Loading…
Loading…
Tender Value
₹1.4 Cr
EMD Value
₹2.2 L
Closing Date
6 Apr 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
TENDER
17 conditions · 6 needing a document upload
Tenderer should submit their bank account no., name of the bank and bank specific code no. in separate sheet, Current valid GST registration no. and PAN CARD.
Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' shall be exempted from payment of Bid Security detailed above. 2. Labour Cooperative Societies shall submit only 50% of above Bid Security detailed above
The tenderer are advised to submit the Bid Security with the tender for the due performance with the stipulation to keep the offer open till such date as specified in the tender, under the conditions of tender. The Bid Security shall be deposited either in cash through e payment gateway or submitted as Bank Guarantee bond from a scheduled commercial bank of India or as mentioned in tender documents. The Bank Guarantee bond shall be as per Annexure-VIA and shall be valid for a period of 90days. beyond the bid validity period.
Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where V=Advertised value of the tender in crores of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. [As per GCC April 2022 Advance Correction Slip No. 1]
Tenderer should have valid electrical contractor license issued by Government Electrical License Board on or before closing date of tender, copy of which should be submitted along with the tender offer, otherwise tender would be summarily rejected.
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, or (iii)One similar work costing not less than the amount equal to 60% of advertised value of the tender. (b) (1)In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: (i)Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, or (ii)Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, or (iii)One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Note for b(1): Separate completed works of minimum required values shall also be considered for fulfilment of technical eligibility criteria for different components. similar nature of work (Supply, erection, testing and commissioning of 11KV & above substation work.)
30 conditions · 8 needing a document upload
Whether the bank account no., name of the bank and bank specific code no. in separate sheet submitted
Whether PAN Card details submitted in separate sheet.
Whether GSTIN number along with other necessary documents under GST Act (which is implemented w.e.f 01- 07- 17) submitted in separate sheet.
Whether document relevant to 1)Any firm recognized by Department of Industrial Policy and Promotion (DIPP) as 'Startups' certificate submitted in case of exemption from payment of earnest money deposit. 2) Labour Cooperative Societies certificate submitted in case of deposition of only 50% of Bid Security
Whether Document verification certificate Annexure V(A) is submitted as the case may be.
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
At Goshala - Improvement of 33/11 kV Goshala Substation and Upgradation of 11 kV Feeders.
DYCEE-PS-MLG-HQ-63-25-26
DYCEE-PS-MLG-HQ-63-25-26
Open
Works - General
180 Days
Kamrup, Assam
₹0
₹2.2 L
6 Apr 2026
13 Mar 2026
23 Mar 2026
Item- 1 Please see the item break up
S No. Item Description of Item Unit Qty Rate Amount
1 1 Carrying, Laying, commissioning of cable of Metre 19000.00 32.00 608000.00
various size XLPE cable, partly along the pole
and partly through ground in cable trench with
suitable fixing arrangement. Loading, unloading,
carrying of cable to actual work site by
contractor's own arrangement including supply
and commissioning with suitable size of Lugs as
per instruction of Engineer in-charge at site.
2 2 Excavation for cable trenches in soft soil, depth Metre 2800.00 622.00 1741600.00
upto 1.2 m including dressing of sides lift upto
1.5 m, including getting out the excavated soil,
refilling with sand and or good soil after laying
of cable/pipe etc in layers of 20 cm, ramming,
watering and disposal of surplus excavated soil
as directed, within a lead of 50 meters. As per
drawing no. PCEE/ELG/DRG/2024/2 dated
4.10.24 and as per direction of site Engineer in-
NFR HQ-ELECTRICAL/N F RLY
3 3 Dismantling of overhead HT line, complete with Each 80.00 1356.00 108480.00
HT conductors, cross arms, insulators, stay sets, Span
guys, brackets, clamps, hardware and poles
(PCC / steel / RSJ / rail poles) including cutting,
lowering to ground, removal of stays,
excavation around pole roots, dismantling of
pole from foundation, stacking of serviceable
materials at site as directed and disposal of
unserviceable materials within the premises,
complete as required.
4 4 Supply, erection of earthing set by Class"A" 50 Numbers 36.00 2218.00 79848.00
mm Dia GI pipe 3 Mts. long including
construction of earth pit with cover and earth
continuity by (25x3) mm GI strip , GI nuts and
bolts etc. as per direction at site Engineer and
as per PCEE office Drawing
no.PCEE/ELG/DRG/2024/1 dated 30.09.2024.
5 5 Design, fabrication,, supply, carrying and Numbers 32.00 25765.00 824480.00
erection of 12 mtr height swaged type (410-SP-
66) G.I. Tubular pole (including supply and fixing
of base plate and pole cap) by earth digging to
a depth of 1/6th of the pole height with CC
foundation in ratio 1:2:4 by cement ,sand and
stone of nominal size 20 mm & the size of the
CC block will be 30 cm dia with height upto the
pole depth below GL and 30 cm above GL for
muffing. The pole shall be hot dip galvanized
with an average coating thickness of 70 microns
conforming to IS: 2629/IS: 2633/IS: 4759. The
pole swaging, welding and base plate welding to
be done as per IS: 2713. The material
construction (pipe) shall confirm to IS: 1161/IS:
1239 and shall be able to withstand maximum
wind speed conforming to IS:875. Anti-climbing
device by barbed wire upto 2.5 mtr height with
necessary GI clamp/nut/bolts, etc has to be
provided. Danger Board of size 8"X6" fixed with
suitable GI clamp has to be provided showing
the voltage grade, skull etc. The whole work
shall be executed as per direction of Engineer in
6 6 Excavation of horizontal boring manually for Metre 180.00 766.00 137880.00
outside of the Road/ Railway track Embankment
at a minimum distance of 6 meters. From the
embankment GL and depth of 2.0 meters. Below
from G.L. with preparation of site for boring by
placing of pipes for electric cable protection
through contractor own arrangement as per
direction of site Engineer.
7 7 Supply, installation, and laying of G.I. pipe Metre 150.00 1627.00 244050.00
(medium class) of 150 mm (ID) with all
necessary accessories as per requirement at
diameter Double wall corrugated PN-6.0 Kgf/cm2
HDPE pipe partly through overground & partly
through underground including provision of
necessary socket etc. as per direction of site
Engineer in-charge of Railway
9 9 Supplying and fixing cable route marker with 10 Numbers 182.00 242.00 44044.00
cm X 10 cm X 5 mm thick G.I. plate with
inscription there on, bolted /welded to 35 mm X
35 mm X 6 mm angle iron, 60 cm long and
fixing the same in ground as required
10 10 Supply, fixing, testing and commissioning of HT Numbers 144.00 3575.00 514800.00
heat shrinkable type outdoor cable end
termination kit suitable for single core 11 KV
grade XLPE 120 sq.mm armoured cable
including all accessories for jointing 11 KV cable
to overhead through PG clamp as per direction
at site Engineer.
NFR HQ-ELECTRICAL/N F RLY
11 11 Supply, fixing, testing and commissioning of 11 Set 8.00 5151.00 41208.00
KV GO switch 400 Amps complete with
operating handle and fixing of necessary MS
channel.( 1 set consisting of 3 pieces )
12 12 Excavation of horizontal boring by HDD machine Metre 494.00 4149.00 2049606.00
for outside of the Road/Railway track
Embankment at a minimum distance of 6
meters. From the embankment GL and depth of
2.0 meters. Below from G.L. with preparation of
site for boring by placing of pipes for electric
cable protection through contractor own
arrangement for 200 mm dia hole as per
direction of site Engineer.
13 13 Supply&testing of outdoor type Vacuum Circuit Set 1.00 252629.00 252629.00
Breaker of rated voltage 36 KV, continuous
rated current 630 A, rated short Circuit Breaking
Current 25KA. Conforming to IS: 13118 (latest)
to be mounted on CC foundation, in the ratio
1:2:4 by cement, sand and chips of size 19 mm
and down and dimensions as per site
14 14 Supply & testing of outdoor type Vacuum Circuit Set 1.00 198562.00 198562.00
Breaker of rated voltage 12 KV, continuous
rated current 630 A, rated short Circuit Breaking
Current 25KA. Conforming to IS: 13118 (latest)
to be mounted on CC foundation, in the ratio
1:2:4 by cement, sand and chips of size 19 mm
and down and dimensions as per site
15 15 Supply and fixing of H.T. danger notice plate of Numbers 16.00 402.00 6432.00
250 mm X 200 mm, made of mild steel, at least
2 mm thick, and vitreous enameled white on
both sides, and with inscription in single red
colour on front side as required. As per DSOR
item No. 2.22 and direction of site engineer
16 16 Supply, Installation, Testing & Commissioning of Set 42.00 1567.00 65814.00
weather-proof cable junction box suitable for
outdoor installation, conforming to IP 66 / IP 69
protection class for outdoor installation, of
approximate size 130 x 130 x 77 (with
knockouts for cable entry & min 7 No of
terminals) complete in all respects as per
direction of site engineer.
17 17 Design, supply, fabrication Of refection of Numbers 550.00 1755.86 965723.00
Rectangular shape 900x600 mm precast R.C.C.
Cable trance/manhole cover with frame - L.D. -
2.5 as per DSOR item No. 7130
18 18 Providing and fixing chain link fabric fencing Sqm 450.00 1121.08 504486.00
made of G.I. wire of 4.0 mm diameter, mesh
size 50 mm x 50 mm, PVC coated to outer
diameter 5.0 mm, including weaving, stretching
and fixing with G.I. binding wire, clips, nuts,
bolts and all accessories, complete as per DSOR
Item No. 8696, in position over structural steel
work comprising tees, angles, channels and R.S.
joists, including cutting, hoisting, fixing in
position and applying one coat of red oxide zinc
chromate primer, complete as per DSOR Item
No. 1007, and including brick on edge flooring
with common burnt clay non-modular bricks of
class designation 7.5, laid on a 12 mm thick bed
of cement mortar 1:4 (1 cement : 4 coarse
sand), including filling the joints with the same
mortar, curing and all incidental works,
complete as per DSOR Item No. 11.1.1, and
directions of the Engineer-in-Charge.
19 19 Construction Substation floor concreating by CC cum 270.00 6490.60 1752462.00
foundation in ratio 1:1.5:3 by cement, sand and
stone chips respectively by observing the IE
rules including site preparation and as per
direction of Railway Engineer.
NFR HQ-ELECTRICAL/N F RLY
20 20 Supply, Installation, Testing & Commissioning of cum 90.00 2170.00 195300.00
40mm/50mm size pebbles Stone Aggregate
(Single size) : 40 mm nominal size cum As per
DSOR item No. 0293, Manual Labour including
loading, unloading and stacking for lead less
than 0.50 KM As per DSOR item No.1.2.6, Earth
work in surface excavation not exceeding 30 cm
in depth but exceeding 1.5 m in width as well as
10 sqm on plan including getting out and
disposal of excavated earth upto 50 m and lift
upto 1.5 m, as directed by Engineer-in- Charge:
As per DSOR item No.2.1.1
21 21 Earth work in excavation by mechanical means cum 82.00 307.00 25174.00
(Hydraulic excavator) / manual means in
foundation trenches or drains (not exceeding
1.5 m in width or 10 sqm on plan), including
dressing of sides and ramming of bottoms, for
all lift, including getting out the excavated soil
and disposal of surplus excavated soil as
directed, within a lead of 50 m. As per DSOR
Item No. 2.8.1 and direction of site engineer
22 22 Providing and laying in position cement cum 12.21 8619.00 105237.99
concrete of specified grade excluding the cost of
centering and shuttering. 1:3:6 (1 Cement : 3
coarse sand (zone-III) derived from natural
sources : 6 graded stone aggregate 20 mm
nominal size derived from natural sources) As
per DSOR item No. 4.1.5 and direction of site
23 23 Brick work with common burnt clay F.P.S. (non cum 32.00 8709.00 278688.00
modular) bricks of class designation 7.5 in
foundation and plinth in: Cement mortar 1:4 (1
cement: 4 coarse sand). As per DSOR item No.
6.1.1 and direction of site engineer
24 24 Half brick masonry with common burnt clay Sqm 300.60 1327.00 398896.20
F.P.S. (non modular) bricks of class designation
7.5 in super structure above plinth level up to
floor V level. Cement mortar 1:4 (1 cement :4
coarse sand) as per DSOR item No. 6.13.2 and
direction of site engineer
fine sand). As per DSOR item No. 13.1.1 and
direction of site engineer
26 26 Finishing walls with Acrylic Smooth exterior Sqm 200.00 190.00 38000.00
paint of required shade: New work (Two or more
coat applied @ 1.67 Ltr/10 sqm over and
including priming coat of exterior primer applied
@ 0.90 litre/10 sqm). As per DSOR item no.
13.46.1 and direction of site engineer.
27 27 Dry brick on edge flooring in required pattern Sqm 90.60 935.00 84711.00
with bricks of class designation 7.5 on a bed of
12 mm mud mortar, including filling joints with
Jamuna sand, with common burnt clay non
modular bricks. As per DSOR item no.11.2 and
direction of site engineer.
coarse sand: 4 graded stone aggregate) finished
with a floating coat of neat cement, including
cement slurry, but excluding the cost of nosing
of steps etc. complete. (40 mm thick with 20
mm nominal size stone aggregate). As per
DSOR item no.11.3.1 and direction of site
29 29 Cement Plasster in coarse sand: 12 mm cement Sqm 240.00 422.00 101280.00
plaster (1 cement : 4 coarse sand). As per DSOR
item no.13.4.1 and direction of site engineer
NFR HQ-ELECTRICAL/N F RLY
30 30 Supplying, installing, testing and commissioning Numbers 2.00 45871.00 91742.00
of submersible sludge / sewage pump set
suitable for handling sewage, sludge and dirty
water, 3 HP capacity, complete with squirrel-
cage induction motor, suitable for three phase,
415 volts, 50 Hz AC supply, capable of
continuous operation, including all necessary
accessories, complete as required and as per
site engineer in charge.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCC-2022.pdf
ATTACHMENT
MicrosoftWord-ANNEXURES_August23to4thcorrectionslip.pdf
ATTACHMENT
GCC2022advancecorrectionslip1.pdf
ATTACHMENT
GCC2022advancecorrectionslip2.pdf
ATTACHMENT
GCC2022AdvanceCorrectionSlipNo_3.pdf
ATTACHMENT
GCC2022AdvanceCorrectionSlipNo_4.pdf
ATTACHMENT
GCC2022advancecorrectionslip5.pdf
ATTACHMENT
letterofcredit.pdf
ATTACHMENT
tender doc
ATTACHMENT
63-AtGoshalaImprovementof3311kVGoshalaSubstationandUpgradationof11kVFeeder1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .