GE Bharatpur
Kanjoli line Bharatpur
Repair and maintenance of certain MES installation different location in Mil Stn Bharatpur
2021_MES_495040_3
8099
Open Tender
Civil Works
Item Rate
270 days
GE Bharatpur
as per tender document
7 documents required · 7 mandatory
₹500
GE Bharatpur
₹54,000
Yes
18 Apr 2022
16 Feb 2022
14 Mar 2022
16 Feb 2022
12 Mar 2022
27 Feb 2022
17 Feb 2022 - 21 Feb 2022
60 days
Amount
Taking down chowkats or frames n. exc 1.5 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed.
Taking down chowkats or frames exc. 1.5 sqm but n. exc 4 sqm each with shutters (without taking off shutters from the frame) complete all as specified and directed.
Taking down shutters of any description exc 1 sqm and n. exc. 2 sqm each complete all as specified and directed.
Resecuring or easing adjusting without taking down shutter of any description exc 1 sqm and n. exc. 2 sqm each complete all as specified and directed.
S&F mild steel framed work such as grills, gratings, clamping etc., with ends of bars shouldered and/or riveted, or forged into spikes, framed guard bars, barred iron doors, door chowkats of angle or other section and similar works complete of Gde Fe-290 Gde E-165 including welding etc complete all as specified and directed.
S&F for 30 mm thick Flush Shutters, solid core construction, with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S&F 0.71 mm thick Plain, Aluminium sheeting, Alloy 31000 H4 in ridges, hips, valley gutter, drip and straight flashing (length and girth as fixed) complete all as specified and directed.
S&F sollid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheeet reinforced with MS square tube, fixing in opening complete all as specified and directed.
S&F 30mm thick factory made PVC panelled door shutter made out MS square tuble of min 19 gauge thickness and min 19mmx19mm for styles and 15mmx15mm for top and bottom rails MS frames to be given a coat of steel primer of approved make MS tube to be covered by PVC sections as under:- (I) Styles -`C' channels of thickness 5mm (min) size 30x75mm (ii) Top rail 5mm (min) thickness 75mm wide sheet on either side and 5mmx20mm cross PVC sheet. (iii) Bottom rail-5mm thick (min) x125mm wide sheet on either side and 5mmx20mm cross PVC sheet. (iv) Lock rail-5mm thick (Min) x75mm wide sheet on either side. Panelling sheet should be of min 5mm thick PVC sheet. The panelling sheet shall be fixed to the styles and rails with 5mm thick and 2mm thick PVC sheet beading. (v) Doors shall be Rajshsri Plasti wood or synteic or rotomould or rotomatic make (vi) The fixing of PVC Doors shall be all as per manufacturers instrs and ad directed
S&F in replacement Factory made steel windows with side hung shutters including box type hinges with steel handle of MS flat 25x5mm and 2 Nos steel tower bolts, 100mm long fixed to shutter complete with and including glazing bars, dovetailed or welded and also including with one shop coat of red oxide Zinc-Chromate primer complete all as specified and as directed.
Ditto as per ser No 10 but without glazing bars.
S&F 3.0 mm thick sheet glass ordinary quality and glazing with oil putty in square n exc 0.5 Sqm in each pane complete all as specified and directed.
S&F in repair Sheet glass 3.0mm thick, ordinary quality & glazing with oil putty in square n exc 0.5 sq.m in each pane including hacking out old broken glass (any thicknesss, size,quality or description) from metal frame inlcuding punching or drilling out old glazing pins/spring clips & providing & fixing new ones complete all as specified and as directed.
S&F 200mm long aluminium alloy, anodised, sliding door bolt with hasp, staple (bolt type) and fixing clips of sheet, cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast-aluminium alloy and fixed complete all as specified and directed.
S&F extruded aluminium alloy handle 150mm size fabricated type, anodised, ISI marked complete all as specified and directed.
S&F Aluminium anodised barrel tower bolts 150mm long of extruded section and fixed complete all as specified and directed.
S&F Aluminium anodised barrel tower bolt 200mm long of extruded section and fixed complete all as specified and directed.
S&F 100 mm butt hinges medium weight cold rolled mild steel, ISI marked, fixed to angle iron chowkats including welding complete all as specified and directed.
S&F 100 mm butt hinges extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, type B-21 complete all as specified and directed.
M&L for preparation of new or previously untreated steel surfaces of any description over 10 cm in width or girth with two coats of synthetic enamel paint over a coat of zinc chrome primer Complete all as specified and directed.
M&L Painting to new or previously untreated steel surfaces of any description over 10 cm in width or girth with two coats of synthetic enamel paint complete all as specified and directed.
M&L preparation of old painted steel surfaces of any description over 10 cm in width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
M&L for preparation of new wooden surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint. One coat of pink primer complete all as specified and directed.
M&L for preparation of old painted wooden surfaces of any description not otherwise described over 10 cm width or girth and applying one coat of synthetic enamel paint complete all as specified and directed.
Demolition of brickwork or stone boulder masonry built in cement mortar or cement lime mortar including all quoins, arches, pillars etc complete all as specified and as directed by Engineer-in-Charge. Complete all as specified and directed.
Removing cement or cement lime mortar from and cleaning stones, obtained from masonry of any description (except ashlar facings and dressed stone work) and stone setts from pavings; stacking for measurements including all extra handling and removal and disposing off rubbish complete all as specified and directed.
M&L Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in CM (1:6) but except stone complete all as specified and directed.
Brickwork with sub-class ‘B’(old size) burnt clay bricks straight or curved on plan exc 6 metre mean radius built in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for PCC (1:4:8) type D-2 using 40mm graded stone aggregate in foundation, filling and mass concrete complete all as specified and directed.
Dismantling Stone slabs in roofs, suspended floors, chajjas, landings, etc., any thickness, jointed in any mortar complete all as specified and directed.
M&L for 100 mm thick Sand stone slabs in sunshades, chajjas, shelves, cills, landings, cover stones, templates, etc, n exc. 2m in length, punched dressed on face and along exposed edges, self faced on other side and set and pointed in cement mortar 1:4, complete all as specified and directed.
S&F Rolled mild steel in Joist, channel, angle, or tee sections, fixed independently, without connecting plates, etc. (cut to ordinary lenghts i.e. within 20mm of the length indicated) of Fe-290 (Gde E-165) complete all as specified and directed.
Taking down cement plaster or cement lime plaster on PCC / stone surface / brick surfaces including raking out joints hacking for key scrubbing down with water including removal to debris to a distance n. exc 100 m and deposited where complete all as specified and directed.
M&L for Rendering 15 mm thick in two layers i.e 1st layer of 10 mm thick in CM (1:6) and 2nd layer 5 mm thick in CM (1:4) mixed with water proofing compound @ 3% by weight of cement on stone masonry surfaces or surfaces other than fair face of brick wall or concrete surface finished even.& smooth without using extra cement. (Note :- WPC shall be measured and paid for seperately under respective item) complete all as specified and directed.
Supply only integral water proofing compound ISI Marked complete all as specified and as directed.
M&L for rendering 15 mm thick in cement mortar (1:6) on stone masonry surfaces or surface other than fair face of brick work of walls, finished even & smooth without using extra cement complete all as specified and directed.
M&L for rendering 10 mm thick in cement mortar (1:3) on concrete surfaces including finished even & smooth without using extra cement on ceiling complete all as specified and directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of cement base paint of approved shade over a coat of alkali resistant primer complete all as specified & directed.
M&L for preparation of new plastered surfaces of walls by washing, rubbing down & applying two coats of distemper oil emulsion of approved shade/tint over a coat of 1 mm thick birla wall care putty on wall surface complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying three coats of white wash on wall surface complete all as specified and directed.
M&L for preparation of newly plastered surfaces and applying three coats of white wash on ceiling surface complete all as specified and directed.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of oil bound distemper of approved shade/tint over a coat of 1mm thick birla wall care putty on walls complete all as specified and directed.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of cement base paint over a coat of alkali-resistant primer of approved shade on walls complete all as specified and directed.
M&L for preparation of old plastered surfaces and applying a coat of white wash on wall surface including preparation of surface complete all as specified and directed.
M&L for preparation of old plastered decorated surfaces and applying a coat of white wash on ceiling surface complete all as specified and directed.
Dismantling floor, hearth or wall tilling incl cement mortar beding (but not backing), removing serviceable tiles to store and rubbish off the premises as complete all as specified and directed.
S&F non skid ceramic coloured tiles 7 to 8mm thick (square/rectangular) area of each tile exc 0.06 sqm but n.exc 0.11 sqm, in floors etc. over 15mm thick screed bed in CM 1:6 and set and jointed in neat slurry and pointed in white or coloured cement to match complete all as specified and directed.
M&L Glazed ceramic joint free coloured/printed tiles in vertical surface of size 350x250x7 mm / 450x350x7 mm thick set and jointed in neat cement slurry over 15mm thick rendering in cement mortar (1:4) and pointed in white or colour cement to match the colour of tiles complete all as specified and directed.
M&L for Vitrified Ceramic tiles light shade 10mm thick (square/rectangular) polished, area of each tiles not exceeding 0.36 sqm, in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match incl 15mm thick screed bed or bedding layer of cement and sand mortar (1:6) for laying floor finishes complete all as specified and directed.
M&L for Vitrified tiles in skirting/dado 10 mm thick, over 10mm thick rendering in CM 1:3 complete all as specified and directed.
M&L for Chequered cement concrete tiles 20cmx20cmx25mm thick with grey cement and pigment incl 15mm thick screed bed or bedding layer of cement and sand mortar (1:6) set, jointed and pointed in neat cement slurry in floors complete all as specified and directed.
M&L for Machine cut kota stone slab flooring 20-25mm thick over 20mm thick cement screed bed in CM (1:3) laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete all as specified and directed.
M&L for 12-16 mm thick machine cut kota stone slab as in riser of steps, skirting, dado and pillar laid over 10mm thick rendering in CM 1:3 complete all as specified and directed.
Demolition of cement concrete (un-reinforced) in ground floors and pavings n exc. 15 cm thickness (below or above ground level) complete all as specified and as directed.
M&L for 75 mm thick Cement concrete type D-2, 1 : 4 : 8 (using 40mm graded stone aggregate) as in sub floors/sub bases etc. finishing surface even and rough to recieve the topping layer complete all as specified and as directed.
M&L for 75 mm thick Cement concrete type B-2, 1 : 2 : 4 (using 40mm graded stone aggregate) as in floors etc. and finishing cement concrete surface even and fair complete all as specified and as directed.
M&L for broken stone or boulders in hardcore of gauge n exc. 63 mm, deposited, spread and levelled in layers n. exc. 15 cm thick, watered and rammed to a true surface complete all as specified and as directed.
M&L for 100 mm thick Cement concrete type B-2, 1 : 2 : 4 (using 40mm graded stone aggregate) as in floors etc. and finishing the surface of concrete pavement by brooming complete all as specified and as directed.
M& L forming Contraction (Dummy) joints 65 mm deep x 10mm wide, filled with sealing compound, grade 'A' complete all as specified and directed.
M& L forming 20mm thick Expansion joints filled with pre-formed bituminous filler and top 30mm primed and sealed with sealing compound, Grade `A', thickness of concrete slab 100 mm complete all as specified and directed.
M&L for 25 mm thick sand cushioning below interlocking paver block complete all as specified and directed.
M&L for 60 mm thick (M-35 grade) machine pressed precast concrete interlocking paver block with grey cement and no pigment conforming to IS 15658-2006 of shape and size as complete all as specified and directed.
M&L for 80 mm thick (M-40 grade) machine pressed precast concrete interlocking paver block with grey cement and no pigment conforming to IS 15658-2006 of shape and size as complete all as specified and directed.
M&L for 75 mm thick Cement concrete type C-2, 1 : 3 : 6 (using 40mm graded stone aggregate) as in plinth protection finished even and smooth (without using extra cement) complete all as specified and directed.
Taking up or down steel tubing and connections, including cleaning for re-fixing or removal to store complete all as specified and directed of following sizes:- 65.01 15 mm bore
20 mm bore
25mm bore
Refixing old steel tubing and connections in new or old position (Walls, ceiling, floors, etc.) complete all as specified and directed. 66.01 15 mm bore
20 mm bore
M&L for galvanised steel water tubing medium grade with all fittings and fixed complete to walls and ceilings or laid in floors complete all as specified and directed.of following sizes :- 67.01 15 mm bore
20 mm bore
25mm bore
S&F fancy type chromium plated bib tap, cast copper alloy, with crutch or butterfly handle, screwed down, screwed for iron pipe or for brass ferrule of 15mm bore, fixed in repairs complete all as specified and directed.
Taking down the existing unserviceable stop valve and S&F 15 mm bore stop valve, cast copper alloy, screwed down, high pressure with crutch or butterfly handle screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
Ditto, but fancy type, chromium plated CP fancy type stop valve/ Angle valve 15 mm bore with long shank and cup (concealed type) complete all as specified and directed.
S&F in repair 15 mm bore CP Angle stop valve fancy type screwed both ends for iron pipe or for unions and fixed complete all as specified and directed.
S&F PVC low level flushing cistern 10 ltrs capacity with inlet ball valve float & handle, syphonic action type including brackets & flush pipe of polythelene of low or high density or PVC 32mm dia for LLFC fixed in repairs complete all as specified and directed.
Demolition of old existing unserviceable Indian type WC and S & F vitreous china squatting pan, 'Orissa' pattern, size 580x440 mm white, with integral foot rests, 'P' or 'S' trap, including connection to trap, and to flushing pipe, anti-syphonage pipe.Complete making good to floor with PCC,Lime concrete bedding complete all as specified and as directed.
S&F in repair aluminium anodised tubular towel rail, 20mm dia 60cm long complete all as specified and directed.
S&F in repair MS chromium plated grating 75/100mm dia for floor trap / Nahani trap complete all as specified and directed.
S&F 75 mm dia PVC (SWR) floor trap, plain with grating including jointing with solvent cement complete all as specified and directed.
S&F 110 mm dia PVC (SWR) 'P' trap complete all as specified and directed.
S& F in repair pillar tap, cast copper alloy with capstan heads,chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks & fly nuts, screwed for iron pipes of 15mm bore complete all as specified and directed.
S&F vitreous china wash hand basin white of size 550x400mm flat back excluding taps, waste, chain and plug but including brackets including cutting for and pinning in ends of brackets or erecting stand complete in repairs complete all as specified and directed.
S & F 32 mm waste coupling of PTMT (half or full threaded) Minimum weight 32mm-45gms) complete all as specified and directed.
S&F 32 mm dia low density polyethylene pipes for wash basin waste pipe connection etc complete all as specified and directed.
S&F in repairs Soap dish, Vitreous China white, approximate size 160x160x90mm complete all as specified and directed.
S&F in repairs Brass CP shower rose 125mm size with of without swivel joints and fixed to steel pipe or union complete all as specified and directed.
S&F PVC connection 15 mm size with PTMT nuts of length 450 mm long complete all as specified and directed.
Dismantling water tank exc 250 ltr but nexc 500 ltr complete all as specified and directed.
S&F Rotational moulded polyethylene water storage tanks of cap 500 Ltr white colour with threaded cover, tripple layer (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR part - I and complete all as specified and directed.
S&F Nipple 25mm bore suitable for HDPE water tank. (min. weight 25mm-65gms) complete all as specified and directed.
S&F 20mm bore Ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as specified and directed.
S & F Rotational moulded polyethylene water storage tank of 5000 Ltr capacity white colour with threaded cover, tripple layer (cylinderical vertical with closed top) hoisted and fixed in position all as specified in SSR part - I and complete all as specified and directed.
M&L for Cement concrete 1:2:4 type B-2 (using 40mm graded stone aggregate) as in foundations of water storage tanks etc. complete all as specified and directed.
M&L for greasing and easing of rolling shutter of size not exc 13 Sqm alongwith the guide channel, helical spring, anchoring rod and all other as to work the shutter in easy way complete all as specified and directed.
S & F Ball bearing for rolling shutters complete all as specified and complete all as specified and directed.
S& F for RMP sheeting 1:5 mm thick with 1:5 corrugation side lap fixed with coach screw and PVC washer in roof, wall etc complete all as specified and directed.
Dismantling posts or struts (wood, steel or R.C.C.) embedded in concrete, brick work, masonry, etc. any section, including taking out embedded portion and making good disturbed ground complete all as specified and as directed.
Dismantling fencing wire mesh, any type complete all as specified and directed.
Excavation in post holes each n. exc .50 cum, getting out in soft/loose soil and removing surplus material n. exc 50 mtr and making good disturb surfaces complete all as specified and directed.
M&L for PCC 1:3:6 type C2 using 40mm graded crushed stone aggregate as in foundation of posts and struts, foundation, filling and mass concrete etc.complete all as specified and directed.
S&F Mild steel work of Fe-290 Gde E-165 as in angle iron fencing posts and struts & flat iron, drilled and countersunk for boulders running bars, including embedding in concrete and screwing etc. wind ties for roof including securing bolts; post and struts in fencing including cutting, tops to shape as directed, bent to shape, drilling holes, notching for wire etc. flat iron fillets (for securing wire mash etc.) including all necessary drilling, bolting or riveling etc. complete all as specified and directed.
S & F Mild steel Round bars conforming to Fe 290 (Gde-E-165) 10mm dia and over as in horizontal vertical fillets in fencing including hooking complete all as specified and directed.
Supply only Chain link MS galvanised fencing, any size or type complete all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts etc. including provission of binding wire complete all as specified and directed.
S&F Mild steel screw bolts (machine made) of 10mm dia and 50mm long with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut complete all as specified and directed.
Dismantling of Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
S&F 6mm thick asbestos cement, corrugated or semi-corrugated shets in roofs, walls, etc. fixed with L-type or J-type or cranked hook bolts complete all as specified and as directed.
S&F 6 mm thick asbestos cement two piece adjustable close fitting corrugated ridge in roofs fixed with L-type or J-type or cranked hook bolts complete all as specified and as directed.
Material and labour for renewal of earthing complete with galvanized iron earth plate electrode 600 mm x 600 mm x 6 mm thick buried directly in ground (earth pit not less than 2.25 m deep below normal ground level) with top edge of the plate not less than 1.5 m deep below normal ground connected to galvanised GI strip of size 32 x 6 mm by means of bolts nuts check nuts and washer of galvanized steel, watering pipe of 20 mm bore galvanised iron medium grade and 40 mmbore galvanised iron light grade for earth strip protection including all excavation earth work in any type of soil, PCC pit in PCC 1:2:4 type B-1 and RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), with charcoal, salt, funnel complete all as shown in the electrical plate No 3 of SSR part –I and testing on completion complete all as specified and directed. Note:-Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length.
Material and labour for replacement of unserviciable existing earthing with bore well earthing with the help of mechanical boring machine of 150 mm dia-30 mtr depth supply and fix 160 mm dia (O.D), UPVC pipe 6 kg/sqcm rating -06 mtr long with the help of suitable size clamp with nut bolt and washer -01 No including charcoal dust ,salt fill in bore well for earth conductivity M&L for covering of bore well with PCC (1:2:4) type B-1 / Brick masonry pit of size 45x45x45 cm complete and give the minimum earth test result below 1 ohm complete all as specified and directed by Engineer-in-charge. Note :- (i) The earth pit shall be refilled by boulders free from vegetable soil.(ii) Earthing shall be tested by contractor in presence of Engr-in-charge.Record shall be maintained.Payment shall be admissible only after satisfactory test results.
Supply & fixing in replacement of GI tubng 50 mm dia medium grade incl necessary fittings for lowering in borewell of depth upto 30 mtr and grouting at roof top in cement concrete to mount the air termination rod complete all as specified and directed.
Material and labour for renewal of chemical earthing complete with copper earth plate electrode of size 900 mm x 600 mm x 3 mm thick buried directly in ground (earth pit not less than 4.00 m deep below normal ground level) with top edge of the plate not less than 2.95 m deep below normal ground connected to and including copper earth strip 32 mm x 6 mm by means of copper bolts nuts check nuts and washer, returning & filling the pit with excavated soil mixing with charcoal 250 KG, Crystal salt 200 KG, magnesium sulphate of 100 KG and vegetable soil all around the plate up to 350 mm above from top edge of plate and balance portion filling with excavated soil in layers not exceeding 25 mm thick, 25 mm bore galvanised iron medium grade watering pipe up to top of plate, 50 mm bore galvanised iron light grade pipe for earth strip protection, including all excavation earth work in any type of soil, PCC 1:3:6 type C1 for chamber of internal size 300 mm x 300 x 300 mm with 120 mm thick wall and 700 mm x 700 mm x 150 mm thick bed concrete, RCC 1:2:4, type B1 for precast chamber cover 50 mm thick, reinforced with welded steel wire fabric or XPM Jali (weight not less than 4.00 Kg / sqm), funnel, with wire mesh, complete all as specified and directed.Note:- (i) Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length.
S & F copper strip of size 20 x 3 mm fixed on wall/ roof with saddles and fixing on porcelaine insulator & screw etc for earth continuity conductors as continues earth strips from copper rod to test point terminal complete all as specified and directed.. roof conductor and down conductors above ground level.
Supply only Earthing Soil Resistivity improvement compound Gel, Enhancement compound Transparent Liquid Jel in 5 Kg packing complete all as specified and directed. Make -JJ Engineering / JMV LPS Ltd / SM Infotech / Powertack
Supply & fixed in repair MCCB 63 Amp, 4 Pole, fixed type breaking capacity 18 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified and directed. Make : L&T/ABB/Legrand
Supply & fixed in repair MCCB 100 Amp, 4 Pole, fixed type breaking capacity 18 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed. Make : L&T/ABB/Legrand
Supply & fixed in repair MCCB 125 Amp, 4 Pole, fixed type breaking capacity 25 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed. Make : L&T/ABB/Legrand
Supply & fixed in repair MCCB 160 Amp, 4 Pole,adjustable type breaking capacity 25 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed. Make : L&T/ABB/Legrand
Supply & fixed in repair MCCB 200 Amp, 4 Pole,adjustable type breaking capacity 36 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed. Make : L&T/ABB/Legrand
Supply & fixed in repair MCCB 250 Amp, 4 Pole,adjustable type breaking capacity 50 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed. Make : L&T/ABB/Legrand
Supply & fixed in repair MCCB 400 Amp,4 Pole,adjustable type breaking capacity 50 KA, 415 V - 50 Hz, fixed in existing panel & connecting complete all as specified & directed. Make : L&T/ABB/Legrand
Supply and fix in repair GI earth strip of size 32 x 6 mm fixed on wall over and including epoxy insulators and fixing screws etc for earth continuity conductors to test point terminal block complete all as specified & directed.
S&F in repair LED type building security light of capacity 30 watt of white light with driver, having luminaries Efficiency not less than 100 lm / Watt, fixed in Pressure Die Cast Aluminum housing, & glass cover, Ingress protection of IP 65, including all necessary fitting & fixture,& connecting complete all as specified & directed. Make : Crompton / ABB / Wipro
S&F in repair street light bracket fabricated from 40 mm bore galvanised iron tubing light grade, 1.2 metre long, bent to shape fixed on pole / bldg including mild steel flat iron clamps, nuts, bolts etc including taking down old bracket from existing position complete all as specified & directed.
Supply & laying 40 mm bore mild steel galvanised iron tubing light grade for protection of cable / earth continuity conductor etc, fixed to poles / wall with clamp nut bolt etc / laid on roof or laid on floors, road, crossing or ducts etc, including taking down old tubing complete all as specified & directed.
Supply & laying 50 mm bore mild steel galvanised iron tubing light grade for protection of cable / earth continuity conductor etc, fixed to poles / wall with clamp nut bolt etc / laid on roof or laid on floors, road, crossing or ducts etc, including taking down old tubing complete all as specified & directed.
Excavation in trenches not exc 1.5m wide and n.exc 1.5m in depth for foundation / fixing pole / laying cable and pipe line etc or for man hole etc not exc 10 sqm on plan and getting out in soft / loose soil complete all as specified & directed.
Returning filling in including spreading levelling, watering and well ramming in layers not exc 25 cm thick using suitable excavated soil complete all as specified & directed.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
M&L for providing dry river sand as in sand cushioning below and above cable thickness as specified in SSR to under ground cable including punning down of sand in layer all as specified and directed. Note: for measurement purpose punned thickness of sand will be consider.
M & L for brick protection with sub class B bricks old size laid dry, flat over cable perpendicular across the cable in trenches complete all as directed.
Supply testing and commissioning lay, UG XLPE insulated armoured heavy duty electric cable with Aluminium conductor 1100 V grade laid in trenches / passing through GI tubing / on pole / on wall etc. all as directed & specified of following sizes. 130.01 16 Sqmm 4 core
25 Sqmm 4 core Note for Item No 130.01 and 130.02 (i) Earthwork, sand cushion, cable cover will be measured and paid separately under respective items of this Schedule.(ii) Straight through joint will be measured and paid separately.
Supply and fix MCB’s triple pole & neutral, 32 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting complete all as specified and directed.
Supply and fix MCB’s triple pole & neutral, 63 Amps, 415 volts with ‘C’ curve, fixed in sheet metal board complete including connecting complete all as specified and directed.
M&L for Danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and fixed with MS clamps, bolts and nuts of approved size, for LT, 25X20 cm size complete all as specified and directed.
Material and Labour for cleaning of dust particles from inside the LT Panel by air blowers, tightening of loose connections, filling of gaps with sealants, removing of vegetation, surface dressing surrounding the panel, welding of damaged panel doors, fixing of hinges, providing locking arrangements, painting of panel with two coats synthetic enamel paint of existing colour complete including providing lock complete all as specified and directed.
RAJEEV CONSTRUCTION
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .