Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.2 LAccepted-AOC | L1 | Accepted-AOC Being lowest and reasonable | |
| 2 | L2₹22.0 L+₹3.5 L (18.8%)Rejected-Finance | L2 | Rejected-Finance Not being lowest | |
| 3 | L3₹22.1 L+₹3.7 L (19.8%)Rejected-Finance | L3 | Rejected-Finance Not being lowest | |
| 4 | L4₹22.4 L+₹3.9 L (21.1%)Rejected-Finance H NO 200 GIRJA NAGAR 37 BN P A C LINE KANPUR 208015 | KANPUR | KANPUR | UTTAR PRADESH | 208015 | L4 | Rejected-Finance Not being lowest | |
| 5 | L5₹22.6 L+₹4.1 L (22.1%)Rejected-Finance | L5 | Rejected-Finance Not being lowest |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
3 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) B/R Chakeri Kanpur
GE (AF) B/R Chakeri Kanpur
ROUTINE, PREVENTIVE AND CORRECTIVE MAINT OF SEWAGE SYSTEM INCLUDING CLEANING OF SEPTIC TANK IN VARIOUS OTM BLDGS AND LIVING IN ACCNS UNDER AGE B/R-II AT AFS CHAKERI KANPUR
2020_MES_368959_2
GE(AF)/CHK/T-20 OF 2020-21
Open Tender
Civil Works
Item Rate
272 days
GE (AF) B/R Chakeri Kanpur
Class E and cat a(i)
8 documents required · 8 mandatory
₹500
GE (AF) B/R Chakeri Kanpur
₹50,000
19 Nov 2020
19 Sept 2020
8 Oct 2020
19 Sept 2020
3 Oct 2020
21 Sept 2020
60 days
Amount
Dismantling of brick work of any description and in any position not otherwise specifically provided for, etc. complete all as specified and directed.
M & L for brick work with sub class `B` bricks straight or curved on plan exceeding 6 m mean radius built in CM (1:4) complete all as specified and directed.
Ditto all as per item No. 2.00 above but except bricks.
Taking down cement plaster of any description including racking out joints and hacking for key and scrubbing down with water etc. complete all as specified and directed.
M & L for rendering 15 mm thick cement plaster in CM (1:4) on fair faces brick work finished even and smooth without using extra cement and applying two coats of cement paint over a coat of cement base primer complete all as specified and directed.
M & L for rendering 10 mm thick cement plaster in CM (1:6) on fair faces brick work finished even and smooth without using extra cement and applying two coats of oil bound distemper over a coat of primer over and including 1-2 mm thick wall care putty complete all as specified and directed.
M & L for rendering 5 mm thick on fair faces of brick work or concrete surfaces in CM (1:3) finished even and smooth without using extra cement and preparation of new plastered surfaces and applying three coat of white wash on ceiling complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided complete all as specified and directed.
Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided for complete all as specified and directed.
M & L for pre-cast RCC (1:2:4) type B-1 using 20 mm graded stone aggregate as in manhole cover / drain covers etc and set in CM (1:6) complete all as specified and directed.
M & L for PCC (1:4:8) Type D-2 using 40 mm graded stone aggregate as in foundations filling and mass concrete etc. complete all as specified and directed.
M & L for PCC (1:3:6) Type C-2 using 40 mm graded stone aggregate as in surface channel and drain complete all as specified and directed.
M & L for 75 mm thick PCC (1:3:6) type C-2 using 40 mm graded stone aggregate as in flooring /paving/plinth protection including finishing surfaces even & smooth without using extra cement complete all as specified and directed.
Extra for forming fair finished drain or channel 60 cm inner girth in cement concrete, using extra cement including form, moulds, mitred/stopped ends etc. complete all as specified and directed.
Dismantling of cast iron reinforced concrete drain pipes, jointed in cement of any size, any thickness complete all as specified and directed.
M & L for 60 thick mm machine pressed precast concrete interlocking paver block glazed, coloured of any shape and size confirming to IS 15658-2006, M-35 grade jointing in grey cement and pointing with pigment complete all as specified and directed.
M & L for 100 mm thick PCC (1:4:8) type D-2 using 40 mm graded stone aggregate as in sub-base and mass concrete complete all as specified and directed.
M & L for 25 mm thick (consolidated thickness) sand filling /sand cushioning for bed or bedding layer for laying the interlocking tiles/block etc. complete all as specified and directed.
Demolition or breaking up drain pipes of 150 mm dia (SGSW, AC or reinforced concrete) set in cement mortar including breaking and removal of bedding and hunching complete all as specified and directed.
Ditto all as per Item No 19.00 above but for 200 mm dia drain pipe.
M & L for 150 mm bore RCC Pipe with collars, class NP-2 laid and jointed with cement mortar (1:2) complete all as specified and directed.
Ditto all as per Item No 21.00 above but for 200 mm dia drain pipe.
M & L for concrete bed for 150 mm dia drain pipes in PCC (1:4:8) type C-2 using 40 mm graded stone aggregate including packing under and haunching against sides of pipe after they are laid and tested complete all as specified and directed.
Ditto all as per Item No. 23.00 above but for 200 mm dia drain pipe.
Excavation in trenches not exceeding 1.50 m wide and not exceeding 1.50 m depth and getting out in any type of soil complete all as specified and directed.
Returning, filling-in including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick complete all as specified and directed.
Removing excavated soil not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr from the starting point complete all as specified and directed
S & F in repair 100 mm dia CI soil, sand cast, waste and vent pipes in any length with or without ears, jointed with cement mortar (1:2) laid as in trenches or in floor complete all as specified and directed.
Ditto all as per item No 28.00 above but for 75 mm dia pipe.
S & F in repair 100 mm dia cast iron soil, sand cast, waste and vent pipes in any length with or without ears, fixed to walls using suitable fixing arragement such as FI clamps etc. complete all as specified and directed.
Ditto all as per item No 31.00 above but for 75 mm dia pipe.
S & F 75 mm bore, cast iron bends of any radius complete all as specified and directed.
S & F 100 mm bore, cast iron bends any radius complete all as specified and directed.
S & F 100 mm CI bore branch pipes, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S & F 75 mm CI bore branch pipes, single (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S & F 100 mm CI bore branch pipes, double (equal or unequal) ordinary or inverted (spigot or socket type) or with parallel branches complete all as specified and directed.
S & F 100 mm CI bore sockets double collars complete all as specified and directed.
S & F 100 mm CI branch piece double `Y`, equal or unequal complete all as specified and directed.
Cleaning of the blocked sewage lines by rodding between manholes and removing muck sludge/silt/liquid mud etc. (including foul position) from pipes and manhole including taking down cover slab of any type, thickness and size carefully and re-fixing in same position after necessary cleaning and removing the cleaned sludge out side of MD land in sealed containers complete all as specified and directed.
Cleaning of septic tank at diffrent locations of any description up to any users capacity by mechanical means only with using sewage tankers/truck mounted hydraulic jet pressure mechine with heavy duty flushing the sewage line and with heavy duty sewage suction pump including other necessary arrangements such as sweepers to clean up the site after work in the following steps :(i) Bailing out /dewatering of septic tank (ii) Removing of all sludge/waste material (liquid/semi liquid /solid/semi/solid) silt, bricks bats debris mud soil , polythene etc any kind of materials from all chambers of the septic tank, clean the floor and walls of the tank after removing the same completely. (iii) Removing the blockage of inlet/outlet pipe in any depth , in any situation (iv) Finally flushing septic tank including inlet/outlet with adequate water and making fully functional the septic tanks with entire satisfaction of Engineer-in- charge and removing retrieved/takingout all type of materials, sludge/soil waste liquid/semi liquid /solid/ semi solid/ or any unwanted materials of any kind etc outsidethe periphery of defence land at his own arrangement into packed container where sanitary hazards do not take place as per directions/instructions of civil authority and buried in excavated pits in suitable size and depth and covering the same with the soli obtained from excavation of pit including all excavations and earth work including applying bleaching powder to maint hygiene. Adequate water for flush out sludge to be arranged by the contractor without any extra cost and including taking out manholes cover and re-fixing the same after cleaning/removing blockage, fully functional complete all as specified and directed. (Note :- A particularr septic tank which is undertaken once for cleaning and paid for, shall be kept function or entire contract period and no extra payment shall be made for repetitive cleaning if required).
Taking out old brick bats from sokage pit /wells and remoing the same, out side the periphery of defence land at his own arrangements where sanitary hazards do not take place as specific directions /instructions of civil authority (Note :- Unit rate quoted by tenderer shall include taking out brick bats and removing including loading/unloading and transportation etc)
M & L for filling with aggregates of broken bricks, size of gauge 80 mm to 150 mm as in soakage pits/ soakage wells complete all as specified and directed.
M & L for 15 mm thick rendering in CM (1:4) on fair faces of brick work on internal surfaces and finished even and smooth without using extra cement mixed with WPC @ 3 % by weight of cement complete all as specified and directed. (WPC shall be measured and paid separately)
Supply only integral water proof compound complete all as specified and directed.
M & L for Reinforced Cement Concrete (1:2:4) Type B-1 using 20 mm graded granite stone aggregate for slabs supported on walls, beams and columns, in floors, roofs, landings and in shelves and the like including all necessary form work complete all as specified and directed.
Cutting into existing manholes for connecting new drains making good to pipe and rendering cutting out existing benching for and forming branch channel( ½ round or ¾ section) in cement concrete (1:2:4) type B-1 using 20 mm graded stone aggregate, making surface smooth finished and reforming benching as required, complete all as specified and directed.
M & L for mild steel TMT bars 10 mm dia. and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia., or securing with clips complete all as specified and directed.
M & L for PCC (1:2:4) type B-1 using 20 mm graded granite stone aggregate as in copings and the like including weathering, slightly rounded or chamfered angles and throating, complete all as specified and directed.
Taking up or down 15 mm dia GI steel tubing and connection including cleaning for re-fixing or removal to store complete all as specified and directed.
Re-fixing of 15 mm bore old steel tubing and connection in new or old position complete all as specified and directed.
M & L for GI tubing 15 mm dia medium grade galvanised with all fittings and fixed to wall and ceilings or laid in floors complete all as specified and directed.
Taking up or down 20 mm dia GI steel tubing and connection including cleaning for re-fixing or removal, complete all as specified and directed.
Re-fixing of 20 mm bore old steel tubing and connection in new or old position complete all as specified and directed
M & L for GI Tubing 20 mm dia, medium grade galvanised with all fittings and fixed to wall and ceilings or laid in floors complete all as specified and directed.
Dismantling of structural steel work as in gates, doors etc. excluding framed truss complete all as specified and directed.
M & L for 1.60 mm thick mild steel plain, black sheet in hearths covering to door shutters, covering to door chowkhats frame, water tank, water throughs ducts etc cut to size edges beaded if directed holes punches fixed to wood or steel members etc complete all as specified and directed.
S & F framed brackets of angles or tees with web and flanges cut to shape , drilled and countersunk for screw, including bending and welding angles as necessarry gusset plates riveting, etc n.exc 10 kg each bracket confirming to Fe-290 Grade -E 165 (brackets over 10 kgs each to be measured under structural steel) complete all as specified and directed.
M & L for salt glazed stoneware gully traps of size 150 mm x 150 mm square or rounded, mounted type `P` shape complete all as specified and directed.
M & L for preparation of new steel surfaces and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S & F in repairs 75 mm dia cast iron soil waste and vent pipe in any length with or without ears, with cement joint extra over cast iron pipe and fittings if lead joint is provided in lieu of cement joint laid in tranches or in floor complete all as specified and directed.
S & F in repairs PVC waste pipe 32 mm dia complete all as specified and directed.
S & F in repair PVC waste pipes 40 mm dia, suitable for urinal complete all as specified and directed.
M & L for industrial, Endura heavy duty, virtified, scratch, stain and acid resistant tiles of size 300 mm x 300 mm x 10 mm having breacking strength not less than 1700 N, water absorption less than 0.5%, laid and jointed with neat cement slurry, with minimum 3 mm spacer, laid as in floor complete all as specified and as per direction of manufacterer's instructions.
Dismantling floor, hearth or wall tilling including cement mortar beading (but not backing), removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
Dismantling of stone slabs and tiles laid bedded and pointed in any mortar of any description or thickness in floors aprons etc. complete all as specified and directed.
M & L for glazed colour ceramic tiles in vertical surfaces of size 350mm x 250 mm x 7 mm/450 mm X 350 mm X 7 mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10 mm thick cement plaster in CM (1:6) complete all as specified and directed.
M & L for joint free, coloured, non skid ceramic tiles 7 to 8 mm thick (square/rectangular) area of each tiles exceeding 0.06 Sqm but not exceeding 0.11 Sqm in floors etc set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15 mm thick screed bed or bedding layer in CM (1:6) complete all as specified and directed.
M & L for providing two coat of master seal 550 or equvalient to prevent leakage /seepage through sunken floor over prepared surfaces complete all as specified and directed.
M & L for PCC (1:5:10) type E-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and directed.
M & L for rendering 10 mm thick in CM (1:4) on fair faces of brick work or concrete surfaces, finished even and smooth complete all as specified and directed.
S & F in repair 40 mm bore GI tubing medium grade galvanised with all fittings complete under floor as spout pipe complete all as specified and directed.
M & L for 25 mm thick PCC (1:2:4) type B-0 using 12.5 mm graded stone aggregate as in sub-base complete all as specified and directed.
M & L for 18 to 20 mm thick marble work (Table rubbed and polished) as in steps, jambs, pillars window cills, cooking plateforms and like, jointing in cement mortar (1:4) and pointing in white cement (1:2) using marble dust with admixture of pigment to match with marble of any shade other than white and black colour over and including 20 mm thick screed bed in CM (1:6) including dismantly old marble work complete all as specified and directed.
S & F in repair Vitreous china squatting pan 'Orrisa' pattern of size 580 mm x 440 mm white integral floor rests ( excluding flushing cistern ) including connection to trap and to flushing pipe anti syphonage pipe etc. including making good to floor, complete all as specified and directed.
S & F in repair vitreous china urinals, half stall type, white with grating union for discharge pipe of wall type complete including providing and fixing plugs, bedding urinal against wall in CM (1:2), securing urinal to plug with and including 60 mm long brass screw pointing around urinal back in cement, fixing automatic flushing cistern with brackets, flush pipe grating and union for discharge pipe complete all as specified and directed.
S & F 110 mm x 110 mm dia PVC (SWR) P trap complete all as specified and directed.
M & L for coloured, matt elevation ceramic tiles, 3-D, with high defination, disgitally printed, as per ISO-13006/EN14411, 300 mm x 450 mm x 7to 8 mm thick or as required size on vertical surface as dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles, over and including 10 mm thick cement plaster as backing coat in CM (1:3) complete all as specified and directed.
M & L for coloured, clad care tiles with vitrified body, mat surface, germ free, tiles of size 240 mm x 75 mm x 6 mm thick or required size on vertical surface as in dado/skirting, set and jointed in neat cement slurry and pointed in white or coloured cement to match with the colour of the tiles, over and including 10 mm thick cement plaster as backing coat in CM (1:3) complete all as specified and directed.
Providing and deployment of safaiwala to attend and rectify of sewage system complaints on daily routine basis as per complaint lodged by users at complaint cell of AGE B/R-II sub division complete all as specified and directed.
Notes:- (i) All the tools and plants and other allied arrangement for making sewage line functional will be made by the contractor without any extra cost to the Govt and cost shall be deemed to be included with quoted unit rate. (ii) The safaiwala will report daily at 8.30 hours at complant cell of AGE B/R-II sub -division & will depot the cell 1630 hours after attending all complaints. (iii) Details of bldg Nos or locations / position of septic tank manhole, soakwell shall be mentioned against each job in register.
M/S ASM ENTERPRISES
M/S KUSHWAHA BROTHERS
DHARM ENTERPRISES
J.B.ENTERPRISES
M/S SDS Construction Co.
M/s R.V. Constructions
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .