| 1 | L1₹26.0 LAccepted-AOC NO 7 3RD MAIN ROAD MUNI REDDY LAYOUT HORAMAVU MAIN ROAD BANASAWADI BANGALORE 560043 | BENGALURU URBAN | KARNATAKA | 560043 | ₹26.0 L Quoted ₹26.7 L | L1 | Accepted-AOC L1 |
| 2 | L2₹26.9 L+₹19,836.46 (0.74%)Rejected-AOC | ₹26.9 L+₹19,836.46 (0.74%) | L2 | Rejected-AOC L2 |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
9 Dec 2023, 6:00 pmClosed
GE (AF) Yelahanka
GE (AF) Yelahanka Bangalore-63
MAINTENANCE AND REPAIRS TO LT SYSTEM AND CONNECTED ITEMS AT AFS YELAHANKA AND COMPREHENSIVE MAINTENANCE OF 1MWp SOLAR POWER PLANT AT AF STN YELAHANKA
2023_MES_627072_1
8204/E8
Open Tender
Civil Works
Item Rate
330 days
GE (AF) Yelahanka
As per NIT
9 documents required · 9 mandatory
₹500
GE (AF) Yelahanka
₹60,000
Yes
20 Jan 2024
6 Nov 2023
16 Dec 2023
6 Nov 2023
9 Dec 2023
20 Nov 2023
Amount
Excavation in trenches not exceeding 1.5 m wide and not exceeding 1.5 m deep for laying of cables, pipes, foundation for poles etc., and getting out in hard/dense soil all as specified and as directed.
Returning filling in excavated soil upto a depth of 30 cm after riddling of excavated soil (in lieu of sand) for cushioning of cable and refilling of trenches with left over normal excavated soil including spreading, leveling, watering and well ramming in layers complete all as specified and as directed by Engr-in-Charge.
Removing surplus soil to a distance not exceeding 50 m and depositing where directed at a level not exceeding 1.5 m above the starting point as directed.
Supplying and laying un-reinforced precast concrete cable cover, class LV, Type 1 with peak, size250 mm x 150mm x 40mm all as specified and as directed.
Supply and laying in trenches, LT underground cable of size 16 Sqmm 4 core XLPE insulated armoured and PVC sheathed 1100 Volts grade with aluminium conductor multistranded including cable connecting lugs, glands,jointing materials etc., laid in trenches, floors, roof, ducts and fixing using clamps, saddle for pole, wall including taking down complete all as directed by Eng-in-Charge
All as per item No 5 here-in-before but 25 Sqmm 3.5 core
All as per item No 5 here-in-before but 35 Sqmm 3.5 core
All as per item No 5 here-in-before but 50 Sqmm 3.5 core
All as per item No 5 here-in-before but 70 Sqmm 3.5 core
All as per item No 5 here-in-before but 95 Sqmm 3.5 core
All as per item No 5 here-in-before but 120 Sqmm 3.5 core
All as per item No 5 here-in-before but 240 Sqmm 3.5 core
All as per item No 5 here-in-before but 300 Sqmm 3.5 core Note : For Sl No 5 to 13, necessary excavation and connected items shall be measured and paid separately under respective items of this schedule.
M & L for boring of holes under roof, pavement, hardstanding by trenchless technology and necessary machine including HDPE pipe of 75mm dia suitable for 0.4mpa working pressure complete all as specified and directed.
Supply and laying GI tubing light grade 50mm dia in trenches/fixing on pole /wall/crossing in drain etc.for protection of UG cable complete all as specified and directed
Supply and laying GI tubing light grade 80mm dia in trenches/fixing on pole /wall/crossing in drain etc.for protection of UG cable complete all as specified and directed.
S & F danger notice plate of 1.6mm thick mild steel sheet, vitreous enameled white with letters figures and conventional skull and bones in signal red colour and fixed with MS clamps bolts and nuts of approved size for LT, 20x15cm size including taking down old unserviceable one complete all as specified and directed.
Supply and fix in repair 40 to 100 Amp rating, 415V, 10KA 'C' curve miniature circuit breaker (MCB) of four pole in the MCB DB complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair 32 Amps rating, 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of Single Pole and Neutral, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair 240V, 10 KA 'B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning complete all as specified and directed by Engr-in-Charge.
Supply and fixing of PVC spacers for 4 wire LT 1100 Volts grade overhead line all as directed.
Supply and fixing of PVC spacers for 2 wire LT 1100 Volts grade overhead line all as directed.
Supply and fix cable route indicator made out of 3 mm thick MS sheet of size 20 cm x 15 cm duly painted with two coats black paint over a coat of red oxide primer and writing cable direction, capacity, size of cable with white paint, mounted on angle iron 40x40x3 mm, angle height 45 cm, (30cm below ground level) with PCC 20cmx20cmx15cm all as specified and as directed by Engineer- in- charge.
Supply, installation and commmissioning in repair LT out door loop in loop out terminal box with sloping canopy of size 600x450x250mm made out of 3 mm thick CRCA sheet duly painted with two coars of syntehtic enamel paint over a coat of rex oxide, front and rear hinged doors mounted on 40x40x6 mm MS angle iron frame 90 cms height erected in ground with PCC foundation 1:4;8 with 40mm stone aggregate including supply and fixing insulated aluminium bus bar of size 50x 6mm for three phase and neutral 200mm length respectively mounted on insulators and terminating with suitable cable with glands and provision of one MCCB 63 Amps 4 pole ,415 Amps, 50 Hz of breaking capacity 16 KA as incomer including taking down old terminal boxes complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair bus bar box of size 450x300x500mm fabricated by 3 mm thick MS sheet outdoor type, dust/vermin proof, mounted/fixed on angle Iron frame of MS equal angle size 40x40x6mm of height 0.90 mtr, erected in ground with PCC foundation 1:4;8 with 40mm stone aggregateand including aluminium bus bar flat of size 50x6 mm fixed as bus bar over the insulators, sleeved for three phase and neutral and spray painting the box with two coats of enamel paint over a coat of metal primer including necessary excavation, PCC for fixing the box complete all as specified and directed by Engr-in-Charge.
Supply and jointing straight through joint outdoor type 1100 volts grade heat shrinkable type suitable for 3.5x 25 sqmm to 3.5x 95 sqmm LT XLPE cable and testing after jointing complete all as specified and as directed by Engr-in-charge.
Supply and jointing straight through joint outdoor type 1100 volts grade heat shrinkable type suitable for3.5x 120 sqmm to 3.5x 240 sqmm LT XLPE cable and testing after jointing complete all as specified and as directed by Engr-in-charge.
(a) 1.5M x 1.0M x 0.45M
(b) 1.25M x 1.0M x 0.30M
(c) 1.0M x 0.75 x 0.30M
Supply only CTs suitable for existing LT panel board of capacity 400 to 630 Amps all as specified and as directed.
Supply only CTs suitable for existing LT panel board of capacity 250 to 320 Amps Amps all as specified and as directed.
Supply only CTs suitable for existing LT panel board of capacity 63 to 200 Amps Amps all as specified and as directed.
Supply only LED indicator lamps (R Y B ) suitable for existing panel all as pecified and directed.
Supply only MCCB 400 Amps, 4 pole 415 Volts,50 Hz,36 KA adjustable thermal setting type and corfirming to IEC 60947-II complete all specified and directed by Engr-in-Charge. Make : Indo Asian, Cat No : 830396 or its techno commercial equivalent.
Supply only MCCB 315 Amps, 4 pole 415 Volts,50 Hz,36 KA adjustable thermal setting type and corfirming to IEC 60947-II complete all specified and directed by Engr-in-Charge. Make : Indo Asian, Cat No : 830395 or its techno commercial equivalent.
Supply only MCCB 200 Amps, 4 pole 36 KA adjustable thermal setting type and corfirming to IEC 60947-II complete all specified and directed by Engr-in-Charge. Make : Indo Asian, Cat No : 830335 or its techno commercial equivalent.
Supply only MCCB 125 Amps 4 pole 25KA, adjustable thermal setting type and corfirming to IEC 60947-II complete all specified and directed by Engr-in-Charge. Make : Indo Asian, Cat No : 830273 or its techno commercial equivalent.
Supply only MCCB 100 Amps 4 pole 25KA adjustable thermal setting type and corfirming to IEC 60947-II complete all specified and directed by Engr-in-Charge. Make : Indo Asian, Cat No : 830272 or its techno commercial equivalent.
Supply only MCCB 63 Amps 4 pole 16KA adjustable thermal setting type and corfirming to IEC 60947-II complete all specified and directed by Engr-in-Charge. Make : Indo Asian, Cat No : 830240 or its techno commercial equivalent.
Supply only digital ammeter 500amps range suitable for mounting existing panel all as specified and directed
Supply only digital voltmeter 500 Volts range suitable for mounting existing panel all as specified and directed
M & L for Earthing complete with galvanised earth plate electrode of size 600x600x6 mm thick burried directly in ground earth pit not less than 2.25 m below ground level with top edge of earth plate not less than 1.5 mtrs below ground level connected to 4 mm dia GI earth wire as earth lead upto a length of 7.5 metre long by means of bolts,nuts, washers etc. and protected by GI pipe light grade 15mm dia and 20mm dia GI tubing light grade with funnel for watering, all as shown in electrical plate No 3 of SSR Part-I, back-fill with salt and charcoal, provision of test point including connected to earth test point and necessary earth work excavation in any type of soil PCC (1:3:6) type C1 bed and chamber RCC (1:2:4) type B1, iron grill including GI cover with hinge and funnel watering pipe etc all as specified and directed by Engr-in-Charge.
Servicing, cleaning and repairing by dismantling and taking out air circuit breaker of capacity 400/630/800 amps, 3 pole 415 volts 50 Hz of make-ABB/CG/Merlin Gerin and removing mechanical assembly fixed and moving contact set and replacing unserviceable mechanical parts like spring, bushes, levers and checking for worn out contacts, overvoltage and under voltage settings and replacing the following electrical parts (i) fixed contact assembly (ii) moving contact assembly, (iii) pole assembly (iv) Arc chute . Reassembling, testing and commissioning completely all as directed by Engineer in charge Note:- Replacement of unserviceable electrical parts will be measured as supply only and paid separately under relevant items of this schedule.
Supply only contact assembly for 630/800 Amps 3 pole 415 volts ACB of exisiting make all as specified and as directed by Engineer in charge.
All as per item No 44 here-in-before but 400 Amps capacity
Supply only moving contact assembly for 630/800 amps 3 pole 415 volts ACB of exisiting make all as specified and as directed by Engineer in charge.
All as per item No 46 here-in-before but 400 Amps capacity.
Supply only pole assembly for 630/800 amps 3 pole 415 volts ACB of exisiting make all as specified and as directed by Engineer -in- charge.
All as per item No 48 here-in-before but 400 Amps capacity.
Supply only Arc chute for 630/800 amps 3 pole 415 volts ACB of exisiting make all as specified and as directed by Engineer- in- charge.
All as per item No50 here-in-before but 400 Amps capacity.
Supply only spring charging motor for 630/800 amps 3 pole 415 volts ACB of exisiting make all as specified and as directed by Engineer- in- charge.
All as per item No 52 here-in-before but 400 Amps capacity.
Supply only control relay for spring charging motor for 630/800 amps 3 pole 415 volts ACB of exisiting make all as specified and as directed by Engineer- in- charge.
All as per item No 54 here-in-before but 400 Amps capacity.
Supply and fix in repairs aluminium lugs suitable for UG cable of size 6 Sqmm to 25 Sqmm all as specified and as directed.
All as per item No 56 but of size 35 Sqmm to 50 Sqmm.
All as per item No 56 but of size 70 to 95 Sqmm.
All as per item No 56 but of size 120 to 185 Sqmm.
All as per item No 56 but of size 240 to 300 Sqmm.
Preparing old faded surface of existing LT panel/feeder pillar located at various places by rubbing and removing the old paint complete and painting with two coats of super enamel paint over a coat of red oxide primer including writing of incoming and outgoing feeder details as required size of letters all as specified and directed.
M&L for repairing and testing of Servo Controlled Stabilizer capacity 10/20 KVA at reputed workshop including disconnecting the LT cables complete and taking out the core and checking the continuity and insulation value of coils for all three phases, inspecting and reinsulating coils if required, repair and, replacing the wornout parts if any, all as specified and as direcrted. Note : The rate shall also deemed to be included the rate for : (i) Technician, Electrician,and labours. (ii) Rewing of coils (iii) Minor spares/parts. (iv) Transportaion charges upto workshop and back.
Cleaning of substations located at technical area once in a month as per Engr-in-charge's instructions by applying cloth for removing dirt on all the equipments located inside the sub stations and removing all the grass weeds/vegetation with roots or by applying spray of Herbicides. Note:-(i) Total 12 Nos E/M Sub Station/Installation cleaning will be carried out once in a month and the same will be measured as one job. (ii) The rate for labour/herbicides to be included in the quoted rate. (iii) The quoted rate shall also include the rate of materials like cottton, Broom, MAFF, Stick for mounting Broom, Phenol which are required for the cleaning of installations.
Supply and fix in repair Display board for Pro-33 (Part No YVDH0002) of 30 KW Solar String Inverters complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair Logic Board (Part No VPBV1830E0) of 20 KW Solar String Inverters complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair AC filter board (Part No VKA.V1811.7) of 20 KW Solar String Inverters complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair PCBA Communication board (Part No VTAV06L09.3) of 20 KW Solar String Inverters complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair PCBA DC filter board (Part No 1908.0SI) of 20 KW Solar String Inverters complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair Dehn DG M TT 275 FM (Part No 3AYNAC275N-SPD) of 20 KW Solar String Inverters complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair AC Filter board (Part NoYVD.H0027.0) of 30 KW Solar String Inverters complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair Fuse control board (Part No VTA.V0R.7.SI) of 20 KW Solar String Inverters complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair IGBT Board (Part No YVP.H0004.0) of 30 KW Solar String Inverters complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair Negative/Positive Fuse board (Part No VKA.V2Y36) of 50 KW Solar String Inverters complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair Power module external fan (Part No VUD.V1U04) of 50 KW Solar String Inverters complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair Switch disconnector OT100F4N2 (Part No ZEC.00132) of 50 KW Solar String Inverters complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair Power module internal fan (Part No ZFV.V1U02.0) of 50 KW Solar String Inverters complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair PCBA Input fuse board negative side (Part No YVD.V2Y5W.0) of 50 KW Solar String Inverters complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair DC Switch 4 pole (Part No ZEC.00196) of 50 KW Solar String Inverters complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair Fuse holder (Part No ZEG.00023.0) of 50 KW Solar String Inverters complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair IGBT Board (Part No YVP.V1U55.1) of 50 KW Solar String Inverters complete all as specified and as directed by Engr-in-Charge.
Supply and fix in repair AC DB 20 KW, 3 phase SPD, ABS enclosure size 280mm x 280mm x 130mm including 40 Amps AC MCB, inverter input gland PG21, Grid input gland PG21, testing and commissioning complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair AC DB 30 KW, 3 phase, SPD, ABS enclosure size 380mm x 280mm x 130mm including 63 Amps AC MCB, inverter input gland PG21, Grid input gland PG21, testing and commissioning complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair AC DB 50 KW, 3 phase SPD, ABS enclosure size 560mm x 380mm x 180mm including 100 Amps AC MCCB, inverter input gland PG29, Grid input gland DC-38mm, testing and commissioning complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair DC DB 20 KW, ABS enclosure size 380mm x 280mm x 130mm including, input-04 Nos, output-04 Nos, 2 Nos of MPPT in inverter, DC Fuse holder 30A -04 Nos, DC Fuse 15A -04 Nos, DC SPD 1000V - 02 Nos, DC MCB 800V DP-04, Cable gland PG7-16 Nos, Cable Grand PG13.5-01 Nos, testing and commissioning complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair DC DB 30 KW, ABS enclosure size 560mm x 380mm x 180mm including, input-06 Nos, output-06 Nos, 3 Nos of MPPT in inverter, DC Fuse holder 30A -12 Nos, DC Fuse 15A -12 Nos, DC SPD 1000V - 02 Nos, DC MCB 1000V FP-04, Cable gland PG7-24 Nos, Cable Grand PG13.5-01 Nos, testing and commissioning complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair DC DB 50 KW, ABS enclosure size 560mm x 380mm x 180mm including, input-12 Nos, output-12 Nos, 4 Nos of MPPT in inverter, DC Fuse holder 30A -24 Nos, DC Fuse 24A -12 Nos, DC SPD 1000V - 04 Nos, DC MCB 1000V FP-04, Cable gland PG7-48 Nos, Cable Grand PG13.5-02 Nos, testing and commissioning complete all as specified and directed by Engr-in-Charge.
Supply and fix in repair MC-4 connector with male and female pin complete all as specified and directed by Engr-in-Charge.
Supply and fix surge protection device (DC) 1000 Volt, 3 phase, 4 pole complete all as specified and directed by Engr-in-Charge.
Repairs to Solar string inverter of capacity 20 KW in situ/authorised workshop of M/s ABB complete all as specified and directed by Engr-in-Charge. Note : Spares/parts will be measured and paid separately under relevant items.
All same as per item No 89 above but capacity 30 KW.
All same as per item No 89 above but capacity 50 KW.
Supply and fix in repairs MCB DC Single Pole (SP), 6 to 32 Amps rating, Curve, 10 KA rupturing capacity compete all as specified and directed by Engr-in-Charge.
All same as per item No 92 above but Single pole and Neutral, rating 6 to 32 Amps.
All same as per item No 92 above but Four Pole, rating 63 Amps.
Maintenance of Solar Control System of 1 MW Solar Power Plant, including recharging of postpaid sim cards (21 Nos) complete all as specified and directed by Engr-in-charge.
M/S Sneha Enterprises
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .