Lekhraj Market-1st, IIIrd floor Indira Nagar Lucknow
Labour charges for 250 Capacity Auditorium for U.P. Sanskrit Sansthan New Hyadrabad, Lucknow. (Balance work)
2022_SCIDC_723677_1
218/E.E.(E)/Lko-III/E-PR/22-23
Open Tender
Electrical Works
Item Rate
60 days
Lucknow.
Labour charges for 250 Capacity Auditorium for U.P. Sanskrit Sansthan New Hyadrabad, Lucknow. (Balance work)
2 documents required · 2 mandatory
₹780
UPSCIDCo.ltd.
₹11,000
18 Oct 2022
27 Aug 2022
2 Sept 2022
27 Aug 2022
2 Sept 2022
27 Aug 2022
Amount
Labour Work
Labour Charges For Wiring point for light with 1.5 Sq. mm FR PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductor cable as earth wire drawn inside. continuity wire, Modular type switch & ceiling rose/angle/ batten holder on 3mm thick phenolic laminated backelite sheet etc. complete in all respect. with Modular Box & Cover plate.
Labour Charges For Wiring point for two way light with 1.5 Sq. mm F.R. PVC insulated multistrand single core copper conductor cable in PVC conduit Pipe with 1.5 Sqmm FRLSH PVC insuleted multistrand copper conductor cable as earthwire drawn inside the conduit. Modular type switches & ceiling rose/angle /batten holder on 3mm thick phenolic laminated backelite sheet etc. complete in all respect. with Modular Box & Cover plate.
Labour Charges For Wiring point for fan/fresh air fan (light duty exhaust fan) with 1.5 Sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductor cable as earthwire drawn inside the conduit, Modular type switch & ceiling rose on 3 mm. thick backelite sheet etc. complete in all respect with Modular Box & Cover plate.
Labour Charges For Wiring point for plug with 1.5 Sq. mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 Sq. mm FRLSH PVC insuleted multistrand copper conductor cable as earthwire drawn inside the conduit, Modular type switch & socket etc. complete in all respect with Modular Box & Cover plate.
Labour Charges For Wiring point for Exhaust Fan with 1.5 Sq.mm FRLSH PVC insulated multistrand single core copper conductor cable in PVC conduit with 1.5 Sq. mm FRLSH PVC insulated multistrand copper conductor cable as earthwire drawn inside the conduit. 15 Amp Modular type switch & ceiling rose on 3mm thick phenolic laminated backelite sheet etc. complete in all respects. with Modular Box & Cover plate.
Labour Charges For submains with two number 4 sq.mm FRLSH PVC insulated 1100 Volt grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2 mm thick) PVC conduit with one no. 2.5 sq.mm FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. complete in all respect.
Labour Charges For submains with two number 10 sq.mm FRLSH PVC insulated 1100 Volt grade multistrand single core copper conductor cable in 25 mm dia heavy duty (2 mm thick) PVC conduit with one no. 6 sq.mm FRLSH PVC insulated multistrand copper conductor cable as earth continuity wire drawn in conduit. complete in all respect.
Labour Charges for Fixing of 63 Amp 415 V metal clad T.P.N. rewireable type switch fuse unit on angle iron bracket complete in all respect. Cat-B
Labour Charges for Laying of Aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 6 sq.mm x 2 core.
16 sq.mm x 2 core.
16 sq.mm x 4 core.
35 sqmm x 3½ core.
120 sq.mm x 3½ core.
Labour Charges for burring of Safe Earthing Electrode T-19, (Hot Dip Galvanized), Length up to 3000 mm, Outer Dia 50 mm, inner Dia 25, terminal Dia 12 mm, outer G.I. pipe of 16 swg and inner G.I. pipe of 12 swg with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity and one earthing lead of 25 mm x 3mm G.I. strip upto switch board (from apron to switch board, the cost of G.I. strip will be extra) along with 30 cm square C.I. frame with hinged cover & masonry housing.
Labour Charges for Fixing of 6 Amp. To 32 Amp. SPMCB (10 KA) Cat-B
Labour Charges for Fixing of 50 Amp. to 63 Amp. SPMCB (10 KA) Cat-B
Labour Charges for Fixing of 63 Amp. DP MCB (10 KA) Cat.-B
Labour Charges for Fixing of 63 Amp 4 pole MCB - (10KA) Cat-B
Labour Charges For surface/flush mounting 12 ways SPN distribution board with additional metal door without MCB complete in all respect, as directed by Engineer in charge. Cat-B
Labour Charges For surface/Flush mounting 4 ways TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge. Cat.-B
Labour Charges for Fixing of surface/Flush mounting 4 ways V TPN distribution board with additional metal door without MCB complete in all respect, as directed at site by Engineer in charge. Cat.-B
Labour Charges for Fixing of surface/Flush mounting 4 ways V TPN distribution board with additional door without DPX3 160 MCCB complete in all respect, as directed at site by Engineer in charge. Cat.-B
Labour Charges for Fixing of surface/flush mounting 8 ways V TPN distribution board with addition metal door without DPX3 160 MCCB complete in all respect. as directed at site by Engineer in chardge. Cat-B
Labour Charges For Power plug with 20A/250 volt flush type modular switch and 5 pin 20A/250V flush type universal modular socket switch on concealed M.S. box including supply of all material, labour T&P etc. required for completion of work.
Labour Charges For submain with two number 1.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable in 20 mm dia heavy duty (2mm thick) PVC conduit with 1 nos. 1.5 sq.mm FRLSH PVC insulated 1100 V grade multistrand single core copper conductor cable as earth continuity wire drawn inside the conduite complete in all respect.
Labour Charges for Fixing of recess mounting round 15 watt to 18 watt LED Down Lighter having Powder coated die cast aluminium housing with heat sink, diffuser/Reflector and driver set complete in all respect. Cat AAA
Labour Charges for Fixing of 36 watt to 46 watt indoor recess mounting LED Square Fitting with support of Hanging system.
Labour Charges for Fixing of LED Tube Light with Metal heavy duty box type batten Light fitting 1 x 22 watt suitable for upto 1 x 22 watt LED Polycarbonate tube light complete including tube suitable for both surface & suspended complete in all respect.
Labour Charges for Fixing of LED Mirror Light Decorative type.
Labour Charges for Fixing of 18 W Sky Spot COB WW / NW / CW Hall fitting light.
Labour Charges for Fixing of LED fitting 3 watt waterproof.
Labour Charges for Fixing of 2 switch & 2 socket with modula box & cover plate.
Labour Charges for Fixing of 1 switch & 1 socket with modula box & cover plate.
Labour Charges for Fixing of Bus Bar 200 Amp.
Labour Charges for Fixing of 12 way SPNDB water proof Schenider Make.
Labour Charges for Fixing of Perforated Hot dipped Galvanised iron Cable Tray size 300 x 50 x 1.6 mm
Labour Charges for Fixing of Flood Light for Dome 40 to 50 watt Cat AAA
Labour Charges for Fixing of LED Ceiling Light 6 watt Crescent Make.
SANJAY ELECTRIC COMPANY
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .