GEMC-511687741303519
Awarded to shubh enterprises
₹53,890
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Digital Lux Meter NM-101A | NEUMAN & MILLER & NM-101A | - | 10 NOS | ₹5,389 | 53,890 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹53,890Qualified Make: N and M
Model: NEUMAN & MILLER & NM-101A 00 ASHOK NAGAR GURSAHAIGANJ KANNAUJ UTTAR PRADESH 209722 | KANNAUJ | UTTAR PRADESH | 209722 | Make: N and M
Model: NEUMAN & MILLER & NM-101A | L1 | Qualified | |
| 2 | L2₹54,240+₹350 (0.65%)Qualified Make: N and M
Model: NEUMAN & MILLER & NM-101A 5A 18 ROOM NO A GROUND FLOOR FRONT SIDE TILAK NAGAR DELHI DELHI 110018 UDYAM DL 11 0012098 07AAKFG1385Q1ZR B R M MII STATUS AS VERIFIED | WEST DELHI | DELHI | 110018 | Make: N and M
Model: NEUMAN & MILLER & NM-101A | L2 | Qualified | |
| 3 | Disqualified Make: MECO
Model: MECO 101B+ A 8 MANGALDIP APPARTMENT SAIJPUR BOGHA NARODA ROAD AHMEDABAD GUJARAT 382345 | AHMADABAD | GUJARAT | 382345 | Make: MECO
Model: MECO 101B+ | - | Disqualified | |
| 4 | Disqualified Make: FLUKE
Model: FLUKE 101 8 A MANGALDEEP APPARTMENT OPP PRJAPTI COLONY B S GAYATRI SOC SAIJPUR BOGHA SAIJPUR BOGHA AHMEDABAD | Make: FLUKE
Model: FLUKE 101 | - | Disqualified | |
| 5 | Disqualified Make: NA
Model: DIGITAL MULTI METER 21 C INDUSTRIAL ESTATE OPP POLICE LINE GANGA NAGAR | Make: NA
Model: DIGITAL MULTI METER | - | Disqualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
4 Oct 2018, 11:00 amClosed
Digital Multimeter ( 10 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held
Benchtop Display (Digits) 3.5 3.5
4.5
6.5 Measurement Type Average Average
True RMS Counts 4000 4000
6000
50000
200000 (or higher) MEASUREMENTS DC Voltage Range 600 600
1000 DC Voltage Accuracy 0.05 0.005
0.05
0.1
0.5
1 DC Voltage resolution 0.01 0.001
0.01
1
10
100 AC Voltage Range 600 600
1000 AC Voltage Accuracy 0.1 0.08
1 AC Voltage resolution 0.01 0.001
100 DC Current Range 3 3
10 DC Current Accuracy 0.05 0.005
1.5 1/5 DC Current resolution 0.001 0.001
100 AC Current Range 3 3
10 AC Current Accuracy 1 0.5
1.5 AC Current resolution 0.01 0.001
100 Resistance Range 40 40
50
60
100
500 Resistance Accuracy 1 0.08
1.5
2
2.5
3
3.5 Resistance resolution 0.001 0.001
100 Capacitance Range ( Micro farad ) 1 to 200 1 to 100
1 to 200
.01 to 1000
NA Capacitance Accuracy ( % ) 1.5 1.5
3.5
5
NA Capacitance resolution ( nF ) 0.001 0.001
NA Frequency Range ( KHz ) 50 50
200
300
NA Frequency Accuracy ( % ) 0.1 0.1
NA Frequency resolution ( Hz ) 0.001 0.001
NA Temperature Range ( Degree C ) -40 to 400 -40 to 400
50 to 1000
NA Temperature Accuracy ( % ) 1.5 1.5
NA Temperature resolution ( Degree C ) 0.001 0.001
NA OTHER FEATURES Continuity test and Diode test Available * Data logging Available * If Data Logging Feature is Available
Internal Memory min. 5000 points/200 readings * Computer Interface along with software Available * Dimensions ( mm X mm X mm ) 82 x 55 x 7 * Weight 300 * Other Features HTC LX-101A * SAFETY Safety Rating Category II 600 V of IEC 61010. Category II 600 V of IEC 61010.
Category II 1000 V of IEC 61010.
2/5 Category III 600 V of IEC 61010.
Category III 1000 V of IEC 61010.
Category IV 600 V of IEC 61010
Category IV 1000 V of IEC 61010 Safety Certification CE * POWER REQUIREMENTS Power Requirements 230 V +/-10% AC
50 Hz +/- 3% through Adaptor * if Battery Operated
then Type of Battery Rechargeable * if rechargeable
then chemistry of the battery NA * if Non-rechargeable
then size of the battery cell 9-V rectangular battery * number of non- rechargeable the battery/cell 1 * Voltage of rechargeable Battery 9 * capacity of rechargeable battery(milli Ampere Hour) 0 * Suitable charger adaptor provided YES * ACCESSORIES Standard Accessories Supplied with the Equipment Standard * WARRANTY Warranty 1 1
5 OPERATING CONDITION Minimum Operating Temperature 20 * Maximum Operating Condition 70 * Operating Humidity (RH) 95 * TEST REPORT DETAILS The equipment supplied with calibration certificate YES * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true * 3/5 conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH true * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification false * Test Report Number and date for the specification test Na * Name and address of the Lab for the specification test Na * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ashok Kumar Bastia 759102
MAHANADI COALFIELDS LIMITED
AT/PO: Deulbera Colliery
Dist: Angul-759102 10 30
647949
GEM/2018/B/91945
GeM Contract
digital multimeter
GeM Contract
30 days
Odisha; Anugul
PRODUCT
Awarded to shubh enterprises
₹53,890
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| Digital Lux Meter NM-101A | NEUMAN & MILLER & NM-101A | - | 10 NOS | ₹5,389 | 53,890 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Digital Multimeter ( 10 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values FEATURES Type Hand Held Hand Held | - | - | - |
| Benchtop Display (Digits) 3.5 3.5 | - | - | - |
| 4.5 | - | - | - |
| 6.5 Measurement Type Average Average | - | - | - |
| True RMS Counts 4000 4000 | - | - | - |
| 6000 | - | - | - |
| 50000 | - | - | - |
| 200000 (or higher) MEASUREMENTS DC Voltage Range 600 600 | - | - | - |
| 1000 DC Voltage Accuracy 0.05 0.005 | - | - | - |
| 0.05 | - | - | - |
| 0.1 | - | - | - |
| 0.5 | - | - | - |
| 1 DC Voltage resolution 0.01 0.001 | - | - | - |
| 0.01 | - | - | - |
| 1 | - | - | - |
| 10 | - | - | - |
| 100 AC Voltage Range 600 600 | - | - | - |
| 1000 AC Voltage Accuracy 0.1 0.08 | - | - | - |
| 1 AC Voltage resolution 0.01 0.001 | - | - | - |
| 100 DC Current Range 3 3 | - | - | - |
| 10 DC Current Accuracy 0.05 0.005 | - | - | - |
| 1.5 1/5 DC Current resolution 0.001 0.001 | - | - | - |
| 100 AC Current Range 3 3 | - | - | - |
| 10 AC Current Accuracy 1 0.5 | - | - | - |
| 1.5 AC Current resolution 0.01 0.001 | - | - | - |
| 100 Resistance Range 40 40 | - | - | - |
| 50 | - | - | - |
| 60 | - | - | - |
| 100 | - | - | - |
| 500 Resistance Accuracy 1 0.08 | - | - | - |
| 1.5 | - | - | - |
| 2 | - | - | - |
| 2.5 | - | - | - |
| 3 | - | - | - |
| 3.5 Resistance resolution 0.001 0.001 | - | - | - |
| 100 Capacitance Range ( Micro farad ) 1 to 200 1 to 100 | - | - | - |
| 1 to 200 | - | - | - |
| .01 to 1000 | - | - | - |
| NA Capacitance Accuracy ( % ) 1.5 1.5 | - | - | - |
| 3.5 | - | - | - |
| 5 | - | - | - |
| NA Capacitance resolution ( nF ) 0.001 0.001 | - | - | - |
| NA Frequency Range ( KHz ) 50 50 | - | - | - |
| 200 | - | - | - |
| 300 | - | - | - |
| NA Frequency Accuracy ( % ) 0.1 0.1 | - | - | - |
| NA Frequency resolution ( Hz ) 0.001 0.001 | - | - | - |
| NA Temperature Range ( Degree C ) -40 to 400 -40 to 400 | - | - | - |
| 50 to 1000 | - | - | - |
| NA Temperature Accuracy ( % ) 1.5 1.5 | - | - | - |
| NA Temperature resolution ( Degree C ) 0.001 0.001 | - | - | - |
| NA OTHER FEATURES Continuity test and Diode test Available * Data logging Available * If Data Logging Feature is Available | - | - | - |
| Internal Memory min. 5000 points/200 readings * Computer Interface along with software Available * Dimensions ( mm X mm X mm ) 82 x 55 x 7 * Weight 300 * Other Features HTC LX-101A * SAFETY Safety Rating Category II 600 V of IEC 61010. Category II 600 V of IEC 61010. | - | - | - |
| Category II 1000 V of IEC 61010. | - | - | - |
| 2/5 Category III 600 V of IEC 61010. | - | - | - |
| Category III 1000 V of IEC 61010. | - | - | - |
| Category IV 600 V of IEC 61010 | - | - | - |
| Category IV 1000 V of IEC 61010 Safety Certification CE * POWER REQUIREMENTS Power Requirements 230 V +/-10% AC | - | - | - |
| 50 Hz +/- 3% through Adaptor * if Battery Operated | - | - | - |
| then Type of Battery Rechargeable * if rechargeable | - | - | - |
| then chemistry of the battery NA * if Non-rechargeable | - | - | - |
| then size of the battery cell 9-V rectangular battery * number of non- rechargeable the battery/cell 1 * Voltage of rechargeable Battery 9 * capacity of rechargeable battery(milli Ampere Hour) 0 * Suitable charger adaptor provided YES * ACCESSORIES Standard Accessories Supplied with the Equipment Standard * WARRANTY Warranty 1 1 | - | - | - |
| 5 OPERATING CONDITION Minimum Operating Temperature 20 * Maximum Operating Condition 70 * Operating Humidity (RH) 95 * TEST REPORT DETAILS The equipment supplied with calibration certificate YES * conformity to Dry Heat for 16 hrs at a specified maximum temp in accordance with IS:900 0/part-3/section-5/1977 latest true * 3/5 conformity to Cold Test for 4 hrs at a specified minimum temp in accordance with IS:900 0/part-2/section-4/1977 latest true * conformity to Damp Heat (Cyclic)Test for 2 Cycles of 24 hrs each at a temp of 40 degree C & 95% RH true * Availability of Test Reports from Central Govt/NABL/ILAC approved accredited lab to prove conformity to the specification false * Test Report Number and date for the specification test Na * Name and address of the Lab for the specification test Na * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Ashok Kumar Bastia 759102 | - | - | - |
| MAHANADI COALFIELDS LIMITED | - | - | - |
| AT/PO: Deulbera Colliery | - | - | - |
| Dist: Angul-759102 10 30 | - | - | - |
Exempted
6 Dec 2018
5 Oct 2018
contract_GEMC-511687741303519.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_647949.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .