Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Rejected-Technical | Rejected-Technical the bidder does not submit Audited balance sheet among previous three years |
Tender Value
₹1.6 Cr
EMD Value
₹3.3 L
Closing Date
28 May 2026, 3:30 pmClosed
HOD ENGINEERING
CWC REGIONAL OFFICE PANCHKULA
AMC WORKS ZONE 5 PANCHKULA
2026_CWC_275949_1
E NIT_CWC/RO_ PKL/Engg/AMC/ZONE-5/26-27/09
Open Tender
Miscellaneous Works
Percentage
365 days
CWC PANCHKULA HARYANA
AS PER TENDER DOCUMENT
9 documents required · 9 mandatory
₹0
₹3.3 L
9 Jul 2026
14 May 2026
29 May 2026
14 May 2026
28 May 2026
14 May 2026
14 May 2026 - 27 May 2026
DSR Civil 2023
Providing and laying cement concrete in retaining walls, return walls,walls (any thickness) including attached pilasters, columns, piers,abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets,sunken floor etc., up to floor five level, excluding the cost of centering, shuttering and finishing:
1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).)
Providing and laying in position ready mixed or site batched design mixcement concrete for plain cement concrete work; using coarse aggregateand fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommendedproportions as per IS: 9103 to accelerate / retard setting of concrete, toimprove durability and workability without impairing strength; includingpumping of concrete to site of laying, curing, carriage for all leads; butexcluding the cost of centering, shuttering and finishing as per directionof the engineer-in-charge; for the following grades of concrete.Note: Extra cement up to 10% of the minimum specified cement contentin design mix shall be payable separately. In case the cement contentin design mix is more than 110% of the minimum specified cementcontent, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement
Concrete of M20 grade with minimum cement content of 270 kg /cum All works above plinth and upto floor V level
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.( AS PER THUMB RULE 1SQM REQUIRES 1SQM -12.5KG STEEL)
Centering and shuttering including strutting, propping etc. and removal of form for :
Suspended floors, roofs, landings, balconies and access platform
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Mirror polishing on marble work/Granite work/stone work where ever required to give high gloss finish complete
Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately).
Second class teak wood
Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) decorative type, core of block board construction withframe of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters..
35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws
Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters (over all area of door shutter to be measured
Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured)
Providing and fixing ISI marked oxidised M.S. sliding door bolts with nuts and screws etc. complete (Copper oxidised as per IS 1378
Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodiccoating not less than grade AC 10 as per IS :1868 ) transparent or dyedto required colour or shade, with necessary screws etc. complete :
Providing and fixing frame work for partitions/ wall lining etc. made of 50x50x1.6 mm hollow MS tube, placed along the walls, ceiling and floor in a grid pattern with spacing @ 60 cm centre to centre both ways (vertically & horizontally) or at required spacing near opening, with necessary welding at junctions and fixing the frame to wall/ ceiling/ floors with steel dash fasteners of 8 mm dia, 75 mm long bolt, including making provision for opening for doors, windows, electrical conduits, switch boards etc., including providing with two coats of approved steel primer etc. complete, all as per direction of Engineer-in-charge.
Providing and fixing Pre -laminated medium density fibre board exterior grade (Grade-I) IS:14587:1998 marked, to frame, backing or studding with screws etc. complete (Frames, backing or studding to be paid separately).
Pre-laminated with decorative lamination on both side exterior Grade - I MDF Board 18 mm thick conforming to IS:14587
25 mm wooden planking, tongued and grooved in flooring, including fixing with iron screws complete with :
Second class teak wood
12 mm cement plaster of mix
1:6 (1 cement: 6 fine sand)
6 mm cement plaster of mix :
1:3 (1 cement : 3 fine sand)
20 mm cement plaster of mix
1:4 (1 cement: 4 coarse sand)
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm
Painting with synthetic enamel paint of approved brand and manufactureto give an even shade
Two or more coats on new work
Providing and applying white cement based putty of average thickness 1mm, of approved brand and manufacturer, over the plastered wall surfaceto prepare the surface even and smooth complete.
Applying priming coats with primer of approved brand and manufacture,having low VOC (Volatile Organic Compound ) content.
With water thinnable cement primer on wall surface having VOC content less than 50 grams/litre
Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq.meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground, all complete as per direction of Engineer-in-Charge.
Dismantling steel work in built up sections in angles, tees, flats andchannels including all gusset plates, bolts, nuts, cutting rivets, weldingetc. including dismembering and stacking within 50 metres lead
Channels, angles, tees and flats
Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
Providing and laying matt finished vitrified tile of size 300x300x9.8 mmhaving with water absorption less than 0.5% and conforming to IS: 15622of approved make in all colours and shades in for outdoor floors such asfootpath, court yard, multi modals location etc., laid on 20 mm thick baseof cement mortar 1:4 (1 cement : 4 coarse sand) in all shapes &patternsincluding grouting the joints with white cement mixed with matchingpigments etc. complete as per direction of Engineer-in-Charge
Providing and fixing aluminium work for doors, windows, ventilators andpartitions with extruded built up standard tubular sections/ appropriate Zsections and other sections of approved make conforming to IS: 733 andIS: 1285, fixing with dash fasteners of required dia and size, includingnecessary filling up the gaps at junctions, i.e. at top, bottom and sideswith required EPDM rubber/ neoprene gasket etc. Aluminiumsectionsshall be smooth, rust free, straight, mitred and jointed mechanicallywherever required including cleat angle, Aluminium snap beading forglazing / panelling, C.P. brass / stainless steel screws, all complete as perarchitectural drawings and the directions of Engineer-in-charge. (Glazing,paneling and dash fasteners to be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50 micron ground floor or first floor windows replacement
For shutters of doors, windows & ventilators includingproviding and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 4.0 mm thickness (weight not lessthan 10kg/sqm
Providing and fixing aluminium round shape handle of outer dia 100 mmwith SS screws etc. complete as per direction of Engineer-in-charge
Powder coated minimum thickness 50 micron aluminium
Providing and applying integral crystalline slurry of hydrophilic in naturefor waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage &water treatment plant, tunnels / subway and bridge deck etc., preparedby mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 partswater) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostaticpressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50 mm. The work shall be carried out all complete as per specification and the direction of the engineer-in-charge. The product performance shall carry guarantee for 10 years against any leakage.
For vertical surface two coats @ 0.70 kg per sqm per coat
For horizontal surface one coat @1.10 kg per sqm.
Providing and fixing GI perforated metal ceiling tile 0.5x600x600mm with silhouette runner grid with main T at 1.5m and stitched cross T at 0.6m suspended from RCC roof,truss/angle of approved make: Saint Gobain/Armstrong
Providing and fixing ACP wooden series sheet with necessary screws/nuts & bolts/ nails with matching/ approved shade.
Description
DSR Electrical 2025
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.
Group C
Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.
5/6 amps switch
15/16 amp switch
3 pin 5/6 amp socket outlet
6 pin 15/16 amp socket outlet
Bell push
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
Supplying and fixing following size/ modules, GI box alongwith modular base & cover Plate for Modular Switches in recess etc. as required.
1 or 2 Module
3 Module
4 Module
6 Module
12 module
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 amps modular socket outlet and 15/16 amps modular switch, connection etc. as required.
Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
Supplying and fixing call bell/ buzzer suitable for single phase, 230 volts, complete as required.
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 25A modular sockets outlet and 25 A modular SP MCB, "C" curve including connections, painting etc. as required.
Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required
2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire DB TO SB
2 X 4 sq. mm + 1 X 4 sq. mm earth wire
Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator)
8 way (4 + 24), Double door
Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc.as required. (But without MCB/RCCB/Isolator)
8 way, Double door
Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole
Triple pole and neutral
Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 100 mill amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing following rating, four pole, (three phase and neutral), 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing 20 amps, 415 volts, TPN industrial type, socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 amps “C” curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required.
Supplying and fixing stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
Installation of exhaust fan in the existing opening, including making good the damage, connection, testing, commissioning etc. as required.
Upto 450 mm sweep
Supplying and installing following size of perforated painted with powder coating M.S. cable trays with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays bends with perforation not more than 17.5%,, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Tee with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
Supplying and installing following size of perforated painted with powder coating M.S. cable trays Cross Member with perforation not more than 17.5%, joined with connectors, suspended from the ceiling with M.S. suspenders including bolts & nuts, painting suspenders etc as required.
300 mm width X 50 mm depth X 1.6 mm thickness
450 mm width X 50 mm depth X 2.0 mm thickness
Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Installation of exhaust fan in the existing opening, including
Supplying, installation, testing and commissioning of recess type fitting wattage not more than 36 W panel type LED fitting,(NS 2ftx2ft) made of CRCA white powder coated housing with ABS plastic /polycarbonate diffuser. The Luminaries shall have a high efficiency diffuser with more than 80% transmittance, efficacy ≥ 100 Lumen per watt, lumens output ≥ 3600, CRI > 80 , life ≥ 50000 Hrs. (L70), CCT- of 5700 /6500k, PF.≥0.95,inbuilt surge protection not less than 2KV , including connection with 3 x 1.5 sq.mm. PVC insulated FRLS PVC sheathed copper conductor saddling/taping of cables, providing/fixing of suspention with steel fastners and G.I chain i/c dismantling if any etc. as required. Make : Havells/Crompton/Philips etc.
Supply and testing of 300 mm sweep heavy duty exhaust fan with powder coated metal body, BEE Rating not less than 03 star complete with all accessories, connections, etc. complete as required. (Make : Bajaj, Havells, Usha, Khaitan, Crompton, eq.)
Supply and testing of 18 Watt, 1'x1' size, LED downlight panel, with metal housing, anti-glare cover in front, , electonic driver, luminance efficiacy not less than 100 Lm/watt, required CCT as per site suitability/instructions of Engineer-in-charge complete with connections etc. as per the instructions of Engineer-in-charge. (Make : Bajaj, Havells, Phillips, or eq.)
Supply and testing of 20 Watt, 4 feet size, LED Batten, with polycarbonate housing, inbuilt electronic driver, luminance efficacy not less than 100 lm/watt, required CCT as per site suitability/instructions of Engineer-in-charge complete with connections etc. as per the instructions of Engineer-in-charge. (Make : Bajaj, Havells, Phillips, Crompton, or eq.)
Supply and testing of 225 mm PVC built Ventilator fresh air fan with louvers, including connections, etc. complete as required. (Make : Bajaj, Havells, Usha, Crompton, Khaitan, eq.)
Supply and testing of 1200 mm sweep ceiling fan (AC Motor) complete with down rod, capacitor and other accessories, including connections etc. complete as required.
Supply, installation, testing and commissioning of 400 mm sweep wall fan with speed and angle control including connections and wall bracket, complete as required. (Make: Crompton/Havells/Bajaj)
Supply, installation, testing and commissioning of following size of decorative lighting string of required color and ON/OFF Pattern as per direction of Engineer-in-charge on rental basis. The cost includes the charges towards supply and layng of cable for connection of light strings from power supply source as provided by CWC.
26 meter
Day-to-day operation & preventive maintenance services of Electrical installations at workplace as defined in scope of work including any or all from the set of services like technical inspection for fitness and operations of electrical installations, replacement of electrical fittings (luminiares, switches, wiring, fans etc.) as per periodicity defined in scope of work, operation of DG set and LT Breakers, checking and recording earth resistance and other periodical maintenance activities, machine operations as described in detailed scope of work and as per statutory requirements as per direction of Engineer-in-charge. The payment shall be done on quarterly basis. (Any tools and plants such as screw driver, multimeter, tester, tool kit, etc. shall be arranged by the contractor at his own cost and no such tools and plants required for carrying out operations of repair and maintainance of electrical installations works shall be provided by CWC. It will be the responsibility of the contractor to provide his manpower with PPE kits, gloves, shoes, umbrella, torch etc as required by the manpower for smooth functioning).
Repair and maintenance of plumbing infrastructure at workplace as defined in scope of work including any or all from the set of services like replacement / installation of plumbing, ceramic, sanitary fittings, and operations of motors, including other ancilliary works as mentioned under detailed scope of work and as per the instructions of Engineer-in-charge. The scope of work for plumber will also include cleaning of under ground tank/over head tank at workplace at frequency defined in scope of work. The payment shall be done on quarterly basis . (Any tools and plants such as drilling machine, cutter machine, wrench, etc shall be arranged by the contractor at his own cost and no such tools and plants required for carrying out operations of repair and maintainance of plumbing works shall be provided by CWC)
Comprehensive Annual Maintenance Contract (all inclusive maintenance contract) for smooth functioning of ceiling Cassete Air Conditioner units of following rating and type installed at RO-Panchkula as per the defined scope of work-
2.0 Ton capacity
1.5 Ton capacity
Carrying out special maintainance and repair works of civil/electrical/mechanical installations on ground of urgency/requirement at workplace defined in scope of work and as per direction of engineer in charge. The special works includes repair and maintainance services of masonary works, concrete works, steel binding and welding works, shuttering works, tile/stone cutting and laying works/aluminium door/ window partition works, glass cutting and installation works, repair/ cleaning of vertical blinds, roof and cladding sheet fixing, gutter/sewage chamber/drain/Rain water harvesting system/downtake spout pipe cleaning/unclogging and any other works directed by engineer in charge
for services of mate/ sewer man/helper/beldar/coolie or any other unskilled . The payment shall be done on satisfactorily completion of each Job .
Supply and testing of LED Flood light fixture with following wattage rating and as per technical specifications attached, including accessories for support on wall, bracket, truss, or suitable hanging arrangement upto 1 meters, and 1 meter FR PVC insulated copper conductor flexible cable of size 1.5 sq. mm, complete as per instructions of official-in-charge.
Supply and testing of LED well glass fixture with following wattage rating and as per technical specifications attached, including accessories for support on wall, bracket, truss, or suitable hanging arrangement upto 1 meters, and 1 meter FR PVC insulated copper conductor flexible cable of size 1.5 sq. mm, complete as per instructions of official-in-charge.
Supply and testing of LED street Light fixture with following wattage rating and as per technical specifications attached, including accessories for installation on existing GI pipe bracket/ Street Light pole and 1.5 meters FR PVC insulated copper conductor flexible cable of size 1.5 sq. mm, complete as per instructions of official-in-charge.
Supply and testing of LED High Bay Light fixture with following wattage rating and as per technical specifications attached, including accessories for installation on existing GI pipe bracket/ Street Light pole and 1 meter FR PVC insulated copper conductor flexible cable of size 1.5 sq. mm, complete as per instructions of official-in-charge.
Supply and testing of following rating energy efficient LED Lamp as per technical specifications and as per instructions of official-in-charge.
Supply and testing of following size and rating square shaped LED recessed downlight as per technical specification and as per instructions of official-in-charge.-
2 feet x 2 feet, 36 Watt
2 feet x 2 feet, 45 Watt
Supply and testing of following rating round shaped LED recessed/ surface ceiling lights as per technical specifications and as per instructions of official-in-charge.-
Supply and testing of following size and rating LED batten light, complete with accessories, as per technical specification and as per instructions of official-in-charge.-
2 feet, 10 Watt
4 feet, 20 Watt
4 feet, 36 Watt
Supply & testing of 18/20 Watt 4 feet LED T8 Tube light (Poly carbonate make) as per required specification and as per instructions of official-in-charge.
Supply and testing of prewired box type industrial channel fitting suitable for 1x4 feet LED T8 Tube Light, CRCA Housing and cover, copper pre-wiring, complete with T-8 LED Tube Light and all accessories and as per instructions of official-in-charge.
Supply & testing of XLPE insulated copper conductor steel armoured power cable of 1.1 KV grade confirming to IS : 7089 (part 1) 1988 or latest amendment. and as per instructions of official-in-charge.
3 X 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4.0 sq. mm
3 x 6.0 sq. mm
3 x 10 sq. mm
4 x 6.0 sq. mm
4 x 10 sq. mm
Supply & testing of XLPE insulated copper conductor unarmoured power cable of 1.1 KV grade confirming to IS :7089 (part 1) 1988 or latest amendment and as per instructions of official-in-charge.
3 X 1.5 sq. mm
3 x 2.5 sq. mm
3 x 4.0 sq. mm
3 x 6.0 sq. mm
3 x 10 sq. mm
4 x 6.0 sq. mm
4 x 10 sq. mm
Supply & testing of XLPE insulated aluminium conductor steel armoured power cable of 1.1 KV grade confirming to IS :7089 (part 1) 1988 or latest amendment and as per instructions of official-in-charge.
2 x 10 sq. mm
3 x 10 sq. mm
3 X 16 sq. mm
3 X 25 sq. mm
3 X 35 sq. mm
3 X 50 sq. mm
3 X 70 sq. mm
3 X 95 sq. mm
3 X 120 sq. mm
3 X 150 sq. mm
3 X 185 sq. mm
3 X 240 sq. mm
3 X 300 sq. mm
3.5 X 25 sq. mm
3.5 X 35 sq. mm
3.5 X 50 sq. mm
3.5 X 70 sq. mm
3.5 X 95 sq. mm
3.5 X 120 sq. mm
3.5 X 150 sq. mm
3.5 X 185 sq. mm
3.5 X 240 sq. mm
3.5 X 300 sq. mm
3.5 X 400 sq. mm
4 x 10 sq. mm
4 X 16 sq. mm
4 X 25 sq. mm
4 X 35 sq. mm
4 X 50 sq. mm
Supply & testing of XLPE insulated aluminium conductor unarmoured power cable of 1.1 KV grade confirming to IS : 7089 (part 1) 1988 or latest amendment and as per instructions of official-in-charge.
2 x 6 sq. mm
2 x 10 sq. mm
3 X 16 sq. mm
3 X 25 sq. mm
3 X 35 sq. mm
3 X 50 sq. mm
3 X 70 sq. mm
3 X 95 sq. mm
3 X 120 sq. mm
3 X 150 sq. mm
3 X 185 sq. mm
3 X 240 sq. mm
3 X 300 sq. mm
3.5 X 25 sq. mm
3.5 X 35 sq. mm
3.5 X 50 sq. mm
3.5 X 70 sq. mm
3.5 X 95 sq. mm
3.5 X 120 sq. mm
3.5 X 150 sq. mm
3.5 X 185 sq. mm
3.5 X 240 sq. mm
3.5 X 300 sq. mm
3.5 X 400 sq. mm
4 X 16 sq. mm
4 X 25 sq. mm
4 X 35 sq. mm
4 X 50 sq. mm
Installation and commissioning of LED lighting fixture of any wattage rating upto the below mentioned height including dismantling of existing fixture at same location, external or internal work, including connections, complete as per instructions of official-in-charge. (The dismantled fixture shall be handed over to the CWC Officer)
Upto 3 meters
Above 3 meters and upto 6 meters
Above 6 meters
Installation and commissioning of LED lighting fixture of any wattage rating upto the below mentioned height, including connections, complete as per instructions of official-in-charge.
Upto 3 meters
Above 3 meters and upto 6 meters
Above 6 meters
Dismantling of LED lighting fixture of any wattage rating upto the below mentioned height, including connections, complete as per instructions of official-in-charge. (The dismantled fixture shall be handed over to the CWC Officer)
Upto 3 meters
Above 3 meters and upto 6 meters
Above 6 meters
Dismantling of following type of sheet steel MCB distribution box in surface or recess irrespective of number of ways, door, etc. inclusive of dismantling of any switchgear complete as per instruction of official-in-charge.
Single pole and neutral MCB distribution box
Triple pole and neutral MCB distribution box
Supply and fixing of 20 mm dia flexible corrugated PVC conduit as required.
Supply and fixing of 20 mm dia flexible corrugated metal/GI conduit as required.
Supply & Testing of 3 core 2.5 sq.mm FRLS PVC insulated multicore Unsheathed Industrial Flexible Cable conforming to IS 694: 2010 with Flexible Bright Annealed Copper Conductor for Voltage Grade upto 1100 Volts. as per the instructions of the engineer-in-charge.
Supply & testing of 2 core 2.5 sq.mm FRLS PVC Insulated Multi core Unsheathed Industrial Flexible Cable conforming to IS 694: 2010 with Flexible Bright Annealed Copper Conductor for Voltage Grade upto 1100 Volts. as per the instructions of the engineer-in-charge.
Supply & testing of 3 core 4 sq. mm Flat Cable for submersible pump motors FRLS PVC insulated single core Unsheathed Industrial Flexible Cable conforming to IS 694: 2010 with Flexible Bright Annealed Copper Conductor for Voltage Grade upto 1100 Volts. as per the instructions of the engineer-in-charge.
Attending to breakdown calls including identification, isolation, correction of fault, followed by restoration of circuit supply complete as required as per the instructions of Officer-in-charge.
Low impact category (as decided by Officer-in-charge)
Medium Impact category (as decided by Officer-in-charge)
High Impact category (as decided by Officer-in-charge)
Lowering of carriage of High Mast Tower and raising the same including necessary fault repair/ maintenance, by operation of winch-gear assembly by manual/electro-mechanical means complete as required as per direction of official in charge
Supplying and fixing following 40 /63 Ampere rating, 240/415 V, 10 kA, "C" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required as per direction of official in charge
Triple pole
Triple pole and neutral
Supply, installation, testing & commissioning of LED Based signage board of required size, made of aluminium composite panel sheet of 3 mm thickness duly framed on 25 mm x 25 mm M.S. Square Pipe, duly computerized CNC cutting, display by using 3 mm laser cut imported acrylic sheet as per the design in bilingual, with Samsung/ Oshram make LEDs, with warranty of 1 year on LED and SMPS, with installation at site complete as per direction of official in charge
Supplying, erection and commissioning of CWC logo with CWC in Acrylic 3d letter A cast sheet of 4mm thickness with samsung/Osram module LED & back channel of ACP sheet of minimum height of 3 feet of single letter and total width 10 feet total size including logo is 10 'x 8.5 ' (H).
Comprehensive Annual Maintenance of air conditioning unit of following capacity inclusive of 04 Nos. of preventive maintenance quarterly visits (involves cleaning, servicing etc.) and any number of breakdown repair calls inclusive of all required tools, plants, consumables and spare parts as required and as per direction of official in charge
1 Tr. Window AC
1.5 Tr. Window AC
2 Tr. Window AC
1 Tr. Split AC (Non inverter)
1 Tr. Split AC (Inverter)
1.5 Tr. Split AC (Non-Inverter)
1.5 Tr. Split AC (Inverter)
2 Tr. Split AC (Inverter)
2 Tr. Split AC (Non-inverter)
2 Tr. cassette AC
Supply and Installation of 10 HP, Three Phase sewage submersible Motor Pump set with following Details-
Supply and Installation of Starter with PANEL board suitable for 10Hp submersible motor with following details. Three Phase electronic Panel with Digital voltmeter & ampere meter, phase preventer protection, thermal Overload & Electronic Dryrun protection, high/ low voltage cut off, RYB Indication, 3 pole MCb, Water level Controller, Dry run auto start Timer, etc. as per the direction of Engineer-in-charge.
Supply and fixing of SMC junction box of size 250 x 200 x 105 mm, waterproof, Fire retardant including of din bar, 6 amp single pole MCB, 4 way connector plate and making connections including installation on street light pole with MS D-Clamp with iron strip etc. complete in all respects as per direction of Officer-in-charge.
Supply and fixing of SMC junction box of size 140 x 140 x 95 mm, waterproof, Fire retardant including of 4 way connector plate and making connections including installation on street light pole with MS D-Clamp with iron strip etc. complete in all respects as per direction of Officer-in-charge.
Testing of earth pit resistance test using calibrated ground resistance meter and submission of report, complete as per instructions of Officer-in-charge.
Supplying, Installation, Testing and commissioning of dust, damp and vermin proof wall mounted, outdoor type factory built sheet steel enclosed modular bolted construction extendable type Main Distribution Panel, suitable for operation on 415 ±10% volts, 50 Hz AC 3 phase 4 wire supply system fabricated out of suitable sized square tubular section and covered with CRCA sheet steel of 1.2mm thick for frame work and 1.2mm covers , 1.6mm thick for gland plates i/c cleaning & finishing complete with 7 tank process for powder coating in approved shade, having extensible type TPN Aluminium bus bars of high conductivity, SMC bus bar supports, fabrication shall be done in transportable sections, entire panel shall have a common G.I. earth bus bar to switch gears with required size of Alum. bus bars and inter-connection with solid copper conductor wires / aluminium strips, neutral links, including control wiring with 1.5 / 2.5sqmm. PVC insulated FRLS copper conductor Single Core cable, cable alleys, cable gland plates in two half, etc. necessary metering protections & indications and mounted with the following switch gears as per drawing and technical specifications etc. complete as required. The Quantities of components/rating may be changed as per the direction of Engineer in Charge The panel should be compatible as per local DISCOM requirements.
Supply, installation, testing and commissioning of following height high mast tower excluding excavation but including the following - a) Supply of stated height high mast shaft in two/three sections suitable for 47 m/sec wind speed, with head frame, winch mounting bracket, luminaires carriage suitable to install stated number of luminaires in symmetrical arrangement. b) Supply of raising lowering system comprising double drum winch, 6 mm diameter SS wire rope, trailing cable, connector, integral power tool motor, manual handle, junction box, lightening finial. c) Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plate and common template. d) Supply of outdoor stand mounted feeder pillar with 32 A TPN MCB incommer, single dial time switch, 25 A TP Contactor for the automatic switching of luminaires, power tool control with 02 Nos. 9 A contactors and raise lower push button, incomming and outgoing terminals for lights and motor as required. e) Supply of LED Type single dome aviation obstruction light. Stand must be double door made up of 2 SWG sheet and powder coated with 7 tank technique. f) Erection of the high mast with the help of suitable tools and plants, wiring of luminaires with all wiring materials like PVC insulated PVC sheathed flexible cable of suitable copper conductor cores of 1.5 sq. mm, lugs, MCB and all labour. g) Installation of the mast feeder pillar by grouting the stand in concrete.
Description
E NIT_CWC/RO_ PKL/Engg/AMC/ZONE-5/26-27/09
Execution of Miscellaneous Repair /Maintenance, upgradation and Construction works in Zone 5 – a cluster of RO Building Panchkula On Annual rate Contract basis
Description of Work
Price Schedule: • Items mentioned at Sub Schedule A(1), • Items based on DSR 2023 for civil works, • Non-Scheduled Market rate Items of Civil work.
E NIT_CWC/RO_ PKL/Engg/AMC/ZONE-5/26-27/09
Execution of Miscellaneous Repair /Maintenance, upgradation and Construction works in Zone 5 – a cluster of RO Building Panchkula On Annual rate Contract basis
Description of Work
Price Schedule: • Items mentioned at Sub Schedule A(II), • Items based on DSR (E &M) 2025 for Electrical works • Non-Scheduled Market rate Items of E&M work.
E NIT_CWC/RO_ PKL/Engg/AMC/ZONE-5/26-27/09
Execution of Miscellaneous Repair /Maintenance, upgradation and Construction works in Zone 5 – a cluster of RO Building Panchkula On Annual rate Contract basis
Description of Work
Price Schedule: • Items mentioned at Sub Schedule A. (III) •Items for General Maintenance Works & Services consisting Horticulture works and House Keeping Services.
E NIT_CWC/RO_ PKL/Engg/AMC/ZONE-5/26-27/09
Execution of Miscellaneous Repair /Maintenance, upgradation and Construction works in Zone 5 – a cluster of RO Building Panchkula On Annual rate Contract basis
Total of Sub schedule A. (I)
Total of Sub schedule A. (II)
Total of Sub schedule A. (III)
Total of all Sub Schedules (I) + (II) + (III) {In Figures}
Total of all Sub Schedules (I) + (II) + (III) {In Words}
Documents to be submitted by the bidder alongwith their bid
Earnest Money Deposit (EMD): only through e-payment gateway of e-procurement system.
Proof of tender cost paid only through e-payment gateway of e-procurement system
Experience Certificate: For Executing Works of Similar Nature as per tender eligibility criteria (Annexure-A)
Chartered Accountant’s Certificate: For tenderer’s Annual Turnover
Annual Turnover supported with complete Audited Balance Sheet and Statement of Profit & Loss for financial years preceding three financial years (as per Annexure A)
Affidavit on Stamp Paper: Duly attested by the Notary as per Annexure IV
Bidder must have Office, on the latest due date of tender submission in any District of The State where Central warehouse ie site of work, is located ie Bidder must have office in Haryana For this purpose, valid GST number shall be considered as proof of office address. Bidder would be required to submit the proof of office address at the time ofcontract signing.
Eligibility declaration form as per NIT-clause 3 and ITB-clause 3.2 under form -E of this PQ Performa
Power of Attorney* AND/ OR Board Resolution in favour of signatory(ies) duly attested by the Notary as per ANNEXURE III
Integrity Pact as per ANNEXURE V duly signed by Tenderer. (for contracts having estimated value of Rs. 3 (three) crore or more)
Certificate of Net Worth duly certified by the Chartered Accountant as per ANNEXURE I based on the accounts for the latest financial year
GST registration Certificate (as applicable).
Permanent Account Number (PAN) Card.
PF Registration certificate.
a) Affidavit for sole proprietary firm as per ANNEXURE II or b) Copy of Partnership deed of a partnership firm or c) Certificate of Incorporation, Memorandum of Association & Articles of Association for company alongwith resolution of the company for authorizing the Director/ authorised signatory to sign the document.
Certificate of Registration with Registrars of Company (ROC).in case of Ltd. / Pvt. Ltd. company/PSU, if required.
Declaration of near relative as per Annexure-VI.
Declaration of work in hand(in progress) as per ANNEXURE-VII.
Valid Registration Certificates of Contractor or Proof of having worked/working with CPWD / Railways / MES / State PWD / Other Govt. Organization / Govt. Sector Construction Agency / Public Sector Undertaking & their Subsidiary
List of Permanent Technical Persons
List of Plant & Machinery.
Pre-Qualifying (PQ) Proforma.
Bank Details (Account No., Bank Name, MICR No., RTGS No. & copy of Cancelled Cheque)
Description
Name of the Bidder,
Address, Organization ID, Tel./Fax No. & E-mail address of Bidder
Type of constituent (Organization) (Proprietorship / Partnership / Private Limited / Limited)
Attested copy of organization Details (Proprietorship / Partnership / Private Limited / Limited)
Name of the person holding the power of attorney for this Bid
Contact details of person holding the power of attorney Mobile Number Email id.
Attested Copy of Power of Attorney details to sign the Tender Document
Earnest Money Deposit (EMD) of Rs. 3,27,316 /- : Only through e-payment Gateway
Cost of Tender Documents of Rs.0
PF Registration code
GST Registration code
PAN No. of the Bidder
Contractor Registration enlistment with CPWD/ MES/ Railway etc if any
Financial Eligibility Criteria:
The Sum(Arithmetic sum) of tenderer’s turnover: revenue(income) from operations for the last three financial years Should be of value not less than ₹ 368.23 Lakh (225% of Estimated Cost put on Tender). The information shall be supported by audited Balance Sheets and Profit & Loss Statements of specified period. Incase Balance Sheet and Statement of Profit/Loss for the immediately preceding financial year have not been prepared / audited; the account for one more preceding financial year can be submitted. Incase,Bidder does not Submit Audited balance sheet and P&L accounts for a particular year (among previous three years as mentioned above), turn over for that particular year will beconsidered ‘0’ (zero) for calculating arithmetic sum of previoust hree years. {Please see Eligibility criteria as per Annexure-A in Tender document}
Chartered Accountant’s Certificate for Annual financial turnover/revenue (income) from operations of specified preceding three years
Annual Financial Turnover/Revenue (Income) from operations (as per P&L Account)
Total Turn Over- RS…….
Total Turn Over- RS…….
Total Turn Over- RS…….
Total Turn Over- RS…….
Experience w.r.t. Similar Nature of Work :
Name of the works completed and presented against the criteria:
Work order/ contract agreement ref number and date
Name of client issuing the work order and completion certificate
Completion certificate -ref number and date
Total value of work completed (Rs.)
Stipulated date of completion
Actual date of completion
Amount / period of delay for which Liquidity damage levied by client (if any)
Work order/ contract agreement ref number and date
Name of client issuing the work order and completion certificate
Completion certificate -ref number and date
Total value of work completed (Rs.)
Stipulated date of completion
Actual date of completion
Amount / period of delay for which Liquidity damage levied by client (if any)
Work order/ contract agreement ref number and date
Name of client issuing the work order and completion certificate
Completion certificate -ref number and date
Total value of work completed (Rs.)
Stipulated date of completion
Actual date of completion
Amount / period of delay for which Liquidity damage levied by client (if any)
Bidder Office in the State
Bidder must have Office, on the latest due date of tender submission in any District of The State where Central warehouse i.e. site of work, is located ie Bidder must have office Haryana. For this purpose, valid GST number shall be considered as proof of office address. Bidder would be required to submit the proof of office address at the time of contract signing.
GST Number
Eligibility declaration form as per NIT-clause 3 and ITB-clause 3.2 under form -E of this PQ Performa
stage.html
html • 0.02 MB
tech_eval.pdf
cancelled_1.pdf
pdf • 0.79 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 6.22 MB
NITPANCHKULA.pdf
Tender Documents • 6.20 MB
Price_Bid_Zone_5.xls
Other Document • 0.24 MB
Techbidzone5.xls
Other Document • 0.06 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .