Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.9 LAccepted-AOC VIVEKA HOME 207 D UDANGUDI ROAD TISAYANVILLAI 627657 TIRUNELVELI | TISAYANVILLAI | TIRUNELVELI | TAMIL NADU | 627657 | L1 | Accepted-AOC AOC | |
| 2 | L2₹29.8 L+₹38,285 (1.30%)Rejected-Finance ANGALAMMAN KOVIL STREET ULIYANALLORE POST PANAPAKKAM VIA ARAKKONAM TK VELLORE DIST TN 631 052 | ARAKKONAM | VELLORE | TAMIL NADU | 631052 | L2 | Rejected-Finance L1 being accepted | |
| 3 | L3₹31.1 L+₹1.8 L (5.99%)Rejected-Finance CHENNAI | L3 | Rejected-Finance L1 being accepted | |
| 4 | L4₹32.5 L+₹3.2 L (10.8%)Rejected-Finance 1 28 NORTH STREET SOUTH VILAYANARAYANAM NANGUNERI TALUK TIRUNELVELI DIST 627 118 | TIRUNELVELI | TIRUNELVELI | TAMIL NADU | 627118 | L4 | Rejected-Finance L1 being accepted |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
3 Sept 2020, 6:00 pmClosed
GE TIRUNELVELI
GE TIRUNELVELI INS KATTABOMMAN NAVAL BASE POST VIJAYANARAYANAM TIRUNELVELI
REPAIRS / MAINTENANCE OF LT PANELS, UG CABLES AND ITS CONNECTED ACCESSORIES AT TECHNICAL AREA UNDER GE TIRUNELVELI
2020_MES_367709_1
GE/TVL/8120
Open Tender
Miscellaneous Works
Item Rate
180 days
Vijayanarayanam
As per NIT/Tender documents
8 documents required · 8 mandatory
₹500
GE TIRUNELVELI
₹60,000
Yes
26 Sept 2020
8 Aug 2020
5 Sept 2020
8 Aug 2020
3 Sept 2020
22 Aug 2020
8 Aug 2020 - 18 Aug 2020
Amount
SCHEDULE 'A' (REPAIR/MAINTENANCE OF LT PANELS & UG CABLES AND CONNECTED WORKS)
Excavation in trenches n.exc 1.5 M wide and n. exc 1.5 M depth and getting out in hard/dense soil for removing / taking out burnt cables complete all specified and as directed.
Returning, filling in trenches including spreading, leveling, watering and in layers n.exc 25cms thick without damaging pipes/special fittings as in any type of soil complete all as specified and directed.
Removing excavated materials to a distance n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed.
Supply and spread river sand in trenches for cable cushioning complete all as specified and directed. Note:- (Punned thickness only will be measured)
Supply and lay burnt bricks of old size sub-class B for cable protection all as directed & as specified.
Material and labour for fixing the new moulded case circuit breakers (MCCB) in the existing feeder pillar box with new bolts and nuts including connecting the incoming and out going cables by using suitable cable glands and jumpers/cable with the bus bar including Taking down burnt out MCCB, of following capacity in the existing feeder Pillar box complete as specified and directed.
(a) MCCB 4 Pole 800 Amps 50 KA. Make:- L&T Cat No-CM96111OOOOX1 or equivalent in LEGRAND/ ABB/ SIEMENS/SCHNEDER/C&S/HAVELLS
(b) MCCB 4 Pole 630 Amps 50 KA. Make:- L&T Cat No-CM93008OOOOX1 or equivalent in LEGRAND/ ABB/SIEMENS/SCHNEDER/C&S/HAVELLS
(c) MCCB 4 Pole 400 Amps 36 KA. Make:- L&T Cat No-CM93003OOOOX1 or equivalent in LEGRAND/ ABB/SIEMENS/SCHNEDER/C&S/HAVELLS
(d) MCCB 4 Pole 250 Amps 36 KA. Make:- L&T Cat No-CM93003OOOOX1 or equivalent in LEGRAND/ABB/SIEMENS/SCHNEDER/C&S/HAVELLS
(e) MCCB 4 Pole 200 Amps 36 KA. Make:- L&T Cat No-CM93003OOOOX1 or equivalent in LEGRAND/ ABB/SIEMENS/SCHNEDER/C&S/HAVELLS
(f) MCCB 4 Pole 160 Amps 25 KA. Make:- L&T Cat No-CM90642OOMO or equivalent in LEGRAND/ ABB/SIEMENS/SCHNEDER/C&S/HAVELLS
(g) MCCB 4 Pole 125 Amps 25 KA. Make:- L&T Cat No-CM90642OOMO or equivalent in LEGRAND/ ABB/SIEMENS/SCHNEDER/C&S/HAVELLS
(h) MCCB 4 Pole 100 Amps 25 KA. Make:- L&T Cat No-CM91712OOKOOG or equivalent in LEGRAND/ ABB/SIEMENS/SCHNEDER/C&S/HAVELLS
Material and labour for fixing the new Miniture circuit breakers (MCB) in the existing feeder pillar box with new bolts and nuts including connecting the incoming and out going cables by using suitable cable glands and jumpers/cable with the bus bar including Taking down burnt out MCCB, of following capacity in the existing feeder Pillar box complete as specified and directed.
(a) MCB 4P, 32 Amp, 10 KA, 'C' Series. Make:- L&T Cat No-BB40320C or equivalent in LEGRAND/ABB/ SIEMENS /SCHNEDER/C&S/HAVELLS
(b) MCB 4P, 63 Amp, 10 KA, 'C' Series. Make:- L&T Cat No-BB40630C or equivalent in LEGRAND/ABB/SIEMENS/SCHNEDER/C&S/HAVELLS
(c) MCB TP, 32 Amp, 10 KA, 'C' Series. Make:- L&T Cat No-BB30320C or equivalent in LEGRAND/ABB/ SIEMENS/SCHNEDER/C&S/HAVELLS
(d) MCB 4P, 80 Amp, 15 KA, 'C' Series. Make:- L&T Cat No-AU15S40803Cor equivalent in LEGRAND/ABB/ SIEMENS/SCHNEDER/C&S/HAVELLS
(e) MCB 4P, 40 Amp, 10 KA, 'C' Series. Make:- L&T Cat No-BB40400C or equivalent in LEGRAND/ABB/ SIEMENS/SCHNEDER/C&S/HAVELLS
(f) MCB DP, 40 Amp, 10 KA, 'C' Series. Make:- L&T Cat No-BB20400C or equivalent in LEGRAND/ABB/ SIEMENS/SCHNEDER/C&S/HAVELLS
(g) MCB DP, 32 Amp, 10 KA, 'C' Series. Make:- L&T Cat No-BB20320C or equivalent in LEGRAND/ABB/ SIEMENS/SCHNEDER/C&S/HAVELLS
(h) MCB 4P, 16 Amp, 10 KA, 'C' Series. Make:- L&T Cat No-BB40160C or equivalent in LEGRAND/ABB/ SIEMENS/SCHNEDER/C&S/HAVELLS
(j) MCB SP, 6-32 Amp, 10 KA, 'C' Series. Make:- L&T or equivalent in LEGRAND/ABB/SIEMENS/ SCHNEDER/ C&S/HAVELLS
Supply, installation, and testing of new energy meter electronic type 3 phase of accuracy class 0.5, input voltage measurment 50-520 Volt, AC, flush mounting type,including taking down old unserviceable electro mechanical meter of any type complete all as specified and directed by Engr-in-Charge. Make:- Schneider Cat no 30002572 or equivalent in SIEMENS/HPL INDIA/L&T/INDO ASIA
Supply, installation, and testing of new Voltmeter, 3 phase of accuracy class 0.5, input voltage measurment 50-520 Volt, AC, flush mounting type including taking down old unserviceable Voltmeter of any type complete all as specified and directed by Engr-in-Charge. Make:-Schneider Cat no 30002965 or equivalent in BCH/ Siemens.
Supply, installation, and testing of new Ammeter 3 phase, of accuracy class 0.5, AC, flush mounting type including taking down old unserviceable Ammeter of any type complete all as specified and directed by Engr-in-Charge. Make:-Schneider Cat no 30002964 or equivalent in BCH/ Siemens.
M & L for opening the cover of ACB 4000/3200/1600/800 A, 440V, 4P and servicing/ of fixed and moving contacts, repair and replacement of fixed copper terminal/contacts (male and female ),insulation tubes including other connected items to functional of panel board , lamp indicators ,meters, tripping coil , caliberation of over load protection relay , time delay relay /earth fault relay etc . Clening the fixed and moving contact inside the ACBs properly , checking of EDO/MDO mechanism, servicing and graesing all movable machanisum , replacement of defective fuses , wiring and reassembling and testing and serviceability check complete all as per the direction of Engineer in Charge and manufacturer instructions. Note : Servicing will be done by authorised dealer only
M & L for servicing of 30 KVA UPS system, checking battery terminal for tight or replacement, connection cable including other connected items to functional of panel board , lamp indicators ,meters, lubricating battery terminal, replacement of defective fuses , wiring and reassembling and testing and serviceability check complete all as per the direction of Engineer in Charge and manufacturer instructions. Note : Servicing will be done by authorised dealer only
M & L for taking down old unserviceable battery and replacement with new sealed maintenance free lead acid battery12 V, 42 AH including connected wire and clamps for 30 KVA UPS system complete all as specified and directed by Engr-in-Charge. Make: Exide Model EP-42-12 or equivalent Amaron
S & F wall mounted flex sign board size not less than 0.8x0.6mtr made out of high quality GI sheet thickness not less than 2mm and suitable size of Aluminium bedding with flex for marking of schematic diagram of external electric supply scheme with suitable fixing arrangement as directed by Engr-in-Charge and including 2x10W batten type LED fitting and wiring inside the board with suitable size of cables and the board fixed on wall with suitable size of GI nut bolts complete including taking down old existing, all as specified and directed by Engr-in-Charge.
Supply, laying and testing LT under ground cable 1100 volts grade PVC /XLPE insulated and sheathed armoured multistranded heavy duty electric power cable with aluminium conductor 2 core 10 Sqmm, laid in trenches/ duct / walls including cable gland on both termination where necessary including laying, connecting to various switches in panel board,etc, testing and commissioning etc complete all as specified and directed. NOTE: Earth work excavation shall be measured and paid separately.
Description all as per item No 16 but 4 core 10 Sqmm size complete all specified and as directed.
Description all as per item No 16 but 4 core 25 Sqmm size complete all specified and as directed.
Description all as per item No 16 but 3.5 core 35 Sqmm size complete all specified and as directed.
Description all as per item No 16 but 3.5 core 50 Sqmm size complete all specified and as directed.
Description all as per item No 16 but 3.5 core 70 Sqmm size complete all specified and as directed.
Description all as per item No 16 but 3.5 core 95 Sqmm size complete all specified and as directed.
Description all as per item No 16 but 3.5 core 120 Sqmm size complete all specified and as directed.
Description all as per item No 16 but 3.5 core 150 Sqmm size complete all specified and as directed.
Description all as per item No 16 but 3.5 core 185 Sqmm size complete all specified and as directed.
Description all as per item No 16 but 3.5 core 240 Sqmm size complete all specified and as directed.
Description all as per item No 16 but 3.5 core 300 Sqmm size complete all specified and as directed.
M & L for servicing of PLC panel by checking of incoming and outgoing control cable, checking of control supply, checking of UPS backup supply, including repair/replacement of spere parts such as DP 40 A MCB, 230V TP 9A contactor, 24V 4C/O Relay hooters including all necessary accessories including other connected items to functional of panel board , lamp indicators ,meters, replacement of defective fuses , wiring and testing and serviceability check complete all as per the direction of Engineer in Charge and manufacturer instructions. Note : Servicing will be done by authorised dealer only
Dismantling the old unserviceable LT Panel Board and Supply Fabricate, install, connect, test and commission Outdoor type dust & Vermin proof LT electrical panel board, 1100 volts, 50 Hz AC supply, fully compartmentalised for cable chamber and busbar chambers with copper bus bar 4wire 3phase 400Amps with adequate space made out of 3.15 mm thick CRCA sheet steel for load bearing like all over body, front and back cover with hinges and aldrops with DC locks and one seven lever Navtal lock etc complete with 1 mm thick FRP coated all over the external surfaces and 3.15 mm thick MS Sheet for non load bearing and portions, complete with one coat of red oxide primer , two coats of powder coating weather proof synthetic enamel paint including suitable angle iron/ flat iron frame work/ supports bottom 50x50x6 mm MS channel as base and chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated and FRLS copper conductor complete mounted on PCC pillars foundation, cable connection using new lugs complete with danger notice all as specified and comprising of the followings:- Make:- L&T/Legrand/Standard any CPRI approved makes
Item No. 29 Contd............. Incoming (a) MCCB (Microprocessor release type) 4 Pole 250 Amp, 50 Hz, 415 V with rupturing capacity 35 KA. (01 No) Outgoing (b) MCCB 4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA. (03 Nos) (c) MCCB 4 Pole 40 Amp, 50 Hz, 415 V with rupturing capacity 25 KA. (03 Nos) (d) MCB DP Pole 40 Amp, 50 Hz, 240 V with rupturing capacity 10 KA. (03 Nos) (e) LED Indicating lamp RYB - 01 Set. (f) Digital Voltmeter(0-500volt) - 01 Nos (g) Digital ammeter with suitable CT's-01 Set
Dismantling the old unserviceable LT Panel Board and Supply Fabricate, install, connect, test and commission Outdoor type dust & Vermin proof LT electrical panel board, 1100 volts, 50 Hz AC supply, fully compartmentalised for cable chamber and busbar chambers with copper bus bar 4wire 3phase 160Amps with adequate space made out of 3.15 mm thick CRCA sheet steel for load bearing like all over body, front and back cover with hinges and aldrops with DC locks and one seven lever Navtal lock etc complete with 1 mm thick FRP coated all over the external surfaces and 3.15 mm thick MS Sheet for non load bearing and portions, complete with one coat of red oxide primer , two coats of powder coating weather proof synthetic enamel paint including suitable angle iron/ flat iron frame work/ supports bottom 50x50x6 mm MS channel as base and chamber for metering equipment complete suitable for mounting following switch gear items internally connected with suitable capacity aluminium strip/ rods insulated and FRLS copper conductor complete mounted on PCC pillars foundation, cable connection using new lugs complete with danger notice all as specified and comprising of the followings:- Make:- L&T/Legrand/Standard any CPRI approved makes
Item No. 30 Contd............. Incoming (a) MCCB TPN 4 Pole 100 Amp, 50 Hz, 415 V with rupturing capacity 36 KA. (01 No) Outgoing (b) MCCB FP 4 Pole 63 Amp, 50 Hz, 415 V with rupturing capacity 25 KA. (03 Nos) (c) MCCB FP4 Pole 32 Amp, 50 Hz, 415 V with rupturing capacity 25 KA. (03 Nos) (d) LED Indicating lamp RYB - 01 Set. (e) Digital Voltmeter(0-500volt) - 01 Nos (f) Digital ammeter with suitable CT's-01 Set
Supply and fix in repairs LED lamp fitting with 1 x 45 Watts LED made in pressure die cast aluminium housing with IP 66 protection and all other accessories complete and Disconnecting and taking down the unserviceable rusted street light fittings from the steel tubular poles complete all as specified and as directed. Make : Bajaj Cat Part No BRTFG 45W LED I or equivalent in Philips/CG/C&S.
Supply and fix 40 mm dia light grade GI tube bracket of length 1.5 metre bend to required shape including MS clamp made out of 30 mm x 6 mm MS flat iron and fix on steel tubular poles with necessary GI bolts, nuts and washers - 2 sets for each fittings including taking down the existing GI tube bracket complete set all as specified and directed.
Supply and fixing in repair of PVC insulated unsheathed cables of size 1.5sqmm 2 core multi-stranded Copper conductor wire from street light tojunction box as per existing including taking down of old complete all as specified and as directed.
Supply and fixing Rigid non metalic PVC conduit, ISI marked medium grade with outer dia of 20mm to be fix along with steel tubular pole with minimum 4 Nos of clamps with nut bolts complete all as specified and directed by Engr-in-Charge.
Supply and Fix in repair junction boxes IP 66 protected made out of poly carbonate material for out door installations of size 255x355x122mm with 100 Amp Aluminium Busbar 4 Pole including incoming, outgoing cable connection arrangements with colour code insulation sleeves all as specified and directed by Engr-in-Charge. Make:- Hensel Cat no KF5000C or equivalent in Sintex/C&S
JR ENTERPRISES
VVM CONSTRUCTIONS
sri manikandan enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .