Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Rejected-Technical | Rejected-Technical Rejected |
| 4 | Rejected-Technical | Rejected-Technical Rejected |
| 5 | Rejected-Technical | Rejected-Technical Rejected |
Tender Value
₹71.0 L
EMD Value
₹1.4 L
Closing Date
10 Mar 2023, 3:00 pmClosed
Nodal Officer
e Procurement Cell, Office of the Superintending Engineer, Building Construction Department, Circle No.-2, Combined Building, Line Tank Road, Ranchi-834001
Construction of Block Public Health Unit in The Campus of Public Health Centre in Lesliganj ,Under Palamu District
2023_BCD_67400_1
13/BCD/CIR-2/DALTONGANJ
Open Tender
Civil Works - Buildings
Works
270 days
Palamu
Please refer Tender documents.
2 documents required · 2 mandatory
₹10,000
EE, BCD, Building Division, Daltonganj
₹1.4 L
Yes
4 May 2023
4 Mar 2023
11 Mar 2023
4 Mar 2023
10 Mar 2023
4 Mar 2023
Amount
Earthwork in excavation in foundation trenches in ordinary soil (vide classification of soil item - A0 and disposal of excavated earth as obtained to a distance upto 50M including all lifts levelling, ramming the foundation trenches, removing roots of trees, shurbs all complete as per approved design, building specification and direction of E/I.
Filling in foundation trenches and plinth in layers not exceeding 150mm thick well watered, rammed, fully compacted and fine dressed with earth obtained from excavation of foundation trenches within a lead of 50M and lift of 1.5M all complete as per building specification and direction of E/I. (Mode of measurement compacted volume)
Providing coarse clean Sand in Filling in foundation trenches or in plinth including ramming and watering in layers not exceeding 150mm thick with all leads and lifts including cost of all materials, labour, royalty and taxes all complete as per building specification and direction of E/I. (Mode of measurement compacted volume).
Providing designation 75B one brick flat soling joints fitted with local sand including cost of watering taxes royalty all complete as per building specification and direction of E/I.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:4:8 (1 Cement : 4 coarse sand (zone-III) : 8 graded stone aggregate 40 mm nominal size)
Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :
1:1.5:3 (1 cement : 1.5 coarse sand (zone-III): 3 graded stone aggregate 20 mm nominal size)
Providing designation 100 A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9"x4.5"x3") in C.M. (1:6) in foundation and plinth with approved uality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : Column
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size).
Providing Toe steel reinforcement of 8mm dia rods as approved
Providing Toe steel reinforcement of 10 mm dia rods as approved
Providing Toe steel reinforcement of 12 & 32 mm dia rods as approved
Centering and shuttering including strutting, propping etc. and removal of form for :
Foundations, footings, bases of columns, etc. for mass concrete
Columns, Pillars, Piers, Abutments, Posts and Struts
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Suspended floors, roofs, landings, balconies and access platform
Providing and fixing circular/ Hexagonal cast iron or M.S. sheet box for ceiling fan clamp, of internal dia 140 mm, 73 mm height, top lid of 1.5 mm thick M.S. sheet with its top surface hacked for proper bonding, top lid shall be screwed into the cast iron/ M.S. sheet box by means of 3.3 mm dia round headed screws, one lock at the corners. Clamp shall be made of 12 mm dia M.S. bar bent to shape as per standard drawing.
Providing designation 75B brick work in C.M. (1:6) in foundation and plinth approved quality of clean coarse sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes an
Providing designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9" x 4.5" x 3") in C.M. (1:6) in superstructure with approved quality of clean sand of F.M. 2 to 2.5 including providing 10mm thick mortar joints, cost of screening materials, raking out joints to 15mm depth, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing designation 112mm thick reinforced designation 100A brick work with fly ash lime brick (FLAG) confirming to IS 12894-1990 (9" x 4.5" x 3") in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carraige of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforced) all complete as per building specification direction of E/I.
Providing 6mm thick cement plaster (1:4) in ceiling with clean of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm thick cement plaster (1:6) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing two coats of oil bound distemper of approved shade and make over a coat of cement primer over new surface including preparing the plastered surface by the rubbing smooth with pumice stone or fine sand paper applying putty wherever required scaffolding washing of floors and taxes all complete as per building specification and direction of E/I.
Providing two coats of snowcem of approved shade and make new old surface including washing cleaning, and preparing the walls, scaffolding, curing and taxes all complete as per building specification and direction of E/I.
Providing 25mm thick first class patent stone flooring (1:2:4) with stone chips in two layers, bottom layers 19mm. Thick (1:2:4)with 12mm to 6mm. Size graded stone chips and top layer 6mm. Thicks (1:2) with 6mm down stone chips, in panels including cost of curing, finishing the surface smooth by rubbing with carborandum stone, taxes and royality with all complete as per building specification and direction of E/I.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Glazed Vitrified tiles Matt/Antiskid finish of size
Size of Tile 600 x 600 mm
Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand).
Medium shade pigment using 50% white cement 50% Grey cement
Providing and fixing stone slab with table rubbed, edges rounded and polished, of size 75x50 cm deep and 1.8 cm thick, fixed in urinal partitions by cutting a chase of appropriate width with chase cutter and embedding the stone in the chase with epoxy grout or with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 6 mm nominal size) as per direction of Engineer-in-charge and finished smooth.
Granite Stone of approved shade
Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite of any colour and shade Area of slab over 0.50 sqm
Extra for pre finished nosing to treads of steps of marble stone.
Providing and fixing pressed steel door frames conforming to IS: 4351,manufactured from commercial mild steel sheet of 1.60 mm thickness,including hinges, jamb, lock jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or base ties of 1.60 mm,pressed mild steel welded or rigidly fixed together by mechanical means,lock strike-plate and shock absorbers as specified and applying a coat of approved steel primer after pre-treatment of the surface as directed by Engineer-in-charge:
Supplying, fitting & fixing 35mm thick solid core type non-decorative single leaf flush shutters in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneeres of standard makew with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
Supplying, fitting & fixing 35mm thick solid core type non-decorative double leaf flush shutter in doors and windows with black board core blended with high quality phenol formal dehyde synthetic resin both side commercial veneeres of standard makew with oxidised iron fittings such as hinges, tower bolts, handle, cleats and sand blocks and taxes all complete as per building specification and direction of E/I.
Providing & Fixing decorative high pressure laminated sheet of plain / wood grain in gloss / matt/ suede finish with high density protective surface layer and reverse side of adhesive bonding quality conforming to IS : 2046 Type S, including cost of adhesive of approved quality.
Providing and fixing PVC rigid foam sheet 1 mm thick on existing door shutters (bathroom and W.C. doors) using synthetic rubber based adhesive.
Providing and fixing M.S. grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.
Fixed to openings /wooden frames with rawl plugs screws etc
Providing two coats of synthetic enamel paint of approved shade and make over steel surface including cleaning the surface thoroughly cost of scaffolding and taxes all complete as per building specification and direction of E/I.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) : For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately) Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item): With float glass panes of 5.0 mm thickness (weight not less than 10 kg/ sqm)
Galvanised wire mesh of average width of aperture 1.4 mm and nominal dia of wire 0.63 mm
Water proofing for Old and New Roof Slab Providing and laying water proofing treatment on roof slab by applying two Component, factory designed, ready to use, acrylic modified flexible material applied wth brush, roller or spray for water proofing coating as Per ....Mier specificatIons with following steps (a)surface preparation -Providing and cleaning o1 concrete ...lece le remove dust, oil, grease including removal of existing loose paint r coating, and cement laitance by cleaning with comer..ed air 8 water let including all materials, labour, tools complete Ponding test to be done after plugging all outlets and to be checkedtrodentify seepage eakage On identification of seeps cem t be done with non shrink expanding admixt e a Ind, t 1MYK c g / Dr Fout/Fosroc or equive teems such as those betwe be chamfered with 15 1 41 admixed with ac Fixit or equivalent slum, of acrylic concretein base rovtartg and repaving of all c arapet wall and the roof slab et 50 mm fillet of mortar (Cement sand mer of Sika/ Fosroc/MYK SchomberglDr chamfering a prime coat shall be given with the Repairing surface irregularities, damaged ad cracks if any, with an acrylic polymer modified repair moile, including a coat of bonding agent of the same with cement slurry inctC01; all material, labour, tools complete (b)1st Coat - APOrlit coat of two component acrylic modified, ready to use. flexible come s material on surface saturated dry roof and inside wall of Par ll upto 600 mm by brush or roller After 1st coat re. pgplaisesd c@lot,h5t: kla9y,sw,nheincothaet rost, itahyee r of application , 45 still green 1st coat purpose of measure he entire treated surface will be measured "4, (c) 2nd Coat -To apply g02 coat of two component acrylic rnorAdmir* ready to use, flexible come' tonal right angle to the 140,af,•:,-- over the glass fibre laid surface*d alepld be * applied VW Sgmt/coat For the purpose of rnikeSCiretfleritthe entireteaterfstiface will be measured " After three days of drying the 2nd coat , the rain water outlets to be plugged and ponding test to be done for 48 hours to identify seepage, leakage from soffit and found necessary rectification to be done as per satisfaction of E/C The waterproof coating to be protected from damage before screed over it Water proofing Brand - Sika Topseal 109hi / Fosroc Brushbond RI". Dr Feet Picliflin 2K 1 MYK Actuate' TG Product Performance Chemical Base F'. A Acrylic copolymer, Part B: Specially graded cementitious powder -D011,4 1.6 fief, (mixed density) at 427°C Tensile Strength -2 N/mm2 atter 28 days (with Fibre cloth) (According to ASTM D 2370) Pullout Bond Strength -2 N/mm2 (concrete failure) (According to ISO 4624) Slant-Shear Bond Strength -4 N/mm2 (According to FIP 5 15) Elongation at Break -35% without Fibre Cloth and 20% with Fibre Cloth (According to ASTM D 2370) (d) Protection of treated surface with PCC •- The treated surface should be covered with 25mm/50mm PCC of M-20 grade(1.1.5 3) with proper slope ( 1 120) towards the rain outlets in alternatepanels of 2 mt x 2mt keeping 6 mm gap between the panel joint Integral water proofing admixture conforming to IS 2645 @ of 100 ml per bag of of cement to be added in the screed concrete (paid separately for this items) All corners shall be chamfered with 150mm X 150 mm fillet The rainwater outlets shall be just leveled with the screed concre toe ure smooth discharge of water - the peripheral gaps be en p pi o and concrete surface should be packed pro with n c e and tiurpheral mouth to be sealed with ure Pvt Ltd. / MYK Schomb Fixit/Fosroc For the purpose of measurement the ed surface will be measured " ensitive epoxy putty o (e)Groove of PC should be filled with Polysulphide Sealant. (Paid Separate* d - Sika India Pvt Ltd / MYK Schomberg / Dr FixitiFosroc W for five years
Covering of treated surface with PCC .- Providing 25 mm thick Cement Alf, Concrete M20 1:1. :3) maintaining slope in alternate 2 mt x 2 mt panels with aaprove. of stone chips of 20 mm to 6 mm size graded and cleaned sand 2.5 to 3 including screening,shuttering,and mixing cement concret . fixer with admixture of integral water proofing and placing in posi . ing curing,taxes and royality all complete as per building specifi nd direction of Ell. Panels that has been left shoul be casted next dysThere should be 6 mm gap between Panels .Brand Sika _Plastocrate Aus,MYK proof WP10, Fosroc- Conplast X421 lc& Dr Fixit Pidiproof LW+
Providing and filling of 6 mm thick Groove between 25 mm PCC Panels with Polysulphide Sealant (Poring Grade)as Per drawings and technical specifications and direction of E in Charge (with 18% GST Polysulphicle Fosroc-Thoflex 600.Dr Fixit Pidiseal PS(42P) !MraYndK -Seikaal PS or Euivalent
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes. 110 mm diameter
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
Bend 87.5° 110 mm bend
Shoe (Plain) 110 mm Shoe
Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. 110 mm
Providing 250mm wide brick drain in cement mortar (1:6) with av. 150mm clear depth and 125mm apron including cost of earthwork involved with 75mm cement concrete (1:4:3) over one brick designation 75A flat soling in proper grade and slope at the base the drain duly plastered in C.M. (1:3) with punning over exposed surface all complete as per building specification and direction of E/I.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone - III) : 6 graded stone aggregate 20 mm nominal size) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Providing designation 125mm thick reinforced designation 75A brick work in C.M. (1:4) in superstructure with approved quality of clean coarse sand of F.M. 2 to 2.5 including the cost of screening, carriage of materials, scaffolding, raking out joints to 15mm depth, curing, taxes and royalty (but excluding the cost of reinforcement) all complete as per building specification and direction of E/I.
Providing 12mm cement plaster (1:3) with clean coarse sand of F.M. 1.5 including screening, curing with all leads and lifts of water, scaffolding taxes and royalty all complete as per building specification and direction of E/I.
Providing 12mm cement mortar (1:3) with clean coarse sand of F.M. 1.5 with floating coat of neat cement in skirting including rounding of junctions with floor, curing, taxes and royalty all complete as per building specification and direction of E/I.
Providing 1.5mm cement punning including curing, carraige of water with all leads and lifts as per building specification and direction of E/I.
Supplying and fixing C.I. cover without frame for manholes : 500 mm diameter C.I. cover (medium duty) the weight of the cover to be not less than 58 kg
Making soak pit 2.5 m diameter 3.0 metre deep with 45 x 45 cm dry brick honey comb shaft with bricks and S.W. drain pipe 100 mm diameter, 1.8 m long complete as per standard design. With common burnt clay F.P.S. (non modular) bricks of class designation 7.5
Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen (RMS) pipes with ribs, conforming to IS: 12818, including hire & labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer-in-charge. 100 mm nominal size dia
Supplying, filling, spreading & leveling stone boulders of size range 5 cm to 20 cm, in recharge pit, in the required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge.
Supplying, filling, spreading & leveling gravels of size range 5 mm to 10 mm, in the recharge pit, over the existing layer of boulders, in required thickness, for all leads & lifts, all complete as per direction of Engineer-in-charge
Carriage of material
Brick - 7 +1 km
Sand - 12 km
Chips - 22 Km
Metal - 22 Km
Flyash Brick - 15 Km
Supplying, fitting and fixing 40 mm high viterous white glazed earthen ware E.W.C. with "p" trap of Parry Hindustan or any other I.S.S. make including supplying & fixing 15 litres C.I. mosquito proof low down flushing cistern of approved make with complete fittings with C.I. handle and R.S. or bracket with telescopic flush pipe with brass coupling and plumbers joints spindle stop cock of approved quality weight not less than 450 grms. , 15 mm P.V.C. alkathene pipe 45 cm long with brass coupling at both ends and white/ black plastic solid state seal and lead of commander/ cuckoo or other I.S.S. make with hinges or screw etc. painting pipe and cistern etc. with 2 coats of approved paint over a coat of red oxide primer etc. all complete as per specification and direction of E/l. (A) With "P" trap (b)10 lit. low level P.V.C. cistern
Supplying, fitting and fixing flat back or angular, lipped front viterous white glazed earthen ware urinal of Hindustan 'Parry' or any other approved I.S.S. make with 5 litres capacity C.i. automatic flusing cistern of reliance for any other I.S.S. approved make with all fittings with C.I. or R.S. brackets, standard size G.I. flush pipe with fitting clamps, 15mm C.I. body brass spindle stop cock of approved quality weight not less than 400 grams, 15mm PVC/Alkthene pipe 450mm longwith brass coupling at both ends and doing plumber joints including priming coat of red oxide, cutting wall and floor making good the same etc. all complete as per specification and direction of E/I. Flat back or standard corner (600mm x 350mm)
Providing and fixing C.P. brass bib cock of approved conforming to IS 8931 : 15 mm nominal bore
Providing and fixing C.P.brass long body bib cock of approved quality conforming to standard and weight not less thain 690gms.:15 mm nominal bore.
Providing and fixing PTMT Soap Dish Holder having length of 138 mm breadth 102 mm, height of 75mm with concealed fitting arrangements, Weighing not less then 106 gms.
Providing and fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 15mm nominal bore, approved brand C.P. fittings.
Providing and fixing C.P. extentsion Nipples 15mm size with 12” BSP threads, 70mm length and 30 mm bredth and weight not less than 18gms
Providing and fixing Mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thick hard board backing.Circular shape 450 mm dia
Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern,including painting of fittings and brackets, cutting and making good the walls wherever require :Falt back wash basin size 630X450 mm with a single 15mm C. P. pillar tap.
Providing and fixing PTMT grating of approved quality and colour. 125 mm nominal dia with 25 mm waste hole
Providing and fixing unplasticised P.V.C. connection pipe with PTMT Nuts, collar and bush of approved quality and colour. 15 mm nominal bore with 45 cm length
Providing And fixing 32 mm waste pipe for sink or wash basin including P.V.C. waste fittings complete.
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes joining of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of E/I. (Approved Brand - ASTRAL/ SUPREME)
Concealed work including cutting chases and making good the wall etc..
15mm dia
20mm dia
Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. External work
25mm dia
32 mm dia.
40mm dia
Supllying and matarials with lobour for construction inspection chamber of designation class 75b brick deep 600x450 internal diamention having 250mm wall thickness in cement morter(1:6)including 12mm cement plaster (1:4)with punning on inside and cement plaster (1:6)with 600x450mm G.I. cover with frame (weight not less than 36k.g)in foundation and refilling all complete as per specification and direction of E/I.
Providing and fixing C.P. brass Stop Cock (concealed) of standard designand of approved make conforming to IS 8931 15mm nominal bore, approved brand C.P. fittings.
Polythene water storage tank of ISI mark (eg sintex /sinter/himgiri/gangotri ) with cover & locking system
Providing and fixing PTMT towel rail trapezoidal shape 215 mm long, 200 mm wide with minimum distances of 37 mm from wall face with concealed fittings arrangement of approved quality and colour, weighing not less than 88 gms.
Providing and fixing c.p. towel ring complite with brackets fixed to wooden cleats with c.p.brass screws with concealed fitting arangement of approved qualite colour and make.(Mark or equipment)
provding and laying of 110mm dia. P.V.C. pipe for outlet of water to outlet drain including all accessories ,I.e lubricants, solventcement, clamp, ring, sockets etc.(SUPREME S.W.R.)
provding and laying of 75 mm dia. P.V.C. pipe for outlet of water to outlet drain including all accessories ,I.e lubricants, solventcement, clamp, ring, sockets etc.(SUPREME S.W.R.)
Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion.
75 mm Coupler
110 mm Coupler
75 mm Single pushfit Coupler
110 mm Single pushfit Coupler
75 mm Single tee with door
110 mm Single tee with door
75 mm Single tee without door
110 mm Single tee without door
75 mm Bend 87.5°
110 mm Bend 87.5°
75 mm Shoe (Plain)
110 mm Shoe (Plain)
Cost of Driling 200 mmx165mmx125 mtr.deep bore well in all kind of Soil and rock in rural area for instalation of pump set with Hydrolic DTH Rig machine all complete including all materials, tools,driling rig,air compressureand equipmentsas well as fule, lubricantsand cost of transportation of rig machine annd other vehical up to Site.
(a) From 0.00 M to 50.00 M below G.L.
(b) From 51.0 M to 100.00 M
Supplying, assembling, lowering and fixing in vertical position in bore well, unplasticized PVC medium well casing (CM) pipe of required dia, conforming to IS: 12818, including required hire and labour charges, fittings & accessories etc. all complete, for all depths, as per direction of Engineer -in-charge. 200 mm nominal size dia
Development of tube well in accordance with IS : 2800 (part I) andIS: 11189, to establish maximum rate of usable water yield withoutsand content (beyond permissible limit), with required capacity aircompressor, running the compressor for required time till well isfully developed, measuring yield of well by "V" notch method or anyother approved method, measuring static level & draw down etc. bystep draw down method, collecting water samples & getting testedin approved laboratory, i/c disinfection of tubewell, all complete,including hire & labour charges of air compressor, tools & accessoriesetc., all as per requirement and direction of Engineer-in-charge
Providing and fixing suitable size threaded mild steel cap or spot welded plate to the top of bore well housing/ casing pipe, removable as per requirement, all complete for borewell of: 200 mm dia
Providing and fixing M.S. clamp of required dia to the top of casing/ housing pipe of tubewell as per IS: 2800 (part I), including necessary bolts & nuts of required size complete. 200 mm clamp
Supplying 100mm dis submersible pump sets confirming to 8034 and motor confirming to IS 9283 pump shall be suitable for various delivery head and discharge with stainless steel pump shaft and polypropylene/noryl impeller. Motor suitable for working on 415 + 10, 3HP, 50 Hz, AC supply with cable guard, thurst carbon/fiber bearing to withstand entire hydraulic thurst, water proof winding shall be provided. The pump set shall be suitable for diret coupling Pump shall have suitable outlet as per manufacturers design. Anti thurst stream lined non return valve shall be provided with pump, 3 meter submersible copper conductor cable in single/double run shall be provided with each pump. Submersible pump set 100mm dia (with Polypropylene/Noryl Impeller) up to 20 stages 2 HP
Supplying fitting and fixing 3 crore 4 sqmm Flat copper submersible cable FINOLEX / HEVELS make including all taxes ,royalty etc all complete job as per direction of E/I.
Supply fitting and fixing lowering 40 mm dia G.L. collumn pipe - do - do - all complete job as per direction of E/I.
Point Wiring in PVC Conduit, with Modular type Switch:- Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/recessed PVC conduit, with modular type switch, modular plate, suitable size of GI box etc as required.
Group C
Supplying and fixing batten/ angle holder including connection etc. as required.
9/10 Watt LED Bulb
12" (300mm) Exhaust fan
16" (1200mm) Wall fan
Installation of exhaust fan upto 450mm sweep in the existing opening, including making the hole to suit the size of he above fan making good the damage, connection, testing, commisionig etc as required.
S/F light plug point with modular type accessories :- Supplying and fixing suitable size G.I. box with modular plate and cover in front on surface or in recess including providing and fixing 3 pin, 5/6 amps modular socket outlet and 5/6 amps modular type switch connection, painting etc, as required.
S/F light plug point with modular type accessories :- Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
S/F Modular boxes, base & cover plate :- Supplying and fixing following size/ modules G.I. box along with modular base & cover plate for modular switches in recess etc as required.
1 or 2 module (78mm x 78mm x 45mm)
6 module (78mm x 205mm x 50mm)
12 module (78mm x 230mm x 60mm)
S/F Modular boxes, base & cover plate :- Supplying and fixing following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate as required.
Telephone socket outlet (same shall be used for data point)
Telephone wiring in existing conduit:-
Supplying and drawing following pair 0.5 sq.mm FR PVC insulated copper conductor unarmored telephone cable in existing surface/recessed steel/PVC conduit
S/F Modular type blanking plate :- Supplying and fixing modular blanking plate on the existing modular plate & switch box but excluding modular plate as required.
SUBMAIN WIRING COPPER IN PVC CONDUIT Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit.
4 X 16 sq. mm + 2 x 6 sq.mm Earth Wire
4 X 10 sq. mm + 2 x 6 sq.mm Earth Wire
CIRCUIT WIRING COPPER IN PVC CONDUIT FOR 5A & SWITCH BOARD:- Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor single core cable in surfacce/ recessed medium class PVC conduit.
2 X 4 sq. mm + 1 x 4 sq.mm Earth Wire (Sockets)
2 X 2.5 sq. mm + 1 x 2.5 sq.mm Earth Wire (Switch Boards)
Copper earth pipe electrode :- Earthing with G.I. earth pipe 4.5mtr. long 40mm dia including accessories and providing masonary enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal or coke and salt as required.
P/F 25mm x 5mm copper earth strip in surface/ recess :- Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc., as required.
S/L 25 mm x 5 mm G.I. earth strip in ground :-
Supplying and laying 25 mm X 5 mm G.I strip at 0.50 metre below ground as strip earth electrode, including soldering etc.
S/F T.P. MCB DB:- Supplying and fixing following way three pole & neutral ,sheet steel, MCB distribution board, 415 volts, onsurface /recess, complete with tinned copper bus bar, neutral bus-bar, earthbar ,dinbar, interconnections, powder painted including earthing etc. as required.
4 Way (4+12) Double Door, Horizontal type
6 Way (4+18) Double Door, Horizontal type
Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10kA 'C' curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connection, testing & commissioning etc. as required.
63A rating, TPN MCB, "C" curve 10 KA breaking capacity.
40A rating, TPN MCB, "C" curve 10 KA breaking capacity.
25A rating, SPN MCB, "C" curve 10 KA breaking capacity.
16A rating, SPN MCB, "C" curve 10 KA breaking capacity.
10A rating, SPN MCB, "C" curve 10 KA breaking capacity.
Supplying and fixing following rating four pole, (three phase and neutral) 415 volts, residual circuit breaker (RCCB) having a sensitivity current 30 milli amperes in the existing MCB DB complete with connection, testing & commissioning etc. as required.
S/F Modular type electronic fan regulator :- Supplying and fixing stepped type fan regulator on the existing modular plate switch box including connections but excluding modular plate etc as required.
Supply, fitting, fixing and testing of 1200mm Sweep, double ball-bearing, 2 canopy ceiling fan including connection with 1.5 sq mm copper wire, down rod all accessories as required.
S.I.T.C of following rating surface mounted LED tube lightfitting suitable for 230V 50Hz, single phase supply etc. compete as required.
20w/22w LED tube
S/F 20amps SPN MCB industrial Socket:- Supplying and fixing 20 amps 240V, SPN industrial socket outlet, with 2 pole and earth, metal enclosed plug top alongwith 20 amps "C" curve, SP MCB insheet steel enclosure on surace or in recess with chained metal cover for the socket outlet and complete with connections, testing & commissioning etc.
S.I.T.C of following rating recess/surface mounting round/square shape downlight with pressure die cast housing for single phase supply voltage. Luminaire shall conform to IS:3022 part-5/ section-5 or IEC:62722 with all necessary accesories as required.
30W LED Flood light
S.I.T.C of following rating recess/surface mounting round/square shape downlight with pressure die cast housing for single phase supply voltage. Luminaire shall conform to IS:3022 part-5/ section-2 or IEC:62722 with all necessary accesories as required.
15W LED Round Down light
2' X 2' LED Panel Light (34W)
15 Larsen & Toubro 2 HP Starters Control Panel for Submersible Pump
POWER DISTRIBUTION BOARD FOR PUBLIC HEALTH BUILDING Design, Fabrication, Supply, Erection,Testing and commisioning of Powder coated Indoor Type Power Dist. Board (PDB), fabricated out of 14 guage CRCA sheet steel in cubical, compartmentallised, free standing , dust and vermin proof, (degree of protection-IP54)with reinforcement of suitable size angle iron, channel, T -iron or flats as required. Cable gland plates shall be provided on top as well as bottom of the panels. Panels shall be treated with all anti-corrosive process before painting as per specification. Panels shall be suitable for 415V, 3-Phase, Four wire, 50 Hz supply complete with earth bus and lifting hooks as required in case of large panels.Approval shall be taken for each panel before fabrication. (All hardwares like nuts and bolts used shall be Galvanized and Zinc passivated) as per Specification. The PDB shall broadly comprise of the following equipment/components) Incoming Feeders:- Incomer- 63A, TPN MCCB (P-2), 16 kA for 1 sec (Ics=100%Icu) Breaking capacity (Variable thermal rating 80-100%, variable magnetic rating 6-10 times) with factory made silver plated copper spreading links- 3No.(1AC Mains + 1 Changeover + 1 DG I/c) Outgoing Feeders:- 63A TPN MCB 10kA - 05 Nos. 40A TPN MCB 10kA - 02 Nos. 100A TPN Copper bus bar in metal encolsure with fixing clamps Indication lamps(On- Off Trip Power On -- RYB)
Supplying, Installing, Testing & Commisioning cost of Power Distribution Board (PDB) for Admin building all complete with all necessary items as per direction of E/I.
Add 18 % GST (in Basic Rate must fill 12)
Add 1% Labour Cess (in Basic Rate must fill 1)
TRISHANKARA CONSTRUCTION PRIVATE LIMITED
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .