Loading…
Loading…
Tender Value
₹4.2 Cr
EMD Value
₹8.4 L
Closing Date
16 Apr 2026, 3:00 pmClosed
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
WORKS
14 conditions · 2 needing a document upload
IRGCC 2022 TENDER FORM SECOND SHEET & ACS 1 CLAUSE 10.2 2.Financial Eligibility Criteria: (As Per IRGCC Clause 10.2) 10.2.Financial Eligibility Criteria: The tenderer must have minimum average annual contractual turnover of V/N or 'V' whichever is less; where: V= Advertised value of the tender in Crores of Rupees. N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The Tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet. 10.3 Bid Capacity: The tender/technical bid will be evaluated based on bid capacity formula detailed as Annexure-VI. PLEASE READ ALL IRGCC TENDER FORM SECOND SHEET & ACS 1 CLAUSE 10.2 TO EVALUATE THE FINANCIAL ELIGIBILITY CRITERIA Non submission of Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet by the tenderer shall result in summarily rejection of his / their bid" ( Click here to download Format)
IRGCC 2022 TENDER FORM SECOND SHEET & ACS 1 CLAUSE 10.1 1.Technical Eligibility Criteria: (As Per IRGCC Clause 10.1) (a)The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: 1Three similar works each costing not less than the amount equal to 30% of advertised value of the tender OR 2Two similar works each costing not less than the amount equal to 40% of advertised value of the tender OR 3One similar work costing not less than the amount equal to 60% of advertised value of the tender Note for Item 10.1: Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organisation, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate. PLEASE READ ALL IRGCC TENDER FORM SECOND SHEET & ACS 1 CLAUSE 10.1 TO EVALAUTE THE TECHNICAL ELIGIBILITY CRITERIA
Defination of Similar Work :- Any Work of PI / RRI /ABS /IBH work /LC gate interlocking which includes indoor andoutdoor signalling work.
11 conditions · 1 needing a document upload
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
Complete tender document including NIT details, schedule, conditions is attached herewith. Tenderers are requested to read the tender document thoroughly before quoting their rates.
Tender will be governed as per latest standard Indian Railways General Conditions of Contract, works 2022 and their all correction slips. Tenderer are requested to read the latest IR GCC works 2022 and their all correction slips before submission of their offer and must be submit the all Annexures, documentary evidences, data as mentioned in IRGCC Works 2022 and their all correction slips.
All the documents in support of the Minimum Eligibility Criteria including Letter of Acceptance/Work Order, Documents showing the nature and total value of work, Completion report, Audited balance sheet, Attested certificate from Government employer, Copy of I.T. return etc. should be submitted along with the bid. Railway reserves the right to make or not to make any further reference to the tenderer regarding the fulfillment of the Minimum Eligibility Criteria and to award the tender only on the basis of the documents submitted by the tenderer along with the bid. The tenderer will not have any claim on this account.
Rights of the Railway to deal with Tender: The authority for the acceptance of the tender will rest with the Railway. It shall not be obligatory on the said authority to accept the lowest tender or any other tender, and tenderer(s) shall neither demand any explanation for the cause of rejection of his/ their tender nor the Railway to assign reasons for declining to consider or reject any particular tender or tenders. If the tenderer(s) deliberately gives / give wrong information in his / their tender or creates / create circumstances for the acceptance of his / their tender, the Railway reserves the right to reject such tender at any stage.
Clause 6.1 of IRGCC APRIL 2022 AND ACS 1 : The Tenderers shall submit a copy of certificate stating that all their statements/documents submitted along with bid are true and factual. Standard format of certificate to be submitted by the bidder is enclosed as Annexure-V. In addition to the Annexure-V, in case of other than company/proprietary firm, Annexure V( A) shall also be submitted by the each member of a partnership firm/Joint Venture (JV) /Hindu Undivided Family (HUF) / Limited Liability Partnership (LLP) etc, as the case may be. (As per IRGCC Works 2022 AC no. 2 dated: 13.12.2022). Non submission of above certificate by the bidder shall result in summarily rejection of his/their bid. It shall be mandatorily incumbent upon the tenderer to identify, state and submit the supporting documents duly self attested by which they/he is qualifying the Qualifying Criteria mentioned in the Tender Document.
If the bidder submits Bid security in the form of Bank Guarantee "The original Bank Guarantee should be delivered in person receive and dispatch section of this office (i.e. DRM office, Signal & Telecom, Branch, West Central Railway, Jabalpur) before closing date for submission of bids (i.e. excluding the last date of submission of bids)
IMPORTANT NOTES WITH NIT: 1.As per Railway Boards letter no. 94/CE-I/4 Pt.17 dated: 13.08.2012, for all work contract valuing more than Rs.10 Crore, "two Packet System" of tendering mandatorily be followed. 2.As per Railway Boards letter no. 2002/CE-I/CT/37 JV Pt.VIII dated: 14.12.2012, "JOINT VENTURE FIRMS" shall now be applicable to the works tenders of value More than Rs. 10 Crores. 3.This is highly technical work to be executed only by qualifying MEC stipulated in tender document as per IR GCC 2022 with similar work issued vide CSTE office letter no. WCR/N-HQ/150/Wks/Policy/14 dated: 03.08.2018. No any relaxation in MEC will be given for any consideration. Firm failing to satisfy the MEC will be treated as ineligible firm. (IF MEC APPLICABLE) 4.In terms of railway board's letter no. 2020/CE-I/CT/3E/GCC/Policy dated: 30.12.2020, If the bidder is banned for submission of bids on the date of closing of tender, such bid, even if received, shall be treated as invalid while evaluating the bids. 5.Change of inspection authority may be done by engineer-incharge at a later date. 6.In case of more than one valid & eligible L-1 bidders, tender may be awarded to tenderer having higher bid capacity. In case bid capacity is also the same, tenderer having done more value of similar work in last three previous financial years and current financial years up to the date of the opening of the tender, may be selected for the award. Instructions with respect to bid capacity will follow. Supporting document for this may be clearly uploaded by tenderer with their offer. 7.West Central Railway Joint procedure order for undertaking earth work in the vicinity of electrical, signalling, telecom cables issued vide no. WCR/N-HQ/110/JPO Corrsp/Sig.-99 dated: 08.01.2024 instructed vide GM (S&T) JBP letter no. JBP/N.H.Q.120/Policy/T-1/Part-V dated: 10.01.2024 and procedure for undertaking digging work in the vicinity of signalling, electrical and telecommunication cables issued by railway board vid eno.2021/Tele/5(2)/3-Part(1)(3425647) dated 12.06.2023 or any other latest JPO by railways will be applicable in this contract. 8.It is responsibility of the contractor during execution the work near the track, that all safety precautions will be taken like; Safety Jacket, wearing of Safety Shoes and Helmet to avoid any type of causality. 9.The provisions contained in railways circulars, JPO's regarding penalties will be applicable for works requiring digging. 10.As per railway boards letter no. 2017/CE-I/CT/9 dated: 31.05.2023 "for all contracts costing more than Rs.5 crore, Contractor's e-MB is mandatory and contractor's e-MB should be part of Tender Document. All other provisions of railway boards letter no. 2017/CE-I/CT/9 dated: 31.05.2023 will be followed. (If applicable)
West Central Railway Joint procedure order for undertaking earth work in the vicinity of electrical, signalling, telecom cables issued vide no. WCR/N-HQ/110/JPO Corrsp/Sig.-99 dated: 08.01.2024 instructed vide GM (S&T) JBP letter no. JBP/N.H.Q.120/Policy/T-1/Part-V dated: 10.01.2024 and procedure for undertaking digging work in the vicinity of signalling, electrical and telecommunication cables issued by railway board vid eno.2021/Tele/5(2)/3-Part(1)(3425647) dated 12.06.2023 or any other latest JPO by railways will be applicable in this contract
It is responsibility of the contractor during execution the work near the track, that all safety precautions will be taken like; Safety Jacket, wearing of Safety Shoes and Helmet to avoid any type of causality.
S&T work in connection with provision of IBS between HDU (Hardua) - NMWP (New Majhgawan Phatak) in existing UP & DN main lines and new 3rd line of Jabalpur division on West Central Railway (Signalling Work).
JBP-N-SIG-TENDER-2026-10
JBP-N-SIG-TENDER-2026-10
Open
Works - General
11 Months
Jabalpur, Madhya Pradesh
₹0
₹8.4 L
16 Apr 2026
24 Mar 2026
2 Apr 2026
288 items across 3 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 83,64,617.65 | ||
| — | 30.00 | — | — | ||
| Supply of Tag Blocks 200 way with cover as per IRS: S- 77/2006 (Rev. 1) with latest amendment. INSPECTION BY RDSO. | — | — | — | 48,480.3 | |
| — | 3.00 | — | — | ||
| Supply of PVC insulated flexible wire 16/0.2 mm dia as per RDSO spec. No. IRS:S- 76/89 with latest amendments of various colours. (Red, black & grey) with OEM guaranty/ warranty certificate. INSPECTION BY CONSIGNEE. | — | — | — | 18,884.07 | |
| — | 8.00 | — | — | ||
| DC -DC converter 24-40 V/5A for IPS as per RDSO Spec. No RDSO/SPN/165/2023 Ver 4.0 Amdt 1 or latest amendment. INSPECTION BY RDSO. | — | — | — | 1,88,800 | |
| — | 25.00 | — | — | ||
| Supply of QNA1 (AC immunised relay), 8F-8B, 24VDC along with plug board (Base plate), retaining clips and connectors conforming to BRS:931A, IRS:S34 & IRS:S23. INSPECTION BY RDSO. | — | — | — | 95,279.25 | |
| — | 20.00 | — | — | ||
| Supply of QNA1K (AC immunised relay), 6F-6B, 24VDC along with plug board (Base plate), retaining clips and connectors conforming to BRS:931A, IRS:S34 & IRS:S23. INSPECTION BY RDSO. | — | — | — | 67,925.8 | |
| — | 40.00 | — | — | ||
| Supply of Twin Neutral Line Relay QNNA1, 24V DC, 4F-4B/6F-2B contacts, complete with plug board, retaining clip and connectors. Conforming to BRS: 930A, IRS:S60,, IRS:S34& IRS:S23. (No of each configuration will be decided by Engineer In-charge. (INSPECTION BY RDSO. | — | — | — | 3,21,831.6 | |
| — | 10.00 | — | — | ||
| Supply of Time Element Relay (Clock work type) AG timer Siemens Make No. (RSSK 30/0052) or equivalent with timer range up to 120 seconds. INSPECTION BY RDSO. | — | — | — | 80,936.4 | |
| — | 20.00 | — | — | ||
| Supply of Phenolic Laminated sheet, resin bonded 10mm thick, grade P3 in standard size of 1.22 x 1.22 Mtr as per spec. No IS 2036 of 1974 . INSPECTION BY CONSIGNEE. | — | — | — | 79,156.2 | |
| — | 1.00 | — | — | ||
| Supply of PVC indoor cable 1x24x1 mm dia having colour coding of insulation of inner core shall be six colours viz. Blue, Red, Grey, Green, Brown & Black and shall be confirming to RDSO Specification IRS:S: 76/89 with latest amendments with OEM guaranty/ warranty certificate INSPECTION BY RDSO. | — | — | — | 1,48,542.53 | |
| — | 0.20 | — | — | ||
| Supply of flexible cable single core multistrand copper conductors, 1x6 sq.mm confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY RDSO. | — | — | — | 14,887.69 | |
| — | 3.00 | — | — | ||
| Supply of PVC insulated railway signalling indoor single core [ tinned jumper wire] 1 x 0.6mm dia, different colours, blue: 60%, red:15%, gray: 20% and brown: 5%. with OEM guaranty/ warranty certificate INSPECTION BY RDSO. | — | — | — | 11,888.4 | |
| — | 100.00 | — | — | ||
| Supply of cartridge fuse block made of PBT as per RDSO Drg. Nos. SA -23748 Alt. 4 and Spec. Nos. IRS-S-75/2006 with latest ammendment. Fuse block shall be suitable for round head type fuses. INSPECTION BY RDSO. | — | — | — | 18,044 | |
| — | 100.00 | — | — | ||
| Supply of Non-deteriorating type low voltage cartridge fuse rate current 2Amp / 4 Amp in equal proportion round head type as per specification Nos. IRS/S 78-2006 or latest with latest amendment. INSPECTION BY RDSO. | — | — | — | 7,811 | |
| — | 1000.00 | — | — | ||
| Supply of two in two out (4conductor) Knife edge disconnect terminal block set as per RDSO/SPN/189/2004 Ver 3.0or latest with latest amendment. INSPECTION BY RDSO. | — | — | — | 80,930 | |
| — | 100.00 | — | — | ||
| Supply of end plate suitable for disconnect terminal. INSPECTION BY CONSIGNEE. | — | — | — | 1,208 | |
| — | 50.00 | — | — | ||
| Supply of steel carrier Din rail suitable for fixing disconnect terminal 1 meter long of dimension35mm X 7.5 mm, 1mm thickness, unslotted INSPECTION BY CONSIGNEE. | — | — | — | 7,170.5 | |
| — | 120.00 | — | — | ||
| Supply of end stop suitable for disconnect terminal block INSPECTION BY CONSIGNEE. | — | — | — | 1,268.4 | |
| — | 5.00 | — | — | ||
| Supply of Apparatus Case with miniature 'E' type locks with keys (1 key per 5 location boxes) of ward Nos. 41 (E type lock & key as per drg no. WCR/DY.CSTE(Con)/KOTA/3 with latest Amendment) on both the doors, duly painted with red oxide. Single case as per Drg Nos WS- 8842/A with latest alteration. INSPECTION BY CONSIGNEE. | — | — | — | 64,424.75 | |
| — | 4.00 | — | — | ||
| Supply of Apparatus Case with miniature 'E' type locks with keys (1 key per 5 location boxes) of ward Nos. 41 (E type lock & key as per drg no. WCR/DY.CSTE(Con)/KOTA/3 with latest Amendment) on both the doors, duly painted with red oxide. Half case as per Drg Nos WS- 8842/A with latest alteration. INSPECTION BY CONSIGNEE. | — | — | — | 47,085.36 | |
| — | 50.00 | — | — | ||
| Supply of lamp holders , switches, two pin (Backellite type) and bulbs(230V/110V) for location boxes (Anchor make or ISI mark) INSPECTION BY CONSIGNEE. | — | — | — | 4,070.5 | |
| — | 420.00 | — | — | ||
| Supply of GI pipe, inner dia. 100mm dia. B-class as per spec. No.IS 1239PT. 1/2004 with sockets and fittings. INSPECTION BY CONSIGNEE. | — | — | — | 4,88,863.2 | |
| — | 30.00 | — | — | ||
| Supply of Heat shrinkable straight through joint for UG cables with all accessories as per RDSO spec. no. "IRS /TC/77/2012 (rev-3) with amend.-1 &2 or latest for 6 quad cable 0.9mm dia (TSF-3)joint suitable for 6 quad cable. INSPECTION BY RDSO. | — | — | — | 55,624.5 | |
| — | 13.00 | — | — | ||
| Supply of HDPE duct 40/33 MM AS PER TEC spec. No.GR/CDS/08-02 NOV- 04 along with following accessories : End plug -03 nos, Cable sealing plugs - 03 nos, Plastic couplers-slip fit/push fit type - 03 nos. Rotary Duct Cutter for cutting the duct with replaceable blade- 01 nos. Colour of Duct to be "Bright Yellow/Bright RED/Bright Blue." INSPECTION BY CONSIGNEE. | — | — | — | 7,00,040.77 | |
| — | 3.00 | — | — | ||
| Supply of covered 19'' Racks of size 2200 mm X 600 mm X 600 mm (WQ/Vero President/ Rittal/ APC make) complete with all fittings including DC Fans (48 V) -2 Nos, separator sheet/plate to keep testing equipments - 1 No and AC Power distribution panel (horizontal fitting) with power sockets and fuse/MCB protection (minimum 6 Nos of 230V- 15A/5A. combined) and other accessories. Rack should have compatibility with all equipment conforming to DIN 41494 or equivalent EIA/ ISO/ EN standard, Manufacturer must certify that products are complied with DIN41494 or equivalent EIA/ISO/EN/CEA/UL standards INSPECTION BY CONSIGNEE. | — | — | — | 1,09,228.77 | |
| — | 10.00 | — | — | ||
| Supply of straight joint enclosure (SJC) complete with all accessories as per TEC Specification TEC/GR/TX/OJC-002/03/APR/2010 or latest of reputed make like Raychem, Birla VXL, 3M, shakti or similar. INSPECTION BY CONSIGNEE. | — | — | — | 35,859.6 | |
| — | 2.00 | — | — | ||
| Supply of Cabinet with wiring arrangement of DC-DC converter for 08 Nos. suitable for statcon make IPS. INSPECTION BY CONSIGNEE. | — | — | — | 97,657.34 | |
| — | 1.00 | — | — | ||
| Supply of flexible cable single core multistrand copper conductors, 1x2.5sq.mm confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY RDSO | — | — | — | 21,537.92 | |
| — | 30.00 | — | — | ||
| Supply of earth electrode assembly as per Drg.Nos. S&T/CON/KOTA/Earthing/01 INSPECTION BY CONSIGNEE | — | — | — | 35,928.9 | |
| — | 6.00 | — | — | ||
| Supply, Installation wiring testing and commissioning of SPT (Half Duplex) at IBS location and adjacent stations. Each set shall comprise one no. of signal post telephone(SPT) master unit (which shall be installed on IBS post)along with one no. of slave unit being installed in SM'S office (both master and slave unit must work on 24V DC and must be suitable for 25KVAC RE area).as per instructions of site in-charge , ACES make or similar . Note : The contractor shall ensure that there is no interface in communication between the master and slave units owing to power hump due to RE induction. Cable from IB signal unit to the cable termination board in SM's room/relay room will be provided by the Railways. It shall work on OFC or quad cable & it shall ensured by contractor before supply of the item. INSPECTION BY CONSIGNEE | — | — | — | 87,364.68 | |
| — | 2.00 | — | — | ||
| Supply of Earth Leakage detector 8 channel card (2 channel card for monitoring AC and 6 channel card for monitoring DC voltages) as per RDSO Spec No RDSO/SPN/256/2025 Version : 2.0 with latest amendment. INSPECTION BY RDSO | — | — | — | 2,10,228.94 | |
| — | 100.00 | — | — | ||
| Supply of INDICATIVE TYPE OF FUSE INSERTS. With holder 1.6 A (System, Rapid or Malnad Make or similar). INSPECTION BY RDSO | — | — | — | 7,842 | |
| — | 100.00 | — | — | ||
| Supply of INDICATIVE TYPE OF FUSE INSERTS. With holder 0.6A(System, Rapid or Malnad Make). INSPECTION BY RDSO | — | — | — | 7,515 | |
| — | 8.00 | — | — | ||
| Supply of Main Signal Post 140 mm outer dia 4.5 Mtr Length as per spec No IRS S 6/81 with latest amendments. INSPECTION BY CONSIGNEE | — | — | — | 51,489.52 | |
| — | 8.00 | — | — | ||
| Supply of Cast Iron Main signal surface base 140mm as per spec Nos IRS S 10 and Drg Nos 2011/M with latest amendments, with CLS Ladder assembly complete for CLS signal 5.5 50 Mtrs long as per RDSO Drg. Nos. SA- 23156. & signal front staging complete assembly. INSPECTION BY CONSIGNEE | — | — | — | 95,162.24 | |
| — | 8.00 | — | — | ||
| Supply of Signal Nos. plates. as per Drg enclosed. INSPECTION BY CONSIGNEE | — | — | — | 4,696.88 | |
| — | 8.00 | — | — | ||
| Supply of A/AG/C/P/G board as per RDSO Drg. Nos. SA 23455-56 RST- 52 11445 & SA 23476-77 as applicable INSPECTION BY CONSIGNEE | — | — | — | 5,303.44 | |
| — | 4.00 | — | — | ||
| Supply of Goods warning Board as per RDSO Drg Nos. SA 2380 (Adv). Paint and retroreflective arrangement as per drg Nos BPL/S&T/M/47 INSPECTION BY CONSIGNEE | — | — | — | 12,014.28 | |
| — | 30.00 | — | — | ||
| Supply of Hand Cuff Locks / Godrej Navtal lock with common key. INSPECTION BY CONSIGNEE | — | — | — | 9,627.6 | |
| — | 8.00 | — | — | ||
| Non Metallic (FRP) colour light signal housing multi unit type for railway signaling suitable for RE area TWO Aspects. Complete without lenses, lamps and signal transformer as per RDSO DRG. No. SA 23001/A/M Adv. Alt- S and as per SPEC. No. RDSO/SPN/194/2006 (Ver. 1.0) or latest and FRP material as per RDSO SPEC. No. RDSO/SPN/151/1997 or latest INSPECTION BY CONSIGNEE | — | — | — | 2,08,740.96 | |
| — | 4.00 | — | — | ||
| Supply of Automatic media changeover working on redundant channels for data transmission on OFC/Quad as per IRS Specn. No.IRS:S- 104/2012 Ver.0 with latest ammendment. INSPECTION BY CONSIGNEE | — | — | — | 1,76,320.32 | |
| — | 10.00 | — | — | ||
| Supply of Relay Non-AC Immune, plug-in-type, DC Neutral Line 60V4F/4B, 5F/3B, 6F/2B contacts, front and back contacts metal to metal, conforming to IRS: S 46 and firm's specification. The relay housing shall contain two miniature identical relays in mini group housing complete with base plate, INSPECTION BY RDSO | — | — | — | 1,09,932.7 | |
| — | 30.00 | — | — | ||
| Supply of Relay AC-LED Universal ECR Siemens (Nos. A-RT-RG-A064) or equivalent with base plate and shall be suitable for working in series with 110V AC, LED based signal lighting unit. INSPECTION BY RDSO | — | — | — | 1,88,375.4 | |
| — | 160.00 | — | — | ||
| Supply & Installation, testing and commissioning of fuse alarm system of Fuse Auto changeover system (FACS) for vital fuses as per RDSO specification No. RDSO/SPN /209 /2012 Rev.2.0 or latest. Spares to be supplied as per the RDSO specification. Inspection by RDSO INSPECTION BY RDSO.PER UNIT = PER FUSE INSPECTION BY RDSO | — | — | — | 1,09,766.4 | |
| — | 1.00 | — | — | ||
| "Supply Installation, testing and commissioning of Class-A Protection type Surge Protection system Consisting of:- a)Active ESE Lightning conductor as per NFC17- 102. b)Should Provide Radius of Protection of 146 m Model No. LAPDX- 250 or equivalent , tested from international HV test laboratory Certificate for the same. c)Issued to OEM of Lightning Conductor should be attached with tender. d) CE Certificate e)Authorisation letter from OEM should be attached with tender. f) Stainless steel Material with pointed tip g)Delta T should be greater and equal to 96Micro seconds. h) Inhouse certificate from Manufacturer should be provided with material. i) It should be testable by means of external tester. j)GI mast 5m with adopter head and base plate for connecting ESE lightening conductor. k) Lightening counter testable of 6 digits non restable type of stainless steel of material having IP 65 protection manufacturer of 6 digit non restable type of stainless steel material having IP 65 Protection." INSPECTION BY RDSO | — | — | — | 1,07,135.46 | |
| — | 915.00 | — | — | ||
| Supply of STP Cat 6 cable. It should be compliant with latest EIA/TIA-568-B.2-1 standard Make-D-link/ syrotech/Digisol or similar. INSPECTION BY CONSIGNEE | — | — | — | 26,562.45 | |
| — | 15.00 | — | — | ||
| Supply of CAT6 UTP cable 4 pair in box of 1000 feet. it should be compliant with latest EIA/TIA-568-B.2-1 standard Make - D-link/Tyco/Systimax or equivalent. INSPECTION BY CONSIGNEE | — | — | — | 66,460.95 | |
| — | 8.00 | — | — | ||
| Supply of Rack Mounted Fibre Management System (Fully loaded) 19'' rack mountable for 24 fibre FMS of SC adapters as per specification attached. INSPECTION BY CONSIGNEE | — | — | — | 1,09,424 | |
| — | 4.00 | — | — | ||
| Supply of 108 Mbps TDM over Ethernet Access Multiplexer with provision of four DTE E1 channel over fiber port, fiber ports supporting single mode with driving distance up to 15 Kms plus one Ethernet ports 10/100/Mbps , power supply AC/DC option from a single socket Make MROTEK Model .ECAT-01L or equivalent. INSPECTION BY CONSIGNEE | — | — | — | 1,34,066.88 | |
| — | 10.00 | — | — | ||
| Supply of OFC patch chord SC-SC (5 mt). INSPECTION BY CONSIGNEE | — | — | — | 2,230.5 | |
| — | 10.00 | — | — | ||
| Supply of OFC patch chord SC-LC (5 mt) . INSPECTION BY CONSIGNEE | — | — | — | 2,360.4 | |
| — | 50.00 | — | — | ||
| Supply of OFC patch cord Type LC-SC or SC-SC (as per site requirement) Length 10 Mtrs of reputed make. INSPECTION BY CONSIGNEE | — | — | — | 11,863 | |
| — | 8.00 | — | — | ||
| Supply of OFC integrated access device 1U height or1.5 U height/19" rack mountable for LVCD/ Digital Axle Counter purpose with four tributary slots & four protentional free contacts to know quad status , front panel Quad indication status vide LEDs, Optical support vide 4 SFP port supporting TDMoIP in the unit supporting dual core OFC and 04 100/1000 mbps Ethernet port (POE or NON POE as required at site ) for surveillance/ smoke detector, optical SFP ports provided distance support to be 20 KMs, unit to support one E&M card supporting four 2W/4W configurable & four quad port 2W/4W. Each port configurable to support axle counter/ UFSBI/ control phone/ EC/ RTU and one telnet/SNMP port, unit to support 04 E1 ports in addition to 04 SFP ports of TDMoIP, dual DC power supply 18 to 72 VDC support , unit to support change over mechanism automatic between E&M (V.21) to E1 port & optical fiber TDMoIP (SFP) & quad path for E&M interface option, one number cable to be provided along with E&M. Equipment should be able to integrate with STM E1 & IPMPLS 1Gbps ports FABIO 2CX+/OFC/ DC & module 2W/4W four port E&M (1+1) protection Make: TEAM ENGG/FABIO or equivalent. INSPECTION BY RITES/TPI | — | — | — | 18,28,795.76 | |
| — | 100.00 | — | — | ||
| Supply of ARA Terminal Blocks with links made of PBT specn. No. IRS75/2006 (Rev.2) with latest amendments and RDSO Drg. No. SA-23741A. INSPECTION BY RDSO | — | — | — | 6,758 | |
| — | 0.50 | — | — | ||
| Supply of flexible cable single core multi strand copper conductors, 1x10sq.mm confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY RDSO | — | — | — | 59,858.65 | |
| — | 0.50 | — | — | ||
| Supply of flexible cable single core multi strand copper conductors,1x16sq.mm confirming to RDSO specification IRS:S: 76/89 with latest amendments. INSPECTION BY RDSO | — | — | — | 88,524.01 | |
| — | 0.30 | — | — | ||
| Supply of flexible cable single core multi strand copper conductors, 1x25sq.mm confirming to RDSO specification IRS:S: 76/89with latest amendments. INSPECTION BY RDSO | — | — | — | 90,984.45 | |
| — | 100.00 | — | — | ||
| Supply of Concrete Cable Route Marker as per drawing SDO/Cable Laying/020 INSPECTION BY CONSIGNEE. | — | — | — | 31,238 | |
| — | 2.00 | — | — | ||
| Supply and Installation of Modular Power Supply Arrangement for VDU (42 inch to 85 inch) and Industrial PC (Embedded PC) with Input and Output Redundancy Arrangement and Hot Pluggable Modules as per Technical Specifications :- 1. Input O-Ring Diode Module with Potential Free-1 No contacts (PFC) for two 110VDC Sources from IPS and Single 110VDC bus. 2. Isolated Inverters (Master/Slave) : 02 Nos. Input: 110VDC, Output: 120VAC/220VAC 500VA 3. Isolated DC-DC Converters- 2 Nos. Input: 110VDC, Output: 24VDC/10A 4. 3U SS Rack with back Panel Mother Board/Front Panel Power Connectors Inverter Auto Change over Switch and all required over Switch and all required protection circuits as per latest RDSO Specifications- Make- Gallant Power or similar INSPECTION BY CONSIGNEE | — | — | — | 4,59,728 | |
| — | 4.00 | — | — | ||
| Supply of pre wired powder coated MS Cabinet at least 42 U for housing UFSBI electronic modules, relay racks, SPD modules, 4 No. of QN1 (8F/8B)relays per pair & 8 No. QNN1 twin coil relay base etc. as required for commissioning of UFSBI electronics in IBS/ABS application as per IRS Specn. No. IRS:S- 104/2012 Ver.0 with latest amendment. INSPECTION BY RITES/TPI | — | — | — | 6,64,767.68 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of UL/FM/VDS/LPCB approved Microprocessor based networkable analogue addressable and modular type of Fire alarm control panel with display, in built charging facilities and provision of GSM module suitable to send SMS to configured moblie no. The panel should be equipped with nos. of loops and provision of expandability as per RDSO specification no RDSO/SPN/217/2021 ver 3.0 or latest (suitable for distributed as well as centralized). The Control panel shall be the central processing unit of the system, receiving and analyzing signals from probe type bimetallic heat detectors, UV&IR flame detectors, heat and smoke multi sensors, LHS/LHSD interface and manual call points, providing audible and visual information to the user. The panel shall have provision of connectivity of TCP- IP suitable for programming and remote monitoring. The panel shall have dedicated Rs 232 serial port for direct PC or MODEM connection, for interfacing with existing data logger, optional remote printer. ( As per RDSO Specification no. RDSO/SPN/217/2025 Ver.3.1 or latest, Warranty will be exercised as mentioned in RDSO specification) INSPECTION BY RDSO | — | — | — | 1,10,606.59 | |
| — | 15.00 | — | — | ||
| Supply, installation, testing and commissioning of analogue addressable, resettable smoke sensor with LED indication . ( As per RDSO Specification no. RDSO/SPN/217/2025 Ver.3.1 or latest, Warranty will be exercised as mentioned in RDSO specification) INSPECTION BY RDSO | — | — | — | 37,158.9 | |
| — | 15.00 | — | — | ||
| Supply, installation, testing and commissioning of resettable, addressable multi sensor ( Heat & Smoke) which is fully compatible with analogue addressable protocol, Electronically addressed. ( As per RDSO Specification no. RDSO/SPN/217/2025 Ver.3.1 or latest, Warranty will be exercised as mentioned in RDSO specification) INSPECTION BY RDSO | — | — | — | 41,142.3 | |
| — | 2.00 | — | — | ||
| Supply, installation, testing and commissioning of addressable, resettable manual call point with integral short circuit isolator, having status LED for alarming & Stand by mode, Electronically addressed. ( As per RDSO Specification no. RDSO/SPN/217/2025 Ver.3.1 or latest, Warranty will be exercised as mentioned in RDSO specification) INSPECTION BY RDSO | — | — | — | 9,733.04 | |
| — | 100.00 | — | — | ||
| Supply, installation, testing and commissioning of analogue type linear heat sensing cable. (As per RDSO Spec no. RDSO/SPN/217/2025 Ver.3.1 or latest, Warranty will be exercised as mentioned in RDSO specification) INSPECTION BY RDSO | — | — | — | 20,161 | |
| — | 1.00 | — | — | ||
| Supply, installation and testing and commissioning of module of LHS cable to be integraced on fire alarm panel. ( As per RDSO Specification no. RDSO/SPN/217/2025 Ver.3.1 or latest, Warranty will be exercised as mentioned in RDSO specification) INSPECTION BY RDSO | — | — | — | 72,362.81 | |
| — | 1.00 | — | — | ||
| Supply, installation and testing and commissioning of addressable Loop powered wall sounder/alarm. ( As per RDSO Specification no. RDSO/SPN/217/2025 Ver.3.1 or latest, Warranty will be exercised as mentioned in RDSO specification) INSPECTION BY RDSO | — | — | — | 8,406.01 | |
| — | 1.00 | — | — | ||
| Supply, installation, testing and commissioning of FRLS/Fire survival circuit integrity cables i.e armoured cable & Power cable with all accessories for connection of all fire alarm devices. ( As per RDSO Specification no. RDSO/SPN/217/2025 Ver.3.1 or latest, Warranty will be exercised as mentioned in RDSO specification INSPECTION BY RDSO | — | — | — | 22,120.86 | |
| — | 100.00 | — | — | ||
| Supply of PVC conduit Pipe having Diameter 25mm. Supply portion INSPECTION BY CONSIGNEE | — | — | — | 892 | |
| — | 4.00 | — | — | ||
| Installation, testing, commissioning and supply of Automatic Fire detection & Alarm complete system as per below details.(Spares to be provided as per RDSO Spec.)-"Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Monitor Module with inbuilt isolator complying to RDSO/SPN/217/2021 Ver 3.0 or latest. (i) Zone Module = 02 Nos. (ii) Relay Module = 02 Nos. (iii) Monitor Module = 02 Nos. INSPECTION BY RDSO | — | — | — | 41,247.44 | |
| — | 4.00 | — | — | ||
| Installation, testing, commissioning and supply of Automatic Fire detection & Alarm complete system as per below details. (Spares to be provided as per RDSO Spec.)-Supply, Installation, Testing & Commissioning of Analogue Addressable loop powered Control Module fitted with bi-directional inbuilt isolator providing two voltage free, single pole, change over relay output, complying to RDSO/SPN/217/2021 Ver 3.0 or latest. INSPECTION BY RDSO | — | — | — | 41,247.44 | |
| — | 4.00 | — | — | ||
| Installation, testing, commissioning and supply of Automatic Fire detection & Alarm complete system as per below details.(Spares to be provided as per RDSO Spcn.)-Supply, Testing & Commissioning of Isolator Device to isolate the circuit in case of short circuit, complying to RDSO/SPN/217/2021 Ver 3.0 or latest. INSPECTION BY RDSO | — | — | — | 17,552.08 | |
| — | 100.00 | — | — | ||
| Installation, testing, commissioning and supply of Automatic Fire detection & Alarm complete system as per below details.(Spares to be provided as per RDSO Spec.)-Supply, Testing & Commissioning of 2C 1.5 sq mm twisted shielded armoured copper cable (Per Meter) with accessories. INSPECTION BY RDSO | — | — | — | 14,217 | |
| — | 4.00 | — | — | ||
| Supply of fire extinguisher 4.5 Kgs,Co2 gas ISI make with test certificate make, Minimax or VINTAX or similar. INSPECTION BY CONSIGNEE | — | — | — | 24,067.48 | |
| — | 4.00 | — | — | ||
| Supply of portable handheld communication system used for secure peer to peer communication. The device must be equipped latest technology standard as per specification INSPECTION BY CONSIGNEE | — | — | — | 75,198.4 |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
TD-10-HDUNMWP1_compressed.pdf TD HDU NMWP IBS
ATTACHMENT
1GCCWORKS2022ACS1TO11.pdf
ATTACHMENT
3JPO10-1-2412-6-23.pdf
ATTACHMENT
4Letterforshramikkalyanportal_1.pdf LETTER OF SHRAMIK KALYAN DEPT
ATTACHMENT
TD-10-HDUNMWP1_compressed.pdf
ATTACHMENT
4Letterforshramikkalyanportal_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .