| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.3 LAccepted-AOC | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹4.8 L+₹45,875 (10.5%)Rejected-AOC R O RAWALPORA WANBAL YAIYAL TEH DISTT SRINAGAR J K PIN 190005 | SRINAGAR | SRINAGAR | JAMMU AND KASHMIR | 190005 | L2 | Rejected-AOC Not being lowest | |
| 3 | L3₹6.5 L+₹2.1 L (48.2%)Rejected-AOC | L3 | Rejected-AOC Not being lowest |
Tender Value
₹6.5 L
EMD Value
₹13,000
Closing Date
8 Nov 2019, 6:00 pmClosed
GE 970 EWS
GE 970 EWS c/o 56 APO
As described in Bill of Quantities
2019_MES_292578_1
GE 970 EWS-14/2019-20
Open Tender
Civil Works - Others
Item Rate
270 days
Sonamarg
Class E Category a(ii) for contractors enlisted with MES
8 documents required · 8 mandatory
₹500
GE 970 EWS
₹13,000
Yes
3 Jan 2020
25 Oct 2019
11 Nov 2019
25 Oct 2019
8 Nov 2019
2 Nov 2019
Amount
M&L for cleaning of SGSW /RCC/PVC sewage line of 100/150mm dia by rodding/auger rods & drain pipe machine including gully traps, before & after cleaning process of SGSW /RCC/PVC sewage line and well flushing using clean water through water bowser of pipe of any capacity (arranged by the contractor) and removing the sludge etc to a distance n.exc 250m and burying the same underground by digging pit of suitable size from habitant area and returning filling with excavated materials up to ground level including removal of surplus soil to a distance n.exc 250m with and including taking off manholes/gully trap covers and re-fixing the same after cleaning process complete all as specified and directed by Engr-in-Charge. Note :- (i) The contractor/site superivisor will attend the complaint cell of AGE B/R-III to receive the complaint slips daily at 0900 hrs to carry out the complaints and completion report will be submitted to concerned JE/AGE in the same day i.e. before 1700 hrs.
M&L for cleaning of CI/PVC pipe of 75/100mm dia bore fixed to wall by means of opening and rodding through the oval acess door Cleaning and well flushing using clean water through water bowser of pipe of any capacity (arranged by the contractor) taking out all residue etc.closing the oval acess door and removing the sludge material,complete all as specified and directed. Note :- (i) The contractor/site superivisor will attend the complaint cell of AGE B/R-III to receive the complaint slips daily at 0900 hrs to carry out the complaints and completion report will be submitted to concerned JE/AGE in the same day i.e. before 1700 hrs.
M&L for Dewatering of contaminated waste effulient from septic tank/ Soakage well of any capacity and depth by vehicle mount sewage cleaning machine and jetting and disposal to low lying area upto distance of 2 Km incl taking off and refixing manholes covers etc complete all as directed by Engineer-in-Charge. (i) The contractor/site superivisor will attend the complaint cell of AGE B/R-III to receive the complaint slips daily at 0900 hrs to carry out the complaints and completion report will be submitted to concerned JE/AGE before 48 hrs as per complaint slip time.
Cleaning of septic tank of any capacity and depth incl inlet chamber, outlet chamber removing out all sludge, Silt, residue waste material (organic/inorganic nature) by vehicle mount sewage cleaning machine and required manpower after plugging the incoming sewage line and depositing the waste upto 2 km distance and burrying the same in suitable size of pit and covering the same with earth and removal of surplus soil all as directed by engineer in charge. (i) The contractor/site superivisor will attend the complaint cell of AGE B/R-III to receive the complaint slips daily at 0900 hrs to carry out the complaints and completion report will be submitted to concerned JE/AGE before 48 hrs as per complaint slip time. Notes :(a) Cost of excavation of pit and covering the same with earth is to be included in unit rate. (b) Rates against item No.1 to 4 includes for : (i) Cleaning and clearing/disposing off all the sludge/ sewage contaminated water in solid / semi solid / liquid state from sewage lines, manholes etc as detailed in above item No.1 to 4 will be carried out during the 1st 3 months from the date of commencement of work order N0.1 and there after shall be maintained for blockage free and smooth functioning of all the sewage lines and related sewage items as detailed in item N0.1 above for a period of eight months i.e., the date of completion of contract given in work order No.1. Engagement one supervisor along with two sweeper cum sewage drain attendent along with T&P required on daily basis for a period of eleven month for attending the daily sewage related complaints. the complaints shall be collected daily at 0830 hours from the office of Engr-in-charge by contractor/Contractor's supervisor and shall be got signed from the user occupant after clearing the complaints. These complaint slips will also be got signed at Engr-in-charge office daily after the satisfactory completion of each complaint. No complaint shall be kept pending/unattented for a period of 48 hours. any damage to man hole covers, gully tarp covers, CI assess doors of CI pipes any dia, PVC pipes/fitting, 'P' traps, floor traps during the process of cleaning/clearing shall be made good by the contaractor by the contractor by replacing same by new items without ant extra cost to the govt. (ii) If contractor fail to complete the complaint within stipulated period i.e 48 Hrs a recovery of Rs 300 per complaint per day will be levied.
M&L for cleaning/taking off of sludge (solid/semi solid) of any state from manhole of any size including gully trap having depth not exceeding 1.5m by using machinery or manually as required and removing the same to a distance n.exc 250m and burying the same underground by digging pit of suatible size in low laying area from habbatient area and returning filling with excavated materials up to ground level including removal of surplus soil to a distance n.exc 250m with and including taking off manholes/gully trap covers and re-fixing the same after cleaning process complete all as specified and directed by Engr-in-Charge. Note :- (i) The contractor/site superivisor will attend the complaint cell of AGE B/R-III to receive the complaint slips daily at 0900 hrs to carry out the complaints and completion report will be submitted to concerned JE/AGE in the same day i.e. before 1700 hrs. (ii) If contractor fail to complete the complaint within stipulated period a recovery of Rs 300 per complaint per day will be levied.
M&L for cleaning/taking off of sludge (solid/semi solid) of any state from manhole of any size including gully trap having depth exceeding 1.5m but not exceeding 3.00m by using machinery or manually as required and removing the same to a distance n.exc 250m and burying the same underground by digging pit of suatible size in low laying area from habbatient area and returning filling with excavated materials up to ground level including removal of surplus soil to a distance n.exc 250m with and including taking off manholes/gully trap covers and re-fixing the same after cleaning process complete all as specified and directed by Engr-in-Charge. Note :- (i) The contractor/site superivisor will attend the complaint cell of AGE B/R-III to receive the complaint slips daily at 0900 hrs to carry out the complaints and completion report will be submitted to concerned JE/AGE in the same day i.e. before 1700 hrs. (ii) If contractor fail to complete the complaint within stipulated period a recovery of Rs 300 per complaint per day will be levied.
M&L for opening/cleaning of blocked WC of any type, traps and CI/PVC drain pipe including fitting (i.e. access door bends/tee etc.) of any size at any floor & position with and including taking down of CI/CP/PVC grating and refixing the same at position with appropriate materials/fitting i.e. white cement, solvent, nuts & bolts etc. and well flushing, pressure pumping, taking out all residue materials etc.and removing the same to a distance n.exc 250m and burying the same underground by digging pit of suitable size from habitant area and covering same with the earth level including removal of surplus soil to a distance 250m complete all as specified and directed by Engr-in-Charge. Note :- (i) The contractor/site superivisor will attend the complaint cell of AGE B/R-III to receive the complaint slips daily at 0900 hrs to carry out the complaints and completion report will be submitted to concerned JE/AGE in the same day i.e. before 1700 hrs. (ii) If contractor fail to complete the complaint within stipulated period a recovery of Rs 300 per complaint per day will be levied.
Excavation in trenches, not exceeding 1.5m wide and not exceeding 1.5m in depth for foundation, etc or for shafts, wells, cesspits, manholes, pier holes, etc n.exc 10 Sqm on plan and getting out in soft/loose soil complete all as specified and directed.
Returning filling in layers including leveling watering and well ramming in layers not exc. 25cm thick complete all as specified and directed.
Removing surplus spoil to a distance not exc. 50m and depositing where directed at a level n. exc. 1.5m above the starting point complete all as specified and directed.
Material & labour for PCC (1:4:8) type D-2 (using 40mm graded stone aggregate) as in foundation filling, mass concrete etc complete all as specified and directed.
M&L for Precast Cement concrete1:2:4 type B-1 using (20 mm graded crushed stone aggregate)but in landing ,cover slabs (for manhole etc)chullah hoods,chajjas water trough,mangers,shelves and similar articles with plain face set in CM1:4 incl demolition of cement concrete (reinforced) of any discription and in any position not otherwise specifically provided complete all as specified and directed.
Material & labour for mild steel high yield strength TMT bars 10 mm dia and over cut to length bent to shape required, including cranking, hooking ends, bending and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
Material & labour for mild steel high yield strength TMT bars 6 to 8 mm dia cut to length bent to shape required, including cranking, hooking ends, bending and binding with and including MS wire (annealed) not less than 0.9 mm dia complete all as specified and directed.
M&L brick work with sub class 'B' bricks straight or curved in plan exc 6 mtr mean radius built in CM (1:6) using old size bricks with and including demolition of brickwork built in cement mortar complete all as specified and directed by the Engr-in-Charge.
M&L for Random rubble masonry built in cement mortar 1:6,uncourse,well bondded and solidly hearted incl demolition of brick work or stone masonry built in cement mortar including all quions, arches, pillars, etc.complete all as specified and directed
Material & labour for Extra over stone walling for hammer dressing to face stones and dressing of face stones and dressing of face beds and joints, as speified of random rubble walling of granite or trap stone,uncoursed or brought up to course,hammer dressing with maximum depression on face from straight edge held against the dressed surface not exceeding 40mm,complete.all as specified and directed.
Material & labour for 15mm thick cement plaster in cement mortar (1:4) on fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified.
Material & labour for 15mm thick cement plaster in cement mortar (1:6) on other than fair faces of brick or concrete surfaces finished even and smooth without using extra cement complete all as specified.
Material & labour for PCC (1:2:4) type B-0 (using 12.5 mm graded stone aggregate) as in lintels upto 1.5 m clear span, cills, steps, seismic and other similar bands plinth cources, roof kerbs or mud stops, benching, coping, bed plates, parapets, water throughs and the like etc including weathering, slightly rounded or chamfered angles throating etc complete including necessary form work complete all as specified and directed.
M&L for reinforced concrete pipes, class NP3, internal diameter 150 mm laid in trenches and jointed complete with collars incl demolition and breaking up drain pipes (salt glazed stoneware, AC or Reinforced concrete) set in cement mortar any internal dia 150mm complete,all as specified and directed.
M&L for reinforced concrete pipes, class NP3, internal diameter 100 mm laid in trenches and jointed complete with collars incl demolition and breaking up drain pipes (salt glazed stoneware, AC or Reinforced concrete) set in cement mortar any internal dia 100mm complete,all as specified and directed.
M&L for concrete bed to drain pipes 150mm bore laid bed including packing under and haunching against the sides of pipes after they are laid and tested in cement concrete 1:3:6 type C-2 complete all as specified and directed by Engr-in-Charge.
All as per item no. 23 above but dia 100mm bore.
Cutting into existing manhole removing existing drain making good to wall and rendering cutting out branch channel and making good benching for 150mm dia pipe in cement concrete 1:2:4 complete all as specified and directed by Engr-in-Charge.
All as per item no. 25 above but dia 100mm bore.
S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to floors with necessary MS clamps complete all as specified and directed by Engr-in-Charge.
S&F in repair 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to floors with necessary MS clamps complete all as specified and directed by Engr-in-Charge.
S&F in repair 110 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with necessary MS clamps complete all as specified and directed by Engr-in-Charge.
S&F in repair 75 mm bore PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to walls with necessary MS clamps complete all as specified and directed by Engr-in-Charge.
Material & labour for cast iron floor trap outlet diameter 100mm, plain with grating including jointing with solvent & cement concrete 1:2:4 complete all as specified and directed.
S&F in repair 75 mm PVC (SWR) access door bends any radius including taking down old complete all as specified and directed by Engr-in-Charge.
S&F in repair 110 mm PVC (SWR) access door bends any radius including taking down old complete all as specified and directed by Engr-in-Charge.
Material & labour for cast iron soil, waste and vent pipe of bore 100mm, sand cast type in any length with or without ears with cement joints fixed to wall/laid in trenches complete all as specified and directed.
Material & labour for cast iron soil, waste and vent pipe of bore 75mm, sand cast type in any length with or without ears with cement joints fixed to wall/laid in trenches complete all as specified and directed.
Material & labour for coloured ceramic non skid tiles 7 to 8mm thick, as approved, polished area of each tiles exc 0.11 Sqm but n.exc. 0.18 Sqm (square/ rectangular) as in floors, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over & including screed bed 15mm thick in cement mortar (1:6) complete including dismantling all as specified and directed.
M&L glazed ceramic coloured as required pattern tiles in 300 x 200 x 7-8 mm thick on vertical surfaces such as dado etc set and jointed in neat cement slurry and pointed in white or colour cement to match over with and including 10mm thick backing coat in CM 1:3 and dismantling floor hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed by Engr-in-Charge
Supply & fix in repairs squatting pan WC Orissa pattern size 580mm x 440mm white with integral foot rest (excluding flushing cistern) with P or S trap including provision of lime concrete bedding including breaking up existing damaged WC seat and connecting flush pipe etc making good to match with existing surfaces complete all as specified and directed.
Supply & fix in repairs PVC white low level flushing cistern 10 ltr capacity with all fittings syphonic action with top push type button with inlet ball valve and float including flush pipe, ball valve, handle, bracket PVC short bend etc. complete all as specified and directed.
S&F 15 mm dia PVC connections, 600 mm long with PTMT nuts of suitable size at two end complete all as specified and directed by Engr-in-Charge.
Supply & fix in repairs vitreous china wash down water closet pan (pedestal pattern) white including plastic water closet sheet cover white, closed pattern with flat bottom, with mild steel chromium plated or aluminised hinging device and including mild steel chromium plated jet fixed to water closet with 360mm wide x 390mm high and 415 to 445mm long flexible pipe complete all as specified and directed.
Supply & fix in repairs coloured Plastic seat cover closed pattern with flat bottom and cover with MS CP or aluminized hinging device complete all as specified.
S&F in repairs for flush pipe of polyethylene of low and high density of PVC 32 mm for low level cistern complete as specified.
S&F in repairs of health faucet assembly, brass, chromium plated consist of valve, sprayer, PVC flexible pipe for EWC suitable for 15mm bore pipe, complete all as specified and directed.
Supply and fix in repairs, urinal, flat back or corner wall type of size 465x355x265mm white (excluding flushing cistern, flush pipe and waste pipe) including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60mm long brass screws, pointing around urinal back in cement including flush pipe, grating and Union for discharge pipe complete all as specified and directed.
M&L for Chequered cement concrete tile 200mmx200mmx25mm thick machine pressed set jointed and pointed in neat cement slurry with grey cement and pigment in floors incl screed bed or bedding layes of mortar 15 mm in CM 1:6 for laying floor finishes including 75mm thick cement Concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregates as in floor/sub base and finished even and fair complete,all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F for Mild steel framed work as in Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts;posts and struts in fencing including cutting tops to shape as directed, drilling holes,notching for wire, etc.; flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc.,and similar work onforming to Fe-290 Gde E-165 complete,all as specified and directed.
S&F for Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins, etc. as directed (each line wire to be measured) complete,all as specified and directed.
Supply only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provission of binding wire all as specified and directed.
M/S LATIF AHMAD BABA CONSTRUCTION
M/S Sultan Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .