Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹27.4 LAccepted-AOC | 1 | Accepted-AOC L1 | |
| 2 | 2₹29.1 L+₹1.5 L (5.36%)Rejected-Finance | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹29.2 L+₹1.6 L (5.90%)Rejected-Finance | 3 | Rejected-Finance Not L1 | |
| 4 | 4₹31.3 L+₹3.7 L (13.4%)Rejected-Finance NO 6 NJ BUILDING GANGAMMA TEMPLE ROAD JALAHALLI POST BANGALORE 560 013 | BANGALORE | BANGALORE | KARNATAKA | 560013 | 4 | Rejected-Finance Not L1 |
Tender Value
Refer Docs
EMD Value
₹54,000
Closing Date
23 Nov 2020, 6:00 pmClosed
GARRISON ENGINEER CENTRAL BANGALORE
MILITARY ENGINEER SERVICES GARRISON ENGINEER CENTRAL AGRAM POST BANGALORE 560007
PROVISION OF TOILET BLOCK INCLUDING CONNECTED WORKS FOR JCOs NCOs NEAR BUILDING NO ETA 81 AND PROVISION OF EXHAUST FAN IN KITCHEN AT DOMLUR MD ACCOMMODATION INCLUDING CERTAIN MINOR AND REVENUE WORKS OF ASC CENTRE COLLEGE UNDER GE CENTRAL BANGALORE
2020_MES_363569_3
8942/E8
Open Tender
Civil Works
Item Rate
180 days
BANGALORE
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Yes
GARRISON ENGINEER CENTRAL BANGALORE
₹54,000
Yes
6 Jan 2021
20 Oct 2020
25 Nov 2020
20 Oct 2020
23 Nov 2020
4 Nov 2020
20 Oct 2020 - 22 Nov 2020
Amount
B/R PORTION : M & L for surface excavation averaging 15cm deep and n.exc 30cm deep and getting out as in soft/loose soil complete all as specified and directed.
Excavating in post holes (or similar holes) in soft/loose soil each n. exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n. exc 25cm, watering and removing surplus soil to a distance n. exc 50m and making good surface as directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation, etc area not exceeding 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm as in soft/loose soil complete all as specified and directed.
Removing excavated material to a distance exc. 1.50 KM but not exc 5 KM and depositing where directed at a level not exc 1.5 m above the starting point complete all as specified and directed.
M & L for ATT by treating the backfill in contact with foundation at the rate of 7.50 litres of emulsion per square metre of vertical surface (Area of sub structure in contact with backfill to be measured)
M & L for ATT by treating the top surface of filled earth at the rate of 5.00 litres of emulsion per square metre of surface area.
M & L for ATT by treating the soil under plinth protection at the rate of 5.00 litres of emulsion per square metre of surface area.
M & L for ATT by treating the soil along wuth external perimeter of building at the rate of 2.50 litres of emulsion per metre of the perimeter wall. Make name ATT chemical for item No 5 to 8 :- DURSBAN/LETHAL/TRISUL
M & L for Hardcore of broken/crushed stone aggregate of gauge n.exc 63 mm deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for 40mm thick DPC to horizontal or vertical surfaces using PCC 1:2:4, type B-0 mixed with integral water proofing compound (WPC) @ 3% of cement weight including necessary form work complete all as directed. Note:- Integral water proofing compound shall be measured and paid separately in respective item.
M&L for precast cement concrete block masonry type C1, 1:3:6 (20 mm graded granite stone aggregate) with solid blocks, exc 10 cm in width and setting in cement mortar 1:6 complete all as specified and directed.
M & L for Plain cement concrete 1:2:4, type B-1, (using 20 mm graded stone aggregate) as in coping, kneelers, bed plates etc including weathering slightly rounded or chamfered angles including necessary form work complete all as specified and directed.
M & L for Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in foundation, filling and mass concrete, etc complete all as specified and directed.
M & L for 75mm thick Plain cement concrete 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub-base of floor, etc complete all as specified and directed.
M & L for 25mm thick Plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in level course of floor, etc complete all as specified and directed.
M & L for non-skid, ceramic, coloured tiles, Grade B II(a), 7 to 8mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc, including 15 mm thick screed bed in cement mortar 1:4 and set & jointed in neat cement slurry and pointed in white or coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for glazed ceramic, coloured tiles, Grade B III, 7 to 8 mm thick area of each tiles not exc 0.06 sqm as in skirting including 10 mm thick screed bed in cement mortar 1:3 set & jointed in neat cement slurry and pointed in coloured cement to match with the shade of tiles complete all as specified and directed.
M & L for precast machine pressed interlocking paver block any shaped and size conforming to IS- 15658-2006, 60mm thick, M-35 grade concrete with grey cement and no pigment, set and jointed in dry sand including providing 60mm thick dry sand filling below paver blocks complete all as directed
M & L for precast chequered cement concrete tiles of size 30cm x 30cm x 25mm thick, as in floors etc, including 15 mm thick screed bed in cement mortar 1:4 and set & jointed in neat cement slurry and pointed in grey cement and pigments to match with the shade of tiles complete all as specified and directed.
Demolition of stone slabs of any description and thickness in floors/ walls laid, bedded and pointed in any mortar etc complete including removing the same and debrises outside MD land all as directed.
M&L for machine cut kota stone slab, self finished, 20 to 25mm thick laid and and jointed in grey neat cement slury and pointed in coloured cement to match with the shade of the stone slab including providing 20mm thick screed bed in CM 1:4 including rubbing, polishing complete all as directed.
S & F Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete with glazing bars, dovetailed or welded complete all as specified and directed.
S & F Steel windows with side hung shutters including box type hinges with steel handle, and steel peg stay, complete without glazing bars, dovetailed or welded complete all as specified and directed.
S & F 4 mm thick, sheet glass, ordinary quality and glazing with oil putty/timber beads in square not exceeding 0.5 Sqm in each pane complete all as specified and as directed.
M & L for moorum/sand/red bajri filling under floors or in foundations laid in layers n exc 15cm thick, spread, levelled and rammed including watering complete all as specified and directed.
M & L for Reinforced Cement Concrete M-25 nominal mix as in foundation, footings foundation beams, plinth beams etc complete all as specified and directed.
M & L for Reinforced Cement Concrete M-25 nominal mix as in columns, pillars, piers, post and struts etc complete all as specified and directed.
M & L for Reinforced Cement Concrete M-25 nominal mix as in beams, cantilevers, lintel beam etc complete all as specified and directed.
M & L for Reinforced Cement Concrete M-25 nominal mix as in slabs supported on walls, beams and column in floors, roofs, landings, balconies and in shelves and the like complete all as specified and directed.
M & L for Reinforced Cement Concrete M-25 nominal mix as in chajjas etc complete all as specified and directed.
M & L for use & waste Form work to sides of concrete foundations, footings, raft beams, sides and soffits of plinth beams and the similar works for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Form work to sides of concrete columns, pillars, piers, post and struts and the similar works for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Form work to soffits of suspended slabs such as roof slabs, floor slabs, landings, balconies and in shelves and the like for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Form work to sides of concrete chajjas and the similar works for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Form work to soffits and sides of beams, lintel beam for flat rough finished surfaces of concrete complete all as specified and directed.
M & L for use & waste Form work to sides/edges of concrete flats, floor and roofs, in walls, horizontal or slopeing and the similar work, 10cm to 20cm wide for rough finished surfaces of concrete complete all as specified and directed.
S & F TMT steel bars 10mm dia and over, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S & F TMT steel bars 6 to 8mm dia, cut to length, bend to shape required, including cranking, bending spirally as in tie/stirrups of columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S & F TMT steel bars 6 to 8mm dia, cut to length, bend to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
S & F mild steel work in tubular trusses, post fixed independently, purlins using ERW or butt welded tubes conforming to IS 1161-1998, grade YSt-240, including cutting, welding complete all as specified and directed.
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick (Total coated thickness) of any colour, finished with resin coat on both surfaces @ 150 gm/sqm of coating (total both surfaces) having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with best quality self tapping screws as specified
M & L for Plain cement concrete 1:2:4, type B-1 (using 20 mm graded stone aggregate) as in benching including finished the top surfaces even and smooth using extra cement complete all as specified and directed.
M & L for 75 mm thick, plain cement concrete 1:3:6, type C-2 (using 40mm graded stone aggregate) as in plinth protection laid in proper slope/gradient etc, finishing cement concrete surface even and smooth without using extra cement including making joints with bitumastic filing in proportion of bitumen and sand 1:2 complete all as specified and directed.
S & F solid PVC door frames of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube complete all as specified and directed.
S & F factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded, plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail, panelling of plain colour PVC sheet 5mm thick to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and jointed together with solvent cement, as per specification and drawing and as directed.
S & F 100 mm size, butt hinges, medium weight, cold rolled complete all as specified, and directed.
S & F 200 mm long, Aluminium, barrel tower bolts of extruded section of aluminium alloy, anodised finish not be less than Grade AC 10 of IS 1868:1996 with transparent anodic film complete all as specified and directed.
S & F 150 mm size, Aluminium handles, cast type, anodised to a bright natural, mat finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and directed.
S & F aluminium alloy anodised sliding door bolt with hasp & staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy, length of bolt of 250 mm anodised finish not be less than Grade AC 10 of IS 1868:1996 complete all as specified and directed.
S&F Vitreous China Squatting Pan"Orissa pattern" size 580 mmx440 mm white with integral foot rest S or P trap etc. including 10 ltr capacity low level PVC Flushing cistern, PVC connection pipe, 15 mm dia, 600 mm long and 32mm dia flush pipe, S or P Trap & Provision of concrete bedding and making good to floor all as specified & directed by Engineer-in-charge.
S & F 10 litre capacity, PVC valve less syphonic action type, 32mm dia flushing cistern, low level, white, with inlet, ball valve, flush pipe, float and handle including PVC connection pipe of 15mm dia, 600mm long, brackets complete all as specified and directed.
S & F Vitreous China urinal, half stall type, white (minimum) with grating and union for discharge pipe (excluding flushing cistern, flush pipe & waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement complete complete as specified and directed. (Make: Parryware Cat No. C0575 or equivelant of make Hindware/Cera)
S & F in repairs PVC connection pipe, 450mm long. Make: CERA/Hindware/Parryware/PRAYAG
S&F Vitreous China Wash hand basin , white flat back size 550x400 mm including a pair of mild steel angle iron brackets duly painted, erected/embeded in wall, providing Pillar Tap 15 mm bore Chromium plated cast copper alloy with capstan heads, high pressure, fancy type with long screwed shanks and fly nuts, 32 mm waste coupling brass chromium plated suitable for wash hand basins & 32 mm dia LDPE PVC waste pipe, PVC connection 15 mm size 600 mm long including cutting hole and pinning in ends making good disturbed portion using cement mortar 1:3 complete all as specified & directed by Engineer-in-charge.
Supplying and laying of 20mm dia CPVC pipes (ISI marked) SDR 11 & Plain CPVC SDR 11 fittings on walls/ceiling or laying in floors complete all as specified.
S&F rotational moulded polyethylene water storage tanks 1000 litre capacity (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including 20 mm dia brass ball/float valve high pressure with polythene float and flynut, 20 mm water tank nipple suitable for HDPE water tank, 20mm bore gun metal gate/globe valve with iron wheel head complete all as specified and directed.
S & F 20 mm bore, Ball valves high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball screwed for iron pipe and fixed. (Minimum weight - 210 gms) complete all as specified and directed.
M & L for rendering 15 mm thick in cement mortar 1:6 on other than fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 10 mm thick in cement mortar 1:6 on other than fair faces of brick masonry or concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
M & L for rendering 15 mm thick in two layer (10mm + 5mm thick) on fair faces of brick work or concrete surfaces in cement mortar 1:4, mixed with water proofing compound at top 5mm thick layer by weight of cement as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and directed. (Note : WPC shall be measured and paid separately against respective item).
M & L for rendering 5 mm thick in cement mortar 1:3 on concrete surfaces and finishing the surfaces even and smooth without using extra cement complete all as specified and directed.
"Supply only" liquid water proofing compound complete all as specified and directed. (Make : Dr FIXIT/Fosroc/choksey)
M & L for Preparation of newly plastered surfaces of walls and applying two coats of cement base paint over a coat of alkali resistant priming paint complete all as specified and directed.
M & L for preparing newly plastered surfaces of internal walls, etc and applying two coats of distemper oil emulsion over a coat of primer including 1 to 2mm thick wall care putty complete all as specified and directed.
M & L for preparation of new plastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed.
M & L for Preparation of new steel surfaces of any description, over 10 cm in width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide, zinc chrome primer complete all as specified and directed.
Cutting into existing manholes for inserting new drain pipe, 150mm bore and making good to pipe and rendering, cutting out existing benching for and forming branch channel in cement concrete 1:2:4 type B1 finished to match with existing complete all as directed.
M & L for Plain cement concrete 1:4:8, type C-2 (using 40 mm graded stone aggragate) as in bed to drain pipes including packing under and haunching against the sides of pipes after they are laid and tested complete for 150 mm bore SGSW drain pipes complete all as specified and directed.
M & L for Salt glazed stone ware drain pipes 150 mm bore, grade 'A' laid in trenches, jointed and tested complete all as specified and directed.
M&L for rendering 15mm thick in CM 1:4 mixed with water proofing compound by weight of cement as per manufactureres instructions finished even & smooth without using extra cement on roof/floor. Note: WPC shall be measure and paid seperatly under supply only item.
M&L for Applying oil bound bitumen primer @ 0.20 kg/sqm and providing 3mm thick APP modified water proofing membrane weighting not less than 3.6 kg/sqm reinforced with non woven polyester matt weighing not less than 160 gm/sqm having softening point not less than 150mm centigrade, having tensile strength of 650 N/sqcm and 350 N/sqcm in longitudinal and transverse directions respectively of the reinforced tearing strength of 180N by torch application with minimum 10cm side overlapping and 15cm end lap, applying a coat of blown grade hot bitumen 90/15 over the mebrance @ 1.2 kg/sqm top of membrane surface shall then be finished with solar reflective bituminous aluminium paint @ 0.10 kg/sqm complete all as per manufacturer instructions and as directed by Engineer-in-Charge over roof and wall surfaces.
Supply, laying, connection and testing, 20mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixtures complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
Supply, laying, connection and testing, 25mm bore, Steel water tubing, galvanised, medium grade with all fittings and fixtures complete to walls and ceilings or laid in floors, etc complete all as specified and directed.
S & F towel rail, 600 mm long of PTMT fixed with and including chromium plated brass screws in wooden/plastic cleat or rawl plug complete all as directed. (Minimum weight 190 gms).
S&F in repair 110 mm dia UPVC (SWR) pipes, Type 'B', single socketed,in any length with rubber ring joints,laid in trenches or in floors complete all as specified and directed.
S&F in repair 110 mm dia UPVC (SWR) pipes, Type 'B', single socketed,in any length with rubber ring jointsfixed to walls complete all as specified and directed.
S&F in repair 75 mm dia UPVC (SWR) pipes, Type 'B', single socketed,in any length with rubber ring joints,laid in trenches or in floors complete all as specified and directed.
S&F in repair 75 mm dia UPVC (SWR) pipes, Type 'B', single socketed,in any length with rubber ring jointsfixed to walls complete all as specified and directed.
S&F UPVC (SWR) bends 75 mm with access door complete all as specified and directed.
S&F UPVC (SWR) bends 110 mm with access door complete all as specified and directed.
S&F UPVC (SWR) junction single,(single T) 110 mm with access door complete all as specified and directed.
S&F UPVC (SWR) junction single,(single T) 75 mm with access door complete all as specified and directed.
S&F UPVC (SWR) branch piece, single,(single Y) 110 mm with access door complete all as specified and directed.
S&F UPVC (SWR) branch piece, single,(single Y) 75 mm with access door complete all as specified and directed.
S&F UPVC (SWR) vent cowl suitable for 75 mm dia pipe.
S&F UPVC (SWR) vent cowl suitable for 110 mm dia pipe.
S & F in repair 125/110mm, PVC (SWR) gully trap, with grating including jointing to waste pipe with solvent cement, fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
S & F in repair 75 mm dia outlet , PVC (SWR) floor trap, with grating including jointing to waste pipe fixed in cement concrete type B-1 (1:2:4) complete all as specified and directed.
E/M PORTION : M & L for Point wiring concealed type, with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including providing PVC conduit 'medium grade' with all fittings and accessories (like Tee, bend etc.) complete in walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point and earth dolly including MS/PVC terminal box with 3mm thick masonite laminated sheet top cover fixed on wall with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed. Note:- Cost elements for cutting chases to wall etc and making good using cement mortar 1:3 shall deemed to be included in quoted rate.
M & L for Point wiring surface type, with 1.5 Sqmm (nominal area), FRLS PVC insulated, multistranded, single core unsheathed, copper conductor cables passing through and including providing PVC conduit 'medium grade' with all fittings and accessories (like Tee, bend etc.) complete in walls /ceiling etc. with and including 1.5 Sqmm (nominal area) FRLS, PVC insulated, unsheathed, stranded, single core, copper cable green in colour as earth continuity wire connecting to common earth point and earth dolly including MS/PVC terminal box with 3mm thick masonite laminated sheet top cover fixed on wall with suitable sizes cadmium plated iron screws and washers etc.for mounting switches, sockets, regulators etc complete for one light/fan/bell/buzzer point controlled by one ,one way switches complete all as specified and directed.
All as per item No. 92 here in before but wiring with cables of size 2.50 sqmm for wiring & cables of size 2.50 sqmm both (FRLS) as continuous earth wire for one 15 Amps, 3 pin Switch/Socket outlet on Independent board complete all as specified and directed.
S & F switch piano, 5 Amp, single pole, flush type one way 230 volts complete all as specified and as directed.
S & F switch socket combination 5 in 1, 3 pin 5 Amp and 15 Amps single pole, flush type 230 volts complete all as specified and as directed.
S & F Ceiling rose, 3 phase/PVC/polycarbonate (bearing ISI marked), isolated body including providing PVC square/round block complete all as specified and directed.
S & F Factory made distribution board (DB), Double Door in sheet steel enclosure fitted with common bus bar neutral link, earth bar and din rail, SPN, 4 way, 240 Volts IP-43, IK -09, suitable for housing MCB's complete all as specified and directed.
S & F MCB, SPN, 240 Volts, 63 Amps, 'C' Series, 10KA breaking capacity complete all as specified and directed.
S & F MCB, SPN, 240 Volts, 6-32 Amps, 'C' Series, 10KA breaking capacity complete all as specified and directed.
S & F MCB, 'C' Series, SP, 240 Volts, 6 to 32 Amps, 'C' Series, 10KA breaking capacity complete all as specified and directed.
M & L for Sub main wiring with two runs of 4 sqmm (Nominal area) single core FRLS cable PVC insulated, multistranded, unsheathed, copper conductor cables 1100 Volts grade drawn through PVC conduits, medium grade, of suitable size, fixed to wall/ceiling etc with all accessories, fittings, fixures including 4 sqmm (nominal area) single core, PVC insulated, multistranded, unsheathed, FRLS copper conductor as earth wire and duly connected to common earth point including PVC conduits/casing-caping of suitable size complete all as specified and as directed by Engineer-in-charge. (Note : PVC Conduits, two run wiring cables and one run of earth wire will be measured as one length.)
Cutting hole/opening through stone masonry wall of 38mm thick suitable for providing 300mm sweep exhaust fan and making good the disturbed surfaces using cement mortar 1:4 or PCC 1:2:4, type B1 as required including toothing and bonding, finished the surfaces to match with existing ie white/colour wash as required complete all as directed.
Supply and Fixing exhaust fan, 300mm sweep, AC single phase 230/240 Volt including louver cut to fit with hole for exhaust fan complete all as directed.
Supply & Fixing 5 star rated energy saving ceiling fan 1200mm sweep (white) with all accessories and hanging the ceiling fan from fan hook with 3 core flexible copper wire 24/0.20 sqmm from ceiling rose, etc all as directed. Make : Model ES-50 of Havells or equivalent in Usha/Orient.
Supply installation commissioning and testing of water cooler, fully stainles steel, electric driven, single phase, 230 Volts, having approximately 180 litres storage capacity and nominal cooling capacity of 150 litres per hour complete all as directed. Make Bluestar/Whirlpool/Voltas as approved by GE
Supply installation commissioning and testing of deep freezer glass top of capacity 400 litres, electric driven, single phase, 230 Volts, complete all as directed. Make Bluestar GT- 400/Whirlpool/Voltas as approved by GE
Supply and fix Voltage stabilizer of 3 KVA for automatic operation single phase naturally cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230V with accuracy of 2.5% Plus/Minus . Make AE /Venus/Sen & Pandit/Vertex.
Supply and fix Voltage stabilizer of 5 KVA for automatic operation single phase naturally cooled indoor type & designed for input variation between 170 V to 250 V with output voltage stabilized at 230V with accuracy of 2.5% Plus/Minus. Make AE Venus/Sen & Pandit/ Vertex.
S&F LED tube light fitting of 20 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make : Havells/Crompton Greaves/Bajaj
S&F LED tube light fitting of 10 watts 6000K , 230 volt, with aluminium extruded channel powder coated with diffuser for glare free light complete with all fixing accessories such as 2 nos of PVC square/round boxes, screws, etc and connecting up with three core flexible copper conductor cable of size 24/0.20 sqmm complete all as specified and directed by Engr-in-charge. Make : Havells/Crompton Greaves/Bajaj
S&F energy saving environmental friendly long life, with high power LED building security light 1x 25 Watt LED pressure die-cast aluminium, heat resistant, toughened glass diffuser, IP65/66 and wired with all accessories and including bracket made out of 40 mm bore GI pipe 'Light grade', 1.50 M long made to required shape, fixed to wall and connection up with 3 core flexible copper conductor cable 4/20 mm size, 1.5m long and testing on installation all as specified and directed. Make Havells/Bajaj/phillips/CG
S & F 15 mm bore, bib taps, cast copper alloy, chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F 15 mm bore, stop/angle valves, fancy type with flange and shank, cast copper alloy, chromium plated with capstan head, screwed down, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F 20 mm bore, gun metal gate valve, with iron wheel head, screwed both ends, screwed for iron pipe or for brass ferrule complete all as specified and directed.
S & F 25 mm bore, gun metal gate valve, with iron wheel head, screwed both ends, screwed for iron pipe or for brass ferrule complete all as specified and directed.
M & L for drilling hole and tapping in existing G I water mains in positio for branch connection of 25mm bore pipe complete including all fittings/specials as required and directed.
Supply and laying cable UG XLPE insulated screened, PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10.00 Sqmm 2 core including alumunium lugs etc for connecting and taking out old one complete all as specified and directed. (Note: Excvation and earth work shall be measured and paid seperately)
Supply and laying well burnt bricks, sub class 'B' bricks laid breath wise across the length of cable in trenches for protection of UG cables complete all as specified and directed.
M & L for Sand cushioning and covering with clean dry sand in trenches for protection of under ground cables (below, above and around the cable laid in trenches) complete all as specified and directed. (Note: Thickness after punning down shall be measured for payment)
Supply, laying, 40mm bore, Steel water tubing, galvanised, light grade with all fittings and fixtures for cable protection on road/drain/floor or for hangging ceiling fan etc including providing MS clamp, bolt, nuts complete all as specified and directed.
M & L Earthing complete with Galvanised steel earth plate electrode 600 mm x 600mm x 6 mm thick burried directly in ground vertically to a depth not less than 2.25 m below ground level with the top edge of earth plate at depth not less than 1.5 m below ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers protected by 15mm bore light grade GI pipe, funnel with 20mm bore GI medium grade pipe for watering, wire mesh, including concrete pit in PCC (1:3:6) type C-1, pre-cast RCC 1:2:4 type B-1 cover slab of size 350x350x50mm reinforced with 8mm dia TMT steel bars @15cm centre to centre in both direction and 10mm dia MS handle of suitable size, charcoal or coke and salt in alternative layers,necessary earth work in soft/loose soil all as shown in Electrical Plate No 3 of MES Schedule Part I and testing complete inclduing taking down old one as specified and as directed.
B5BUILDING SOLUTIONS
M/S Bhagyawanticonstruction
ANAND REFRIGERATION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .