Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹42.1 LAccepted-AOC | L1 | Accepted-AOC Lowest rate quoted | |
| 2 | L2₹43.3 L+₹83,633.60 (1.97%)Rejected-Finance | L2 | Rejected-Finance Higher rate quoted than L1 | |
| 3 | L3₹45.9 L+₹3.5 L (8.13%)Rejected-Finance | L3 | Rejected-Finance Higher rate quoted than L1 | |
| 4 | L4₹46.5 L+₹4.1 L (9.57%)Rejected-Finance PO BUD BUD DIST BURDWAN WEST BENGAL PIN 713 403 | BUD BUD | BURDWAN | WEST BENGAL | 713403 | L4 | Rejected-Finance Higher rate quoted than L1 | |
| 5 | L5₹47.5 L+₹5.0 L (11.9%)Rejected-Finance | L5 | Rejected-Finance Higher rate quoted than L1 |
Tender Value
₹48.2 L
EMD Value
₹96,400
Closing Date
3 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE PANAGARH
GARRISON ENGINEER PANAGARH, MILITARY ENGINEER SERVICES, PO-PANAGARH, DIST-BURDWAN, WEST BENGAL, PIN-713420
All as per BOQ
2022_MES_544654_2
8400-841/E8
Open Tender
Civil Works
Works
210 days
PANAGARH
Class D and Category a (i) (Building)
6 documents required · 6 mandatory
₹500
GE PANAGARH
₹96,400
Yes
10 Nov 2022
13 Sept 2022
5 Oct 2022
13 Sept 2022
3 Oct 2022
19 Sept 2022
60 days
Amount
Dismantling of asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings complete all as specified and directed.
Dimantling of wall and ceiling boards (fibre, pulp, insulation boards etc) any thickness including cover fillets complete all as specified and directed.
Dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed
Demolition of cement concrete (un-reinforced) in ground floors and paving n.exceeding 15cm thick above or below ground level removing rubbish off from the site complete all as specified and directed
Demoltion of Concrete of any description and in any position not otherwise specifically provided for removing rubbish off from the site complete all as specified and directed
Demolition of brick/stone masonry, built in cement mortar including all quoins, arches, pillars etc but exluding ashlars facings, dressed stone work and pre-cast concrete articles removing rubbish off from the site complete all as specified and directed
Taking down cement plaster on brick or concrete walls, etc including raking out joints, hacking for key, scrubbing down with water etc removing rubbish off from the site complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed
M&L for PCC (1:4:8), type D2, (using 40 mm graded stone aggregate) as in foundations, filling and mass concrete complete all as specified and directed
M&L for mild steel TMT bars 10mm dia and over cut to length bend to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or secruing with clips complete all as specified and directed
M&L for TMT bar 6mm to 8mm dia cut to length bend to shape required including cranking bending spirally for hooping for columns hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or secruing with clips complete all as specified and directed
All as per item No 11.00 mentioned here-in-above but 5mm dia and over upto and including 10mm dia in stirrups, spacers and binders complete all as specified and directed
M&L for hard drawn steel wire fabric, of weight nexc 4kg per sqm, cut to lengths, bent to shape required and tying with and including mild steel wire (annealed) not less than 0.9mm in dia supplied and fixed in reinforcemnt complete all as specified and directed
M&L for M-25 Design mix (using 20mm graded stone aggregate) as in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc.; basement slabs, underreamed piles and mass concret complete all as specified and directed
M&L for M -25 Design mix (using 20mm graded stone aggregate) as in chajjas complete all as specified and directed
M&L for M-25 Design mix (using 20mm graded stone aggregate) beams, cantilevers, bressummers, lintels over 1.5m span complete all as specified and directed
M&L for M-25 Design mix using 20mm stone aggregate Columns, pillars, piers, posts and struts complete all as specified and directed
Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batte complete all as specified and directed
Formwork to chullah hoods, cha?jjas, troughs and similar items including edge complete all as specified and directed
Formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams, etc complete all as specified and directed
Formwork to sides of pillars, posts, struts, piers, columns and stanchions complete all as specified and directed
M/L for brickwork with fly ash bricks, straight or curved on plan to any radius in half brick thick walls, built in CM (1:4) complete all as specified and directed
M&L for brickwork with fly ash bricks, straight or curved on plan exc 6m mean radius, built in cement mortar (1:6) complete all as specified and directed
M&L for moorum filling in floors or pavings, laid in layers n.exc. 15 cm thick, spread, levelled and rammed including watering complete all as specified and directed
M&L for hardcore of broken stone or boulders of gauge n.exc 63mm, deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface complete all as specified and directed
M&L for 75mm thick PCC 1:4:8, type D-2, (using 40mm graded stone aggregate) in sub base of floor/paving etc complete all as specified and directed.
M&L for 75mm thick PCC 1:2:4, type B-1, (using 20mm graded stone aggregate) in sub base of floor/paving with nominal reinforcement et complete all as specified and directed.
S&F for pre-painted galvaume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
M&L for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc complete all as specified and directed
Preparation of new painted surfaces of steel and applying two coat synthetic enamel paint to steel surfaces of any description not otherwise described over 10cm width or girth complete all as specified and directed.
S&F anodised aluminium snap grid frame work for false ceiling with hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceilling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia 40mm long including 4 mm thick pre-painted decorative non asbestos fibre cement building boards fixed or laid/ inserted to timber/ GI/ Aluminium framework with screws complete all as specified and directed
S&F Stainless steel wire cloth. 0.36mm nominal dia of wire and average width of aperture 1.40mm and fixed complete all as specified and directed
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:4) mixed with water proofing compound on wall and finishing fair and even complete all as specified and directed (Note: WPC shall be measured and paid under separate item).
Supply only integral water proofing compound complete all as specified and directed. (Make : Pidilite Industries/ Impermo/Snowcem India Ltd/Sika)
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in cement mortar (1:6) on wall and finishing fair and even complete all as specified and directed
M&L for non skid ceramic tiles, coloured, joint free type, 7 to 8 mm thick (square/rectangular) area of each tile exc 0.18 sqm but nexc 0.38 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layers of cement mortar 1:4 complete all as specified and directed.
All as per item No 37.00 mentioned here-in-above but in vertical surface as in skirting over and including 10mm thick rendering in cement mortar 1:4 complete all as specified and directed.
M&L for non skid ceramic tiles, coloured, joint free type, 7 to 8 mm thick (square/rectangular) area of each tile exc 0.06 sqm but nexc 0.11 sqm in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 15mm thick screed bed or bedding layers of cement mortar 1:4 complete all as specified and directed.
M&L for glazed ceramic tiles in vertical surface 350x 250x 7 mm / 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match complete all as specified and directed.
M&L for providing 75mm thick PCC (1:3:6) type C2 (using 40mm graded stone aggregate) as in plinth protection and finished the surface even & smooth without using extra cement complete all as specified and directed.
M&L for providing PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in surface channels and drain complete all as specified and directed
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified and directed.
M&L for applying two coats of distemper oil imulsion over a coat of cement primer including preparation of newly plastered surfaces, complete all as specified and directed.
M&L for applying two coats of distemper oil imulsion over a coat of cement primer after complete removal of existing treatment all as specified and directed. (Make: M/s Tractor Acrylic Distemper of Asian/M/s Bison Acrylic Distemper of Berger, M/s No 1 Premium Acrylic Distemper of Shalimar).
M&L for applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10sqm over new or previously untreated surfaces complete all as specified and directed. (Make: M/s Apex Ultima of Asian/ Weather Coat all guard of Berger/Xtra Tough of Shalimar)
All as per item No 46.00 mentioned here-in-above but after complete removal of existing treatment complete all as specified and directed
M&L for preparation of old painted steel or iron surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
M&L for preparation of old painted wood and wood based surfaces of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed.
Taking down Chowkhats or frames n.exc. 1.5 sqm each with shutters (without taking off shutters from the frames) complete all as specified and directed
Taking down Chowkhats or frames exc 1.5 sq. m but n exc 4 sq. m each (without taking off shutters from the frames) complete all as specified and directed
S&F powder coated aluminium (minimum thickness of powder coating 50 micron) work for doors, windows, ventilators and partitions (Fixed portions) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-Charge
Powder coated aluminium (minimum thickness of powder coating 50 micron) for shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/neoprene gasket required (Fittings shall be paid for separately) with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS:1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ paneling, C.P. brass/ stainless steel screws all complete as per architectural drawings and the directions of Engineer-in-charge.
Framed work such as grills, gratings, etc.. with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe.290.Gde-E-165
M&L for rendering 10 mm thick on fair faces of roof surfaces or concrete surface in CM (1:4) using with WPC complete all as specified and directed. (Note: WPC shall be measured and paid seperately)
M&L for preparation of new surfaces of roof and applying two coats of Polyurethane (PU) acrylic based water proofing liquid compound over and including one coat of self priming primer @ one litre per 10 Sqm with reinforcing fabric sheet as per manufacturer's instructions to stop leakage/seepage from roof/wall complete all as specified and as directed by the Engr-in-Charge. (Notes :- (i). As per description of this item, minimum two coats of Polyurethane (PU) acrylic based water proofing liquid compound over one coat of primer shall be carried out as per manufacturer's instruction. Please note no price adjustment shall be made, if as per manufacturer's instructions more coats of Polyurethane (PU) acrylic based water proofing liquid compound and primer are required for roof treatment. (ii). Quoted Rate shall be deemed to be included for work in building/structure of any height).
Surface excavation n.exc (n.exceeding) 30 cm deep and averaging 15cm deep and getting out in nsoft / loose soil complete all as specified and directed
Removing excavated material n.exc. 50m and depositing where directed at a level n.exc. 1.5 m above the starting point complete all as specified and directed
M&L for 100mm thick PCC 1:4:8 type D2 (using 40mm graded stone aggregate) as in sub base or base course finished even annd fair complete all as specified and directed
M&L for sand filling in floors or pavings, laid in layers n.exc 15 cm thick, spread, levelled and blinded with earth and rammed incl watering complete all as specified and directed.
M&L for 60 mm thick machine pressed precast concrete interlocking paver block with grey cement and pigments any shape and size confirming to IS 15658-2006 M-35 Grade complete all as specified and directed
M&L for PCC 1:3:6 type C1 (using 20mm graded stone aggregate) as in kerb stone including necessary form work complete all as specified and directed
Excavation in trenches in any type of soil n.exc 1.5 m wide and n.exc 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits,manholes, pier holes, etc. n.exc 10 sqm on plan and n.exc 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed
Returning filling in soft /loose excavated soil including spreading leveling watering and well ramming in layers n.exc 25 CM and all as specified and directed.
Providing precast cement concrete louvres and jallies, 25mm thick (mea sured solid), including all mould- ings but excluding frame (Pre cast frame shall be measured separately and paid for under item set in CM 1:4 complete all as specified and directed
Excavation over areas n.exc 1.50m deep and getting out in soft/loose soil complete all as specified and directed.
M&L for 200mm thick (in two layers of each 100mm thick) in pavings, with mix of fly ash, clinker & stone dust in the proportion of 1:3:6 (i.e. 10% fly ash, 30% clinker and 60% stone dust) laying in layers n.exc 30cm thick, watering, ramming and compacted with hand/power roller 8 to 12 tonn roller to required camber and gradient complete all as directed by Engineer-in-Charge. Laid in layers n.exc 15cm thick, spread, levelled and blinded with earth and rammed including watering Kankar or laterite, spread, rolled and consolidated to gradient and camber required complete all as specified and directed.
M&L for 150mm thick soling (or sub base) with broken boulders or quarried stone, inter stices filled, surface formed and rolled and consolidated to required gradient and camber complete all as specified and directed.
M&L for rolling and consolidating formation surfaces in cutting with exc 8 n.exc 12 tonne capacity power road roller complete all as specified and directed.
M&L for 7.5 cm thick (compacted thickness) WBM, with coarse aggregates of grading 2 (63 to 40 mm size) or of grading 3 (50 to 20mm size) spread, rolled and consolidated to gradient and camber required complete all as specified and directed
M&L for 100 mm thick plain cement concrete (1:4:8) type D2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
M&L for 100 mm thick plain Cement concrete type B-2, 1:2:4 (using 40mm graded stone aggregate) as in hardstanding laid in panels with and including use and waste of formwork and to divide the area in panels and finishing the surface even and fair complete all as specified and directed.
M&L for plain cement concrete 1:3:6 type C1 (using 20mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs complete all as specified and directed
M&L for forming Contraction (Dummy) joints 50mm deep x 10mm wide, filled with sealing compound of grade A complete all as specified and directed.
S&F capacity 2000 Ltrs rotational moulded polyethylene water storage tanks (Cylindrical, 3 layer,vertical with closed top) confirming to relevent IS complete including provision of all inlet outlet overflow and drain pipe fitting complete all as specified and directed by Engineer in Charge
S&F of high pressure PTMT float valve with epoxy coated alluminium rod and high density polythelene ball screwed for iron pipe 25 mm dia with fly nut complete all as specified and directed.
M&L for 25 mm bore gate valve cast copper alloy screwed down high pressure with clutch handle screwed both ends for Iron pipe complete all as specified and directed.
S&F 25 mm bore GI Tubing medium grade in Trenches/ Floor/Pillar and connection including fitting like socket /Union/Tee/Reducer Nipple etc complete all as per specified and directed.
S&F 50 mm bore GI Tubing medium grade in Trenches/ Floor/Pillar and connection including fitting like socket /Union/Tee/Reducer Nipple etc complete all as per specified and directed.
EM Portion M&L for point wiring for light point/ fan point, one light/fan/exhaust fan point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor ,PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed. (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
All as per item No 80.00 above but 5 Amp socket on same board with other switches complete all as specified and directed.
M&L for wiring for 5 Amps socket out let on independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
M&L for wiring for 15 Amps socket out let on independent Boards controlled by one, one way switch using 4 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC concealed conduits and fittings, including pressed steel terminal switch boxes , 3 mm thick bakelite sheet top cover (ISI Marked) fitted with Chromium plated brass screws & washers and 4.0 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed (Note: Quoted rate deemed to be included for necessary chasing/cutting and making good the surface)
S&F switch piano flush type, single pole , 5/6 Amps, one way complete all as specified.
S&F switch socket combination, 2 in 1 multipurpose 5 pin , (5/6 Amps ) complete all as specified.
S&F socket outlets 2 in 1, 5/6 Amps, 230/240 V complete all as specified and as directed .( For Same Board only)
S&F switch socket combination, 5/16 Amps 5 in 1 flush type controlled by one switch complete all as specified.
S&F ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified.
S&F stepped type electronic fan regulator flush type 240 Volts ISI marked complete all as specified .
S&F 01x 18 W LED batten light fittings, with T-8 tube, lighting fixture with extruded polycarbonate complete with all accessories and connection from ceiling rose with twin core twisted flexible copper conductor cable with suitable size and earthing complete all as specified and directed.
S&F security light fittings 25 watts, minimumm lumen output 100 lumen/Watt, made up of pressure dia cast housing with prismatic polycarbornate diffuser and individual LED with secondary optic and IP65 including necessary connection complete suitable for pole dia 25mm complete with all accessories including connected with twin core twisted flexible copper conductor of suitable size complete all as directed. Make - Bajaj/Crompton/Phillips
S&F lamp holder, PVC/polycarbonate type with back plate straight or angular suitable for batten fittings complete all as specified and directed.
S&F 9W LED light fitting wall mounted batten 2ft , extruded polycarbonate, enivromental friendly, heat sink provided for efficent heat dissipation and integrated electronic driver for 9 watt, 6000K including necessary connection complete all as specified and directed.
S&F metallic exhaust ventilation fan of sweep 300 mm sweep, 230volt AC complete with louver and all asssesories including cutting hole of suitable size, making good surface by doing plaster and applying two coat of distemper complete with fixing connected with twin core twisted flexible copper conductor (23/0.0076) of size complete all as specified and directed. (Note: Cost of cutting and making hole for fixing exhaust fan shall be deemed to included in quoated rates)
S&F ceiling fan BLDC 1200mm size , star 5 rated, ISI mark, 240V, 50 Hz all as specified and directed. (Make: M/s Crompton/M/s Bajaj/M/s Havells)
S&F submain two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked), concealed, including 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified.
S&F two single core, 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC conduit (ISI marked), concealed, including 6 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified.
S&F epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Triple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel, neutral link and incoming contact complete all as specified and directed.
S&F epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 8 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
S&F MCCB TPN 125 Amps, 25kA, 240 Volts,ISI marked and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs including necessry connection complete all as specified and directed. (Note : Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F MCB SPN 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note : Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
S&F XLPE armoured cable 16 sqmm 4 core,1100 volts grade heavy duty cable,ISI marked passing through pipe, with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed complete all as sepcified.
Supply and lay for dry river sand filling for cable protection with a layer of 8cm deep before laying and 15cm covering above the top edge of cable after laying complete all as specified and as directed. (Note : Punned thickness shall be measured).
M&L for sub class B bricks locally available of size 25 x 12.5 x 7.5 cm laid dry width wise across the line of cable in trenches for protection of UG cable complete all as specified and directed.
M&L for earthing complete with galvanised mild steel earth plate electrode 600x600x6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire 4 mm dia as earth wire electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments, 20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion complete all as specified and directed. (Note :- (i) If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department. (ii) Testing to be carried out by the contractor in presence of Engr- in- Charge , entered in the eath testing register, prepared and to be maintained by the contractor & submited to Concerned JE E/M. (iii) T&P and testing instrument (Meger) to be provided by the contractor at own cost).
M&L for wiring for 5 Amps socket out let on independent Boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables, PVC casing capping and fittings, including PVC switch boxes (ISI Marked) fitted and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS cable earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified.
S&F two single core, 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade drawing in and including suitable size PVC casing and caping (ISI marked) including 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, PVC insulated unsheathed 1100 Volts grade earth wire complete all as specified.
S&F MCB SPN 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed.
S&F Heavy Duty Metallic high speed Turbo force Padestal fan of 450 mm sweep size with stand complete all as directed by Engr-in-Charge.
Supply, laying/fixing/connecting, testing and commissioning of 10 Sqmm x 4.0 core LT under ground cable XLPE insulated, screened, PVC bedded, galvanised steel strip or wire armoured, electric cable (heavy duty) with multistranded aluminium conductor, 1100 Volts grade in trenches/on wall/poles laid in ducts/inside protection pipe of the following cross sectional area including cable glands,lugs and suitable size of MS saddle clips (where ever cable laid in ceilings / walls without cable duct) all as directed by the Engr-in-Charge. (Note: Excavation,sand cushioning, brick will be measured and paid separtely).
SUPARNA TRADING
MS ROYAL CONSTRUCTION INDEX NO 158 2010 BKP
ROY ENTERPRISE
M/S TRIVENI BUILDERS
FRIENDS CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .