Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.0 CrAccepted-AOC | ₹24.0 Cr Quoted ₹27.2 Cr | L1 | Accepted-AOC Accepted Bid |
| 2 | L2₹27.8 CrRejected-Finance HARSH ANAND YEVALEKAR MALA COLLEGE ROAD NASHIK 422005 | NASHIK | NASHIK | MAHARASHTRA | 422005 | ₹27.8 Cr | L2 | Rejected-Finance Due to High Rates |
| 3 | Rejected-Technical PLOT NO 3 YOGANAND CO OP HOUSING SOCIETY BEHIND BIJAN HOSPITAL NEAR MALPANNI HOSPITAL VIGHA MALA CANADA CORNER COLLEGE ROAD NASHIK | NASHIK | NASHIK | MAHARASHTRA | - | - | Rejected-Technical Not Qualified |
Tender Value
₹22.9 Cr
EMD Value
₹11.4 L
Closing Date
29 Jun 2023, 5:00 pmClosed
Executive Engineer, P.W.Division, Nashik
Executive Engineer Public Works Division Nashik Bhandkam Bhawan Trimbak Road Nashik Tal. Dist. Nashik Tel. No.- 0253-2583761-64 2575324
Construction of District Sport Complex at Nashik Tal. Dist. Nashik (Civil and Electrical Works)
2023_PWR_915469_1
E-Tender Notice No.15 for 2023-24 (Item Rate)
Open Tender
Civil Works
545 days
Tal.Dist. Nashik
As Per NIT
9 documents required · 9 mandatory
₹3,540
₹11.4 L
The Chief Engineer, Public Works Region, Nashik
9 Dec 2023
14 Jun 2023
30 Jun 2023
14 Jun 2023
29 Jun 2023
14 Jun 2023
23 Jun 2023
Amount
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth up to 300 millimetre, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable material to be used or auctioned up to a lead of 1000 metres including removal and disposal of top organic soil not exceeding 150 millimetre in thickness.
Providing earth work in embankment with approved materials obtained from other sources upto lead of 50 metre including all lifts, laying in layers of 20 centimetre to 30 centimetre thickness breaking clods, dressing to the required lines, curves, grades & section, watering and compaction with vibratory roller with V-Sat attachment to achieve not less than 97 Percent of standard proctor density etc. complete (Material obtained from Other sources)
Excavation for foundation in earth, soil of all types, sand, gravel and soft murum, including removing the excavated material up to a distance of 50 metre. beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.5 metre)
Excavation for foundation in hard murum including removing the excavated material upto distance of 50 metres beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift upto 1.50 metre)
Excavation for foundation in Hard murum and boulders including removing the excavated material upto a distance of 50 metres, beyond the building area and stacking and spreading as directed, dewatering, preparing the bed for the foundation and necessary back filling, ramming, watering including shoring and strutting etc. complete. (Lift from 1.5 metre to 3.0 metre)
Excavation for foundation in Soft rock and old cement or lime masonry foundations including removing the excavated material upto a distance of 50 metres beyond the building area and stacking as directed, including dewatering, preparing the bed for the foundation and necessary back filling with available earth/murum, ramming ,watering including shoring and strutting etc. complete. (Lift from 1.5metre To 3.0 metre)
Excavation for foundation in Hard rock by chiselling, wedging, line drilling, etc. including trimming and levelling the bed, removing the excavated material upto a distance of 50 metres beyond the building area stacking as directed, dewatering and back filling with available earth/ murum watering, ramming etc. complete. (Lift upto 1.5 metres).
Excavation for roadway in earth, soil of all sorts, sand, gravel or soft murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50 metre and spreading for embankment or stacking as directed.
Excavation for roadway in hard murum including dressing section to the required grade, camber and side slopes and conveying the excavated materials with all lifts upto a lead of 50metre and spreading for embankment or stacking as directed.
Providing and laying Cast in situ / Ready Mix cement concrete in M-15 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor Grade etc)
Providing and laying Cast in situ / Ready Mix cement concrete in M-10 of trap/ granite/ quartzite/ gneiss metal for foundation and bedding including bailing out water, formwork, laying/pumping, compacting, roughening them if special finish is to be provided, finishing if required and curing complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/concrete Batch mix plant (Pan mixer) etc. complete. With fine aggregate (Crushed sand Vertical Shaft Impactor Grade etc)
Filling in plinth and floors with approved excavated material in 15 centimetre to 20 centimetre layers including watering and compacting etc. complete. Spec. No. : Bd.A. 11/Page No. 262
Filling in plinth and floors with contractors material/brought from outside and approved by Engineer in charge in layers of 15 centimetre to 20 centimetre. including watering and compaction etc. complete. Spec. No. : Bd.A. 11/Page No. 263
Providing dry/ trap/ granite/ quartzite/ gneiss rubble stone soling 15 centimetre to 20 centimetre thick including hand packing and compacting etc. complete.
Providing and laying in situ / Ready Mix cement concrete M-35 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying / pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
Providing and laying in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying / pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
Providing and laying in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete work in foundations like raft, strip foundations, grillage and footings of Reinforced Cement Concrete columns and steel stanchions etc. including bailing out water, formwork, laying / pumping cover blocks, compaction and curing roughening the surface if special finish is to be provided (Excluding reinforcement and structural steel) etc. complete, with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
Providing and laying Cast in situ / Ready Mix cement concrete M-35 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor
(B) First Floor
Providing and laying Cast in situ / Ready Mix cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete columns as per detailed designs and drawing or as directed including centering, formwork, cover blocks, laying/pumping, compaction finishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete,(Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
Providing and casting in situ cement concrete M-25 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks compaction and roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled concrete batch mix plant (pan mixer). With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and casting in situ cement concrete M-20 of trap / granite /quartzite/ gneiss metal for Reinforced Cement Concrete beams and lintels as per detailed designs and drawings or as directed including centering, formwork, cover blocks compaction and roughening the surface if special finish is to be provided and curing etc. complete. (Excluding reinforcement and structural steel), with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled concrete batch mix plant (pan mixer). With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade
Providing and laying Cast in situ/ Ready Mix cement concrete M-40 post tensioning in Post-Tension slabs and Post-Tension Beams for the loading as mentioned in relevant drawing as per the technical specifications including decoiling the strands, cutting to the required lenghts, supplying and laying of HT strands (Tata Make), sheating (Galavanized Iron ducts), jointing with couplers and inserting the strands,profiling, fixing live end anchorages including the supply of stressing anchorages, grout vents,making dead end anchorages including flowering the strands,fixing tendon support bars,supervising the fixing of anti‐bursting reinforcement, stressing the cable end trimming, grouting the cables with cement slurry mixed with approved admixtures with required tools ,plants,machineries and consumables etc. including demarcationon soffit of the slab with 100 wide red paint indicating cable profiles,including obtaing approval from client/consultant for the work done of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete Slabs and Landings as per detailed designs and drawings including centering , formwork, cover blocks, laying/ pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel) with fully automatic micro processor based Programmable Logic Controller with Supervisory Control And Data Acquisition enabled Reversible Drum Type mixer/ concrete Batch Mix plant (Pan mixer) etc. complete, with fine aggregate (Crushed sand Vertically Shaft Impactor Grade). Including all lead and Lifts, as directed by Engineer in charge. (A) Ground Floor
(C) Second Floor
Providing and laying Cast in situ / Ready Mix cement concrete M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete chajja as per detailed design and drawings including centering, formwork, cover blocks compacting , curing , finishing and roughening the surface if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-25 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete M-20 of trap/ granite / quartzite/ gneiss metal for Reinforced Cement Concrete slabs and landings as per detailed designs and drawings including centering, formwork, cover blocks, laying/pumping, compactionfinishing the formed surfaces with cement mortar 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening if special finish is to be provided and curing etc. complete, (Excluding reinforcement and structural steel).with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade )
Providing and laying Cast in situ/Ready Mix cement concrete in M-25 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete pardi of required thickness including centering, formwork, cover blocks, laying/pumping, compacting , curing , finishing and rougheningthem if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and laying Cast in situ / Ready Mix cement concrete in M-25 of trap / quartzite /granite /gneiss metal for Reinforced Cement Concrete Waist slab, and steps of staircases as per detailed design and drawings or as directed including steel centering, plywood/ steel formwork, steel props, laying / pumping, compaction, finishing uneven and honeycombed surface with Cement Mortor 1:3 of sufficient minimum thickness to give a smooth and even surface or roughening the surface if special finish is to be provided and curing etc. complete. (Excluding einforcement, including cover block).(Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc.) with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing during laying in Reinforced Cement concrete Slab rectangular 2 millimetre thick Mild Steel sheet fan hook box of size 180 X 100 millimetre with required depth with holes or notches as required, bottom and top sides of 1.6 millimetre Mild Steel sheet fixed with 3.5 millimetre diametre round headed screws together with 12 millimetre diametre Mild Steel bar bent to shape with hooked ends for fan hook and painting to exposed surface (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and laying Cast in situ/Ready Mix cement concrete in M-20 of trap/ granite/ quartzite/ gneiss metal for Reinforced Cement Concrete coping to plinth or parapet and sill of doors and windows moulded as per detailed drawings or chamfered as approved by the Engineer including centering, formwork, cover blocks, laying / pumping, compacting, curing, finishing and roughening them if special finish is to be provided and curing complete. (Excluding reinforcement and structural steel). with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade) (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and laying Cast in situ / Ready Mix cement concrete in M20 of trap metal for bed blocks, foundation blocks and such other items including bailing out water, Steel centering, formwork, laying/ pumping, compacting, roughening them if special finish is to be provided, finishing uneven and honeycombed surface and curing etc. complete. The Cement Mortar 1:3 plaster is considered for rendering uneven and honeycombed surface only. Newly laid concrete shall be covered by gunny bag, plastic, tarpaulin etc. (Wooden centering will not be allowed.), with fully automatic micro processor based Programmable Logic Controller with Supervisory Control and Data Acquisition enabled reversible Drum Type mixer/ concrete Batch mix plant (Pan mixer) etc. complete. With fine Aggregate( Crushed sand/Vertical Shaft ImpactorGrade)
Providing and fixing in position Thermo Mechanically Treated - FE - 500 bar reinforcement of various diameters for Reinforced Cement Concrete pile caps, footings, foundations, slabs, beams columns, canopies, staircase, newels, chajjas, lintels pardis, copings, fins, arches etc. as per detailed designs, drawings and schedules. including cutting, bending, hooking the bars, binding with wires or tack welding and supporting as required complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing structural steel work in trusses, other similar trussed purlins and members with all bracing, gusset plates etc. as per detailed designs and drawings or as directed including cutting, fabricating, hoisting, erecting fixing in position, Making riveted/ bolted/ welded connection and one coat of anticorrosive paint and over it 2 coats of oil painting approved quality and shade etc. complete. (A) Ground Floor
(B) First Floor
Providing fly ash brick masonry with conventional / Indian Standard type fly ash bricks in Cement Mortor 1:6 in foundation and plinth including bailing out water manually striking joints, racking out joints watering and scaffolding etc. complete.
Providing fly ash brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing Second class fly ash brick masonry with conventional / Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of two bars of 6 millimetre diameter / two hoop iron strips 25 millimetre x 1.60 millimetre at every third course, properly bent and bounded at ends scaffolding raking out joints and watering etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing second class Burnt Brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in foundations and plinth of inner walls/ in plinth external walls including bailing out water manually , striking joints on unexposed faces, raking out joints on exposed faces and watering etc. Complete.
Providing second class Burnt Brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:6 in superstructure including striking joints, raking out joints, watering and scaffolding etc. Complete
Providing second class Burnt Brick masonry with conventional/ Indian Standard type bricks in cement mortar 1:4 in half brick thick wall including mild steel longitudinal reinforcement of 2 bars of 6 millimetre diameter / 2 hoop iron strips 25 millimetre X 1.6 millimetre placed at every third course, properly bent and bonded at ends scaffolding, racking out joints and watering etc. complete.
Providing internal cement plaster 12 millimetre thick in single coat in cement mortar 1:5 without neeru finish to concrete or brick surfaces, in all positions including scaffolding and curing etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing neeru finish to plastered surfaces in all positions including scaffolding and curing etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and applying Two coats of wall care Putty on plastered surface and Ceiling and Walls to prepare surface even and smooth of approved make, etc complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing waterproof plaster in Water Closet and bath 20 millimetre thick for dado in cement mortar 1:3 with neat finishing, floating using waterproofing compound at the rate of 1 kilogram per bag of cement of approved make and manufacturer and curing (and filling joints of Nahani trap and any outlet by properly) etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing internal cement plaster 12 millimetre thick in single coat in cement mortar 1:3 without neeru finish to concrete or brick surfaces, in all position including scaffolding and curing etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing internal cement plaster 20 millimetre thick in two coats in cement mortar 1:4 without neeru finish, to concrete, brick surface, in all positions including scaffolding and curing etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing sand faced plaster externally in cement mortar using approved screened sand, in all positions including base coat of 15 millimetre thick in cement mortar 1:4 using waterproofing compound at 1 kilogram per cement bag curing the same for not less than 2 days and keeping the surface of the base coat rough to receive the sand faced treatment 6 to 8 millimetre thick in cement mortar 1:4 finishing the surface by taking out grains and curing for fourteen days scaffolding etc.complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and applying Texture plaster with finishing with Purlina / Rustic texture material ( with texture material of Asian / Renava / Nitco / Temtex or equivalent company make ) in 3 to 4 millimeter thickness on previously finished plastered surface including Plaster Groove 6 millimeter thickness or Tape Grooves 35 to 45 millimeter thickness or as required, in all position including preparing the surface scaffolding etc.complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing patti/ band 150 millimetre wide on plastered surface 12 millimetre to 15 millimetre thick in Cement Mortor 1:3 line and level including neat finishing scaffolding curing etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing chicken mesh of 22 gauge, with about 30 centimetre width at the junction of Rrinforced Cement Concrete members and brick work, of approved quality including fixing mesh in position by necessary drilling in concrete / Burnt Brick masonry and or tying by binding wire etc. complete.
Providing fine cement finish 1.5 millimetre thick over green plaster surface including scaffolding curing etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and laying in position flooring of telephone black / Amba White / Cat bary brown / Ruby red / Ocean Brown granite stone of approved shade and size 18 millimetre to 20 millimetre thick on bed 1:6 cement mortar including cement floats striking joints, pointing in Cement Mortor 1:3 curing and cleaning etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and laying vitrified matt fininsh tiles having size 590 millimetre to 605 millimetre x to 605 millimetre of 8 to 10 millimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement morar including neat cement float, filling joints, curing and cleaning etc. complete. a) Flooring (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and laying chequered tiles of approved quality of size 30 centimetre x 30 centimetre for flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete.
Providing and laying Antiskid Ceramic tiles of approved quality of size 30 centimetre x 30 centimetre and confirming to Indian Standard 15622-2006 (Group-B HA) for antiskid flooring in required position laid on a bed of 1:4 cement mortar including cement float, filling joint with cement slurry cleaning curing etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and laying vitrified matt finish tiles having size 590 millimetre to 605 millimetre x to 605 millimetre of 8 to 10 millimetre thickness and confirming Indian Standard 15622-2006 (Group Bla) of approved make, shade and pattern for flooring in required position laid on a bed of 1:4 cement mortar including neat cement float, filling joints, curing and cleaning etc. complete. b) Skirting (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and laying Polished Tandur Stone flooring 25 millimetre to 30 millimetre thick required width in plain/ diamond pattern on a bed of 1:6 Cement Mortor including cement float, filling joints with neat cement slurry, curing, polishing and cleaning etc. complete. (A) Ground Floor
(C) Second Floor
Providing and laying ceramic tiles having size 30 centimetre x 60 centimetre confirming to corresponding India Standard for dado and skirting in required position with readymade adhesive mortar of approved quality on plaster of 1:2 cement mortar including joint filling with white/ colour cement slurry cleaning curing etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing in position Phenol bonded Bamboo wood flooring with planks of sizes 14 millimetre thick, 1800 millimetre length (minium) and 130 millimetree wide (minimum), in approved colour, texture and finish, having Performance Appraisal certified (PAC) issued by Building Materials and Technology Promotion Council (BMTPC). The flooring shall be fixed with tongue and groove interlocking system, with underlayment of 4 millimetre thick expanded poly ethylene foam sheets having density 40 killogram per One Cubic metre, over prepared surface with necessary quarter round planks of size 1900 millimetre x 18 millimetre and door reducer of size 1900 millimetre x 44 millimetre, whereever required. The bamboo wood planks shall have minimum density of 1000 killogram per One Cubic metre and minimum Hardness 1000 killogramf. with Eco friendly Ultra Voilet coating, all complete as per direction of Engineer in -charge. Ground floor
Wrestling Matt - Supplying and Fixing Surface that is Approved by World Taekwondo Federation (WTF). Material: XPE, Leather with pattern Technology improvement: Low ratio XPE and dedicated leather with pattern, Absorbing energy, great performance of buffering, excellent breathability, soft surface; compounded by fire, connected by toothed edge, more stable.etc comple and as directed by engineer in charge (Tile size of 1 Metre X 1 Metre X 50 Millimetre, colour options-Red, blue, yellow, green) (B) First Floor
Judo Matt - Supplying and Fixing Surface that is Approved by World Taekwondo Federation (WTF). Material: XPE, Leather with pattern Technology improvement: Low ratio XPE and dedicated leather with pattern compounding to this new Model mat. 8 metre octagonal competition area is blue, safety area is red. Absorbing energy, great performance of buffering, excellent breathability, soft surface; compounded by fire, connected by toothed edge, more stable.(Tile size of 1Metre X 1Metre X 50Millimetre, colour options-Red, blue, yellow, green)
Supply and Installation of European Origin, FIBA, BWF and IHF Certified, Point Elastic polyurethane Flooring 'Pulastic Classic 110' having thickness of 11 millimetre comprising of 9 millimetre Prefabricated SBR Mat followed by 2 millimetre Polyurethane Coatings. Seamless, non-porous and smooth surface for Very good resiliency for comfort, injury prevention, Sustainability through high content of recycled and renewable raw materials in combination with lasting performance through very good mechanical strength, wear resistance and easy maintenance, repair and resurface procedures. System consist of SBR Matt being laid using two component Polyurethane Adhesive followed by Sealer to fill in all the pores of SBR mat, 2 coats of Polyurethane Resin Layer followed by Top Polyurethane Coat and game line marking. Product should meet European standards EN-14904 - P1 category, Shock Absorption: 28 % as per EN 14808, Vertical Deformation: 1.4 millimetre as per EN 14809, Friction value according to EN 13036-4 should be on or above 107, Ball Bounce: 98 % according to EN 12235, Gloss: 5 % as per EN 2813, Resistance to Rolling Load: ≥ 1500 N as per EN 1569, Resistance to impact: ≥ 800 gr @ 10°C & ≥ 1200 gr @ 23°C as per EN 1517, Resistance to indentation: 0,35 millimetre @ 5 minutes and 0,15 millimetre @ 24 hours as per EN 1516, Resistance to wear: < 340 mg as per EN ISO 5470, Flammability: Bfl-S2 as per EN 13501-1, Improvement impact sound insulation (∆Lw): 21dB according to ISO 717-2, Volatile Organic Compound content – adhesive/resins Solvent free, Resin composition Free of solvents and heavy metals, Elongation at break: structure 150 % as per DIN 53455, Tensile strength: structure 8 Newton per Square millimetre according to DIN 53455, Tear strength: structure 25 Newton per Square millimetre according to DIN 53515. Consumption of materials has be as per standards which is 0.90 Killogram per square metre Adhesive for SBR Matt, 0.5 Killogram per square metre Sealer, 2.8 killogram per suare metre Polyurethane Wear Coating followed by 0.14 Killogram/square metre Top Polyurethane Color Coat. Product should be manufactured under Indian Standard Organization 9001 for quality management , Indian Standard Organization 14001 for environmental care and Indian Standard Organization 26000 for corporate sustainability. (C) Second Floor
Providing sills of required material 20 millimetre to 25 millimetre thick, on a bed of cement mortar 1:4 including cement float, filling joints with neat cement slurry, curing, polishing, rounding edges, cleaning complete, b) Granite (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and laying telephone black / Amba White / Cadburybrown / Ruby red / Ocean Brown granite stone of 18 to 20 millimetre thick for door frame/ dado/ window boxing etc. on Cement Mortor 1:6 including filling joints with polymer base filler nosing the sharp edges wherever necessary, curing, etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing machine cut machine polished 18 millimetre to 20 millimetre thick telephone black / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone for treads and risers of steps and staircases of approved colour and shade with rounded moulding and three grooved line for the treads on bed of 1:4 Cement mortar including float filling joints with neat cement slurry curing polishing and cleaning etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and applying priming coat on concrete/ masonary/ Asbestos Cement plastered surfaces including scaffolding if necessary, preparing the surface by thoroughly cleaning oil, grease, dirt and other foreign matter and sand papering as required etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and applying plastic emulsion paint of approved quality, colour and shade to old and new surfaces in two coats including scaffolding, preparing the surface, (excluding the primer coat)etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and applying two coats of exterior acraylic emulsion paint confirming to corresponding Indian Standard of approved manufacture and of approved colour to the plastered surfaces including cleaning, preparing the plaster surface, applying primer coat, scaffolding if necessary, and watering the surface for two days etc complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and applying two coats of textured synthetic paint of approved shade and quality and one coat of primer before applying textured paint including scaffolding if necessary preparing surface by thoroughly cleaning oil, grease, dirt and other materials as required, etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing and applying melamine polish of required finish to the wood work by spray machine including knotting and preparing the even surface by scraping, applying French polish , scaffolding if required etc. complete. Note:The work to be executed on prior approval of Superintending Engineer will be necessary. (A) Ground Floor
(B) First Floor
Providing and fixing frame with / without ventilator of size as specified with Country cut teak wood for doors and windows including chamfering, rounding, rebating, iron holdfast of size 300 millimetre X 40 millimetre X 5 millimetre with oil painting, etc. complete (A) Ground Floor
(B) First Floor
Providing and Fixing Door Frame Made out of 12 and 18 millimetre Plywood with Mica Laminate (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing M-40 grade thick vibrated pull cast or similar type concrete frame with chamfer conforming to Indian Standard 6524-1983 having 6 millimetre diametres bars 3 Numbers And stirrups @ 250 millimetre centre to centre and fixing in wall with 6 Numbers of hold fast of 12 millimetre diametre bars 500 millimetre long including primer and oil painting etc, complete) frame size 60 millimetre x 100 millimetre. (B) First Floor
(C) Second Floor
Providing and fixing Country cut teak wood double or single leaf panelled shutters, 35 millimetre thick style top and freze rail 95 x 35 thick with lock and bottam rail 195 x 25 millimetre thick and panels without ventilator as per detailed drawing excluding the door frame, stainless steel fixtures and fastening and finishing the wood work with oil painting 3 coats complete. (A) Ground Floor
(B) First Floor
Providing and fixing solid core flush door shutter in double leaf 32 millimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing solid core flush door shutter in single leaf 32 millimetre thick decorative type of exterior grade as per detailed drawings approved face veneers 3 millimetre thick on both faces or as directed, all necessary beads, mouldings and lipping, wrought iron hold fasts, chromium plated fixtures and fastenings, with brass mortise lock, chromium plated handles on both sides, and finishing with French Polish etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing Indian Standard Institute marked double swing flush door shutters conforming to Indian Standard :2202 (Part I) Non-decorative type, core of block board construction with frame of 1st class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 30 millimetre thick including Indian Standard Institute marked Stainless Steel L- hinges with necessary screws Fittings and Fixtures per leaf Stainless steel kick plates on both sides of the door of 300 millimetre height Heavy Duty satin finish butt Stainless Steel Hinges (100 millimetre x 75 millimetre x 3 millimetre in size) - 4 numbers Stailess Steel finished lever handle with mortise lock- 1 no. Floor spring- 1 Number 100 millimetre x 100 millimetre safety glass at the specified location (A) Ground Floor
Providing and fixing in position (as per 1868 / 1982) Aluminium sliding window of three tracks with rectangular pipe 95 X 38.10 X 0.90 millimetre at weight 0.637 kilogram per Running metre. with window frame bottom track section 92 X 31.75 X 1.30 millimetre at weight 1.070 kilogram per Running metre. Top and side track section 92 X 31.75 X 1.30 millimetre at weight 0.933 kilogram per Running metre. The shutter should be of bearing bottom 40 X 18 X 1.25 millimetre at weight 0.417 kilogram per Running metre. Inter locking section 40 X 18 X 1.10 millimetre at weight 0.469 kilogram per Running metre. and handle and top section 40 X 18 X 1.25 millimetre at weight 0.417 kilogram per Running metre. As per detailed drawings and as directed by Engineer in charge with all necessary Aluminium sections fixtures and fastenings such as roller bearing in nylon casting and self locking catch fitted in vertical section of shutter including 5 millimetre thick plain glass and aluminium mosquito net shutter with stainless steel jail with all required screws and nuts etc, complete. With powder coating without box (A) Ground Floor
(B) First Floor
(C) Second Floor
a) Supplying and fixing in position Colour anodized Aluminium four track sliding windows with outer frame made from section of over all size 122 millimetre x 45 millimetre, bottom section with drain section track weighing 1.83 Kilogram per metre and top and side section of size 122x 31.75 millimetre weighing 1.15 Kilogram per running metre with shutter sections made of 18 millimetre x 40 millimetre size having average weight of 0.6 Kilogram per running metre (or as required size) with change in proportionate weight, with 6 millimetre float glass in three equal panels and alluminium coated stainless steel mosquito net in one (2/3 of opening) panel fixed with new neoprene gasket, shutters to be provided with nylon encased stainless steel rollers, necessary locks and handles complete. (A) Ground Floor
Providing and fixing in position powder coated aluminium louvered windows / ventilator of various sizes with powder coating as per detailed drawing and specifications including aluminium frames 80 x 38 millimetre x 1.22 millimetre box type, 5 millimetre thick sheet glass louvers, of approved quality etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing in position aluminium fixed window fully glazed of any size as per detailed drawing and as directed by Engineerincharge with all necessary alluminium sections including necessary fixtures and fastening such as 5 millimetre thick clear float glass etc. complete. b) With powder coating Note While arriving at the rate of item of item weight at 6.90 kilogram per Squaremetre is considered. (A) Ground Floor
Providing and fixing mild steel grill work for windows, ventilators etc. 20 kilogram per squaremetre as per drawing including fixtures, necessary welding and painting with one coats of anticorrosive paint and two coats of oil painting complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing in position Gypsum board false ceiling with 12.5 millimeter thick Gypsum boards, screwed / fixed to the under structure of suspended Galvanised Iron Grid constructed and suspended from the main ceiling consisting of ceiling sections of size 25 x 50 millimeter maximum center to center distance of 600 milimetre perimeter channel and intermediate channels at maximum center to center distance 1200 milimetre galvanized grid should be fixed to reinforced cement concrete slab. The gypsum board should be fixed to galvanized iron grid with necessary screws. The boards should be taped and filled from underside to give smooth, seamless ceiling. The rate should include necessary additional ceiling sections and intermediate channels. Additional intermediate channels should be fixed to strap hangers for additional support to prevent strapping at every 1200 milimetre item to be completed in all respect including necessary sleeves for ducts finishing of joints cut outs, painting including labour, material, lifts etc. all complete. (A) Ground Floor
(B) First Floor
Kitchen Trolley Providing and Fixing stainless steel kitchen trolley of overall 26 " height and 22" depth,supported on aluminium pipes ,trolley basket made out of 5 millimetre stainless steel rod fitted on telescopic channel of size 1.5 " x 20 " x 22 " on both sides of trolley of 12 " or above size, panel having 40 kg load bearing capacity of trolley made out of 20 millimetre PUC coated plywood and colour combination as directed by E-I-C.Inner side of panel covered by white mica ,100 millimetre s.s. decorative handle.(The width and height of individual compartments shall be kept as directed by Engineer-in-charge) (B) First Floor
Providing and constructing granite kitchen platform with fixing of stainless steel sink 600 millimetre x 450 millimetre size as per detailed drawing including vertical both side polished kadappah stone 25 to 30 millimetre thick supports with kadappah top 35 to 40 millimetre thick and polished granite 16 to 20 millimetre top with side strips of granite at front and both sides of platform raised with two vertical granite supports 15 centimetre height and top granite of 75 x 40 centimetre including cutting, opening for sink of required size in kadappah as well as granite etc. complete. (B) First Floor
Providing and fixing black kadappa stone shelves 25 millimetre thick machine polished, extending the polish upto 20 centimeter width on lowerside, rounding comers, laying in position jointing with bedding cement mortar 1:4 proportion curing etc complete. (A) Ground Floor
(B) First Floor
Providing and Fixing mat finish stainless steel (of 302 grade ) railing with top pipe of 50 millimetre diametre and vertical pipe of 38 millimetre diametre at 0.60 metre centre to centre or as required and horizontal pipes of 25 millimetre diametre in three rows, all pipes of 2 millimetre thick including buffing,fabricating fixtures and fastening including pipe base of appropriate diameter and ball base of 75 millimetre diametre above newel post of 75 millimetre diameter etc. complete (Prior approval of sample and brand by Ex. Engineer is necessary before use) (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the bottom surface and sides of excavation at the rate of 5 litres of emulsion concentrate of 1.0 percent of chlorophyrifos per square meter of surface area covering 10 years guarantee on bond paper.
Providing antitermite treatment around the periphery of the existing building as per Indian Standard 6313 (Part-Hi) by excavating trenches of 20 centimeter width and exposing the sides of columns and plinth beams upto a depth of 300 millimetre and injecting one percent of chlorodane emulsion concentrate at the rate of 2.25 litres per Rmt and refilling the trenches etc. complete covering 2 years guarantee on bond paper.
Providing preconstructional antitermite treatment as per Indian Standard 6313 (Part-II) by treating the top surface of plinth filling at the rate of 5 litres of emulsion concentrate at 0.5 percent of clorophyrifos per square metre of surface area covering ten years guarantee on bond paper. ( AS per Item no. 22.43 of schedule of rates of NBO )
Providing and fixing Galvanised Iron Pre coated trapezoidal Metallic coloured sheets of 0.50 millimetre thickness (26 Birmingham Wire Gauge) of approved make for roofing without wind ties including fastening with galvanised iron screws and bolts and lead and bitumen washers as per drawing complete. Spec. – As directed by Engineer-in-charge. (B) First Floor
Providing and fixing self supporting steel roofing system (Proflex) for a Godown or alike made up of structural grade steel sheet of 912 millimeter width ( tolerance +/- 2 millimeter ), moulded at site using mechanical press dies to the desired curve and shape to form 605 millimeter wide interlocking panels . The interlocking panels shall be pressed to close the seam forming water tight joints for a span of 15.30 meter having arch rise as 3.06 meter, arch length 17.75 meter. The base material made up of imported galvalume steel complying to ASTM A792 having base metal thickness of 0.80 millimeter ( tolerace + / - 0.02 millimeter ) with alloy coating AZ 150 and paint coating of regular modified polyster , top coat 25 micron and bottom coat 12 micron as per approved colour , including fixing hangers , clamps etc.as may be necessary of Proflex standard, including fixing sky light of 2 millimeter thick polycarbonate sheet of size 2' x 7' and turbo ventilator of 24'' diameter to be installed at every 30 feet along the length of roof including finishing, testing and cleaning etc. complete. (D) Third Floor
Supply and Installation of translucent roof with DPI Flux standing seam multicell polycarbonate panel system. The system with complete assembly of co extruded Ultra Voilet protected multicell panels incorporated into a complete system. Co-extruded Ultra Voilet protected polycarbonate panel system of minimum 12 millimetre thick of 900 millimetre (mininum) width with angular daylighting concept. Panels shall have minimum six layers with truss bridge design for higher flexibility and strength. Panels with all fixing accessories to ensure best performance for wind uplift, vibration, oil canning and visual appearance. Panels shall be manufactured with vertical standing seam at both sides of the panel. Panels shall be fixed on Purlin with snap on connectors with double tooth grip lock locking mechanism and will be secured on Mild Steel structure (will be paid Separately) with 3 One Numbers self-drilling screws and trapezoid Stainless Steel fasteners holding the base of the standing seam offering best stability having a pull-out load of minimum 7000 Newton (7 Kilo Newton) tested as per ISO 6892:1998 and Indian Standard 1608: 2005, as per design requirement. Panels must satisfy Dart drop impact test as per Indian Standard 14443-97 shall show no sign of breakage on Polycarbonate sheets which have been exposed to Ultra Voilet for a minimum of 500 Hours as per ASTM G 155. Panels shall not have Yellowness Index as per ASTM D 1925 of 15 units when tested on a sample exposed to Ultra Voilet for 500 Hours as per ASTM G 155. U value shall not be more than 1.6 Watt per metre 2K as per EN ISO 10077-2:2018. Panel shall be with additional End cap/Aluminium U/F profile/ Glazing Bar for ends as required. Panel shall be fixed over Mild Steel structural steel/Mild Steel purlin (paid separately) conforming to the detail technical specifications as per approved architectural drawings. Trained and factory authorized labour with supervision to complete the entire panel installation as per drawing & direction of the engineering in charge. Colour: As per Approval. Approved Make: FLUX by DPI Daylighting or approved equivalent The 12 millimetre thick panels shall be used for a roofing height of upto 15 metres.
Providing cement based water proofing treatment to terraces (Indian water proofing or alike) with brick bats laid in required slope to drain the water for any span after cleaning the base surface. Applying a coat of cement slurry admixed with approved water proofing compound and laying the brick bats on bottom layer in Cement Mortor 1:5 admixed with approved water proofing compound filling up to half depth of brick bats, curing this layer for 3 days, applying cement slurry over this layer joints of brick bats with Cement Mortor 1:3 admixed with approved water proofing compound and finally top finishing with average 20 millimetre thick layers of same mortar added with jute fiber at 1 Kilogram per bag including finishing the surface smooth with cement slurry admixed with approved water proofing compound. Marking finished surface with false squares of 300 millimetre X 300 millimetre making the junctions at the parapet rounded and tapered top for required height, with drip mould at the junction of plaster and parapet and curing and covering 10 years Guarantee against leakproofness on Court fee stamp paper of Rupees 500/- including ponding test etc. complete. (A) Ground Floor
(B) First Floor
(D) Third Floor
Providing water proof bedding for flooring of Bath and Water Closet 25 millimeter thick in Cement Mortor 1:3 including using approved water proofing compound in specified proportion as per manufacturers specifications for per bag of cement including leveling, curing and covering 10 years guarantee on court fee stamp paper of Rs.500/- including ponding test etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and laying in trenches 15 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and laying in trenches 20 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and laying in trenches 25 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and laying in trenches 32 millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and laying in trenches 40millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and laying in trenches 50millimetre diametre Chlorinated Poly Venyl Chloride pipe including necessary excavation, fittings. Refilling trenches etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete.
Providing and fixing on walls/ceiling/floor 15 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing on walls/ceiling/floor 20 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing on walls/ceiling/floor 25 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing on walls/ceiling/floor 32 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing on walls/ceiling/floor 40 millimetre diametre Chlorinated Poly Venyl Chloride pipe with necessary fittings, remaking good the demolished portion etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and making Indian Standard Institute Mark ferrule connection of 32 millimetre diametre to water main including ferrule coupling cast iron bell mouth cover, built in non return valve and fixing including excavation and reinstatement complete.
Providing, laying and fixing Poly Vinyl Chloride pipe of 110 millimetre diametre with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing Poly Vinyl Chloride Rain water pipes of 160 millimetre outer diameter and having wall thickness of 2.2 to 2.7 millimetre confirming to Indian Standard 13592-1992 including proper rainwater receiving recess with Poly Vinyl Chloride plug, bend, necessary fittings, such as, offsets, shoes, inluding fixing the pipe on wall using approved wooden cleats projecting 25 millimetre to 40 millimetre from face of wall a fixing with clips of approved quality and number, filing the joint using rubber gasket with solvent cement and properly resting the shoe of pipes on CEment Concrete or masonry blocks, including necessary scaffolding and maintenance for 3 yrs for any leakages or dislocations of pipes. All the Poly Vinyl Chloride fittings and additional 2 piece socket clips shall be got approved from engineer in charge etc. complete. (The contractor shall give 3 yrs guarantee bond for payment) (A) Ground Floor
(B) First Floor
(C) Second Floor
(D) Third Floor
Providing, laying and fixing Poly Vinyl Chloride pipe of 75 millimetre diametre with fittings such as bends, tees, reducers, clamps, etc. including necessary excavation, trench filling etc. complete. Including removing existing pipe line if necessary and conveying and stacking the same in PWD chowky or as directed etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing Chromium Plated BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing screw down 15 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing screw down for 25 millimetre diameter wheeled stop tap of brass including necessary sockets/union nut complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing Chromium Plated 2 Way BIB cock with wall flange of approved make including necessary sockets/ union nut etc. complete as directed by Engineer in charge. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing 15mm diameter concussion push button type brass/gun metal self-closing tap including necessary socket complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing 10 centimetre Poly Venyl Chloride nahani trap with grating etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing 25millimetre diameter water meter with non-return valve including strainer, sockets/ union nut and including water meter box making locking arrangement and lock. [Without chamber].
Providing and fixing 1st class white glazed earthenware Orissa Type Water Closet Pan 580 millimetre diametre including P or S trap cast iron soil and vent pipe upto the outside face of the wall (1:5:1 0) cement concrete bedding 15 mm thick, 10 liter Poly Vinyl Chloride flushing cistern with all necessary pipe connection etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing Wall Mounted European type white glazed earthenware water closet pan with Unplasticized Poly Vinol Chloride seat and lid with chromium plated brass hinges and rubber buffers including Unplasticized Poly Vinol Chloride and vent pipe up to the outside face of wall 10 liter enameled low level flushing cistern with fittings pipe stop tap brackets for fixing cistern 32 millimetre diametre Unplasticized Poly Vinol Chloride flush pipe with fittings and clamps, 20 millimetre diametre Unplasticized Poly Vinol Chloride overflow pipe ,mosquito proof couplings Galvanised Iron chain and pulley,with water Jet and fitting including cutting and making good to the walls and floors testing etc. complete.( prior approval of sample and brand by Ex. Engineer is necessary before use) (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing White Glazed Earthenware full stall type Urinal with Poly Vinyl Choride flushing cistern of 5 liters capacity with fitting, inlet pipes and stop tap, brackets for fixing the cistern, 32 millimetre diametre Poly Vinyl Choride flush pipe with fittings and flushing arrangement including lead soil pipe, lead trap, soil pipe connection up to the outside face of the wall (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and Fixing toilet set for differently Abled persons consist of Floor Mounted white vitreous china water Closet including 6 litre capacity white vitreous china flushing Cistern with raised soft-push button, white vitreous china wash basin of size 46 x 36 centimetre and one no Stainless Steel 304 hinged rail 76 centimetre and three no Stainless Steel 304 of (Grab Bar) 60 centimetre all including cutting and making good the walls and floors wherever required ,seat cover, cistern and wash basin fittings,nuts, bolts and gasket etc complete of make Hindware(Matrix series 70002)/ Cera or equivalent as per the direction of Engineer-In-charge. (A) Ground Floor
Providing and fixing oval type under counter wash hand basin of 16 inch x 22 inch size and of special colour shade having telephonic black / coloured granite of 180 millimetre thick stone black kadappa framework including chromium plated coupling bottle - Trap using CERA company or equivalent oval typa wash basin model no 3448 as per detailed drawing or as directed by engg in charge etc complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing chromium plated towel rod 16 millimetre diametre and 75 centimetre in length including all accessories complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing 450 millimetre X 550 millimetre size superior type Belgium mirror with 16 milimetre diametre nickel plated towel rod etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and laying for 150 millimetre diametre salt glazed stoneware pipe including fittings Such as bends, tees, single junction, double junctions laying, jointing (including excavation and refilling the trenches) complete.
Providing and fixing 15 centimeter x 10 centimeter salt glazed stoneware gully trap in cement concrete 1:4:8 outside the building including cast iron grating in the sink, connecting glazed stoneware pipe, brick masonry chamber with cast iron lid and cast iron grating for the gully trap.
Providing and constructing Brick Masonry Inspection Chamber 60 centimetre X 45 centimetre X 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stoneware pipepipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete etc. complete with Reinforced Cement Concrete Cover.
Providing and constructing Brick Masonry Inspection Chamber 90 centimetre X 45 centimetre X 90 centimetre including 1:4:8 cement concrete foundation 1:2:4 cement concrete channels half round Glazed Stoneware pipepipes, Brick Masonry, plastering from inside and with frame fixed in cement concrete with Reinforced Cement Concrete Cover.
Providing and fixing 40 millimetre dia Ball cock medium type with Poly Vinyl Chloride float including sockets and necessary fittings and tested as per municipal requirements etc. complete. (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing machine cut mirror polished 18 millimetre to 20 millimetre thick telephone black granite / Amba White / Cat bary brown / RBI red / Ocean Brown granite stone partition with rounding the edges etc. complete . Both side polish (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing and fixing H.D.P container Sintex or alike one piece moulded water tank made out of low density polythyler and built corrugation including of delivery up to destination hoisting and fixing of accessories such as inlet, outlet overflow of all tanks capacity above 1000 to 20,000 litres (A) Ground Floor
(B) First Floor
(C) Second Floor
Providing soak pit of size 120 centimetre X 120 centimetre X 120 centimetre including excavating and filling with brick-bats.
Providing and laying concrete pipes of Indian standard NP. class of 300 millimetre diameter in proper line, level and slope including necessary collars, excavation, laying, fixing with collars in cement mortar 1:1 and refilling the trench complete.
Providing and fixing reinforced cement concrete cover of size 90 centimetre X 45 centimetre with frame over inspection chamber etc. complete. Heavy duty (225 kilogram)
Providing and fixing 90 centimetre X 60 centimetre Granite plate engraving 10cm. height letter, figures including painting the lefters / figures with approved colour and shade complete.
Providing and fixing 45 centimetre wide mild steel ladder of 40 millimetre x 6 millimetre mild steel flat stringers and steps of 18 millimetre diamtre mild steel bar for water tank including fixing it in (1:2:4) M-15 cement concrete block 60 centimetre X 30 centimetre X 30 centimetre and painting the ladder complete. (Anti Corossive Paint)
Providing and fixing in position Unplasticized Poly Vinol Chloride ultra violet stabilized 110 millimetre outer diameter cowl dome confirming to Indian Standard-4985 including making joints with solvent cement etc. complete (B) First Floor
(C) Second Floor
Providing and fixing lightening conductor system comprising of erecting Air-Termination consisting of tubular copper rod of 25 millimeter dia. 1.2 millimeter thick with multiple points head 1.2 metre long ( Heavy Duty) welded or clamped to Galvanised Iron pipe pole B grade 50 millimeter diametre of requiired length with Mild Steel round bnase plate 25 centimetre diametre and 10 millimeter thick at bottom embeded in cement concrete 1:3:6 foundation of size 45 centimetre diametre x 45 centimetre Height and providing earthing with copper earth plate of size 60 x 60 x 0.3 centimetre with cadmium plated nut bolts to fix earthing strip burried in specially prepared earth pits 1.5 metre below ground level with 40 kilogram charcoal and salt with altemate layers of charcoal and salt and Galvanised Iron pipe 40 millimeter diametre 2 meter length burried in earth upto earthling plate remining portion above ground level for watering and refilling comcpete Note- Copper strip fropm lightening conductor is not considered in this item.
Providing and fixing copper strip 25 millimeter wide and 3 millimeter thick for lightening conductor including fixing with screws required scaffolding etc.complete Note- Lightening conductor and earthing pits is not considered in this item
Road Marking with Hot Applied Thermoplastic Compound with Reflectorizing Glass Beads on Bituminous Surface- Providing and laying of hot applied thermoplastic compound 2.5 millimetre thick including reflectorizing glass beads @ 250 grams per square metre area, thickness of 2.5 millimetre is exclusive of surface applied glass beads as per IRC:35 .The finished surface to be level, uniform and free from streaks and holes.complete.
Conveying materials obtained from road excavation including all lifts and lead of over 5Kilometre from the site of excavation to the site of deposition as directed.
Making 150 millimetre diametre Bore in all types of Strata with head core including survey for fixing location of bore transporting of machinery and platform, providing laying fixing casing of 150 millimetre diametre Unplacticised Poly Vinyl Chloride Pipe (CS as per IS:12815) having outer diametre 165 and minimum thickness of 5.70 to 6.50 millimetre diametre along with grouting, checking capacity by flushing test etc. complete. Survey for Fixing Location
Making Bore in all types of Strata
Providing and Laying and fixing casing of 150 millimetre diametre Ultra Poly Vinyl Chloride pipe to withstand continous internal hydraulic pressure of 6 kilogram per square centimetre (Cross Section as per IS:12818-1992) having outer diametre 165.40 millimetre and minimum thickness 5.70 to 6.50 millimetre along with grouting.
Checking Capacity by Flushing test
Supplying and erecting submersible pumpset of required Horse Power with 415 Volt, 50 c/s Alternating Current supply suitable for 150 mm dia. borewell, 3 Horse Power (2 Stage) suitable for 200 to 500 Litre Per Minute discharge at 21 to 11 metre head and (max efficiency at 19 metre head and 300 Iitre per minute) discharge and delievery pipeline 80 millimetre diametre a necessary H. type clamp. As per specification No. WP-SMP
Supplying and erecting flat flexible 3 core 2.5 square millimetre Poly Vinyl Chloride sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying and erecting D.O.L. Starter 400 Volt. 3 phase, 50 cycles with no volt coil and overload element with necessary materials and connected to supply upto 7.5 Horse Power (Similar to L and T make MK-1 DOL Model)
Providing and laying in situ cement concrete M -30 with tremix treatment for 200 millimetre thickness for Concrete Road is including laying plastic sheet for 125 micron thickness with groove cutting of 4 millimetre wide and 20 millimetre deep with necessary refilling with bitumen ( excluding reinforcement) with coarse and fine aggregate Vertical Shaft Impactor grade finely washed crushed sand) etc. complete
Construction of granular sub-base by providing close graded Material, mixing in a mechanical mix plant at Optimum Moisture Content, carriage of mixed Material to work site, spreading in uniform layers with motor grader/ Paver on prepared surface and compacting with vibratory power roller to achieve the desired density, complete as per clause 401 -- Plant Mix Method and Grading - I Material
Wet Mix Macadam -- Providing, laying, spreading and compacting graded stone aggregate to wet mix macadam specification including premixing the Material with water at Optimum Moisture Content in mechanical mix plant carriage of mixed Material by tipper to site, laying in uniform layers with paver in sub- base / base course on well prepared surface and compacting with vibratory roller to achieve the desired density. Laying By Grader/Paver.
Prime coat - Providing and applying primer coat with bitumen emulsion on prepared surface of granular Base including cleaning of road surface and spraying, primer at the rate of 0.60 killogram per square metre using mechanical means.
BITUMINOUS MACADAM :- Providing and laying bituminous macadam using crushed aggregate of Grading 1, premixed with bituminous binder, transported at site with Vessel Traffic Services, laid over a previously prepared surface , finished to the required grade, level, alignment, and rolling to achieve the desired density for 80/100 millimetre compacted thickness with drum mix type hot mix plant with Supervisory Control and Data Acquisition having complying essential features of Hot mix plant as per IRC-27 2009 specified conditions and attachments such as electronic load sensor based belt conveyers,automatic synchronization of bitumen and aggregate fedder,built in dust controller system and Programmable Logic Controller for Drum Mix plant, Sensor paver, and Vibratory roller excluding prime / Tack coat etc. complete --Bitumen Viscosity Grade-30 grade 3.30%
Providing and applying tack coat on the prepared surface heating by fames in Boiler and spraying bitumen set footed in bitumen boller on B.T. surface 2.5 killogram per 10 square metre Viscosity Grade - 30 bulk bitumen
BITUMINOUS CONCRETE:- Providing and laying bituminous concrete using crushed aggregates of grading 1, premixed with bituminous binder @ 5.20 per cent by weight of total mix and filler, transported to site with Vessel Traffic Services , laid over a previously prepared surface, finished to the required grade, level, alignment, and rolling to achieve the desired compaction for 50 millimetre compacted thickness with specified grade of Bitumen,Excluding prime / tack coat. For Bitumen of specified grade -- USING Batch mix type hot mix plant with Supervisory Control and Data Acquisition, Sensor Paver, Vibratory roller with Stone Dust filler. (Viscosity Grade-30 bulk bitumen rates are considered to arrive at rates)
Supply & Installation of IAAF European Track Sandwich system which should have been officially recommended and certified by World Athletics (earlier known as IAAF) Federation to use in all International Athletics Competition. A seamless, water impermeable running track system having base layer with SBR (cast in-situ) that is being entirely adhered to the asphalt base by means of a specially developed polyurethane adhesive and SBR Granules. Consumption rate over dense asphalt are 7.0 killogram per square metre for SBR and 1.45 killogram per square metre of Polyurethane Binder. Priming over asphlat should be at 0.20 killogram per square metre, Polyurethane material for wear layer to be used 2.3 killogram per square metre of polyurethane. Product should be tested and certified as per IAAF & EN-14877 Norms. Track should have a overall thickness of 14.5 millimetre (+/- 4 % max tolerance) with the 11 mm of the Base layer and 3 millimetre of wear layer. Manufacturer should be from Europe (No Asian / Turkey) and his products should have been used for European Championships. Surface average technical standards should include 0.86 Mega Pascal per millimetre Tensile Strength, 77 % Elongation at Break, 41 % Force Reduction at 39.60C, 1.8 millimetre Vertical Deformation at 39.60C, should be Spike resistance, Average friction value of system should be 65. Wear coat to be applied “wet-in-wet” and homogeneous. EPDM granules are to be broadcasted into wet polyurethane wear coat. Supply rate should be 3.6 killogram per square metre. Excess EPDM is to be removed after polyurethane wear coat is cured (this excess quantity is returnable to supplier). EPDM content in wearing surface after removal of excess granules should be 2.8 killogram per square metre net. Physical properties of applied system in compliance with test report. Normal Stress Areas with a minimum thickness of 14.5 millimetre of finished track surface.
Providing and installing IAAF Approved Field Equipment's DISCUS THROWING CIRCLE -ALUMINIUM (Aluminium Discus Circle made of heavy duty aluminium. This can be folded in 2 parts for easy transportation. IAAF Certified)
DISCUS THROWING CAGE (Pole vault inlay and cover (Made of heavy duty 92 millimetre Square Steel Tube, HOT GALVANIZED for long life. Poles can be detached from centre for easy transportation and hinged for easy lifting during installation. All poles are bound together with the help of tie bars for sturdiness of the cage. Machine knitted 5 millimetre thick net with square mesh of size 40 millimetre. Net is Ultra Voilet stabilized for long life. Steel tube is used on the top of the net to avoid sagging. Cage with Netting, IAAF Certified)
HAMMER THROWING CIRCLE - ALUMINIUM (Made of thick Aluminium alloy in angle type construction. Constructed in two halves. Best quality nickel plated hardware used for assembling the unit. Easy to assemble and can be folded very easily for convenient transportation and storage. IAAF Certified )
DISCUS AND HAMMER THROWING CAGE (Made of heavy duty 100 millimetre Square Steel Tube, HOT GALVANIZED for long life. Poles can be detached from centre for easy transportation and hinged for easy lifting during installation. easy to bind the poles together with the help of tie bars for sturdiness of the cage. Gates are attached to the poles using four hinges and both gates include wheels for easy movement. NET is 5 millimetre thick ( Machine Knitted ) with 40 millimetre square mesh. Net is Ultra Voilet stabilized for long life. Steel tube is used on the top of the net to avoid sagging. IAAF Certified Cage with Netting)
SHOT PUT THROWING CIRCLE - ALUMINIUM (Made of thick Aluminium alloy in angle type construction. Constructed in two halves. Best quality nickel plated hardware used for assembling the unit. Easy to assemble and can be folded very easily for convenient transportation & storage. IAAF Certified)
Take-off Board System (Latest design take-off board system, made of solid wood. Welded aluminium tray protects take-off area and facilitates easy replacements of take-off board and plasticine board. Comes with heavy construction aluminium blanking lid for durability. IAAF Certified )
Triple Jump Take-off Board System (Stop board made of fibre designed for depressed pad. IAAF Certified)
Fibre Stop Board - Competition (Stop board made of fibre designed for depressed pad. IAAF Certified)
Water Barriers (Heavy duty foldable beam made square Pipe inside & covered with thick Water proof solid plywood. Base legs and base made of steel square pipe with spring loaded snap lock system for easy adjustment of three different required heights. 762 millimetre, 838 millimetre, 914 millimetre Legs are fitted into sockets grouted in to the ground. Painted with premium quality Poly urethane paint for longer life and durability. Easy to install & foldable to transport. IAAF Certified)
Pole Vault Box - Competition (Welded stainless steel construction. Comes with blanking board made of aluminium. Sockets at bottom for drainage of water. IAAF Certified)
TRACK KERBING (Heavy gauge aluminium features a box profile top. Held in place by 10 millimetre tall ribbed feet. Raised 10 millimetre off the track surface for rapid drainage. Each section of kerbing is milled to allow easy drop in or removal of corresponding sections. Available in Raw or anodized finish. IAAF Certified)
Providing and erecting chain link fencing 1.6 Metre height with Galvanised Iron chain link of size 50 x 50 millimetre 8 guage thick and fixed 75 millimetre above Ground level on vertical Mild Steel Angle of 40 x 40 x 6 millimetre size including excavating pits for foundation and embedded in Cement concrete block of 1:4:8 mix of size 450 x 450 x 670 millimetre at 1.75 Metre Centre to Centre with iron bar 16 millimetre diametre as hold fast including welding link with angle frame at 30 centimetre centre to centre with nuts and bolts and horizontal Mild Steel Angles at top and bottom of 25 x 25 x 5 millimetre size and vertical Mild Steel flat 35 x 5 millimetre and 25 x 5 millimetre horizontal including cross support of 40 x 40 x 6 millimetre Angles both sides at every comer or bends embedded in concrete blocks of 1:4:8 of size 450 x 450 x 670 millimetre including 3 coats of oil painting etc. complete.
Providing and fixing mild steel grill gate with angle iron frame 65 millimetre x 65 millimetre x 10 millimetre with iron bars at 150 millimetre Center to Centre and diagonal flats as per the detailed drawing including hinges, pivot block locking arrangement, welding riveting and oil painting of three coats of approved shade Weight of gate 35 Kilogram per Squaremetre.
GARDEN SOIL : Supplying on site garden soil well sieved 90 % to pass through Indian Standard sieve of 10 millimetre size free from stones rubbish like dried grass roots and other such materials. The soil should be fresh from quarry. The colour of the soil generally be red.The soil will be measured by measuring box. (Farma). Item includes royalty charges. Transporting loading and unloading etc. (lead charges per 20 killometre considered)
Preparing Instant Lawn: - Excavating the ground to a required depth of 20 centimetres, removing and conveying unwanted stuff to a required distance as directed. Filling fresh garden soil / silt and manure in excavated area in 3:1 proportion to a height of 20 centmetres. Mixing garden soil and manure thoroughly well, leveling, with required slope light watering on previous night. Planting required variety of lawn grass as directed and maintaining till well established by watering, weeding, clipping, rolling etc. complete.
Construction of various play courts (i.e. Volley ball, Kho-kho, Kabbade, etc.) as per detailed drawing and direction of Engineer in Charge consisting of various layers i.e. 150 millimetre thick compacted Rubble Solling, 50 millimetre thick Hard Murum Layer, 100 millimetre Thick. 1 Layer of Brick on Edge including filling gaps in sinders of Brick Bats, 30 millimetre thick. loose 20 millimetre thick. compacted mother soil (Including 30 % Black Soil, 40 % Sand, 30 % Garden Soil, including screening in 6 millimetre jali and laying in layer by layer with rolling by light roller), including compacting and curing and even and well levelled surface to be given with wet lime marking and all other relevent details as per above said norms etc. complete
Supply and Installation of having thickness of 6 millimetre comprising of 4 millimetre Prefabricated SBR Mat followed by 2 millimetre Polyurethane Coatings. Seamless, non-porous and smooth surface for Very good resiliency for comfort, injury prevention, Sustainability through high content of recycled and renewable raw materials in combination with lasting performance through very good mechanical strength, wear resistance and easy maintenance, repair and resurface procedures. System consist of SBR Matt being laid using two component Polyurethane Adhesive followed by Sealer to fill in all the pores of SBR mat, 2 coats of Polyurethane Resin Layer followed by Top Polyurethane Coat and game line marking etc comple and as directed by engineer in charg.
Providing and fixing Ductile iron manhole cover of light/medium/heavy duty with frame of any size over inspection chamber etc. complete (Prior permission of Superintendent Engineeer is to be obtained before inclusion of this item in the estimate)
Supplying and erecting LT CT multifunction DLMS compliance energy meter of accuracy of class 0.5 , 3x240V,50 Hz with optical & RS 232 port, backlit LCD, measure & display trivector energy, load survey, TOD, tamper detection & logging, power ON /OFF events, instantaneous parameters of rating 1/5 A with display in absence of power complete with zero adjustment & test certificate from manufacturer erected on provided M.S. box and connected to CTs.
Supplying , erecting & terminating XLPE insulated, galvanised steel formed wire armoured (strip) cable 11 kV(UE), 3 x 95 sq. mm. aluminium conductor laid in provided trench / pipe as per specification no. CB-HT
Supplying & laying (including excavation) half round reinforced cement concrete pipe of IS 458:2003 NP-2 class of 150 mm internal diameter in proper line, level and slope including providing and fixing collars in cement mortar 1:2 and curing etc. complete.
Providing and erecting Heat shrinkable indoor termination kit for 11 kV ( E ) XLPE HT cable 3x up to 95 sq. mm. with necessary material as per specification no. CB-JT/HT
Supplying & erecting inline D. P. Structure for 11/0.415 kV, 100 kVA Transformer with R.S.J. Pole 2 Nos. of size 100 x 116 mm x 11 Mtr. Long with suitable Distribution Box of C.R.C.A. Sheet 16 SWG with 4 Pole MCCB 200 Amps as incomer & 6 Nos. 100 Amps Kitkat / MCCB for out going circuits. Transformer D.P. Structure includes the A. B. Switch 200 Amps, D.O. fuse Set & L.A. Set. 2 Nos. of Top channel of size 100 mmx 50 mm for erection of A.B. Switch & 2 Nos. Base channel of size 100 mm x 50 mm for erecting Transformer Channel of size 75 x40 mm for erecting D.O. Fuse Set, L.A., A.B. Switch handle etc. Angle of size 50 x 50 x6 mm for erecting Distribution Box , Transformer Belt etc.as per drawing (min. 124 Kg. iron work ) with necessary clamps, Nut-bolts. V cross arm, top clip, insulators etc. complete with caution board & barbed wire, D.P. Structure shall be erected in c.c. foundation complete
Supplying and erecting G.I. stay set for poles, including loop insulators at inaccessible height with anchor plate 300x300x6 mm., straining screws, G.l. stay wire 7/8 SWG, G.l. stay rod 20mmx1.8m length and pole clamps duly erected in provided cement concrete foundation complete.
Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curing and finishing complete.(for stay).
Supplying & erecting G.I. pipe ‘A’ class 75 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE
Providing printed instruction chart for treating persons suffering from electric shock, printed in English & Marathi and duly laminated complete.
Providing pair of duly tested rubber hand gloves as per IS :47705 suitable for working up to 22 kV supply complete.
Supplying and fixing PVC synthetic elastomer electrically insulating mat with class A insulation conforming to IS: 15652 – 2006 having 2 mm thickness up to 3.3 kV
Supplying, installing, testing & commissioning 3 phase, 22/0.433 kV, 50 Hz., 100 kVA, Mineral oil immersed and naturally cooled outdoor type, aluminium wound Non-sealed transformer delta/star connected with additional neutral brought out on load side, temperature rise should not exceed 40℃ by thermometer in oil and 45℃ by the resistance method in winding at full load rating, with HV tapping (with off load tap changer) off load +2.5 to -5 in steps of 2.5%, having 4 number of tap positions, with standard accessories complete with test certificate with losses below 499 Watts at 50% load, 1733 Watts at 100% load as per IS:1180(part 1) : 2014 with necessary permissions of Electrical Inspector, as per specification no SS- TR-NSL.
Supplying, erecting, testing and commissioning of diesel generating set with alternator of 40 kVA output continuous rating, 3 Phase, 415 V, 50c/s 0.8 p. f. A.C supply, a totally enclosed air cooled / liquid cooled multi-cylinder diesel engine developing suitable BHP at 1500 rpm with 10% overload for 1 hour in 12 hours, along with standard accessories, self-excited self-regulated, screen protected alternator with static excitation system running at 1500 RPM as per IS 4722-2001 with voltage regulation +/- 5 %, with performance class G2 and maximum fuel consumption 7.47 Ltr/hr @75% loading. Both the engine and alternator direct coupled on a common fabricated steel base frame and mounted on anti-vibrating pads with standard control panel comprising meters, switchgears, indicators connected with suitable wires/cables, the complete set enclosed in composite Acoustic enclosure as fully assembled integral unit made of 16 SWG CRCA Sheet, sound absorbing material to restrict sound level up to 75 dB at 1.0 m, provided with first filling of oil, diesel not less than 75 Ltr etc. on provided M20 Grade CC Foundation as per specification no. GEN-DG
Supplying, erecting, testing and commissioning of microprocessor based AMF panel suitable for diesel generating set of above 35 kVA up to 40 kVA capacity Three phase, 415 Volts, 50Hz A.C. with all standard features, safeties etc as per specification no. GEN-AMF. (WITH NOTE OF 10% REDUCTION IN CASE OF NEW DG)
Making cement concrete foundation in 1:2:4 cement concrete with foundation bolts and nuts complete. (cost of wooden box is included) (for pumps).(3.4*1.9)
Excavating hard Rock or bituminous road by chiselling for preparing pit for pole / stay/earth plate / for laying cable/ pipe & clearing the site by removing debris & making the site as required complete.(3.4*1.9*0.3)
Supplying and erecting fencing of section having size 2450 mm in height from ground level and 1200 mm width with angle iron frame work erected in CC foundation and painted complete as per specification no SS-AS/FSG
Supplying and erecting double leaf hinged door each 1500 mm in width x 1850 mm in height using B class, GI pipe with angle iron supports, chain link wire mesh (jali) complete supported on channel iron, erected in foundation, and painted complete as per specification no SS-AS/DLD
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP.
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Supplying and erecting triple pole mini feeder pillar with 500V, 200A FPMCCB as incomer and 2 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket having IP54,IK10 protection and slanting top to be erected on provided foundation complete as per specification no. SW-SWR/MFP
Supplying and erecting triple pole mini feeder pillar with 500V, 300A FPMCCB as incomer and 3 outgoing circuits with HRC fuse base and cartridge of 100A with aluminium bus bar erected in 14 SWG CRCA sheet box with supporting angles, self locks, gasket having IP54,IK10 protection and slanting top to be erected on provided foundation as per specification no. SW-SWR/MFP
Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 32A TPN MCB incomer, 24hr astronomical time switch with minimum 5 years battery backup, IP 54 and IK10 protection, 25 A TP contactor for automatic switching of luminaires, 2 no. 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box with supporting angles, self lock, gasket and slanting top erected on CC foundation complete.
Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S 355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade as per IS-2062, pole made in single section & submerge arc welded, with lowering & raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 construction 5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm. flexible copper cable with lantern carriage assembly suitable for max. 12 nos. luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test report of high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no. OH-PL/HM (excluding luminaries)
Providing & erecting 7 m high (clear height) galvanised octagonal pole with foundation bolts having bottom of 130 mm A/F, top 70 mm A/F on provided foundation as per specification no. OH-PL/OPL
Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast).
Providing and erecting galvanised 1000mm double arm sword type bracket with FRP dome and ball as per specification no. OH-PL/PBKT
Making M- 20 grade reinforced cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq.m at 1.5 m depth including supply of steel, concrete, excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 6m to 8m high octagonal /conical GI pole).
Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 120 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½core 240 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3½ core 95 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and erecting metal work in CRCA sheet including Iron work for supports with fabrication of boxes, panel boards, etc. including cutting, bending, drilling, welding, riveting, treated with anti-rust treatment and duly powder coated or painted with one coat of red lead paint and 2 coats of enamel paint complete.
Supplying, erecting & marking SPMCB 0.5A to 5A, C-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying and erecting PVC insulated PVC round sheathed 4 sq.mm (56 no. x 0.30 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting PVC insulated PVC round sheathed 2.5 sq.mm (50 no. x 0.25 mm dia.) 3 core flexible multi stranded copper Industrial cable for voltage grade up to 1.1 kV
Supplying and erecting integrated LED flood light fitting Max. 50W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 5000 Lumens, min. efficacy of 100 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting integrated LED street light fitting 70-75W IP65 & IK08 class having single piece pressure die-cast aluminium housing, having system lumens output of Min. 7700 Lumens, min. efficacy of 110 lumen/W, CRI>70, CCT upto 6500K,THD<10%, p.f. >0.95, operating range of 140-270V, inbuilt surge protection of 10 kV, Life class of 50,000 Hrs. at L70B50, including driver complete with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting integrated LED flood light fitting Max. 155W IP65 & IK07 class having pressure die-cast aluminium housing, having system lumens output of Min. 18600 Lumens, min. efficacy of 120 lumen/W, CRI>70, CCT upto 6500K, THD<10%, p.f. >0.90, operating range of 140-270V, inbuilt surge protection of 4 kV, Life class of 50,000 Hrs. at L70B50, including driver with U shaped bracket with 3 Years warranty as per specification No FG-ODF/FLS2.
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and laying HMS PVC conduit FRLS grade 25 mm dia with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying & laying HMS PVC conduit 32 mm dia. with necessary accessories in RCC work/false ceiling/false flooring as per specification No. WG-MA/CC.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW(WITH NOTE 3)
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(WITH NOTE 3)
Supplying and erecting mains with 2x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x4 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(WITH NOTE 3)
Point Wiring Supplying and erecting ISI mark modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type switch 16A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6A multi sockets with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type 3 pin 6 / 16A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type (two module) electronic step regulator for fan, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting ISI mark modular type blanking plate one module, duly erected on provided plate & box.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 2 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 3 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 8 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Supplying and erecting unbreakable concealed type modular switch box with double mounting plate for 12 module duly erected flush to wall with required chiselling and finishing with cement mortar / POP as per required to match the background.
Point wiring for light/bell concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW
Point wiring for ceiling fan concealed type in min 20 mm FRLS grade HMS PVC conduit with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/CW
Point wiring for light/bell hybrid type (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WGPW/HW
Point wiring for ceiling fan (Surface type under false ceiling and concealed type for drops & switch boards on walls) in min 20 mm PVC conduit / casing n capping with 1.5 sq.mm. (2+1E) FRLSH grade copper wires, modular type switch, earthing and required accessories as per specification No: WG-PW/HW
Wiring for plug on board with Switch socket surface/concealed type, copper wiring and earthing and with modular accessories as per specification No: WGPW/CW
Supplying and erecting fan clamp of 30 x 5 mm. M.S. flat of required length and 10 mm. M.S. bolt and nuts erected with necessary hook of 10 mm. M.S. round bar and painted.
Supplying and erecting fan hook box of 10 mm M.S. round bar bounded to the R.C.C. bars upto 50 mm length each side and pierced through a 16 S.W.G. thick aluminium/M.S. Bowl 100 mm dia.or equivalent square size and having depth upto 75 mm complete erected with duly painted by one coat of red oxide paint and two coats of paint erected in position and without any leakage of slurry of cement concrete on either side of the box and positioned to the bottom level of the slab.
Supplying and erecting ‘B’ grade G.I. pipe / M.S. pipe down rod duly painted for fan complete erected with PVC three core flexible cable 1 sq. mm copper PVC wire.
Light Fittings & Fans Supplying and erecting LED square / circular Max. 7W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 770 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips omplete with 3 years warranty.
Supplying and erecting LED square / circular Max. 18 W down lighter/ Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2000 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting LED square / circular Max. 25 W down lighter/Panel Light having pressure die-cast aluminium housing, polystyrene diffuser having system lumens output of Min. 2750 Lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., max. ripple of 5%, THD<10%, p.f. >0.95, operating range of 120-270V, surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, having mounting arrangement with board for surface type or spring loaded mounting clips complete with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage / mirror light LED fitting (2 feet) Max. 12W with high transitivity diffuser with min. system lumens output of 1200 lumens, min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying and erecting anodized aluminium corridor / passage light LED fitting (4 feet) Max. 22W with high transitivity diffuser with system lumens output of Min.2200 lumens , min. efficacy of 100 lumen/W, CRI>80, CCT upto 6000K, Beam Angle of 110 deg., Ripple<5%, THD<10%, p.f. >0.95, operating range of 200-270V, surge protection of 2 kV, Life class of 50,000 Hrs. at L70B50, including driver, with end caps on provided PVC Block / wooden board with 3 years warranty.
Supplying & erecting inverter LED batten 20W tube light fitting with polycarbonate housing, heat sink, integrated HF electronic driver, Min. 2600 mAh Lithium ion Battery with charging time of 8-10 Hours and backup time of Min. 3 hrs. with minimum 25% of initial Watts having luminous efficacy of 100 lumen/watt, CRI>80, CCT of 6500K and THD<=20% having useful life of minimum 25000 hrs. with overheating protection with 2 years warranty.
Supplying and erecting fresh air cum exhaust fan of light duty250 V A.C. 50 cycles 225mm. 1400 RPM rust proof body & blades, wire mesh, duly erected in an approved manner
Supplying and erecting energy saving ceiling fan 230 V A.C. 50 cycles 1200 mm complete erected in position as per specification no. FG-FN/CF
WATER COOLER and UPS Supplying, erecting, testing and commissioning self contained water cooler 230/250V 50Hz nominal cooling capacity of 80 litres per hour and storage capacity 120 litres with partially stainless steel body as per specification no. AP-WCR/WC
Supplying and erecting ultra violet storage type water purifier (RO+UV+UF) with softener for safe drinking water consisting of UV germicidal tube of 8W capacity choke made of copper wire and two indicator lamps with output of purified water minimum 0.33 litre/min with activated carbon filter and softener operating on 230V, single phase A.C. supply with UV fail & filter change indication system .(for TDS more than 200)
Distribution Boards with RCCB, MCB & MCCB Supplying, erecting & marking SPMCB 6A to 32A, C-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking SPMCB 6A to 32A, B-series with rated short -circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking TPMCB 40A to 63A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying & erecting triple pole and neutral distribution board (TPNDB) with door surface/ flush mounted SPMCB of 12 poles, on iron /GI frame (horizontal busbar type) as per specification no. SW-SWR/MCBDB
Supplying & erecting triple pole and neutral distribution board (TPNDB), SP/TP MCBs total 4 ways /12 Poles, with door, 1.2mm thickness surface/flush mounted, IP 43 Protection on iron/GI frame (vertical busbar type) as per specification no. SW-SWR/MCBDB
Supplying and erecting single pole and neutral distribution board (SPNDB), with 2 ways for incoming and 6 ways (6 poles) for outgoing SP MCBs, with door, 1.2mm thickness surface / flush mounted, IP 43 Protection on iron / GI frame as per specification no. SW-SWR/MCBDB
Supplying and erecting single pole and neutral distribution board (SPNDB) with door surface/flush mounted with 2 poles for incoming and 10 poles for outgoing SP MCB’s on iron/ GI frame as per specification no. SW- SWR/MCBDB
Providing, erecting and commissioning 2 pole RCCB only of electromagnetic type with 30/100/300 mA sensitivity and having capacity of 16/ 25A complete as per specification no. SW-RCCB/RCCB
Supplying, erecting & commissioning 4 pole RCCB 16/25A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, fixing and commissioning 2 pole, RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
LT Cables and End Termination Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 2.5 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 6 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 16 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
CABLE TRAY Providing & erecting hot dipped galvanised ladder type cable tray manufactured from 16 SWG (1.6 mm thick) GI sheet of 150 mm width & 75 mm height complete with necessary coupler plates & hardware.
EARTHING SCHEDULE Providng earthing with galvanized iron earth plate size 60 x 60 x 0.6 cm complete with all materials, testing & recording the results as per specification no. EA-EP
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP.
Supplying & erecting conventional spike type air termination suitable to carry lightning stroke made up of heavy gauge 40 mm dia copper pipe of standard length with 5 Nos. copper spikes fixed on copper ball as air terminals duly threaded in copper pipe erected on provided foundation complete.
Supplying and erecting GI strip of high purity required size used for earthing on wall and/or any other purpose with necessary GI clamps fixed on wall painted with bituminous paint with joints required. As per specification no EA-EP. (25X3mm=450m X 0.8Kg/mtr = 360 Kg)
Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI
Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority.
Net Working Section Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 32 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying and fixing 24 port patch panel with tool-less keystone jacks in provided U Rack complete as per specification no. WG-NAS/PP
Supplying and fixing 2 m UTP patch cord of cat 6 type in position as per specification No. WG-COC/PC
Supplying, fixing, and configuring 24 ports, POE switch in provided rack as per specification No. WG-NWC/ENS
Supplying and fixing tool-less IO (Ethernet) flush/surface type in provided modular box as per specification no. WG-NAS/IO
Supplying, fixing, and configuring broadband ADSL router with all accessories, on provided rack as per specification No. WG-NWC/ADSL
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
Supplying and erecting 12V/42Ah SMF battery with battery terminal wire, duly charged with 24 months warranty complete
Supplying, erecting, testing and commissioning of 3kVA capacity online pure sine wave with backup time of ....... hrs. PWM & IGBT based UPS with 0.8 to unity output pf, single phase input & 1 phase output complete with all protections as per specification no. AP-UPS
Supplying and erecting HMS PVC conduit FRLS grade 25 mm dia. with necessary accessories in wall/floor with chiselling appropriately as per specification No: WG-MA/CC.
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW(WITH NOTE 3)
Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW
Supplying and erecting mains with 1x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places. as per specification No: WG-MA/BW(WITH NOTE 3)
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 4 module duly erected.
Supplying and erecting bulk head LED fitting max. 10W with high transitivity diffuser with system lumens output of min. 1100 lumens, min. efficacy of 110 lumen/W, CRI>80, CCT upto 6500K, Beam Angle of 120 deg., THD<10%, p.f. >0.95, operating range of 140-260V, in built surge protection of 2.5 kV, Life class of 50,000 Hrs. at L70B50, including driver, IP66, IK09 rated on provided PVC Block / wooden board with 3 years warranty.
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying, erecting & commissioning 2 pole RCCB 40A, electromagnetic type with 30/100/300 mA sensitivity with earth leakage trip indication complete as per specification no. SW-RCCB/RCCB
Supplying, fixing and commissioning 4 pole RCBO 63A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 2 core 4 sq mm copper conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 10 sq. mm. copper conductor complete erected with glands & lugs, on wall/ trusses/ pole or laid in provided trench/ pipe as per specification no. CB-LT/CU
Supplying, installation and testing of maintenance free earthing comprising of Electrode of 17.2 mm diameter Low Carbon Steel with 250 micron molecular copper bonded earthing rod of Length 3m along with 25 kg Carbon based environment friendly back fill ground enhancing compound required to fill up the excavated earth with required quantity complete, and recording the results Specification no. EA-MOBI
Supplying and erecting copper strip of high purity required size used for earthing on wall and/or any other purpose with necessary copper clamps fixed on wall painted with bituminous paint with joints required. As per specification no. EA-EP.
SITC of Electric Traction Passenger Lift with · Rated capacity :- 13 Passenger/884Kg · Floors :- G+ 2 floor (3 Stops/3 Landings) · Travel :- 8 mtrs. · Location of Lift Machine:- MR/MRL · Rated speed :- 1.0mps VS · Car/Landing door clear opening of 900 mm wide x 2000 mm high · Clear Car size of 1100 mm wide x 2000 mm deep x 2250mm high · Lift shaft available having clear size of 2500 mm wide x 2000 mm deep, 1500 mm Pit depth, 4200 mm Overhead. · Doors type :- COPO/TOPO Doors with frame made from SS 304 grade solid(non-cladded) sheet of 1.5mm thick in hairline finish for car and all landing doors with SS door architraves/frames The lift doors shall have minimum 1 hour fire rating (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory). · Lift car enclosure made from SS 304 grade solid (non-cladded) sheet of 1.5mm, thick with hairline finish with frame made from MS girders, bracing of adequate size with minimum safety factor of 5, with Toe Guard Apron, with necessary false ceiling with adequate LED lights, blower/fan for ventilation & SS chequered plate flooring, handrails, mirror, emergency light etc. The lift car interior design shall be done as per the directions of engineer in charge. · COP with SS face plate having metallic push buttons with Braille code & luminous indicator around button with FPI, scrolling UP/DN LED indicator & with / without attendant key switch, OWD with audio-visual alarm, VAS in Marathi, Hindi & English with intercom system with telephone instrument in Lift car, LMR & FCC/ground floor. · LOP with SS face plate having recess/surface push button box for all landings with scrolling UP/DN LED indicator having metallic push buttons with Braille code & luminous indicator around button with CPI, Lift car arrival & next travel direction audio-visual indication at all landings. · Lift controller based on microprocessor/ PLC with VVVF Drive having closed loop control system, with IBMS compatible having necessary port. The controller shall have necessary protections such as overcurrent, overvoltage, over speed, overheat for all devices including lift motor and travel direction protection, protection for phase loss at input or output etc. various operation modes such as maintenance, change direction by attendant, full load bypass, VIP call operation, self levelling operation, call cancel facility, auto return to home landing, fireman evacuation operation, earthquake operation, door open/close operation from COP etc. The system can record information for minimum 30 latest faults, with real-time clock management and handheld keypad with LCD screen for view and setting of parameters, The control panel duly wired with proper size & strength, copper wire for power & control circuit, with provision for addition of floor/control card & allied accessories control panel having enclosure of 1.5mm CRCA sheet with powder coating with IP54 Protection class. · ARD complete with necessary SMF VRLA batteries. · Fireman controller having fireman switch at fire Landing. · CCTV surveillance system comprises of 2 nos minimum 2.0MP FHD IP based vandal proof Dome camera in lift car & in LMR/inside lift shaft top aimed on Lift machinery & controller with NVR kept in LMR/FCC with HDR data backup for min. 90 days with min. 18” FHD TV monitor, to be kept in FCC/LMR as directed by Engineer In Charge. · Lift Machine of Gearless PMSM of suitable kW with duty cycle of minimum 120 starts/hr (with submission of necessary valid test certificate issued by NABL accredited or Independent test laboratory), with Traction pulley, OSG, electromagnetic brakes, entire assembly mounted on adequate size girders duly fixed on LMR floor/ shaft walls complete with main/diverter traction sheaves, suspension wire ropes/belts of adequate size & strength. · Other mechanical parts such as 'T' section adequate size guide rails for car & counter weight with brackets fasteners, counter weight frame with necessary blocks, buffers with necessary support arrangement, MS pit ladder etc. erected with necessary steel work. · Minor civil work such as alteration work if any necessary for erection of landing door frames and it's accessories e.g. sill, header, hole pass etc complete with plaster finish, civil work for erection buffers, erection of lift machinery, adequate size core cuts if required & scaffolding for erecting guide rails, providing and fixing steel girders/RCC work having adequate strength for mounting and hoisting lift machine etc. complete as per specification no. LFT. · General: - Job includes entire procedure of obtaining all necessary erection permissions & "License to Work the Lift" from Electrical Inspector(Lifts) with submission to the Engineer In Charge. · The above rate includes Fully Comprehensive AMC for one year from the date of commissioning. For Full Collective control system, add as below. For Lift travelling above First floor & up to Sixth floor
For additional 2MP Camera along with necessary accessories at Home Landing, add as given.
For Lift having 900mm wide x 2000mm high clear entrance in 1.5mm thick SS 304 grade solid(non-cladded) landing door [Two panel], this includes all necessary accessories like LOP's with UP/DN buttons-arrows-indicators, extension of guide rails, shaft wiring with trunking, travelling cables, main hoisting ropes/belts, & OSG rope landing doors with all accessories etc. necessary for the normal safe functioning of lift installation complete.
Supplying, erecting & marking TPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, erecting & marking FPMCB 6A to 32A, with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-SWR/MCB
Supplying, fixing and commissioning MCB type change over switch 2 pole, 25 A with 3 positions (I-O-II) with centre off position as per specification no. SW-SWR / MCBCOS
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying and erecting bus bar chamber triple pole with neutral with four aluminium bars, 500V, 100A having 15mm (Width) X 3 mm (Thickness), with 99.9 % aluminium purity as per E91E Grade & Current Density 0.8 A per sq. mm. compliance to IS 5082 and Enclosure fabricated with 16 SWG CRCA sheet and epoxy paint, with suitable number of ways and with SMC/DMC Insulators and accessories of suitable rating complete as per specification no. CP-BB
Supplying and erecting 525 V 3 phase, 50 Hz., MPP type capacitor having minimum overcurrent capacity of 1.8 In, peak inrush current capacity 300 In and minimum life 150000 hours kVAr bank of metalised polypropylene condensers (MPP) with the standard capacities of 2, 3, 5, 7, 10, 12.5 and 15 kVAr units of P.F. correction for operation on 3 phase 50 Hz. with externally discharging resistances, earthing terminals and built on angle iron or channel iron frame work and provided with terminal cover box complete erected on provided iron bracket or on floor duly tested by licensee.
Supplying and erecting marine (Waterproof) plywood 18/19 mm thick fixed to wall or on provided panel board with necessary materials such as screws, wall fasteners, supports, nut bolts etc. complete with compliance to IS 720:2010
Supplying and erecting minimum Three & above star rated submersible pump set of 2.25 KW/3 HP with 415 V, 50 c/s AC supply suitable for 150 mm dia. borewell suitable for 120 to 390 LPM discharge at 55 to 11 m head & discharge & delivery Pipe of Size-50mm diameter with a necessary H type clamps as per specification No. WP-SMP
Supplying and erecting minimum Three & above star rated submersible pump set suitable for erection on open well of 2.25 KW/3 HP with 415 V 50 c/s. A.C. supply, having delivery head from 27 to 9 m and discharge from 300 to 660 litres. per minute & pipe of Suction 65mm /Delivery 50 mm diameter erected with necessary H type clamps as per specification No. WP-OSP
Supplying & erecting flat flexible 3 core 4 sq.mm PVC sheathed submersible type copper cable suitably clamped at fixed intervals with column pipe assembly complete.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 4 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying & erecting Water level controller 230/415 V, A.C. , Four way under ground & Over head tank operation only.
Supplying & erecting PVC coated 5 mm dia. Brass sensor/ electrode duly wired with nuts & bolts complete (Set of 3 Nos)
Supplying & erecting automatic control panel for 3 Phase , 415 volt, A.C, Submersible/centrifugal pump set up to 7.5 HP consisting of DOL starter having relay range 9-14 AMP,S.P.P., Combined ammeter/ voltmeter, phase indicating lamp enclosed in CRCA powder coated Vibration proof enclosure with IP 54 protection. Control Panel should offer single phasing, phase reversal, phase imbalance etc .
Supplying, installing, testing and commissioning FR, XLPE armoured cable 2 core 1.5 sq.mm. copper conductor complete erected on wall/ ceiling complete as per specification no. CB-LT/CU
Supplying and erecting high density polythene pipe ISI mark 50 mm. dia. suitable for pressure of 6 kg. / cm2 connected to jet/submersible pump with required material complete.
Supplying and erecting non return valve 50 mm dia in position made of gun metal complete.
Supplying and erecting 50 mm dia. gun metal sluice valve at position with necessary materials complete.
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.0TR to 1.2TR capacity having ISEER minimum 5.00 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.7TR to 2.0TR capacity having ISEER minimum 3.8 to maximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32 having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC
Supplying, installing, testing & commissioning split type room air conditioning unit 2.5TR to 2.7TR capacity with refrigerant R32 415V, 50 Hz, A.C. supply having 1 no of air handling unit (Mega split) mounting type complete with temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. AP-AC/WAC
Supplying, fixing and commissioning 2 pole, RCBO 6/10/16/20/25A, with overcurrent, rated short-circuit breaking capacity (10 kA) and earth leakage protection, with 30/100/300 mA sensitivity and short circuit and earth leakage trip indication as per specification no SW-RCCB/RCBO
Supplying & erecting CRCA sheet metal one way enclosures of 1.2mm thickness suitable for DP MCB /TP MCB/FP MCB/RCCB/RCBO complete erected on angle iron/GI frame.
Supplying 16 amp. 3 pin plug Top bakelite type of 230 V. A.C. supply.
Supplying and erecting PVC trunking (PVC casing-n-capping) of size 25 mm with accessories on wall/ceiling as per specification No: WG-MA/CON.
Supplying and erecting mains with 1x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW (WITH NOTE 3)
Supplying and erecting mains with 2x1.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit/trunking/inside pole/Bus bars or any other places as per specification No: WG-MA/BW
Supplying and erecting modular type switch 6A / 10A duly erected on provided plate and box with wiring connections complete.
Supplying and erecting modular type 3 pin 6A multi socket with safety shutter, duly erected on provided plate and box with wiring connections complete.
Supplying and erecting PVC Surface modular switch box with double mounting plate for 3 module duly erected.
Supplying and erecting 3m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19 pin HDMI connectors complete.
Supplying and installing cat-6 cable suitable for networking as per specification no. WG-COC/NC
Supplying and installing cat-6 armoured cable with ECCS tape suitable for networking as per specification No. WG-COC/NC
Supplying, fixing, and configuring 8-ports 1 G unmanaged gigabit POE switch erected in provided rack complete.
Supplying, installing and testing UTP connector (RJ-45) as per specification No. WG-NAS/UTPC.
Supplying and fixing 6U wall mount rack (Dimension-DxWxH – 500x600x367 mm) as per specification No. WG-NAS/RAK
Supplying, installing, testing and commissioning of single phase, 230V, 50 Hz, 1400 to 1600VA digital pure sine wave inverter with backup time of ........ hrs. based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV
Supplying and erecting 12V/150Ah tubular battery with battery terminal wire, duly charged with 36 months warranty complete.
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 2.5 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying, erecting & terminating FR XLPE insulated, galvanised steel formed wire armoured (strip) cable 1100 V, 3 core 4 sq. mm. aluminium conductor complete erected with glands & lugs, on wall/ trusses/pole or laid in provided trench/ pipe as per specification no. CB-LT/AL
Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, to required depth complete.
Supplying and erecting Supply installation and commi-ssioning of 43" full 4k Full HD commercial 4K Led Display monitor /42 inches or higher full HD VGA DVI HDMI LAN USB RGB RS 232C IN / OUT AV IN COMPONENT IN AUDIO IN/OUT WIFI READY SPEAKERS Make- Sony (NON CSR Sanctioned by S.E. MREC Mumbai Letter No.583 Dt.22/02/2022 Est.No.0618/2021-22 )
Supply and installation of 8TB surveillance storage Hard Disk Drive-24/7 Surveillance HDD capacity -8 TB interface - SATA III 6 Gb/s Max sustained Transfer Rate OD- 210 MB/s cache-256 MB Tamish Resistant load /unload cycles- 300 000 power on Hours/ year 8760 mean Time Between failures (MTBF) - 1 million hours operating Temperature- Ambient: 41 F/5 C(min) Drive case : 158 F/70C (max) Non operating Temperature Ambient : -40 F/ -40C (min). Make - Seagate (NON CSR Sanctioned by S.E. MREC Mumbai Letter No.583 Dt.22/02/2022 Est.No.0618/2021-22 )
Supplying and erecting Supplying erecting testing and commissioning of Dome/Bullet Type IP cameras: Max 4MP(2592 x 1520) resolution built in 2.8 mm fixed lens. Max 25fps @all <mailto: Max. 25fps@all resolutions>(H265/ H264) H265+ H264MUPEG codes supported multiple streaming video compression H265 H264 Image sensor 1/3 progressive scan CMOS illumination 0.5 lux (20 meter) image setting compression colour brightness sharpness contract white balance exposure conyrol backlitght compensation security password protection IP Address filtering user access Log opera-ting conditions10 to 55 C casing Tamper Resistant casing for indoor Envirounment IK08.a. sensor ½.9MP CMOS.1) pixels per Sensor 2000(H)x 1121(V) total 1984(H) x 1105 (V) effective 2)scanning : progressive 2.) Day/night setting : True Day & Night 3) Backlight ompensation(BLC) OFF/ON 4) WDR 120dB 5) Digital noise Reduction (DNR) on/off. 4) Number of multi stremming profiles: 3 maximum a. The 4 MP camera shall have onboard SD card storage MUPEG codec supported multiple streaming motion detection Tempering Defocus detection Audio mike inbuilt micro SD (128GB) memory slot POE/12v dc ir Viewable length 20m. IP 66 UK 10. LDC support (lence/Distortion correction Make- Hikvision(NON CSR Sanctioned by S.E.MREC Mumbai Letter No.583 Dt.22/02/2022 Est.No.0618/2021-22 )
Supplying and erecting G.I. pipe pole ‘B’ class 80 mm dia 6 m long with pole cap, base plate in provided foundation as per specification no. OH-PL/GIP
Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP
Making cement concrete foundation including excavation ( 45 x 45 x 120 ) cm deep in 1:3:6 cement concrete, 20 to 25 mm stone metal, (45 x 45 x 45) cm / 45 cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (for 6 m pole)
Supplying, installing, testing & commissioning of High defination 4 Megapixel IP IR PTZ Camera Minimum 1/3" Progressive Scan CMOS image sensor, Support H.265+/H.265/H.264 , Minimum 25fps@ 1520p (2688x1520) Focal Length 4.8 mm to 120 mm, ONVIF profile conformant, IR Distance: min. 150 m, WDR 120 dB, MicroSD/SDHC/SDXC card (256 GB), Support alarm triggering by specified target types (human and vehicle), Min IR distance :150M,minimum 4.8-125mm Lens min 16x digital zoom, min 30x optical Zoom. White light illuminator 60m; 133dB HDR, H.265+, H.265, H.264, MJPEG streams, Intelligent Dynamic Noise Reduction, BLC, White Balance, Pan Range 360° continuous, Tilt Range -90° to 5° (Auto-flip 190°), Pan/Tilt Modes - Pan: 0.1°/s - 240°/s; Tilt: 0.1°/s - 100°/s, Presets 256, Tours, Audio- 1/1 Channel In/Out, Micro SD card support up to 256, 32 individually configurable privacy masks, Alarm inputs/outputs - 2/1, Dual Power options, Any object, Object in field, Crossing line, Entering field, Leaving field, Loitering, Following route, Idle object, Removed object, Counter, Occupancy, Crowd detection, Condition change, Similarity search, Tampering, Object filters based on Duration, Size, Aspect ratio v/h, Speed, Direction, Color, Object classes (Upright persons, Bikes, Cars, Trucks), IP66 , IK10 ONVIF Profiles S & G & T, FCC, CE, UL Certified included with cameras. Including necessary Wall Mount Junction Box, Camera mounting accessories, Enclosure, bird guard etc. (With 5 Year Warranty)
Supplying and erecting Supplying erecting and commisioning of 16 channel professional series 4 k HD network video/ audio IP video input 16 ch Two way audio 1 ch RCA network bandwidth 320 MBPS (i/c&OG) remote user 128 protected p2p U pup NTP DHQ video remote user 128 protected p2p U pup NTP DHQ video Audio output HDMI/VGA 1920 x 1080p/ 60 Hz 280x720/60 12 MP/8MP/6MP/5MP/108 Recording resolution Op/960p/720p/p1/2CIF all Audio output LCH RCA 16ch play back corridor mode 3/4 /5/7/9/10/12/16/3 Deced format H265 h 264 Live view play back 12 MP/8MP/6MP/5MP/4MP/3MP @ 30 16x 1080P @30X Hard disk sata 4s interface upto 10 TB for each serial interface 1xR4585 USB front panel 1xusb 20 Rear panel 1 ALARM 08CH A08um out 4 ch power supply 12 V PC power consumption 12W(without 10cnt (+14 fat 131F) environment Dimentious humidity 590% RH (non condensing) 440 mmx 30 mm (17.3 x 13.5 x 2.0 ) (WXDXH) (weight without hdd)< 3.14 kg (6.9216) certification with three year warrenty CE FCC UL) mAKE- HIKVISION NON CSR SANCTIONED BY S.E. MREC MUMBAI LETTER NO. 583 DT 22/02/2022 est no. 0618/2021-22)
Harsh Constructions Pvt Ltd
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid