Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.0 LAccepted-AOC | L1 | Accepted-AOC Found lowest and reasonable | |
| 2 | L2₹16.0 L+₹45,145 (2.90%)Rejected-Finance | L2 | Rejected-Finance In order but L2 | |
| 3 | L3₹16.1 L+₹57,835 (3.72%)Rejected-Finance 4029 KALI MAI ROAD NASIRABAD AJMER RAJASTHAN 305601 | AJMER | RAJASTHAN | 305601 | L3 | Rejected-Finance In order but L3 | |
| 4 | L4₹16.5 L+₹99,550 (6.40%)Rejected-Finance 7 2 S F ARIHANT ARCADE CENTRAL MARKET SHASTRI NAGAR MEERUT U P 250004 | MEERUT | MEERUT | UTTAR PRADESH | 250004 | L4 | Rejected-Finance In order but L4 | |
| 5 | L5₹16.9 L+₹1.3 L (8.54%)Rejected-Finance | L5 | Rejected-Finance In order but L5 |
Tender Value
Refer Docs
EMD Value
₹50,000
Closing Date
28 Jul 2023, 6:00 pmClosed
GE (U) E/M Meerut
Roorkee road Meerut cantt
REPAIR TO PLASTERING, FLOORING, JOINERY, SANITARY FITTINGS, TILING AND PERIODICAL SERVICES OF W/S INSTALLATIONS UNDER AGE B/R AT GE (U) E/M MEERUT CANTT
2023_MES_607275_1
8546/E8
Open Tender
Civil Works
Item Rate
180 days
Meerut
Please refer Tender documents.
11 documents required · 11 mandatory
₹500
GE(U) E/M Meerut
₹50,000
Yes
8 Sept 2023
30 Jun 2023
31 Jul 2023
30 Jun 2023
28 Jul 2023
14 Jul 2023
Amount
Demolition of brick work or stone /boulder masonry, built in cement mortar, including all quoins, arches, pillars etc but excluding ashlar facing, dressed stone work and precast concrete articles etc, complete all as specified and directed by Engr-in-charge.
Demolition of cement concrete (unreinforced) in ground floor and in pavings not exceeding 15 cm thickness (below or above ground level), complete all as specified and directed by Engr-in-charge.
Plain cement concrete, (Nominal mix), type B-1, 1:2:4 (using 20mm graded crushed stone aggregates) as in cills, coping, apex stone, bed plates and lintel upto 1.6m clear span etc including weathering slightly rounded or chamfered angles and throating as directed including necessary form work, complete all as specified and directed by Engr-in-charge.
Brick work with flyash bricks straight or curved on plan, exceeding 6 m mean radius with old size bricks, built in cement mortar 1:6, complete all as specified and directed by Engr-in-charge.
All as per item No 04 here-in-before but except bricks, complete all as specified and directed by Engr-in-charge. Note : Old bricks obtained against demolition shall be used.
S&F 2nd class hard wood (sal/hollock), glazed and skelton shutters 35mm thick open rebated and prepared to receive glass, gauge,etc. (without sash bars), edges of framing palin, chamfered or rounded, fitted with cut & mitred beads for securing glass etc. sizes of members of shutters as specified in SSR Pt-I Section 8.24(a) supplied and fitted to chowkhats complete including fixing only iron mongery such as tower bolt,handle,hinges,aldrop bolt etc complete all as specified and directed
S&F factory made, 2nd class hard wood (sal/hollock), plain framed, panelled shutters (two panels) with lock rail and panel of 9 mm BWP commercial ply or 12 mm veneered particle board with commercial veneering on both sides, the side of rail and stile as per IS-1003 (Part-I), kiln seasoned and chemically pressure treated, 35 mm thick complete including fixing only iron mongery such as tower bolt,handle,hinges,aldrop boltcomplete all as specified and directed .
Taking down chowkats or frames including shutters (without taking off shutters from the frames) not exceeding 1.50 Sqm each, and removing from site, complete all as specified and directed by Engr-in-charge.
Taking down chowkats or frames including shutters (without taking off shutters from the frames) exceeding 1.50 Sqm but not exceeding 4 Sqm each, and removing from site, complete all as specified and directed by Engr-in-charge.
Taking down shutters of any description exceeding 1.00 Sqm and not exceeding 2.00 Sqm each, and removing from site, complete all as specified and directed by Engr-in-charge.
Taking down and refixing shutters of any description exc 1.00 Sqm and n.exc 2.00 Sqm each in same opening, complete all as specified and directed by Engr-in-charge.
S&F factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tube for top & bottom rails. M.S. frame shall be covered with heat mouleded plain colour PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side & as gap insert for top rail & bottom rail. Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, fixed in the frame at site as per specification clause No.8B.1 to 8B.10 and drawing on page No. 146 of MES SSR-2004 Part-II complete including fixing only iron mongery such as tower bolt,handle,hinges,aldrop bolt etc complete all as specified and directed .
Solid PVC door frame of size 50mmx47mm made out of 5mm plain colour PVC sheet reinforced with MS square tube, supply & fixing in opening as per specification & drawing shown in SSR Part-II, complete all as specified and directed by Engr-in-charge.
S&F aluminum handles cast type, anodised, 150mm size complete all as specified and directed .
S&F100mm long Butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised and fixed, and directed by Engr-in-charge.
S&F of 200 mm long mild steel barrel tower bolts, stove enameled black, with bright bolt complete all as specified and directed
S&F of mild steel sliding door bolt plate type 250 mm long stove enameled black with bright bolt not less 12 mm dia bolt with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, complete all as specified and directed .
S&F of mild steel sliding door bolt plate type 300 mm long stove enameled black with bright bolt not less 12 mm dia bolt with and including a minimum of 6 bolts and nuts, four on bolt plate and two on staple plate, complete all as specified .
S&F aluminum anodised barrel tower bolts of extruded section with 150 mm long bolt complete all as specified and directed .
M&L for providing cement concrete 1:3:6 type C-0 using 12.5mm graded crushed stone aggregates for filling in the pressed steel door frame/hold fast complete all as specified and directed .
S&F of stainless steel wire clothcut to size, 0.36 mm nominal dia wire and average width of aperture 1.40 mm and fixed with tinned tacks or galvanised wire staple complete all as specified and directed .
S&F in repair stainless steel wire cloth, 0.36 mm nominal dia of wire and average width of aperature 1.40 mm and fixed with stainless steel staple complete all as specified and directed by Engr-in-Charge.
Mild steel framed work such as grills, gratings with ends of bars shouldered or reveted or forged into spikes, framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar works, conforming to Fe-290, Gde E-165, complete all as specified and directed by Engr-in-Charge.
Rolled mild steel plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, with riveted, bolted or welded attachment conforming to grade Fe.290.Gde-E-165, steel work duly painted with one shop coat of zinc chromate primer including preparation of surfaces complete all as specified and directed
S & F box type steel window double leaf double shutter (gauge shutter will open inside and glaze shutter will open outside) with side hung shutter including box type hinges with peg stay 300mm long and 100 mm long handles of Z Section welded to frames & 150 mm long tower bolt welded to shutter one each at top and bottom to each shutter complete with glazing bar for one shutter and gauze bars of FI 10x 3mm thick dovetailed or welded including 12 mm sqm guard bars 150 mm centre to centre complete all as specified and directed (Note:-Glass and wire gauze shall be measured and paid seperately)..
S&F factory made mild steel ventilators box type with upper top hung shutter and bottom fixed type shutters including pintol hinges and ,steel peg stay and one shop coat of red oxide primer complete all as specified and directed.
Pressed steel frames of size 105x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and providing one shop coat of primer and tarring back side of frame, complete all as specified and directed by Engr-in-charge.
Pressed steel frames of size 125x60mm for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc and providing one shop coat of primer and taring back side of frame, complete all as specified and directed by Engr-in-charge.
Dismantling Asbestos cement (corrugated,semi corrugated, etc) sheets in roof coverings complete all as specified and directed by Engr-in-Charge..
M & L for 6mm thick asbestos cement corrugated or semi corrugated sheets in roofs, walls etc fixed with L-type or J-type of cranked hook bolts complete all as specified and directed by Engr-in-Charge.
Except sheet 6mm thick asbestos cement corrugated or semi corrugated sheets in roofs, walls etc fixed with L-type or J-type of cranked hook bolts complete all as specified and directed by Engr-in-Charge.
M & L for Asbestos cement one piece plain angular ridge 6mm thick fixed with L-type or J-type or cranked hook bolts complete all as specified and directed.
Dismantling Plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof covering complete all as specified and directed by Engr-in-Charge.
M&L prepainted galvalume aluminium zink coating GI based corrugated steel sheet 0.50mm thick AZ 150 of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
M&L prepainted galvalume aluminium zink coating GI based plain steel sheet 0.50mm thick AZ 150 of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed by Engr-in-Charge.
M&L for Bitumastic gola, with 80/25 bitumen and coarse sand mixture 1:3 by weight, 8cmx8cm at the junction of roofing to vertical surfaces complete all as specified and directed by Engr-in-Charge.
Dismantling floor , hearth or wall tiling including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge.
M & L designer Glazed double charged ceramic (glossy finish) coloured tiles 300mm x 600mm x 7 mm thick as in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry, pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 to receive tiles, complete all as specified and directed by Engr-in-charge.
M & L Glazed ceramic coloured tiles 300mm x 200mm x 7/450X250x7 mm thick as in vertical surfaces such as skirting dado etc set and jointed in neat cement slurry, pointed in white or coloured cement to match over and including 10mm thick rendering in cement mortar 1:4 to receive tiles, complete all as specified and directed by Engr-in-charge.
M&L Non skid coloured 7 to 8 mm thick area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm, in floor etc set and jointed in neat cement slurry and pointed in white or coloured cement to match, laid over 15mm thick screed bed in CM 1:6, complete all as specified and directed by Engr-in-Charge.complete all as specified and directed by Engr-in-Charge.
M & L for 100mm thick PCC type D-2 1:4:8, using 40mm graded crushed stone aggregate as in flooring finished even and smooth without using extra cement with spike rolling to surfaces or making impression of expanded metal, whilst the concrete is green all as directed by Engr-in-Charge.
M & L for Plain cement concrete, (Nominal Mix), type C-2, 1:3:6 (using 40 mm graded crushed stone aggregates) as in surface channel and drain, complete all as specified and directed by Engr-in-charge.
Taking down cement plaster, any description on brick or stone or cement concrete walls including raking out joints, hacking for key, scrubbing down with water complete all as specified and directed
M&L for 15 mm thick rendering on fair faces of brick or stone/concrete surfaces in cement mortar 1:4 and finished surface even and smooth without using extra cement complete with water proofing compound complete all as specified and directed . (WPC shall be measured separtely)
M&L for 10 mm thick rendering on fair faces of brick /concrete surfaces in cement mortar 1:6 and finished even and smooth without using extra cement complete all as specified and directed .
M&L for 5 mm thick rendering on fair faces of brick /concrete surfaces as in ceiling in cement mortar 1:3 and finished even and smooth without using extra cement complete all as specified and directed .
M&L for applying two coat of oil bond distemper on walls after preparation of newly plastered surfaces over a coat of white primer, complete all as specified and directed
M&L for applying three coats of white washing on ceiling including preparation of newly plastered surfaces complete all as specified and directed .
M&L for applying two coats of external wheater proof emulsion paint on walls after preparation of newly plastered surfaces over 1 mm thick wall care putty etc, complete all as specified and directed .
Preparation of new wooden surfaces of any description not otherwise described, exc 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of pink primer, complete all as specified and directed by Engr-in-charge.
Preparation of new steel surfaces of any description not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, complete all as specified and directed by Engr-in-charge.
M&L precast cement concrete jallies 25mm thick (measured solid set in cement mortar 1:4 incl all moulding and necessry form work, complete all as specified and directed by Engr-in-charge.
M&L for machine pressed precast cement concrete interlocking paver block 50% grey and 50% coloured any shape and size conforming to IS 15658-2006 of 60mm thick, M-35 over and incl 75mm thick PCC type D2 (1:4:8) and 25mm thick sand cushioning, complete all as specified and directed by Engr-in-charge.
Taking down steel rolling shutters manually operated type with ball bearing cover hood and channel, anchoring rod etc of size upto 25 sqm each complete all as specified and directed by Engr-in-Charge.
M&L for Steel rolling shutters 1.25mm thick without ball bearing, as specified including top cover, anchoring rod, hasp & staple & one shop coat of primer; erected in position as indicated, complete push pull or manual type complete all as specified and directed.
S&F safety lever locks mild steel with 4 levers for rolling shutters complete all as specified and directed by Engr-in-Charge.
S&F Ball bearing for rolling shutters as per existing complete all as specified and directed by Engr-in-Charge.
Repairs to existing steel rolling shutters without ball bearing by taking down top cover, anchoring rod, spring etc and providing new springs and anchoring rod, replacing the worn out strips, safety lever lock of shutters and welding of handle, hasp staple and other broken articles etc, greasing the spring, guide rail, shaft etc and making functional and errecting in position, including refixing of top cover/hood etc, and refixing in same opening and making good in CM 1:3/PCC to match the existing surface, opening n.exc. 10 sqm each and finally painting with two coats of synthetic enamel paint, complete all as specified and directed by Engr-in-Charge.
M&L Roughening surfaces of old concrete surfaces by picking sweeping, cleaning and washing down with water to remove dust etc including taking down tarfelt and brushing neat cement slurry @ 3 Kg/Sqm including 20mm thick screeding in CM (1:3) finished even and smooth mixed with water proofing compound (WPC shall be measured and paid separately)
M&L Applying bituminous primer on roof surfaces @ 0.40 ltr/Sqm and applying one coat of hot blown bitumen of grade 85/25 @ 1.20 Kg/Sqm and laying 3mm thick polymeric waterproofing membrane of 3.5 Kg/Sqm and bonded completely to the surfaces with overlap of 10 cms( with torch application) and overlaps are to be sealed by flame torch and applying one coat of IWL Aluminium paint all as specified and directed.
M&L for prepration of old wooden surfaces of any description not otherwise described over 10 cm width or grith and applying one coat of synthetic enamel paint complete all as specified. (Note:-Using roller for painting and use scrapping machine for scrapping work)
M&L for prepration of old steel/iron surfaces of any description not otherwise described over 10 cm width or grith and applying one coat of synthetic enamel paint complete all as specified.
Preparation of old plastered/unplastered wall surfaces and applying one coat of cement base paint (including wahsing, rubbing down and stopping of distempered and painted surfaces), complete all as specifed.
Preparation of old plastered/unplastered wall surfaces and applying one coat of oil bound distemper over 1 mm thick wall care putty (including wahsing, rubbing down and stopping of distempered and painted surfaces), complete all as specifed.
Hacking out old broken glasses (any thickness, size, quality or description) from wooden frames or steel frames, glazed with putty or fixed with wooden beads, complete all as specified and directed by Engr-in-charge.
3mm thick sheet glass ordinary quality, and glazing with oil putty or wooden beads in squares n.exc 0.50 Sqm in each pane, complete all as specified and directed by Engr-in-charge.
Demolition of stone slabs & tiles including cement mortar beddig(but not backing) of any description or thickness in floors, aprons, etc, laid, bedded and pointed in any mortar complete all as specified and as directed by Engr-in-Charge.
M & L for Machine cut kota stone slab flooring 20-25mm thick over 15mm thick screed bed in CM (1:4) laid & jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing, granite cutting and mirror polish finish complete all as specified and as directed by Engr-in-Charge.
M & L for kota stone slab flooring 20-25mm thick in riser of steps, skirting, dado & pillar over 10mm thick plaster in CM (1:6) jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing, polishing, granite cutting and mirror polish finish complete all as specified and as directed by Engr-in-Charge.
M&L for preparation old plaster surfaces applying Two or more coats of 100% Premium external weatherproof paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungaedl resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over 1mm thick wall care putty. complete all as specified and directed. Make:-Apex Ultima protect/Berger paints(weather coat smooth)).
M/s D.K.Enterprises
M/S KAPIL ENTERPRISES
AEGIS INTERNATIONAL
BHAGWAN DAS & Co
M/S ABHI ASSOCIATES
mohanlal gupta
M/S AGARWAL CONSTRUCTION CO.
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .