Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.6 LAccepted-AOC SIDDHARTH CO 24 PADMAVATI SOCIETY VALLABH NAGAR BHURAVAV GODHRA GUJARAT 389001 | PANCH MAHALS | GUJARAT | 389001 | ₹36.6 L Quoted ₹37.5 L | L1 | Accepted-AOC Being Lowest Tenderer |
| 2 | L2₹41.3 L+₹3.8 L (10.1%)Rejected-Finance | ₹41.3 L+₹3.8 L (10.1%) | L2 | Rejected-Finance Being Other than Lowest Tenderer |
| 3 | L3₹41.6 L+₹4.1 L (10.9%)Rejected-Finance | ₹41.6 L+₹4.1 L (10.9%) | L3 | Rejected-Finance Being Other than Lowest Tenderer |
| 4 | L4₹48.4 L+₹10.9 L (28.9%)Rejected-Finance 1202 SAI PROVISO DHNISHT PLOT NO 72 73 SECTOR 20 KOPARKHAIRANE NAVI MUMBAI | THANE | MAHARASHTRA | 400601 | ₹48.4 L+₹10.9 L (28.9%) | L4 | Rejected-Finance Being Other than Lowest Tenderer |
| 5 | L5₹48.9 L+₹11.4 L (30.3%)Rejected-Finance NOT AVAILABLE | ₹48.9 L+₹11.4 L (30.3%) | L5 | Rejected-Finance Being Other than Lowest Tenderer |
| Sl No | Description | Qty | Unit | ASHOK ENTERPRISES L4 | SHRI SAI ENTERPRISES L6 | SHREE JAGDISH FURNITURE CO. L5 | N.S.ENTERPRISES L3 | SHREE ARIHANT CONSTRUCTION L2 | siddharth and company L1 |
|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, ceiling roses, lamp holders, brackets & other fitting & Fixtures connected, and making good to disturbed surfaces as directed by Engineer-in-Charge | 1,980 | Point | 3 ₹5,940 Lowest | 5 ₹9,900 | 8 ₹15,840 | 5 ₹9,900 | 10 ₹19,800 | 5 ₹9,900 |
| 2.00M&L for point wiring with FRLS PVC insulated, un-sheathed, multi stranded copper conductor cable of 1.5sqmm size, 1100volts, drawn through and including non metalic rigid PVC casing and caping not less than 25mm with all accessories fixed on wall//ceiling/truss including FRLS PVC insulated, unsheathed, multi stranded copper conductor FRLS cable of 1.5sqmm size as earth continuty conductor connected to common earth dolly including required numbers and size of PVC Modular box with cover plate fixed on wall for fixing the switches, switch sockets,sockets, regulators etc complete all as specified for:- NOTE: a) Colour coding shall be followed as given below:- i) Phase - Red/Yellow/Blue ii) Neutral - Black iii) Earth - Green b) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit. | |||||||||
| 2.01 | One light point controlled by one 5A switch | 820 | Point | 450 ₹3,69,000 | 500 ₹4,10,000 | 425 ₹3,48,500 | 350 ₹2,87,000 | 430 ₹3,52,600 | 250 ₹2,05,000 Lowest |
| 2.02 | One Fan point controlled by one 5A switch | 200 | Point | 450 ₹90,000 | 500 ₹1,00,000 | 435 ₹87,000 | 350 ₹70,000 | 430 ₹86,000 | 250 ₹50,000 Lowest |
| 2.03 | One Exhaust Fan point controlled by one 5A switch | 70 | Point | 450 ₹31,500 | 500 ₹35,000 | 445 ₹31,150 | 350 ₹24,500 | 430 ₹30,100 | 250 ₹17,500 Lowest |
| 2.04 | One Bell point controlled by one bell push | 30 | Point | 450 ₹13,500 | 500 ₹15,000 | 438 ₹13,140 | 200 ₹6,000 | 430 ₹12,900 | 150 ₹4,500 Lowest |
| 2.05 | One 5A flush type switch socket point on same board board | 200 | Point | 180 ₹36,000 | 200 ₹40,000 | 185 ₹37,000 | 400 ₹80,000 | 150 ₹30,000 Lowest | 250 ₹50,000 |
| 2.06 | One 5A flush type switch socket point on independent board | 200 | Point | 450 ₹90,000 | 500 ₹1,00,000 | 439 ₹87,800 | 300 ₹60,000 | 430 ₹86,000 | 250 ₹50,000 Lowest |
| 3.00 | M&L in repair for point wiring complete with proper clour coding using PVC insulated unsheathed multistranded copper conductor cable 2.5 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module complete for One 5 pin, 15A switch socket combination on the independent board complete all as specified and directed.
Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green | 100 | Per point | 600 ₹60,000 | 600 ₹60,000 | 555 ₹55,500 | 540 ₹54,000 | 700 ₹70,000 | 400 ₹40,000 Lowest |
| 4.00 | M&L for point wiring complete with proper clour coding using PVC insulated unsheathed multistranded copper conductor cable 4.0 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module complete necessary electric connection for each workstation point comprising of 02 Nos 6A sockets and 01 No 15A socket on same board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Switch socket measured & paid separately. | 50 | Per point | 700 ₹35,000 | 700 ₹35,000 | 645 ₹32,250 | 650 ₹32,500 | 800 ₹40,000 | 600 ₹30,000 Lowest |
Tender Value
₹49 L
EMD Value
₹98,000
Closing Date
23 Jul 2026, 6:55 pmClosed
LT COL ANIL KUMAR S
GARRISON ENGINEER NW KUNJALI DR HOMI BHABHA ROAD NAVY NAGAR COLABA MUMBAI 400005
8332 REPAIR TO INTERNAL WIRING, CABLES AND CERTAIN ALLIED ITEMS ETC AT LHS OF LION GATE OF NAVAL DOCKYARD UNDER GE KUNJALI, MUMBAI
2026_MES_774769_1
8332/E8
Open Tender
Civil Works
Item Rate
180 days
GE (NW) KUNJALI
ALL AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
GE (NW) KUNJALI
₹98,000
Yes
11 Sept 2026
25 Jun 2026
25 Jul 2026
4 Jul 2026
23 Jul 2026
9 Jul 2026
25 Jun 2026 - 4 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Taking down carefully old U/S point wiring copper/Aluminum (light/ fan /sockets/power) complete with switches, sockets, ceiling roses, lamp holders, brackets & other fitting & Fixtures connected, and making good to disturbed surfaces as directed by Engineer-in-Charge | 1,980 | Point | - | - |
| 2M&L for point wiring with FRLS PVC insulated, un-sheathed, multi stranded copper conductor cable of 1.5sqmm size, 1100volts, drawn through and including non metalic rigid PVC casing and caping not less than 25mm with all accessories fixed on wall//ceiling/truss including FRLS PVC insulated, unsheathed, multi stranded copper conductor FRLS cable of 1.5sqmm size as earth continuty conductor connected to common earth dolly including required numbers and size of PVC Modular box with cover plate fixed on wall for fixing the switches, switch sockets,sockets, regulators etc complete all as specified for:- NOTE: a) Colour coding shall be followed as given below:- i) Phase - Red/Yellow/Blue ii) Neutral - Black iii) Earth - Green b) Electrical wiring above false ceiling shall be drawn through medium grade PVC conduit. | |||||
| 2.01 | One light point controlled by one 5A switch | 820 | Point | - | - |
| 2.02 | One Fan point controlled by one 5A switch | 200 | Point | - | - |
| 2.03 | One Exhaust Fan point controlled by one 5A switch | 70 | Point | - | - |
| 2.04 | One Bell point controlled by one bell push | 30 | Point | - | - |
| 2.05 | One 5A flush type switch socket point on same board board | 200 | Point | - | - |
| 2.06 | One 5A flush type switch socket point on independent board | 200 | Point | - | - |
| 3 | M&L in repair for point wiring complete with proper clour coding using PVC insulated unsheathed multistranded copper conductor cable 2.5 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module complete for One 5 pin, 15A switch socket combination on the independent board complete all as specified and directed.
Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green | 100 | Per point | - | - |
| 4 | M&L for point wiring complete with proper clour coding using PVC insulated unsheathed multistranded copper conductor cable 4.0 sqmm size, 1100 volts ISI marked, FRLS grade drawn through and including non metalic rigid, double lock, ISI marked, not less than 25mm casing caping with all accessories such as tee, bends, elbow, reducers, junction box etcfixed on wall/ceiling/truss and one run of PVC insulated unsheathed, multistranded copper conductor cable of 2.5sqmm size, 1100 volts, ISI marked, FRLS grade green colour as earth continuty conductor connected to common earth dolly with and including modular box with cover plate frame in any module complete necessary electric connection for each workstation point comprising of 02 Nos 6A sockets and 01 No 15A socket on same board complete all as specified and directed. Note: (a) Colour coding shall be folowed as (i) Phase- Red (ii) Neutral - Black (iii) Earth - green (b) Switch socket measured & paid separately. | 50 | Per point | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.64 MB
BOQ_867553.xls
BOQ • 2.10 MB
8332TENDERDOCUMENTS.pdf
Tender Documents • 1.85 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .