Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹49.2 LAccepted-AOC 5 KEDAR APARTMENTS 484 60 PARVATI MITRAMANDAL COLONY PARATI PUNE 411 009 | PUNE | PUNE | MAHARASHTRA | 411009 | L1 | Accepted-AOC ACCEPTED BEING LOWEST BIDDER | |
| 2 | L2₹54.5 L+₹3.1 L (6.07%)Rejected-Finance 02 PADRI SHIV NAGAR SHIV NAGAR MAHARAJGANJ UTTAR PRADESH 273303 | MAHARAJGANJ | UTTAR PRADESH | 273303 | L2 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 3 | L3₹65.1 L+₹13.8 L (26.8%)Rejected-Finance | L3 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 4 | L4₹65.4 L+₹14.1 L (27.4%)Rejected-Finance | L4 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER | |
| 5 | L5₹67.7 L+₹16.3 L (31.7%)Rejected-Finance | L5 | Rejected-Finance REJECTED BEING NOT LOWEST BIDDER |
| Sl No | Description | Qty | Unit | JP ENTERPRISES L2 | M/S. Niksun Electro-Infra Private Limited L9 | H S TAKHI L7 | MAHESH DADAJI BACHHAV L5 | L.K.R.TIWARI CONSTRUCTION L6 | Mehta Construction Co. L1 | V.R.PRAJAPATI AND CO. L4 | agarwal and company L8 | MANIYA CONSTRUCTION CO L3 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling of posts or struts embedded in Concrete, brick work, masonary, etc (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground to match with existing all as specified and directed. | 1,150 | RM | 5 ₹5,750 | 30 ₹34,500 | 1.8 ₹2,070 Lowest | 20 ₹23,000 | 22 ₹25,300 | 10 ₹11,500 | 10 ₹11,500 | 45 ₹51,750 | 30 ₹34,500 |
| 2.00 | Excavation in post holes in soft/loose soil (or similar holes) each n. exc 0.5 Cum and getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm watering, and removing surplus soil to a distance n exc 50m and making good disturbed surface all as specified and directed. | 383 | Each | 60 ₹22,980 | 200 ₹76,600 | 63 ₹24,129 | 200 ₹76,600 | 135 ₹51,705 | 90 ₹34,470 | 50 ₹19,150 Lowest | 216 ₹82,728 | 66 ₹25,278 |
| 3.00 | M&L PCC (1:2:4) type B-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concret all as specified and directed. | 15 | Cum | 2,800 ₹42,000 | 6,000 ₹90,000 | 3,600 ₹54,000 | 5,000 ₹75,000 | 4,500 ₹67,500 | 1,800 ₹27,000 Lowest | 4,200 ₹63,000 | 5,400 ₹81,000 | 3,600 ₹54,000 |
| 4.00 | M&L PCC (13:6) type C-2 (using 40mm graded crushed stone aggregate) as in fixing of fencing post all as specified and directed. | 21.11 | Cum | 2,200 ₹46,442 | 5,500 ₹1,16,105 | 2,250 ₹47,497.5 | 4,500 ₹94,995 | 4,000 ₹84,440 | 2,000 ₹42,220 | 1,000 ₹21,110 Lowest | 4,500 ₹94,995 | 3,300 ₹69,663 |
| 5.00 | S&F Joist, channel, angle or tee section fixed independly without connecting plates etc (cut to ordinary length) Fe 410-W (gde-E-250 quality A) all as specified and directed. | 5,457.75 | Kg | 80 ₹4,36,620 | 90 ₹4,91,197.5 | 85.5 ₹4,66,637.63 | 90 ₹4,91,197.5 | 99 ₹5,40,317.25 | 70 ₹3,82,042.5 Lowest | 85 ₹4,63,908.75 | 108 ₹5,89,437 | 89 ₹4,85,739.75 |
| 6.00 | Dismantling fencing wire mesh, any type, size and any position and removing the unserviceable wire mesh from work site all as specified and directed. | 2,160 | Sqm | 5 ₹10,800 | 6 ₹12,960 | 4.5 ₹9,720 Lowest | 5 ₹10,800 | 7 ₹15,120 | 10 ₹21,600 | 5 ₹10,800 | 9 ₹19,440 | 6 ₹12,960 |
| 7.00 | Supply only Chain link MS galvanised fencing, any size or type all as specified and directed. | 4,536 | Kg | 95 ₹4,30,920 | 82 ₹3,71,952 | 85.5 ₹3,87,828 | 80 ₹3,62,880 Lowest | 93 ₹4,21,848 | 96 ₹4,35,456 | 95 ₹4,30,920 | 108 ₹4,89,888 | 110 ₹4,98,960 |
| 8.00 | Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire all as specified and directed. | 2,160 | Sqm | 15 ₹32,400 | 10 ₹21,600 Lowest | 18 ₹38,880 | 60 ₹1,29,600 | 30 ₹64,800 | 11 ₹23,760 | 10 ₹21,600 Lowest | 45 ₹97,200 | 39 ₹84,240 |
| 9.00 | S&F in repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins including taking down etc. as directed (each line wire to be measured) all as specified and directed. | 350 | Per 100 RM | 1,100 ₹3,85,000 Lowest | 1,500 ₹5,25,000 | 1,800 ₹6,30,000 | 1,800 ₹6,30,000 | 1,350 ₹4,72,500 | 1,300 ₹4,55,000 | 2,600 ₹9,10,000 | 1,530 ₹5,35,500 | 1,300 ₹4,55,000 |
| 10.00 | Fixing only Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel
pins etc. as directed (each line wire to be measured) all as specified and directed. | 10 | Per 100 RM | 200 ₹2,000 Lowest | 500 ₹5,000 | 630 ₹6,300 | 1,200 ₹12,000 | 390 ₹3,900 | 1,000 ₹10,000 | 1,500 ₹15,000 | 360 ₹3,600 | 300 ₹3,000 |
Tender Value
₹1.1 Cr
EMD Value
₹1.8 L
Closing Date
30 Oct 2025, 6:00 pmClosed
CWE Khadki Pune
Headquarters CWE Khadki, Military Engineer Services, Range Hills Road, Khadki, Pune-411003
REPAIR MAINT TO CHAIN LINK FENCING BARBED WIRE BOUNDARY WALL JAFFERY WALL GATES HARD STANDING AND ALLIED WORKS IN ZONE A AREA OF AGE BR I UNDER GE CENTRAL KHADKI
2025_MES_733312_1
CWE/KKE/TOKEN-27 OF 2025-26
Open Tender
Civil Works
Item Rate
180 days
CWE Khadki Pune
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹1,000
GE CENTRAL KHADKI
₹1.8 L
Yes
26 Dec 2025
30 Sept 2025
1 Nov 2025
30 Sept 2025
30 Oct 2025
23 Oct 2025
30 Sept 2025 - 15 Oct 2025
Amount
Dismantling of posts or struts embedded in Concrete, brick work, masonary, etc (wood, steel or R.C.C.) any section, including taking out embedded portion and making good disturbed ground to match with existing all as specified and directed.
Excavation in post holes in soft/loose soil (or similar holes) each n. exc 0.5 Cum and getting out returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exc 25cm watering, and removing surplus soil to a distance n exc 50m and making good disturbed surface all as specified and directed.
M&L PCC (1:2:4) type B-2 (using 40mm graded crushed stone aggregate) as in foundation filling and mass concret all as specified and directed.
M&L PCC (13:6) type C-2 (using 40mm graded crushed stone aggregate) as in fixing of fencing post all as specified and directed.
S&F Joist, channel, angle or tee section fixed independly without connecting plates etc (cut to ordinary length) Fe 410-W (gde-E-250 quality A) all as specified and directed.
Dismantling fencing wire mesh, any type, size and any position and removing the unserviceable wire mesh from work site all as specified and directed.
Supply only Chain link MS galvanised fencing, any size or type all as specified and directed.
Fixing only chain link fencing including line wires, any mesh, size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire all as specified and directed.
S&F in repairs Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins including taking down etc. as directed (each line wire to be measured) all as specified and directed.
Fixing only Galvanised. 2 strand, steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75mm spacings and straining and fixing to any type of standard rails straining bolts, including, securing or tying at crossings with and provision of galvanised mild steel wire, staples or steel pins etc. as directed (each line wire to be measured) all as specified and directed.
S&F mild steel Hand rails, half round or other steel section or core for wooden hand-rail straight portion, drilled and countersunk for balusters running bars, for doors, balusters, nosing to steps including embeding in concrete and screwing etc. wind ties for roof including securing bolts; posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc flat iron fillets (for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc and similar work conforming to Fe-290 Gde E-165 all as specified and as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc, but excluding ashlars facings, dressed stone work and precast concrete articles and removing the debris out side the defence land all as specified and directed
M&L Walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar (1:4) all as specified and directed.
All as per item No 13 above but except stone all as specified and directed.
M&L pre-cast cement concrete solid block masonry with solid block of the grade type C-1, (1:3:6) (using 20mm graded crushed stone) aggregate set in CM (1:4) all as specified and directed.
Extra over stone walling for hammer dressing to face stones and dressing of face beds and joints as specified of random rubble walling, coursed, hammer dressing with maximum depression on face from straight edge held against the dressed surface n.exc 40mm on lime/sand stone all as specified and directed.
M&L for raised pointing to RR masonry in CM 1:4 all as specified and directed.
Removing cement mortar from and cleaning stones, obtained from masonry of any description (except ashlar facings and dressed stone work) and stone setts from pavings; stacking for measurement including all extra handling and removal and disposing off rubbish all as specified and directed.
M&L 15mm thick rendering on brick /concrete surfaces in CM 1:4 with water profing compound, finished surfaces even & smooth without using extra cement all as specifed and as directed. Note: WPC mesured and paid seperetly
Taking down steel / iron gates area not exc 10 Sqm each including hold fasts and re-fixing the gates in the same opening including shifting and fixing of existing holdfast in plain cement concrete (1:2:4), type B-1 after raising the gate level including greasing, painting and other necessary minor repairs all as specified and directed.
M&L for Framed work as in doors or gates of angle or other section (i.e flat/tubular) with gusset plates, rails, braces of Fe-410-W (Gde-E-250) quality-B, etc. complete, drilled for fixing of steel sheeting or other covering, doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges/holdfast or steel hanging door fittings in plain cement concrete (1:2:4), type B-1 (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing all as specified and directed.
S&F in repairs 1mm thick Mild steel, plain, black sheet in wall cladding, steel gates and similar work, cut to size, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles, etc as per required at site all as specified and directed.
Demolition of cement concrete (unreinforced) in ground floors and pavings n. exc 15cm thickness (below of above ground level) and removing the debris outside the defence land all as specifed and directed.
M&L PCC type D-2 (1:4:8) (using 40mm graded crushed stone aggregate) as in sub base all as specifed and directed.
M&L PCC (1:2:4) type B-2, 100mm thick (using 40mm graded crushed stone aggregate) finishing cement concrete surfaces even and smooth without using extra cement all as specified and directed
M&L for forming Construction joints 30mm deep x 10mm wide filled with sealing compound Grade A all as specified and directed
M&L PCC (1:3:6) type C-2, 75mm thick (using 40mm graded crushed stone aggregate), finishing cement concrete surface even and smooth without using extra cement including provision of construction joints all as specified and directed.
M&L in repairs for Chequered cement concrete rubber moulded coloured tiles glossy finish 300mm x 300mm x 25mm thick, set, jointed and pointed in neat cement slurry in floors laid over and including 15 mm thick screed bed of cement mortar (1:6) including pointing with white cement with pigment to match the shade of tiles including demolition of existing tiles and removing the debris outside the defence land all as specifed and directed.
M&L for cement concrete (1:2:4) type B-1 (using 20mm graded crushed stone aggregate) as in bed block, benching, kerb, mud stop, rounded or chamferred on edges, coping including necessary form work wherever required all as specifed and directed
M&L in repairs Rubber moulded coloured glossy finish (Red, Yellow & Black) precast concrete interlocking paver blocks with grey cement and pigment of any shape and size, shade as approved by GE, 60mm thick conforming to IS 15658-2006 M-35 grade and interstices filled with sand including 25mm thick sand cushioning and including demolition of existing tiles and removal of debrice outside the MoD land all as specified and directed.
M&L in repairs Granite 20mm thick work (table rubbed and polished) in steps, jambs, pillars, window-cills, cooking platforms, vertical surface of wall also and like in 12mm thick screed bed or bedding layer of cement mortar (1:3) including pointing in white cement (1:2) using marble dust with admixture of pigment to match with shade of granite including dismantling and removing the debris outside the defence land all as specified and directed.
M&L for Providing precast cement concrete 1:2:4 type B-0 (using 12.5 mm graded crushed stone aggregate) as in louvres and jallies, 40 mm thick and Set in Cement Mortar 1:6 including demolition of existing RCC jallies and removing the debris outside the defence land all as specified and directed.
Demolition of (reinforced) cement concrete of any description and in any position and thickness all as specified and as directed (Reinforcement cut as to facilitate demolition) all as specified and directed.
M&L reinforced cement concrete (nominal mix) type B-0 (1:2:4) (using 12.5mm graded crushed stone aggregate) for walls, retaining walls, basement walls, ballast walls and like any thickness above top of footing including attached pilaster and buttresses all as specified and directed.
Use and waste formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railing, opening in concrete wall, floor and roofs n. exc 20cm wide and sides of RCC/PCC bands in walls, horizontal or sloping and similar work exc 10cm but n. exc 20cm wide all as specified and directed.
S&F Mild steel TMT bars 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips all as specifed and as directed.
All as per sr item 36 but 5 mm dia and over up to and including 10mm dia in stirrups, spacers and binders all as specified and directed.
Use & waste formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter as in rough finished surface of concrete flat/square/rectangular all as specified and directed.
Use & waste form work to sides of pillars, posts, struts, piers, columns and stanchions rough finished surfaces of concrete square, rectangular or polygonal all as specified and directed.
M&L for RCC Nominal Mix type B1 (1:11/2 :3 ) (using 20 mm graded crushed stone aggregate) as in columns, pillars, piers, posts and struts all as specified and directed.
M&L RCC Nominal mix Type B1 (1:11/2 :3) (using 20mm graded agg) as in Foundations, including rafts,footings, foundation beams; plinth beams; bases for columns, etc. basement slabs, under-reamed piles and mass concrete all as specified and directed.
Excavation in trenches n. exc. 1.5 m wide and n. exc. 1.5 m in depth; for foundation etc or for shafts, wells, cesspits, manholes, pier holes etc nexc 10 Sqm on plan and nexc 1.5m in depth and getting out in soft/loose soil all as specified and directed.
Returning filling in, including spreading, leveling, watering and well ramming in layers nexc 25cm in soft/loose soil in excavated pit or trenches all as specified and directed.
Removing excavated soil/material n exc. 50m and depositing where directed at a level n exc. 1.5 m above the starting point all as specified and directed.
M&L in repairs for providing Precast cement concrete block Type B-1 (1:2:4) (using 20mm graded crushed stone aggregate) factory made as in Bed blocks, kerb stone etc with plain fair faces including chamfers, weathering, throating etc and setting in cement mortar 1:4 including demolition of existing kerb stones and removing the debris outside the defence land all as specified and directed.
M&L for preparation of new or previously untreated steel surface of any description over 10cm in width or girth and applying two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
M&L for 15mm thick Rendering on brick /concrete or dubbed surface in CM 1:6 with water profing compound finishing even & smooth without using extra cement and similar like at any height including necessary scaffolding , ladder & formwork including taking down cement plaster, raking out joints, hacking for key & scrubbing down with water and removing the debris outside defence land all as specifed and directed. Note : water proofing compound shall be measured & paid separetely)
M&L for 15mm thick Rendering on brick /concrete or dubbed surface in CM 1:4 with water profing compound finishing even & smooth without using extra cement and similar like at any height including necessary scaffolding , ladder & formwork including taking down cement plaster, raking out joints, hacking for key & scrubbing down with water and removing the debris outside defence land complete all as specifed and directed. Note : water proofing compound shall be measured & paid separetely)
Supply only Liquid water proofing compound complete all as specifed and directed.
M&L for preparing new plastered surface of walls and applying two coat of cement base paint at any height including necessary scaffolding ladder all as specifed and directed.
M&L for preparation of old plastered or unplastered surface of walls and applying two coats of cement base paint of approved tint upto height 15 mtr including necessary scaffolding all as specified and as directed.
M&L for preparation of old painted steel surface of any description, not otherwise described over 10cm width or girth and applying one coat of synthetic enamel paint all as specified and directed
M&L 38 mm Plastic dividing strips inserted in position, conform to design complete all as specified and directed
JP ENTERPRISES (BID ID -3460317)
MANIYA CONSTRUCTION CO (BID ID -3463426)
V.R.PRAJAPATI AND CO. (BID ID -3463618)
MAHESH DADAJI BACHHAV (BID ID -3463148)
L.K.R.TIWARI CONSTRUCTION (BID ID -3463166)
H S TAKHI (BID ID -3462995)
agarwal and company (BID ID -3463718)
M/S. Niksun Electro-Infra Private Limited (BID ID -3462444)
Bidder Name
H S TAKHI
Mehta Construction Co.
JP ENTERPRISES
V.R.PRAJAPATI AND CO.
agarwal and company
L.K.R.TIWARI CONSTRUCTION
MAHESH DADAJI BACHHAV
M/S. Niksun Electro-Infra Private Limited
MANIYA CONSTRUCTION CO
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
TenderT27.pdf
Tender Documents • 1.02 MB
BOQ_821082.xls
BOQ • 3.48 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .