| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹100.0 LAdmitted-Finance | L1 | Admitted-Finance | |
| 2 | L2₹1.0 Cr+₹12,386 (0.12%)Admitted-Finance | L2 | Admitted-Finance | |
| 3 | L3₹1.1 Cr+₹11.0 L (11.0%)Admitted-Finance RZ 151 BLOCK Y NEW ROSHANPURA PAPRAWAT ROAD NAJAFGARH SOUTH WEST DELHI DELHI 110043 | WEST DELHI | DELHI | 110043 | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | RAKESH DUTT SHARMA & SONS L2 | M/s S.K.Industries L1 | MODERN CONCEPT CONSTRUCTIONS L3 |
|---|---|---|---|---|---|---|
| 1.00Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. | ||||||
| 2.00 | All kinds of soil. | 157 | cum | 28,731 ₹28,731 Lowest | 35,325 ₹35,325 | 31,400 ₹31,400 |
| 3.00 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m. | 91 | cum | 5,187 ₹5,187 Lowest | 18,200 ₹18,200 | 10,920 ₹10,920 |
| 4.00 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. | 17 | cum | 21,930 ₹21,930 Lowest | 28,050 ₹28,050 | 30,600 ₹30,600 |
| 5.00Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : | ||||||
| 6.00 | 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) | 52 | cum | 2,87,040 ₹2,87,040 Lowest | 3,12,000 ₹3,12,000 | 3,12,000 ₹3,12,000 |
| 7.00 | Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth. | 16 | sqm | 13,440 ₹13,440 | 8,000 ₹8,000 Lowest | 8,000 ₹8,000 Lowest |
| 8.00Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : | ||||||
| 9.00 | 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu- ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) | 10.5 | cum | 74,025 ₹74,025 | 73,500 ₹73,500 Lowest | 79,800 ₹79,800 |
| 10.00 | Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources). | 7 | cum | 58,800 ₹58,800 | 50,750 ₹50,750 Lowest | 56,700 ₹56,700 |
Tender Value
₹1.1 Cr
EMD Value
₹2.6 L
Closing Date
27 Dec 2022, 3:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer (Civil Division-III)
Room No- MZ-137, Main Building, IIT Delhi,Hauz Khas, New Delhi-110016
Construction of Temporary Composite Structure Lab for Applied Mechanics Department between block III and IV in academic area at IIT Delhi.
2022_IIT_730041_1
IITD/WORKS (SP-4053)/2022
Open Tender
Miscellaneous Works
Works
120 days
Indian Institute of Technology Delhi
Please refer Tender documents.
16 documents required · 16 mandatory
₹1,000
Registrar IIT Delhi
₹2.6 L
5 Jan 2023
19 Dec 2022
28 Dec 2022
19 Dec 2022
27 Dec 2022
19 Dec 2022
Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :
1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources) over 75mm thick bed of dry brick ballast 40 mm nominal size, well rammed and consolidated and grouted with fine sand, including necessary excavation, levelling & dressing & finishing the top smooth.
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement :
1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natu- ral sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)
Reinforced cement concrete work in beams, suspended floors, roofs having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to floor five level, excluding the cost of centering, shuttering, finishing and reinforcement with 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources).
Centering and shuttering including strutting, propping etc. and removal of form for
Foundations, footings, bases of columns, etc. for mass concrete
Suspended floors, roofs, landings, balconies and access platform
Lintels, beams, plinth beams, girders, bressumers and cantilevers
Columns, Pillars, Piers, Abutments, Posts and Struts
Extra for additional height in centering, shuttering where ever required with adequate bracing, propping etc., including cost of de-shuttering and decentering at all levels, over a height of 3.5 m, for every additional height of 1 metre or part thereof (Plan area to be measured).
Suspended floors, roofs, landing, beams and balconies (Plan area to be measured)
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete above plinth level.
Thermo-Mechanically Treated bars of grade Fe-500D or more.
Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge; for the following grades of concrete. Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 1.10 times of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cement.
All works upto plinth level
Concrete of M25 grade with minimum cement content of 330 kg /cum
Concrete of M30 grade with minimum cement content of 350 kg /cum
All works above plinth level upto floor V level
Concrete of M25 grade with minimum cement content of 330 kg /cum
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in:
Cement mortar 1:6 (1 cement : 6 coarse sand)
Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in :
Cement mortar 1:6 (1 cement : 6 coarse sand)
Providing and fixing aluminium die cast body tubular type universal hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body, door weight upto 35 kg and door width upto 700 mm), with necessary accessories and screws etc. complete.
Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screws etc. complete :
Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete :
Providing and fixing aluminium hanging floor door stopper, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour and shade, with necessary screws etc. complete.
Twin rubber stopper
Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
Supplying and fixing rolling shutters of approved make, made of required size M.S. laths, interlocked together through their entire length and jointed together at the end by end locks, mounted on specially designed pipe shaft with brackets, side guides and arrangements for inside and outside locking with push and pull operation complete, including the cost of providing and fixing necessary 27.5 cm long wire springs manufactured from high tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top cover of required thickness for rolling shutters.
80x1.25 mm M.S. laths with 1.25 mm thick top cover
Providing and fixing ball bearing for rolling shutters.
Extra for providing mechanical device chain and crank operation for operating rolling shutters.
Exceeding 16.80 sqm in area
Providing and fixing T-iron frames for doors, windows and ventilators of mild steel Tee-sections, joints mitred and welded, including fixing of necessary butt hinges and screws and applying a priming coat of approved steel primer.
Fixing with carbon steel galvanised dash fastener of required dia and size (to be paid for separately)
Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
Hot finished welded type tubes
Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.
In stringers, treads, landings etc. of stair cases, including use of chequered plate wherever required, all complete
In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
62 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size) and top layer 12mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate, 6mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture’s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete.
Providing and laying Vitrified tiles in floor in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS:15622, of approved brand & manufacturer, in all colours and shade, laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand) jointing with grey cement slurry @3.3 kg/sqm including grouting the joints with white cement and matching pigments etc. The tiles must be cut with the zero chipping diamond cutter only . Laying of tiles will be done with the notch trowel, plier, wedge, clips of required thickness, leveling system and rubber mallet for placing the tiles gently and easily.
Glazed Vitrified tiles Matt/Antiskid finish of size
Size of Tile 600 x 600 mm
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i) Single socketed pipes.
110 mm diameter
Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
Ridges plain (500 - 600mm)
Flashings/ Aprons.( Upto 600 mm)
Gutter (600 mm over all girth)
Providing and fixing Gl Clip in Metal Ceiling System of 600x600 mm module which includes providing and fixing 'C' wall angle of size 20x30x20 mm made of 0.5 mm thick pre painted steel along the perimeter of the room with help of nylon sleeves and wooden screws at 300 mm center to centre, suspending the main C carrier of size 10x38x10 mm made of G.I steel 0.7 mm thick from the soffit with help of soffit cleat 37x27x25x1.6 mm, rawl plugs of size 38x12 mm and C carrier suspension clip and main carrier bracket at 1000 mm c/c. Inverted triangle shaped Spring Tee having height of 24 mm and width of 34 mm made of Gl steel 0.45 mm thick is then fixed to the main C carrier and in direction perpendicular to it at 600 mm centers with help of suspension brackets. Wherever the main C carrier and spring T have to join, C carrier and spring T connectors have to be used. All sections to be galvanized @ 120 gms/sqm (both side inclusive), fixing with clip in tiles into spring T with :
GI Metal Ceiling Clip in plain Beveled edge global white color tiles of size 600x600 and 0.5 mm thick with 25 mm height, made of G I sheet having galvanizing of 100 gms/ sqm (both sides inclusive) and 20% perforation area with 1.8 mm dia holes and having NRC of 0.5, electro statically polyester powder coated of thickness 60 microns (minimum), including factory painted after bending and perforation.
15 mm cement plaster on the rough side of single or half brick wall of mix :
1:6 (1 cement: 6 fine sand)
Pointing on brick work or brick flooring with cement mortar 1:3 (1 cement : 3 fine sand):
Flush / Ruled/ Struck or weathered pointing
Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface :
Water thinnable cement primer
Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade:
New work (Two or more coats applied @ 1.43 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :
Two or more coats on new work
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Disposal of building rubbish / malba / similar unserviceable, dismantled or waste materials by mechanical means, including loading, transporting, unloading to approved municipal dumping ground or as approved by Engineer-in-charge, beyond 50 m initial lead, for all leads including all lifts involved.
Providing and laying at or near ground level factory made kerb stoneof M-25 grade cement concrete in position to the required line, leveland curvature, jointed with cement mortar 1:3 (1 cement: 3 coarsesand), including making joints with or without grooves (thickness ofjoints except at sharp curve shall not to more than 5mm), includingmaking drainage opening wherever required complete etc. as perdirection of Engineer-in-charge (length of finished kerb edging shallbe measured for payment). (Precast C.C. kerb stone shall be approvedby Engineer-in-charge).
Providing and laying factory made chamfered edge Cement Concretepaver blocks in footpath, parks, lawns, drive ways or light trafficparking etc, of required strength, thickness & size/ shape, made bytable vibratory method using PU mould, laid in required colour &pattern over 50mm thick compacted bed of sand, compacting andproper embedding/laying of inter locking paver blocks into the sandbedding layer through vibratory compaction by using plate vibrator,filling the joints with sand and cutting of paver blocks as per requiredsize and pattern, finishing and sweeping extra sand. complete all asper direction of Engineer-in-Charge.
80 mm thick C.C. paver block of M-30 grade with approvedcolor design and pattern.
Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, paneling and dash fasteners to be paid for separately) :
For fixed portion
Powder coated aluminium (minimum thickness of powder coating 50 micron)
For shutters of doors, windows & ventilators including providing and fixing hinges/ pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber / neoprene gasket required (Fittings shall be paid for separately)
Powder coated aluminium (minimum thickness of powder coating 50 micron)
Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS: 12823 Grade l Type ll, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of engineer-in-charge.
Pre-laminated particle board with decorative lamination on both sides
Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of engineer-in-charge . (Cost of aluminium snap beading shall be paid in basic item):
With float glass panes of 5 mm thickness (weight not less than 12.50 kg/sqm)
Providing and fixing Brass 100mm mortice latch and lock with 6 levers without pair of handles (best make of approved quality) for aluminium doors including necessary cutting and making good etc. complete.
Providing and fixing aluminium round shape handle of outer dia 100 mm with SS screws etc. complete as per direction of Engineer-in-charge
Powder coated minimum thickness 50 micron aluminium
Providing and fixing 50mm thick sandwich roof panel (factory made) as per specification as follow. a) Outer sheet; 0.50mm (TCT) precoated galvanized trapezoidal steel sheet having minimum 30mm crest depth, polyester top coat & alkyd backer. Zinc coating shall be 120 gsm as per IS-277. Top coat polyester 15-18 microns over 5-7 micron epoxy primer. b) Insulation : High density puff insulation. c) Inner Sheet: Colour coated galvanized, slightly ribbed. Thickness 0.50mm (TCT) minimum 15-18 micron top coat polyester coating, Zinc coating 120g/sqm as per IS-277 Grade of steel : Minimum 240Mpa (both sheets). Sheet should have protective guard film of 25 micron minimum to avoid scretches during transportations and should be supplied in single length upto 12 meter or as desired by Engineer-In-Charge. The sheet shall be fixed using self drilling / self tapping screws with EPDM seal, completed upto any pitch in horizontal / vertical or curved surfaces excluding the cost purlins, rafters and trusses and including cutting to size and shape wherever required. Work to be executed as per the instructions of Engineer-In-Charge.
49) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required. (Note : At Double height Area)
49.1) Group C
50) Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.
50.1) Group C
51) Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point (without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.
51.1) Group C
52) Wiring for light/ power plug with 2X4 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit along with 1 No 4 sq.mm FRLS PVC insulated copper conductor single core cable for loop earthing as reqd. Wire Make Havells/Finolex/Polycab.
53) Wiring for light/ power plug with 4X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 2 Nos. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. Wire Make Havells/Finolex/Polycab.
54) Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. Wire Make Havells/Finolex/Polycab.
54.1) 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire
54.2) 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
54.3) 2 X 6 sq. mm + 1 X 6 sq. mm earth wire
54.4) 4 X 2.5 sq. mm + 2 X 2.5 sq. mm earth wire
54.5) 4 X 6 sq. mm + 2 X 6 sq. mm earth wire
55) Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. Make Havells/Finolex/Polycab.
55.1) 3 x 2.5 sq. mm
55.2) 6 x 2.5 sq. mm
55.3) 3 x 4 sq. mm
55.4) 6 x 4 sq. mm
56) Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/ recessed steel/ PVC conduit as required.
57) Supplying and fixing of following sizes of steel conduit along with accessories in surface/recess including painting in case of surface conduit, or cutting the wall and making good the same in case of recessed conduit as required. Make BEC/AKG/NIC
58) Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. Make: Legrand/Crabtree / Wipro north west/Schneider.
58.1) 5/6 A switch
58.2) 15/16 A switch
58.3) 3 pin 5/6 A socket outlet
58.4) 6 pin 15/16 A socket outlet
58.5) Telephone socket outlet
59) Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. Make: Legrand/Crabtree / Wipro north west/Schneider.
60) Supplying and fixing following size/ modules, GI box alongwith modular base & cover plate for modular switches in recess etc. as required. Make: Legrand/Crabtree / Wipro north west/Schneider.
60.1) 3 Module (100mmX75mm)
60.2) 12 Module (200mmX150mm)
61) Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch, connections etc. as required. Make: Legrand/Crabtree / Wipro north west/Schneider.
62) Supplying and drawing of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed steel/ PVC conduit as required. (Make: Havells/ Beldon/ D-Link/ Polycab)
62.1) 1 run of Cable
62.2) 2 run of Cable
63) Providing and fixing M.S. Fan clamp type I or II of 16 mm dia M.S. bar, bent to shape with hooked ends in R.C.C. slabs or beams during laying, including painting the exposed portion of loop, all as per standard design complete as required. Rate to be taken
64) Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. Make ; Havells /L&T/legrand/Schneider
64.1) 125 A, 16 kA,TPMCCB
64.2) 150 A, 16 kA,TPMCCB
65) Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) Make ; Havells /L&T/legrand/Schneider
65.1) 12 way, Double door
66) Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A, tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer) as required. (Note: Vertical type MCB TPDB is normally used where 3 phase outlets are required.) (MCCB as a incomer) Make ; Havells /L&T/legrand/Schneider
66.1) 8 way (4 + 24), Double door
66.2) 12 way (4 + 36), Double door
67) Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make ; Havells /L&T/legrand/Schneider
67.1) Single pole
67.2) Triple pole
68) Supplying and fixing 20 A, 240 V, SPN Industrial type socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 A, “C” curve, SP, MCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Make ; Havells /L&T/legrand/Schneider
69) Supplying and fixing 30 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 30 A "C" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Make ; Havells /L&T/legrand/Schneider
70) Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
70.1) 225 mm width X 50 mm depth X 1.6 mm thickness
71) Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (Galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required.
71.1) 225 mm width X 50 mm depth X 1.6 mm thickness
72) Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.
73) Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling etc. as required.
74) Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required.
75) Providing and fixing 4.00 mm dia copper wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
76) Supplying, Installation, Testing and Commissioning of 1200 mm sweep, 32 Watt BEE 5 star rated, ceiling fan with brush less Direct current (BLDC) Motor, class of insulation: B, 3 nos. blades, 30 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, power factor not less than 0.9, service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, remote or electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts; washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required. (Make : Havells/ Crompton/ USHA/ Bajaj/ Orient/ )
77) Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
78) Supplying and making end termination with brass compression gland and aluminium and copper lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.
78.1) 3½ X 50 sq. mm (35mm)
78.2) 3½ X 150 sq. mm (50mm)
78.3) 4 X 16 sq. mm (28mm) (copper)
79) Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc. as required
79.1) 100 mm dia
80) Supplying, installation, testing & commissioning of smoke detector with built-in LED and mounting base complete with all connections etc. as required. (Make: Mather and Platt/ Meltron/ Steelage industries/ Safeway Security System, Mumbai/ Carmel and Ravel Electronic Co. Chennai) Note : At Double Height.
81) Supplying, installation, testing & commissioning of smoke detector with built-in LED and mounting base complete with all connections etc. as required. (Make: Mather and Platt/ Meltron/ Steelage industries/ Safeway Security System, Mumbai/ Carmel and Ravel Electronic Co. Chennai)
82) Supplying, installation, testing & commissioning of manual call box of ABS type in surface/recess with stainless steel chain & hammer assembly complete with glass and push button etc. as required. (Make: Mather and Platt/ Meltron/ Steelage industries/ Safeway Security System, Mumbai/ Carmel and Ravel Electronic Co. Chennai)
83) Supplying, installation, testing & commissioning response indicator on surface/recess MS box having two LEDs metallic cover complete with all connections etc. as required. (Make: Mather and Platt/ Meltron/ Steelage industries/ Safeway Security System, Mumbai/ Carmel and Ravel Electronic Co. Chennai)
84) Supplying, installation, testing & commissioning fire alarm sounder with facility to make announcement, mounted in A.B.S. box with hinged cover plate & suitable for operation with amplifier i/c line matching transformer etc. complete as required. (Make: Mather and Platt/ Meltron/ Steelage industries/ Safeway Security System, Mumbai/ Carmel and Ravel Electronic Co. Chennai)
85) Supplying & laying of 2x1.5 sqmm fire alarm armoured cable, 600/1000V rated with annealed copper conductor having XLPE insulation, steel wire armouring & FRLS outer sheath complete as required. (Make: Havells/ Finolex/ Polycab)
86) Supplying, installation, testing & commissioning of main fire alarm control panel made out of 16 SWG MS sheet to accommodate the following items duly powder coated in approved colour with louvers for ventilation, locking arrangement, audio and visual indication for fire alarm monitoring system including connections, interconnections etc. complete as required. 6 zone panel for fire alarm system 100 watt amplifier racks suitable for operation on 230V AC/24V DC supply conforming to IEC-268-3 complete with all accessories as required. Battery charger trickle cum boost to take complete load of fire alarm system complete with all accessories including providing & fixing of 2 nos. 12 volt, 42 AH each sealed maintenance free batteries -1 set. (Make: System-Tek/Morley/Agni/Ravel/Safeway Security System)
87) 15.86 mm (5/8 inch) dia (OD) (Soft drawn) with tube thickness 1.2 mm with class - 1 nitrile rubber tube (foam) insulation of not less than 9 mm thick.
88) 9.5 mm (3/8 inch) dia (OD) (Hard drawn) with tube thickness 1.2 mm with class - 1 nitrile rubber tube (foam) insulation of not less than 9 mm thick.
89) Supplying and fixing following rating, double pole, 240 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make ; Havells /L&T/legrand/Schneider
90) Supplying and fixing following rating, Triple pole, 415 volts, MCB in the existing MCB DB complete with connections, testing and commissioning etc. as required. Make ; Havells /L&T/legrand/Schneider
91) Supplying and fixing 63A, 415 V, 5 pin Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top along with 63A "C" curve, TPNMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. Make ; Havells /L&T/legrand/Schneider
92) Providing and fixing FR PVC DLP adaptable trunking without cover of (150 mm x 50 mm) size with provision of internal partition separation for Power & LAN on surface on existing wall etc. as required. (Make: Legrand)
93) Providing and Fixing following accessories on the existing FR DLP PVC trunking (150mm x 50mm) etc. as required. (Make: Legrand)
94) Providing and Fixing of FR PVC trunking cover width 40 mm + full cover width 85 mm for Power + LAN component
95) Providing and fixing of Clip on partition - Plastic (Make: Legrand)
96) Providing and fixing of Separation on partition - Plastic (Make: Legrand)
97) Providing and fixing of End caps for 150 mm x 50 mm trunking (Make: Legrand)
98) Providing and fixing of Internal angle for 150 mm x 50 mm trunking (Make: Legrand)
99) Providing and fixing of External angle for 150 mm x 50 mm trunking (Make: Legrand)
100) Providing and fixing of 90° Flat angle for 150 mm x 50 mm trunking (Make: Legrand)
101) Supplying and Fixing DLP U-PVC trunking of 105mm x 50mm on surface etc. as required.
102) Supplying and Fixing Full Flexible cover of width 85mm on existing DLP U-PVC trunking etc. as required.
103) Supplying and Fixing of internal angle for 105mm x 50mm existing DLP U-PVC trunking etc. as required.
104) Supplying and Fixing of external angle for 105mm x 50mm existing DLP U-PVC trunking etc. as required.
105) Providing and fixing of 90° Flat angle for 105 mm x 50 mm trunking (Make: Legrand)
106) Supplying and Fixing of End cap for 105mm x 50mm on existing DLP U-PVC turnking etc as required.
107) Supplying and Fixing 1 module arteor frame for 40 mm cover (Make: Legrand)
108) Supplying and fixing of 3 module arteor frame for 85 mm cover (Make: Legrand)
109) Supplying and fixing of 6 module arteor frame for 85 mm cover (Make: Legrand)
110) Supplying and fixing following modular switch/ socket on the existing 1/3/6 module frame / U-PVC trunking system including connections etc. as required.
110.1) Information socket - category 6-UTP - 1 module (Make: Legrand)
110.2) 6 Amp switch
110.3) 20 Amp switch
110.4) 6 Amp switch-2/3 pin universal socket outlet
110.5) 6 pin 20 Amp socket outlet/6 pin 6/16 A universal socket
111) S/I/T/C of 80watt LED high bay fixture at 8.0 Mtr height (Double Height) equipped with pressure die cast aluminium housing, power coated with weather proof gasket ensuring IP66, heat resistant with PC/PMMA highbay lences toughened glass suitable for surface /suspended / ceiling mounting arrangement and excellent heat dissipation for long life, inbuilt surge protection 4kV, power factor > 0.95 toughened glass with silicon gasket for IP66 protection. Suitable for operation 230 volt, 50Hz and output lumens not less than 150lm/watt on existing angle / bracket i/c connections etc. as required. Make Havells / Philips / Wipro
112) S/I/T/C of recess mounting LED luminaire with chain & hook equipped with CRCA powder coating housing, anti-glare polycarbonate diffuser with energy efficient electronic driver with following features: - suitable for operation voltage and frequency: 130-300 V AC, 50 Hz ; wattage 36 watts, Output lumens not less than 120lm/watt; CCT not less than 6500K; Dimension in mm (595x595); Normal surge protection 2.5kV; power factor not less than 0.9; Minimum IP protection 20. including dismantling of existing lights (Make : Philips/ Wipro/ Havells)
113) S/I/T/C of surface mounting LED luminaire equipped with CRCA powder coating housing, anti-glare polycarbonate diffuser with energy efficient electronic driver with following features:- suitable for operation voltage and frequency: 130-300 V AC, 50 Hz ; wattage 36 watts, Output lumens not less than 1201m/watt; CCT not less than 6500K; Dimension in mm (595x595); Normal surge protection 2.5kV; power factor not less than 0.9; Minimum IP protection 20. including dismantling of existing light (Make : Philips/ Wipro/ Havells)
114) S/I/T/C of surface mounting round/square LED luminaire equipped with CRCA powder coating housing, anti-glare polycarbonate diffuser with energy efficient electronic driver with following features:- suitable for operation voltage and frequency: 130-300 V AC, 50 Hz ; wattage 12 watts, Output lumens not less than 1001m/watt; CCT not less than 5700K; slim profile surface mounted down light square/ round type; Normal surge protection 2.5kV; power factor not less than 0.9; Minimum IP protection 20. (Make : Philips/ Wipro/ Havells)
115) S/I/T/C of surface mounting hexagon bulk head back-lit LED luminaire equipped with CRCA powder coating housing, anti-glare polycarbonate diffuser with energy efficient electronic driver with following features:- suitable for operation voltage and frequency: 130-300 V AC, 50 Hz ; wattage 10 watts, Output lumens not less than 1001m/watt; CCT not less than 6500K; slim profile surface mounted suitable for outdoor, surge protection 2.5kV; power factor not less than 0.9; Minimum IP protection 66. (Make : Philips/ Wipro/ Havells/ )
116) S/I/T/C of high speed wall mounting fan 400 mm sweep, copper winding, capacitor start, suitable for operation on 230V, 50 Hz, AC supply with inbuilt speed regulator etc. complete with all standard accessories such as motor, blades clamp etc. as required. (Make : Havells/ Crompton/ USHA/ Orient) Colour of fan shall be finalized by Engineer-in-charge)
117) S/I/T/C of 24"(600mm) size,900rpm,copper wound, heavy duty metallic Exhaust Fan of double ball bearing capacitor start, suitable for 230 volt,50 Hz, single phase A.C. supply and complete with accessories such as motor, legs, frame, loober and Nut & bolts etc. complete as required Make Crompton / GE / havells
118) S/I/T/C of 10"(250mm) size, copper wound, ventiling fresh air fan of double ball bearing capacitor start, suitable for 230 volt,50 Hz, single phase A.C. supply and complete with accessories such as motor, legs, frame, loober and Nut & bolts etc complete as required Make Crompton Greaves / GE /Havells Ventil Air-DX White.
119) Providing and fixing 160A,36kA,FP MCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders with SS Enclosure box(l & T make) suitable for 415 volt,3 phase,4 wire,50 Hz A.C supply system including drilling holes in SS enclosure box, making cable connections, etc. as required. Note: SS Enclosure is include in this item) Make L&T/Legrand/Schneider
120) Supplying and Laying of one number PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Make : Havells/Finolex/NICOO
120.1) Above 95 sq. mm and upto 185 sq. mm (3.5C x 150 sq.mm)
121) Supplying and Laying of one number additional PVC insulated and PVC sheathed / XLPE Aluminium armoured power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc as required. Make : Havells/Finolex/NICOO
121.1) Above 35 sq. mm and upto 95 sq. mm (3.5C x 50 sq.mm)
122) Supplying & Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium power cable of 1.1 kV grade of following size on wall surface as required. Make : Havells/Finolex/NICOO
122.1) Above 35 sq. mm and upto 95 sq. mm (3.5C x 50 sq.mm) (clamped with 25x3mm MS flat clamp)
122.2) Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) (3.5C x 150 sq.mm)
123) Supplying, Laying and fixing of one number PVC insulated and PVC sheathed / XLPE Aluminium and copper power cable of 1.1 KV grade of following size on cable tray as required. Make : Havells/Finolex/NICOO
123.1) Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) (3.5C x 50 sq.mm)
123.2) Upto 35 sq. mm (4C x 16 sq.mm) copper cable (clamped with 1mm thick saddle)
124) Providing and fixing 400A,36kA,FP MCCB rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders with SS Enclosure box(l & T make) suitable for 415 volt,3 phase,4 wire,50 Hz A.C supply system including drilling holes in SS enclosure box, making cable connections, etc. as required. Note: SS Enclosure is included in this item) Make L&T/Legrand/Schneider
125) Supplying, Installation, Testing & Commissioning i/c making solid foundation of brick, cement concrete (0.50Mtr above the ground level) of cubical type Feeder Pillar Double Door Outdoor Type suitable for 415V, 3 Phase, 4 wire 50 Hz AC supply system, fabricated in compartmentalized (preferably) design from CRCA sheet steel of 2mm thick for frame work and covers, 3mm thick for gland plates i/c cleaning & finishing complete with for powder coating for prickling and degreasing in approved shade, having 500 amp capacity extensible type TPN Aluminium Alloy bus bars of high conductivity, DMC/SMC bus bars supports with short circuit withstand capacity of 31 MVA for 1 sec., bottom base channel of MS section not less than 100mm x 50mm x 5mm thick, fabrication shall be done in transportable sections, entire panel shall have a common copper earth bar of size 25mm x 5mm at the rear with 2 Nos. earth stud, solid connections from main bus bar to switch gears with required size of AL. bus bars and control wiring with 2.5 sq.mm PVC insulated copper conductor S/C cable, cable alleys, cable gland plates in two half, i/c providing following switch gears.
INCOMER
(i) 1 Nos. 400 Amps. FP MCCB of 36 KA with inbuilt protection.
MAIN BUS BARS
TPN aluminium bus bars of minimum of 500 Amps capacity with heat shrinkable coloured sleeves and i/c DMC/SMC bus bars supports at required intervals complete for cross section, size supports & their spacing etc. for withstanding fault level of 31 MVA for 1 sec.
METERING
iii) 3 Nos. phase indication lights LED type with protection MCB.
OUTGOINGS
i) 1 Nos. 250 Amps. FP MCCB of 36 KA with inbuilt protection.
ii) 6 Nos. 160 Amps. FP MCCB of 36 KA with inbuilt protection.
Total Panel Cubical Type Feeder Pillar AS DESCRIBED ABOVE.
126) Supplying, Installation, Testing and Commissioning of Split Inverter type Air Conditioner unit for cooling comprising factory built evaporator and condenser unit with other kits (remote controller with battery, suction & discharge copper pipe of length not less than 3 m each, copper cable for power connection, etc.) for installation as per following specification: Rated cooling capacity: 1.5 TR (not less than 5250 watts); Star Rating 5 star; Compressor: Rotary type inverter inbuilt for variable speed operation; Refrigerant: Eco-friendly; Material of evaporator & Condenser refrigerant pipe : Copper; Suitable for operation on 230 volt, 50 Hz, AC supply Make ( Hitachi / Blue Star/ LG/ Voltas/ Haier/ Daikin/ Mitsubishi/ O General)
127) Supply, Installation, testing and commissioning including vaccumiazation and nitrogen testing of following nominal sizes of soft drawn copper refrigerant piping for split AC unit, complete with fittings, with suitable adjustable ring type hanger supports (wherever required), jointing / brazing including accessories, insulated with nitrile rubber tube sleeves sections of specified thickness as given below for Suction and Liquidlines, all accessories as per specifications etc. as required : [Acceptable make of copper pipes : Uniflow / Manibhadra / Ganpati / Mexflow / Mandev / Indigo / Godrej / Visiaro]; [Acceptable make of tubular insulation: Visiaro / Marshland / Avi Global / Armaflex / Aajjo / Dynamic / Uttam]
NOTE: (1) The copper piping and piping circuit should be with minimum number of joints, which shall be attained by: (a) Using one end expanded tubes (b) bending the tubes instead of using elbow joints wherever 90 degree bending is required (2) Piping should be routed at site in such a manner, that brazed joints in the refrigeration piping are kept to a minimum (3) The thickness of fittings used shall be same as that of the pipe
128) Supplying and laying ISI marked 25 mm dia pvc pipe (flexible & braided type) for drain line, including providing insulation wherever necessary, proper saddling, etc. complete as required. (Acceptable make: Astral / Supreme / Finolex / Prince / Savera / Ashirvad / Apollo)
129) Supplying and laying of ISI marked hard CPVC pipe of 25 mm dia for draining of sweated water from AC evaporator unit including all accessories providing tee, joints, elbows, insulation wherever necessary etc. complete as required. (Acceptable make: Astral / Supreme / Finolex / Prince / Savera / Ashirvad / Apollo)
130) Supplying and laying of ISI marked FRLS 4 core x 2.5 sqmm PVC insulated industrial flexible copper conductor cable of 1.1 kV grade conforming to IS 694:2010 including making connections etc. as required. (Acceptable make: Havells / Finolex / Polycab / Universal)
131) Supplying and fixing of prototype adjustable readymade stand made of steel for resting condenser unit either on flat surface(Floor mounted) or on wall [as per site requirement - either floor mounted or wall mounted], duly pre painted with anticorrosive paint, nuts, bolts, fasteners, grouting / properly securing from accidental fall, fasteners, etc. complete as required.
RAKESH DUTT SHARMA & SONS
MODERN CONCEPT CONSTRUCTIONS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.84 MB
BOQ_767728.xls
BOQ • 0.53 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .