Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.5 LAccepted-AOC | L1 | Accepted-AOC Accepted being Lowest. | |
| 2 | L2₹24.8 L+₹2.4 L (10.6%)Rejected-Finance VILLAGE HARIGAON PO PS NIKAMUL SATRA TEZPUR DIST SONITPUR ASSAM | L2 | Rejected-Finance Rejected, being not lowest. | |
| 3 | L3₹26.3 L+₹3.9 L (17.2%)Rejected-Finance | L3 | Rejected-Finance Rejected, being not lowest. | |
| 4 | L4₹27.8 L+₹5.3 L (23.7%)Rejected-Finance | L4 | Rejected-Finance Rejected, being not lowest. | |
| 5 | Rejected-Technical | - | Rejected-Technical NO as per WLR. |
Tender Value
₹24 L
EMD Value
₹48,000
Closing Date
26 May 2020, 6:00 pmClosed
GE(P)WEST
GE(P)WEST DELHI CANTT DELHI 110010
CANO GE(P)WD-01/2019-2020 PROVN OF FOOTBALL GROUND, BASKET BALL COURT AND UG SUMP NEAR TRANSITCAMP, UNDER GE(P)WEST, DELHI CANTT.
2020_MES_318748_2
CANO GE(P)WD-01/2019-2020
Open Tender
Civil Works
Item Rate
120 days
DELHI CANTT
Please refer Tender documents.
7 documents required · 7 mandatory
₹500
GE(P)WEST, DELHI CANTT
₹48,000
Yes
13 Jul 2020
24 Mar 2020
28 May 2020
24 Mar 2020
26 May 2020
7 Apr 2020
24 Mar 2020 - 31 Mar 2020
Amount
Surface excavation in any type of soil n.exc (not exceeding) 30 cm deep and averaging 15cm deep and getting out, all as specified.
Excavating over areas, n exc 1.5 m deep and getting out in any type of soil, all as specified.
All as per item No 2 but exc 1.50 m deep and n.exc 3.00 m deep.
All as per item No 2 but exc 3.00 m deep and n.exc 4.50 m deep.
Excavation in trenches in any type of soil , n.exc 1.5m wide and n.exc 1.5m in depth and getting out ,all as specified and directed.
Returning, filling in, incl spreading levelling , well ramming and watering in layers n. exc 25 cm, all as specified.
Removing excavated surplus material to a distance not exc 50m and depositing where directed at a level not exceeding 1.5m above the starting point.
Rolling and consolidating formation surfaces in cutting with 8 tonne to 12 tonne power roller, all as specified.
Galvanised seel tube including fittings , 100mm bore, medium grade, fabricated for making football goal post as per standards, all as directed .
Full size nylon wire net for football goal post, of mesh size 25mm to 50mm, as per standrad, all as specified. Make: Balaji or equivalent, as approved.
Hardcore of broken stone or boulders of gauge n exc. 63 mm, deposited, spread and levelled in layers n exc. 15 cm thick, watered and rammed to a true surface , all as specified.
PCC (1:4:8) type D-2 (using 40mm graded crushed stone aggregate) as in foundation etc, complete as as specified and directed.
Plain Cement concrete 1:3:6 type C1 , using 20 mm graded crushed stone aggregate, as in foundations, filling and mass-concrete, all as specified.
75mm thick PCC 1:3:6 type C-1 (using 20mm graded stone aggregate) as in plinth protection finished even and smooth w/o using extra cement including forming and filling of 12mm joints with bituminous filler, all as specified.
100 mm thick PCC 1:3:6 type C-2 using 40mm graded crushed stone aggregates as in sub base , laid in bays including necessary formwork, complete all as specified.
100mm thick PCC 1:2:4 type B-2 using 40mm graded crushed stone aggregates as in flooring, laid in alternate bays including necessary formwork, finishing surface even and smooth, complete all as specified.
Basket ball pole, mild steel , of standard size, with all accessories like acrylic board,stainless steel rind, net etc,including fixing in ground ,complete all as directed. Make: SNS/Deluxe/Balaji/SKM
Forming Contraction (Dummy) joints 65mm deep x 10mm wide, filled with sealing compound grade "A", all as specified.
Reinforced cement concrete M-30 design mix concrete using 20mm graded crushed stone aggregate as in foundations including raft, footings, foundation beams, plinth beam etc, using water proofing compound , all as specified . (Note: W.P.C shall be measured and paid for separately)
Reinforced cement concrete M-30 design mix concrete using 20mm graded crushed stone aggregate as in columns, pillers, piers, posts and struts, using water proofing compound , all as specified . (Note: W.P.C shall be measured and paid for separately)
Reinforced cement concrete M-30 design mix conc using 20mm graded crushed stone aggregat as in Walls, retaining walls of any thickness above top of footings including attached pilasters and buttresses, using water proofing compound , all as specified . (Note: W.P.C shall be measured and paid for separately)
Reinforced cement concrete (design mix) M-30 as in Slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and the like, using water proofing compound , all as specified . (Note: W.P.C shall be measured and paid for separately)
TMT steel bars 10mm dia and above , cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) all as specified and directed.
TMT steel bars 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders cut to length, bent to shape required including cranking, bending spirally or hooping for columns, hooking ends and binding with MS wire (annealed not less than 0.9mm dia) all as specified and directed.
Form work to sides of concrete foundation, footing bases of coloumn, rafts and raft beam, sides & soffits of foundation and plinth beams /similar work, vertical or to batter for fair finished surfaces of concrete, all as specified .
Formwork to faces of columns, etc. vertical or to batter for fair finished, all as specified.
Formwork to faces of walls, retaining walls, abutments, parapets and staircase railings and similar work including attached pillasters, buttresses, etc. vertical or to batter for fair finished, all as specified.
Formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work not exceeding 200mm thick, for fair finished, all as specified.
Formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20 cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, for fair finished, all as specified
Brickwork with sub class 'B' bricks, straight or curved on plan exc 6m mean radius, built in cement mortar 1:4 , complete all as specified.
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 ,finished even and smooth without using extra cement, in isolated locations, all as specified .
Rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 ,finished even and smooth without using extra cement, using water proofing compound , all as specified . (Note: W.P.C shall be measured and paid for separately).
Rendering 5mm thick plaster in cement mortar 1:4 on fair faces of concrete surfaces , finished even and smooth without using extra cement complete, using water proofing compound , all as specified . (Note: W.P.C shall be measured and paid for separately)
Rendering 5mm thick plaster in cement mortar 1:4 on fair faces of concrete surfaces , finished even and smooth without using extra cement complete,including floating and setting coat , all as specified . (Note: W.P.C shall be measured and paid for separately)
Supply only integral water proofing compound , all as specified.
Preparation of new plastered or unplastered surfaces of walls and applying two coats of cement base paint over a coat of primer complete, all as specified.
Painting lines, dashes, arrows, letters, etc. on concrete surfaces, pavements and the like exc 10 cm wide with road marking paint, white or golden yellow , all as specified.
Painting lines, dashes, arrows, letters, etc. on concrete surfaces, pavements and the like , not exc 10 cm wide with road marking paint, white or golden yellow , all as specified.
Preparation of new steel and iron surfaces of any description exceeding 10 cms in width or girth and applying two coats of black japan paint over one coat of red oxide zinc chrome primer, all as specified.
Preparation of new steel and iron surfaces of any description exceeding 10 cms in width or girth and applying two coats of synthetic enamel paint over one coat of red oxide zinc chrome primer, all as specified.
Steel water tubing ,medium grade of nominal bore dia 150 mm galvanised with all fittings including short lengths, fixed to walls, concealed in wall and ceiling or laid in floor complete with all fittings( such as bends, elbows, Tee, short pieces, connectors, back nuts, diminishing pieces, caps and plugs, unions etc.) , all as specified
PVC water stop bar, minimum 250mm wide,fixed at every construction joint of RCC wall, conforming to IS-15058:2002, all as specified and directed.
Framed work such as grills ,gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways ;railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165, all as specified.
R R ENTERPRISES
Sanjay Associates
M/S R.S. Builders
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .