| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹8.4 LAccepted-AOC | ₹8.4 L | L-1 | Accepted-AOC L-1 |
| 2 | L2₹9.6 L+₹1.3 L (15.1%)Rejected-Finance 970 SECTOR 19 POCKET 3 DWARKA NEW DELHI SOUTH WEST DELHI DELHI 110075 | SOUTH WEST DELHI | DELHI | 110075 | ₹9.6 L+₹1.3 L (15.1%) | L2 | Rejected-Finance HIGHER THEN L-1 |
| 3 | L3₹12.0 L+₹3.6 L (43.2%)Rejected-Finance | ₹12.0 L+₹3.6 L (43.2%) | L3 | Rejected-Finance HIGHER THEN L-1 |
| 4 | L4₹13.5 L+₹5.1 L (61.3%)Rejected-Finance F 03 FIRST FLOOR PLOT NO 166 BEHIND TOKAS PLAZA AMVERHAI EXT SECTOR 19B DWARKA DELHI 110075 | DELHI | SOUTH WEST DELHI | DELHI | 110075 | ₹13.5 L+₹5.1 L (61.3%) | L4 | Rejected-Finance HIGHER THEN L-1 |
| 5 | L5₹13.7 L+₹5.4 L (64.0%)Rejected-Finance 645 SECTOR 30 FARIDABAD 121003 HARYANA | FARIDABAD | HARYANA | 121003 | ₹13.7 L+₹5.4 L (64.0%) | L5 | Rejected-Finance HIGHER THEN L-1 |
| Sl No | Description | Qty | Unit | Salasar Telecom L2 | PAL ENTERPRISES L3 | SARTHI POWER & INFRA TECH L4 | PEENACK ENTERPRISES L1 | PUNDER CONSTRUCTION ENGINEER L5 |
|---|---|---|---|---|---|---|---|---|
| 1.00Supply Fixing Testing and Commissioning | ||||||||
| 1.01 | Supplying, fixing, testing and commissioning of Wiring for circuit/ submain wiring along with earth wire with 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in and including surface/ recessed heavy duty minimum 2.2mm thick PVC conduit/ PVC Channel as per IS:9537 Part-3 latest as on date all as directed by Engineer -in Charge. | 360 | RM | 299 ₹1,07,640 | 190 ₹68,400 Lowest | 310 ₹1,11,600 | 250 ₹90,000 | 250 ₹90,000 |
| 1.02 | Supplying, fixing, testing and commissioning of Wiring for circuit/ submain wiring along with earth wire with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in and including surface/ recessed heavy duty minimum 2.2mm thick PVC conduit/ PVC Channel as per IS:9537 Part-3 latest as on date all as directed by Engineer -in Charge. | 320 | RM | 399 ₹1,27,680 | 340 ₹1,08,800 Lowest | 350 ₹1,12,000 | 350 ₹1,12,000 | 350 ₹1,12,000 |
| 1.03 | Supplying, fixing, testing and commissioning Wiring for circuit/ submain wiring along with earth wire with 4 x10 sq. mm + 2x 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in and including surface/ recessed heavy duty minimum 2.2mm thick PVC conduit/ PVC Channel as per IS:9537 Part-3 latest as on date all as directed by Engineer -in Charge. | 260 | RM | 1,355 ₹3,52,300 | 1,960 ₹5,09,600 | 1,150 ₹2,99,000 | 1,100 ₹2,86,000 Lowest | 1,200 ₹3,12,000 |
| 1.04 | Supplying and fixing 1 or 2 Module (75 mm X 75 mm), GI box along with modular base & cover plate for modular switches in recess etc. as required. | 24 | Each | 195 ₹4,680 | 181 ₹4,344 | 250 ₹6,000 | 200 ₹4,800 | 150 ₹3,600 Lowest |
| 1.05 | Supplying and fixing 3 Module (100 mm X 75 mm), GI box along with modular base & cover plate for modular switches in recess etc. as required. | 60 | Each | 345 ₹20,700 | 250 ₹15,000 | 300 ₹18,000 | 250 ₹15,000 | 200 ₹12,000 Lowest |
| 1.06 | Supplying and fixing 6 Module (200mmX75mm), GI box along with modular base & cover plate for modular switches in recess etc. as required. | 10 | Each | 455 ₹4,550 | 430 ₹4,300 | 400 ₹4,000 | 175 ₹1,750 Lowest | 250 ₹2,500 |
| 1.07 | Supplying, fixing, testing and commissioning 6 amps modular switch on the modular plate & switch box including connections but excluding modular plate required (Similar to Legrand- Arteor or equivalent from Approved List of Make), connections etc. as required. | 60 | Each | 175 ₹10,500 | 90 ₹5,400 Lowest | 100 ₹6,000 | 200 ₹12,000 | 110 ₹6,600 |
| 1.08 | Supplying, fixing, testing and commissioning 16/20 amp modular switch on the modular plate & switch box including connections but excluding modular plate required (Similar to Legrand- Arteor or equivalent from Approved List of Make), connections etc. as required. | 10 | Each | 355 ₹3,550 | 280 ₹2,800 | 150 ₹1,500 Lowest | 375 ₹3,750 | 175 ₹1,750 |
| 1.09 | Supplying, fixing, testing and commissioning 3 pin 6 A modular socket outlet on the modular plate & switch box including connections but excluding modular plate required (Similar to Legrand- Arteor or equivalent from Approved List of Make), connections etc. as required. | 60 | Each | 225 ₹13,500 | 296 ₹17,760 | 450 ₹27,000 | 275 ₹16,500 | 180 ₹10,800 Lowest |
Tender Value
₹14.3 L
EMD Value
₹28,559
Closing Date
15 Jul 2025, 5:30 pmClosed
SHRI VIKAS TYAGI
CHIEF CONSTRUCTION ENGINEER RnD NORTH DEVELOPMENT ENCLAVE, RAO TULA RAM MARG
ADDITION/ALTERATIONS and AUGMENTATION OF POWER SUPPLY AND RELATED WORKS AT NSB
2025_DRDO_865687_1
CCE/RnD/N/ENQ/NIT/2024-25
Open Limited
Miscellaneous Works
Item Rate
90 days
NEW DELHI
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹28,559
Yes
CCE(RnD)NORTH
15 Oct 2025
25 Jun 2025
17 Jul 2025
26 Jun 2025
15 Jul 2025
5 Jul 2025
1 Jul 2025
Amount
Supply Fixing Testing and Commissioning
Supplying, fixing, testing and commissioning of Wiring for circuit/ submain wiring along with earth wire with 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in and including surface/ recessed heavy duty minimum 2.2mm thick PVC conduit/ PVC Channel as per IS:9537 Part-3 latest as on date all as directed by Engineer -in Charge.
Supplying, fixing, testing and commissioning of Wiring for circuit/ submain wiring along with earth wire with 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in and including surface/ recessed heavy duty minimum 2.2mm thick PVC conduit/ PVC Channel as per IS:9537 Part-3 latest as on date all as directed by Engineer -in Charge.
Supplying, fixing, testing and commissioning Wiring for circuit/ submain wiring along with earth wire with 4 x10 sq. mm + 2x 6 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in and including surface/ recessed heavy duty minimum 2.2mm thick PVC conduit/ PVC Channel as per IS:9537 Part-3 latest as on date all as directed by Engineer -in Charge.
Supplying and fixing 1 or 2 Module (75 mm X 75 mm), GI box along with modular base & cover plate for modular switches in recess etc. as required.
Supplying and fixing 3 Module (100 mm X 75 mm), GI box along with modular base & cover plate for modular switches in recess etc. as required.
Supplying and fixing 6 Module (200mmX75mm), GI box along with modular base & cover plate for modular switches in recess etc. as required.
Supplying, fixing, testing and commissioning 6 amps modular switch on the modular plate & switch box including connections but excluding modular plate required (Similar to Legrand- Arteor or equivalent from Approved List of Make), connections etc. as required.
Supplying, fixing, testing and commissioning 16/20 amp modular switch on the modular plate & switch box including connections but excluding modular plate required (Similar to Legrand- Arteor or equivalent from Approved List of Make), connections etc. as required.
Supplying, fixing, testing and commissioning 3 pin 6 A modular socket outlet on the modular plate & switch box including connections but excluding modular plate required (Similar to Legrand- Arteor or equivalent from Approved List of Make), connections etc. as required.
Supplying, fixing, testing and commissioning 6 pin 16/20 amp modular socket outlet on the modular plate & switch box including connections but excluding modular plate required (Similar to Legrand- Arteor or equivalent from Approved List of Make), connections etc. all as directed by Engineer -in Charge.
Supplying, fixing, testing and commissioning Telephone socket outlet on the modular plate & switch box including connections but excluding modular plate required (Similar to Legrand- Arteor or equivalent from Approved List of Make), connections etc. all as directed by Engineer -in Charge.
Supplying and drawing 1 run of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
Supplying and drawing 2 run of cable of UTP 4 pair CAT 6 LAN Cable in the existing surface/ recessed Steel/ PVC conduit as required.
Supplying and fixing following way, horizontal type three pole and neutral, sheet steel thickness minimum 1.6mm, MCB PPI / Flexi distribution board, 415 V, on surface/ recess, complete with 3Nos. tinned copper bus bar (For three phase, 3Nos. neutral bus bar (For three phase), earth bar, din bar, interconnections, powder painted (minimum 60-80 micron) including earthing etc. as required. (But without MCB/RCCB/ Isolator) Make :- Legrand or equivalent suitable for 8 way (4 + 24), Double door all as directed by Engineer -in Charge.
Supplying and fixing 6-32A (Single Pole) 240/415 V, C curve 6kA MCB (Suitable for isolation) in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying and fixing100 amp Triple pole and Neutral 415 V, C curve 6kA MCB (Suitable for isolation) in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Supplying, fixing, and testing chlorinated polyvinyl chloride (CPVC) pipe 65 mm nominal diain and including all types of fitting and accessories required at site with interval of support for piping systems designed to provide for expansion/contraction shall conform to the good engineering practice by cutting the pipe squarely, removing burrs and beveled edges, and joining them with solvent cement complete all as directed by Engineer -in -charge
Salasar Telecom (BID ID -3248681)
PAL ENTERPRISES (BID ID -3249122)
SARTHI POWER & INFRA TECH (BID ID -3248852)
PUNDER CONSTRUCTION ENGINEER (BID ID -3243446)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .