obtained from item no 33
Onload change over switch63 Amp with side handle in sheet enclosure suitable for single phase double pole 240Volts including taking down old change over switch, complete all as specified and directed by Engr-in-charge Make Havells (Cat No- IHBFDE0063 (240V) or equivalent to Legrand/L&T/C&S
RAMAN KUMAR
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .