Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹20.3 LAccepted-Finance PALAMPUR BHUANA DISTT KANGRA H P 176103 | PALAMPUR | KANGRA | HIMACHAL PRADESH | 176103 | ₹20.3 L | L1 | Accepted-Finance OK |
| 2 | L2₹20.3 LRejected-Finance R O RAJPUT VILLA BELOW BHOGAL NIWAS SHIMLA HIMACHAL PRADESH | KANGRA | HIMACHAL PRADESH | 176028 | ₹20.3 L | L2 | Rejected-Finance REJECT |
| 3 | L3₹20.6 LRejected-Finance VPO LADBHAROL TEHSIL LADBHAROL DISTT MANDI H P | ₹20.6 L | L3 | Rejected-Finance REJECT |
Tender Value
₹19.8 L
EMD Value
₹39,660
Closing Date
29 Jun 2026, 4:00 pmClosed
EE HIMUDA DIVSION SHIMLA
HIMUDA DIVSION SHIMLA KASUMPTI
Self financing Scheme at Basal, Distt. Solan H.P.SH Structural Strengthening of Block No. 22 i.e Retrofitting of Column ends, other beam and RCC Wall etc. Specialized Job thereof.
2026_HIMUD_137264_1
NO HIMUDA SD E TENDER 2119-28 DATED 22.06.2026
Open Tender
Civil Works
Percentage
60 days
BASAL SOLAN
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,180
₹39,660
11 Jul 2026
23 Jun 2026
30 Jun 2026
23 Jun 2026
29 Jun 2026
23 Jun 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Earthwork in excavation by manually over areas (upto all depth & width as well as on plan) including getting out and disposal of excavated earth upto all leads and lifts as directed by EIC pick and jumper work. | 61.02 | Per Cum | 529.05 | ₹32,282.63 |
| 2 | Chipping of Plaster/Concrete Upto cover: Chipping: Chipping of loose concrete from columns & all other concrete surfaces to expose sound concrete beneath using light chisel & hammer & also preparing concrete surface to receive further treatment, disposing the debris as directed. including carriage of material in all leads and lifts. | 50.18 | Per Sqm | 267 | ₹13,398.06 |
| 3 | Supply and apply of rustremover cum passivator to remove rust from existing reinforcement, Rust remover material, Consumption: 0.2kg/m2/coat, Density: 1.01 kg/l at 30 deg celcius including carriage of material in all leads and lifts. | 30 | Per kg | 427 | ₹12,810 |
| 4 | Supply and apply a cement based polymer modified rebar corrosion protection system to existing reinforcement Corrosion Inhibitor, Product requirements: Carbonation resistance: 2mm of Corrosion inhibitor corresponds to 20mm of normal mortar ; bond strength> 1N/mm2 according to ASTM C 882-78 including carriage of material in all leads and lifts. | 90 | Per kg | 142 | ₹12,780 |
| 5 | P & F of Extra 12mmX 120MM deep L-type shear rebar connector Providing and supplying heavy duty Resin Epoxy Chemical Mortar with Steel Rebar. The product should be approved by ETA,ICC, CSTB, COLA, BZS with Shock approval, Seismic approval in Rebars to use in cracked/un-cracked concrete, tested for service temperature of -40deg C to +80 deg C. The chemical should have ETA for service life of 100 years & seismic rebar as a minimum qualifying criteria. The installation depth shall be supported by design based on EC2/TR069/TR066/HIT-Rebar Design Method using Profis Rebar Software. Drilling hole with double flute type drill bits/hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A12 battery dispenser along with piston plug and extension hose for longer depths to ensure no air bubbles are in the hole and then fixing with Rods, conducting occasional site inspection, executing work by trained personnel and occasional supervision from the manufacturer’s representative in India. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. Scanning before drilling to be done with HILTI PS 300 to avoid hitting existing rebars. Pull out test report shall be submitted to the Structure engineer to validate the installation quality. .including carriage of material in all leads and lifts. | 624 | Each | 579.8 | ₹3,61,795.2 |
| 6 | P & F of Extra rebar 20mm dia*300mm depth Vertically: Providing and supplying heavy duty Resin Epoxy Chemical Mortar with Steel Rebar. The product should be approved by ETA,ICC, CSTB, COLA, BZS with Shock approval, Seismic approval in Rebars to use in cracked/un-cracked concrete, tested for service temperature of -40deg C to +80 deg C. The chemical should have ETA for service life of 100 years & seismic rebar as a minimum qualifying criteria. The installation depth shall be supported by design based on EC2/TR069/TR066/HIT-Rebar Design Method using Profis Rebar Software and approved. Drilling hole with double flute type drill bits/hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A12 battery dispenser along with piston plug and extension hose for longer depths to ensure no air bubbles are in the hole and then fixing with Rods, conducting occasional site inspection, executing work by trained personnel and occasional supervision from the manufacturer’s representative in India. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. Scanning before drilling to be done with HILTI PS 300 to avoid hitting existing rebars. Pull out test report shall be submitted to the Structure engineer to validate the installation quality. including carriage of material in all leads and lifts. | 270 | Each | 1,164.3 | ₹3,14,361 |
| 7 | P & F of Extra rebar 16mm dia*300mm depth Vertically: Providing and supplying heavy duty Resin Epoxy Chemical Mortar with Steel Rebar. The product should be approved by ETA,ICC, CSTB, COLA, BZS with Shock approval, Seismic approval in Rebars to use in cracked/un-cracked concrete, tested for service temperature of -40deg C to +80 deg C. The chemical should have ETA for service life of 100 years & seismic rebar as a minimum qualifying criteria. The installation depth shall be supported by design based on EC2/TR069/TR066/HIT-Rebar Design Method using Profis Rebar Software and approved. Drilling hole with double flute type drill bits/hollow drill bits to the required depth by rotary hammer drill, cleaning with brush and jet of clean air, filling resin and hardener using serrated nozzle to eliminate mixing error with standard HDE A12 battery dispenser along with piston plug and extension hose for longer depths to ensure no air bubbles are in the hole and then fixing with Rods, conducting occasional site inspection, executing work by trained personnel and occasional supervision from the manufacturer’s representative in India. The installation and the setting instructions should be strictly followed as per the manufacturer’s recommendations. Scanning before drilling to be done with HILTI PS 300 to avoid hitting existing rebars. Pull out test report shall be submitted to the Structure engineer to validate the installation quality. including carriage of material in all leads and lifts. | 54 | Each | 924.85 | ₹49,941.9 |
| 8 | Providing extra reinforcement with TMT bars as per site design requirement including straightning, cutting, bending, placing in position, binding with G.i. wire of 18 gauge etc. complete in all respects. Additional reinforcement with adequate lap length & rings at required spacing shall be tied with existing reinforcement using binding wire or welded complete as per site requirements and direction of EIC. including carriage of material in all leads and lifts. | 2,115.39 | Per Kg | 109 | ₹2,30,577.51 |
| 9 | P, M & A of epoxy resin bonding agent concrete:
Providing, mixing & applying two component epoxy resin concrete bonding coat on prepared Rcc surfaces as per manufacture specification excluding preparation of surface by chippimg and thoroughly cleaning of surface complete wherever required. including carriage of material in all leads and lifts. | 55.68 | Per Sqm | 578 | ₹32,183.04 |
| 10 | P & F & removing of water tight shuttering:
Form Work: Providing, Fixing & removing water tight shuttering (form work) using film coated 12 mm thick plywood sheets can be made for micro-concreting the beams & columns in line and level with proper supports. Item rate is inclusive of the materials, all labour, supervision, tools and tackles, and transportation etc., complete as per specification and as directed. including carriage of material in all leads and lifts. | 103.1 | Per Sqm | 494 | ₹50,931.4 |
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.70 MB
Tendernotice_2.pdf
PDF • 2.23 MB
Tendernotice_3.pdf
PDF • 0.18 MB
BOQ_203152.xls
BOQ • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].